Professional Documents
Culture Documents
AS9093 A
Page 1 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
TABLE OF CONTENTS
1.0 PURPOSE
2.0 SCOPE
4.0 EQUIPMENT
7.0 PROCEDURE
10.0 RESPONSIBILITY
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 2 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
1.0. PURPOSE
This document defines the basic guidelines, operating procedure and control for the encapsulation of Ball Grid
Array (BGA), Land Grid Array (LGA) devices, and Flip Chip Array Packages.
2.0. SCOPE
This document covers the entire BGA, LGA and Flip Chip Array Packages molding process procedure, control
procedure, quality requirements and the following auxiliary procedures: On-loading of magazine, Offloading of
magazine, Molding compound loading, Mold die cleaning and conditioning, Clearing of machine alarms, Process
control monitor / Total control methodology, End-of-shift or no material shutdown, General handling requirements
and Inspection procedures for critical characteristics.
3.3. ASAHI Cosmo BGA Auto molding system instruction / operating manual.
3.8. Anti mixing Procedure in Handling Production Lots at Assembly and Test (SOP 5065)
3.9. Standard Procedures for Handling Unbonded and Bonded Strips (SOP 5082)
4.0. EQUIPMENT/TOOLS/LOGISTICS
4.2. Fico Mold AMS-36-M2 Strip and Pellet loader for semi-auto operation.
4.5. ASAHI Auto Mold Cosmo BGA2-40 and applicable Mold chase.
4.8. MFS-4080 E X-ray for wire defects and internal voids monitoring.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 3 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
5.0. SUPPLIES/MATERIALS
5.9. Conditioning sheet for prevention of sticking on first shot after mold idling and mold cleaning.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 4 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
6.0. FORMS AND RECORDS
6.6. Towa molding parameters –Table 10, Table 11, Table 12, Table 13, Table 14, Table 15, Table 16.
6.7. Asahi molding parameters – Table 17, Table 18, Table 19, Table 20
7.0. PROCEDURES
Some of the steps require huge visual aids and demonstrations to comprehensively include in this specification.
These steps or procedures are clearly explained in the manual of the machine.
In such cases, while this specification outlines the procedure briefly, it is required that the operators to be
certified for BGA, LGA and Flip Chip Array molding process be trained using the machine manual and actual
demonstration. Certification be granted base on actual line performance on dummy materials. The steps under
this condition are indicated with triple slash characters at the beginning.
7.1.1.1.1. Air ionizer is working by checking the air coming out of the air outlet.
7.1.1.3. Mold logistics such as: brass brush, brass picks, mirror, stain eraser are available.
7.1.2.1. Verify on the PT that the lot has undergone plasma process, and the time elapsed is
less than 24 hours, otherwise return the lot for re-plasma process. For re-plasma
information, refer to the note at the bottom of the PT: “Plasma prior mold and time of
completion”.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 5 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
7.1.2.2. Check all Appendix and special instructions, and follow the prescribed instructions
related to molding process.
7.1.2.3. Make sure that the magazine numbers written on the PT matched with the numbers of
the actual magazines.
7.1.2.4. Count the quantity of strips. It should match with the strip quantity written on the PT.
7.1.2.5. Ensure there is QA stamp on the Molding Material Removal from cold storage Monitor
sticker.
7.1.2.6. Production must perform checking on the compound type and exposure time as
below:
7.1.2.3.2 Prior loading new mold compound batch, mold operator must ensure
the following items:
7.1.2.7. If in doubt, ask the production supervisor or process engineer for clarification.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 6 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
7.1.3.1. Verify that the mold machine and mold chase to be used correspond to the
requirements on the PT as to the following:
7.1.3.1.1. Mold Cap Thickness (this information is written on the module name card,
chase metal plate ID and imprinted on the cavity bar).
The module name card and Chase ID markings are used only for easy
location of the mold system and module corresponding to the PT
requirement.
The operator should make sure that the PT requirement and the
marking on the cavity bar are matched. Use a mirror to easily see the
cavity markings.
The operators should also check the mold cap height of package on
the lot traveler and compare with mark on machine ID (Machine
Tag) as illustrated on para 7.1.3.1.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 7 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
7.1.3.1.2. Substrate thickness (this information is written on the module name card,
chase metal plate ID, and on Die Attach Process Instruction on lot
traveller).
Note:
For Fico, when change substrate thickness, need mold BGA
compensation process.
For Asahi, when change substrate thickness, need calibration using
same substrate P/N.
For Towa, when change substrate thickness, need mold tooling set
up by technician.
Special Case for 119 PBGA 14x22x2.15, reference mold cap height
is note on Mold process “USE CHASE WITH 0.9MM MCH”
7.1.3.2. Make sure that the cavity surface is free of stain; otherwise conduct mold cleaning and
conditioning sheet/pellet. Stain on the surface of the cavity appears as map of colors
other than the shiny metal finish of the cavity. For mold cleaning, refer to auxiliary
procedure – Mold Cleaning Procedure.
7.1.3.3. Make sure the mold chase to be used was not idle for more than sixteen 16 hours,
otherwise perform mold conditioning using conditioning rubber sheets on the cavity
surface and make three dummy shots.
Note: The number of dummy shots maybe increased until the traces of wax disappears.
7.1.3.4. Make sure no foreign materials on the chase or on the mold areas.
7.1.3.6. Set the mold parameters refer to the appropriate mold parameters board and
production material.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 8 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
7.1.3.7. Mistake proofing for FULL AUTO mold running with multiple module set-up
7.1.3.7.1. At start and idle time; ALL modules must be DISABLED. (No Possibility of
Molding, Manual and AUTORUN)
7.1.3.7.2. Mold personnel (MFG, EE, PE, and QC) must refer to current module lay
out and status.
7.1.3.7.3. Before buy-off run, operator to ask for set-up verification with EE.
7.1.3.7.5. Line EE/Tech. To EN-able the module compatible with the Prod. Lot (The
same Mold Cap, Substrate Thickness) to run.
7.1.3.7.6. EE / Production to run one dummy shot to verify the set up (Check actual
Mold Cap Height and Mold buy off criteria). Refer to Para 7.1.4. Buy off
Procedure – All machines.
7.1.3.7.8. Once production of the same lot type is completed and no more material to
be processed, operator to call EE/Tech.
7.1.3.7.9. EE/Tech. To disable ALL Module and set the machine to idle mode.
7.1.3.7.10. To start again on different lot type, please repeat item 7.1.3.6.
7.1.3.8. Log all necessary information required on the Production & Equipment Recording
Checksheet (see Appendix 4)
7.1.3.8.1. Visual and X-ray monitoring during Product Monitoring and Set-up /
Conversion will be done by assigned owners according to Control Plan
requirements (refer to SOP1158).
7.1.3.8.2. The following are the definitions for QC X-ray monitoring during set-up
and/or conversion:
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 9 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
7.1.4.1. Production to make one dummy shot per chase and perform visual inspection. All units
of the shots should meet external visual defects criteria in table 1. This inspection is
applicable to the following conditions:
7.1.4.1.1. After mold cleaning due to idle time, regular mold cleaning, regular mold
conditioner or other activities which require machine buy off.
7.1.4.1.2. After machine repair due to machine error, or defect found during in-line
monitoring or QC monitoring.
7.1.4.2. Production to make one shot of good or production strips per chase and perform visual
inspection. All units of the shots must meet the external visual defects criteria in table 1.
7.1.4.3. If no external defects are found, the same strips shall be submitted to QC for internal
buy off. Otherwise, the machine shall be down for repair.
7.1.4.4.1. Stop for QC buy off due to mold cleaning after power up the system or
machine idle for more than 16 hours. Resume production after passed QC
buy off.
7.1.4.4.2. Stop for QC buy off after trouble shooting and PM. Resume production after
passed QC buy off.
7.1.4.4.3. Running for QC buy off on regular QC monitoring or after regular cleaning /
conditioner. Stop immediately if this buy off is failed and QC will issue LDA.
7.1.4.4.4. Machine down time will be charge for QC buy off for item 7.1.4.4.1 and
7.1.4.4.2.
7.1.4.5. LINE DISTURBANCE ALERT (LDA) Issuance and Dis-abling of Mold Tool
7.1.4.5.1. QC must issue LDA if discrepancy or defect that is out of mold defect
criteria is encountered during regular monitoring.
7.1.4.5.2. PE/EE/Production shall define the root cause and take necessary corrective
action to address the defect and do confirmation shot to check the
effectiveness.
7.1.4.5.4. PE/EE/Production shall fill up the LDA and submit it together with mold shot
for QC check. Machine shall resume for production if buy off is Pass.
7.1.4.5.5. Identified mold/chase that takes time (more than 1 shift) for trouble shooting,
repairing or part replacement can be disabled for containment action. On
the other hand, other mold tool/chase of the same system can continue to
run to process production lots using normal monitoring procedure.
Disabling of mold/chase is allowed after the defect has been verified and
confirmed by PE and EE technicians to be an isolated case.
7.1.4.6. Any mold die set idling for more than 3 months, perform buy-off before running
production/qual lots as below:
Visual inspection
X Ray inspection
7.1.4.6.4. For machine monitoring and idle time, refer to PM (Preventive Maintenance)
ID/Record (MS1089).
7.1.4.7. TOWA auto-mold single shot or limited shot procedure. This procedure is done to
automatically stop the machine after making necessary shots for buy-off purposes.
7.1.4.7.1. Enter the number of strips required on the screen menu under "In L/F Set".
Once done, press <LINE AUTO> & <START> buttons consecutively to start
the cycle. The machine will stop after completion of the specified number of
strips.
7.1.4.8.1. The operator should watch at the on-load station. When the required strips
is being loaded on the hot plate, set the machine to stand-by mode by
pressing <INSTR> key, Select <2> and then press <ENTER> to bring the
machine to stand-by mode or select <3> and then press <ENTER> if only
one magazine loaded
7.1.4.8.2. Follow instruction at the User Interface (UI) screen until the shots are
completed and off-loaded.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 11 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
7.1.4.8.3. Before the machine comes to stand-by mode, the monitor screen or user
interface (UI) will ask whether to empty the pellet buffer or not. Reply “yes”
or press <1> if the stand-by mode will take more than five (5) minutes by
operator estimate.
7.1.4.9.2. Option 1 : Press “Start Running” button, then on the new display, thick or
activate one shot box follow by pressing “All Press Start Running” button to
process up to degate only. The machine will stop and alarm will be triggered
as soon as the molded frames are already in the lower degater plate. This
will be the visual inspection sample.
7.1.4.9.3. Option 2 : Press “Start Running” button then on the new display do not thick
One shot box, then press “All Press Start Running” button. Then after the 2
substrate pushed on the hot plate, press “F.O.L” button on Magazine
Exchange box. After strips entered to the off load magazine, press “E.O.L”
button on Magazine Exchange box then follow “Lot End” button.
7.2.1.1. Proceed with normal production only after all the requirements under item 7.1 are met.
7.2.1.2. Add appropriate dummy strip to the lot to make the total number of strips divisible by
two on the last lot to be processed. Before molding, the dummy strip must be identified
by red marker on gold gate. Make sure the mold caps will not cover the mark.
7.2.1.3. Load maximum of four (4) magazines at the on-load station. See auxiliary procedure –
On-loading Procedure of Magazines.
7.2.1.4. Load maximum of four (4) empty magazines at the off-load station. See auxiliary
procedure – On-loading Procedure of Magazines.
7.2.1.5. Check the machine auto system and choose the correct module that will be used for
production, then (press <SHIFT+F1…F4> to choose module station)
7.2.1.6. Run the machine in Automatic Mode by the following actions according to the machine
being used.
7.2.1.6.1. Set number of strip on In L/F Set as same as number of quantity of strip in
process traveler (PT)
7.2.1.6.2. Press the following buttons in sequence: <LINE AUTO>” and “<START>”.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 12 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
7.2.1.7. When it is necessary to stop the machine after the current shot, press <STOP> button.
7.2.1.8. To resume production shots, press <LINE AUTO> and <START> buttons
consecutively.
7.2.1.9. While the machine is in production mode, perform monitoring according to the
requirements described in Total Control Methodology (TCM).
7.2.1.10. When the last slot of the output magazine is filled, the machine will automatically eject
the magazine.
7.2.1.11. After completion of the lot, completely fill up the PT. At the input magazine, remove the
completed magazine from the machine and put the end covers.
7.2.1.12. Make sure that all required information is completed prior to moving the lot to the next
process step.
7.2.1.13. Prepare the next lot when the last magazine of the lot is at the input elevator.
7.2.1.14. Procedure operation for machine to be set for automatically segregate successive
production lots.
7.2.1.14.1. When the “In L/F – Monitor” in the panel shows the same number as the “In
L/F – Set”, the “Stop” button in the panel will blink to indicate end-of-the-lot
at the input section.
7.2.1.14.2. Open the on loading window and take out the empty FOL magazine. Then
st
load next lot and close the window and wait until 1 magazine load on the
magazine elevator.
7.2.1.14.3. Reset the “In L/F-Set” by pressing button <ENTER>, <0>, <ENTER>
consecutively. After “In L/F” Monitor change, press <ENTER>, <Type
number of strip per PT>, <ENTER> consecutively.
7.2.1.14.4. The strips indicator in the monitor display will change color to indicate
processing of the new lot. The monitor will indicate “Lot End” when the
preceding lot is completed and the last strip is unloaded into the output
magazine.
7.2.1.14.5. Unload molded strip magazine form off load magazine and remove dumm
substrate if any.
7.2.2.1. Proceed with normal production only after all the requirements under item 7.1 are met.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 13 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
7.2.2.2. Add appropriate dummy strip to the lot to make the total number of strips divisible by
two on the last lot to be processed. Before molding, the dummy strip must be identified
by red marker around the mold cap outline. Make sure the mold caps will not cover the
mark.
7.2.2.3. Load maximum of four (4) magazines at the on-load station. See auxiliary procedure –
On-loading Procedure of Magazines.
7.2.2.4. Load maximum of four (4) empty magazines at the off-load station. See auxiliary
procedure – On-loading Procedure of Magazines.
7.2.2.5. Check the machine auto system and choose the correct module that will be used for
production.
7.2.2.6. Run the machine in Automatic Mode by the following actions according to the machine
being used. The machine indicator with green background is the active machine. Call
Technician to change the mold machine to be activated if necessary. Make sure the
machine is in production mode. The mode is display on top on screen with “Normal
Production”. Press <Start> button to start the process.
NOTES:
Machine will require BGA Compensation to adjust the substrate thickness. Press <0>
button and enter if the strip thickness is as same as the previous shot. If the strip is
different thickness with previous shot, make sure use dummy substrate with the same
part number was used for lot.
7.2.2.7. When it is necessary to stop the machine after the current shot, press <HALT> button
and to resume production press <RUN> button.
7.2.2.8. While the machine is in production mode, perform monitoring according to the
requirements described in Total Control Methodology (TCM).
7.2.2.9. When the last slot of the output magazine is filled, the machine will automatically eject
the magazine.
7.2.2.10. After completion of the lot, completely fill up the PT. At the input magazine, remove the
completed magazine from the machine and put the end covers.
7.2.2.11. Make sure that all required information are completed prior to moving the lot to the next
process step.
7.2.2.12. Prepare the next lot when the last magazine of the lot is at the input elevator.
7.2.2.13. Procedure operation for machine to be set for automatically segregate successive
production lots.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 14 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
7.2.2.13.1. Option 1 is by load the magazines for the existing lots. After push the last
strip of magazine, machine assume it is the last strip of lot and will entered
as last strip on the off load magazine. After entered of the last strip on the
magazine, the off-loader will eject the magazine containing the last strip for
the current lot. The next magazine in the on-loader section is assumed to
belong to the next lot. The process is repeated for the succeeding lots.
7.2.3.1.1. Select the <Process Program> from the Cosmo Icon Type Menu window
and then choose “P.P Selection from Process Program Menu window.
7.2.3.1.2. Move the cursor to the desired package type and substrate thickness to be
processed. Select “Assign P.P” and “Save Assignment” to convert the
parameter assignment.
7.2.3.1.3. All molding parameters of each package are pre-programmed and it is not
to be modified without the permission of Process Engineer.
7.2.3.1.4. Before start of each lot, shift Technician MUST PERFORM CLAMP
CALIBRATION using the production substrate, to ensure the cavity adjuster
value is catered for the correct substrate thickness.
7.2.3.2.1. Prepare the lot to be molded I the trolley. Check the magazine traceability
and make sure it coincides with the data on the Process Traveler (P.T.)
7.2.3.2.2. Open the door of the input buffer on the left side of the machine.
7.2.3.2.3. Pick a magazine and carefully remove both end stoppers. Load a maximum
of 3 magazines on the lower input stage with the arrow pointing inside.
Ensure the magazines sets properly at the inner wall of the stage and the
gold gate is on the right side of operator.
7.2.3.2.4. Load a maximum of 3 empty EOL magazines in the EOL buffer section.
7.2.3.2.5. Select <PROCESSING> from the Cosmo Icon Type Menu Window. The
operation-Type 1 Menu window appears in the screen.
7.2.3.2.6. By pushing <Start Running> button, the “Press Selection Dialogue” will be
displayed then select <All Press Start Running> to begin one shot molding
after pass inspection or QC buy off.
7.2.3.2.7. Press “Inspection” button for monitoring while the machine is continue
running.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 15 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
7.2.3.2.8. Inspect the sample for visual defects under low power microscope per
rejects criteria in Table 1. Stop the machine and inform technician.
7.3.1.2. Ensure that the Servo – Motor for the module to be used is turned on by setting the
corresponding I/O state.
7.3.1.3. Proceed with normal production only after all the requirements under item 7.1 are met.
7.3.1.4. Set the selector switch to “ORIG”, press <CYCLE/MANUAL> and <UP> buttons. Wait
until the machine reached the original or home position or until the light in the selector
switch stops blinking.
7.3.1.5. Press the <SELECTOR SWITCH> until either of the following options light: “CL”, “TR”
and “Cyc”.
7.3.1.7. Load the strips on the chase using the inspection jig and ensure proper orientation and
alignment. The gold gates of the strip are on the gates of the mold cavities and all the
location pins are inside their respective locations holes on the strip. In loading, extra
care must be taken not to touch the wires.
7.3.1.9. Set selector switch to "Cyc" and simultaneously press <CYCLE/MANUAL> and <UP>
buttons. When full clamping is reached as indicated by the full clamp close position (no
gap between top and bottom molds) and a slight upward motion of the top chase,
release the buttons and wait until the curing process is finished, the mold fully opened
and the doors ready for opening.
7.3.1.10. Remove the molded strips and de-gate manually. The de-gating must simulate
machine butterfly action. Extra care must be taken not to bent the strips. It should be
divided into two independent strips by removing the cull. Refer to item 7.3.3 for the
detailed manual degating procedure.
7.3.1.11. Close the doors and repeat 7.3.1.5 to 7.3.1.10 for succeeding shot until the lot is
completed.
7.3.1.12. After completion of the lot, completely fill up the PT. Make sure that all required
information are completed prior to moving the lot to the next process step.
NOTE: Fico AMS-36M2 is only designed to run in automatic mode. Manual loading/unloading
on Fico is not recommended. If auto pick & place unit has a problem and cannot be
fixed within one day, manual molding on Fico automatic molding system (AMS) should
be decided by PE, EE and MFG.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 16 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
7.3.2.1. Ensure that the modules to be used are selected. NOTE: Manual operation mode is
performed using the option for Transfer Cleaning operation. This is done by pressing
<INSTR> button, selection of “Transfer Clean” option and responding accordingly to the
machine inquiry on the user interface (UI) screen.
7.3.2.2. Proceed with normal production only after all the requirements under item 7.1 are met.
7.3.2.3. Load the strip manually on the chase using the manual turntable and substrate-loading
jig
7.3.2.3.1. Load the strips on the manual turntable by carefully pulling the strips from
the edge using duckbill tweezers or equivalent.
7.3.2.3.2. Using the substrate loading jig, transfer the substrates from the manual
turntable to the chase.
7.3.2.3.3. Make sure the strips are completely flat on the bottom mold chase before
loading the pellets.
7.3.2.3.4. In the event of mishandling of strips, affected strips shall be endorsed back
to 3/Opt for re-inspection.
7.3.2.4. Once the strips loaded on chase are already flat, load the molding compound using the
pellet loading jig.
7.3.2.7. Press <HALT> when the machine request for halt action.
7.3.2.8. Open the door and remove the molded strips for manual de-gating (refer to item 7.3.3).
7.3.2.9. Remove debris on the top and bottom chase manually using the vacuum and brush.
NOTE: when cleaning manually using the brush and vacuum, follow the following
procedure. This procedure is necessary before making a mold shot to ensure that the
location pins on the chase will not get damage and the debris is totally removed.
7.3.2.9.1. Clean the top chase first. This is done by scrubbing the entire area of the
chase at 2-3 times using the brush with vacuum port.
7.3.2.9.3. Twist the brush so that it is now facing the bottom mold.
7.3.2.9.4. Then clean the bottom chase. This is done by scrubbing the entire area of
the chase at 2-3 times using the brush with vacuum port.
7.3.2.10. Follow instruction on the User Interface screen for the succeeding shots until the lot is
completed.
7.3.2.11. After completion of the lot, completely fill up the PT. Make sure that all required
information are completed prior to moving the lot to the next process step.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 17 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
a. If manual molding process was performed
b. If machine was re-initialized and molded strip is still on the chase / machine
c. If strip was removed because of machine assist and/or error
7.3.3.1. After mold, put the molded material on top of the jig surface with one strip hanging. The
worktable for manual degating must have an ionizer.
7.3.3.2. Push the hanging strip down using the right hand while the pushing down the other side
of strip and culls against the jig using the left hand. This way must be done subsequent
on every panel (not incidentally).
7.3.3.3. After removing the right molded strip, remove the culls using the right hand while the left
hand pushes the strip against the jig. This way also must be done subsequent on every
panel.
7.3.3.4. Clean the surface of the manual degating jig using damp cloth after every degating
process.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 18 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
7.3.3.5. There are cases that gate remains occur after manual degating, especially if it is
molded using the green compound. In such occasional case, operator must rework and
clean the gate remains by pulling the remaining material carefully with the use of
tweezers.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 19 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
Is there
YES any material for
mold?
NO
Put the machine on
standby mode
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 20 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
General loading requires that the magazine is transferred / handled using both hands as shown
below.
7.4.1.1.1. Remove the end covers one at a time one at a time, with one hand hold the
magazine on the table, the other one pulling up the cover.
7.4.1.1.2. Using two hands to transfer the magazine with production units from the
working table to the machine on load section. Make sure no strip out from
magazine during transfer and the gold gate facing the magazine elevator
(left hand operator when load).
7.4.1.1.5. In the offload section, place maximum of four (4) empty magazines. The
golden gate of strips must be on the left side of operator.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 21 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
7.4.1.2.1. Remove the end covers one at a time one at a time, with one hand hold the
magazine on the table, the other one pulling up the cover.
7.4.1.2.2. Using two hands to transfer the magazine with production units from the
working table to the machine on load section. Make sure no strip out from
magazine during transfer and the gold gate facing the magazine elevator
(face to the machine when load)
7.4.1.2.3. Carefully put the magazines on the on-load plate.
7.4.1.2.4. Put maximum of four (4) magazines
7.4.1.2.5. In the offload section, place maximum of four (4) empty magazines. The
golden gate of strips must be on the left side of operator.
7.4.1.2.6. Magazine orientation should follow illustration specific for Fico Auto-Mold.
7.4.1.3.1. Remove the end covers one at a time one at a time, with one hand hold the
magazine on the table, the other one pulling up the cover.
7.4.1.3.2. Using two hands to transfer the magazine with production units from the
working table to the machine on load section. Make sure no strip out from
magazine during transfer and the gold gate facing the magazine elevator
(right hand operator when load)
7.4.1.3.3. Carefully put the magazines on the on-load plate.
7.4.1.3.4. Put maximum of four (4) magazines
7.4.1.3.5. In the offload section, place maximum of four (4) empty magazines. The
golden gate of strips must be on the left side of operator.
7.4.2.1. Using two hands to transfer the magazine from the machine off-load section into the
working table (output table).
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 22 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
7.4.3.1.1. Make sure no expired or different pellets or compound in any part of the
mold compound feeding system (from Pellet Box, Feeder Bowl, Tracks and
Singulator Block). This can be done by manual removal of pellets and by
machine function. On the machine system menu select "Primary Status".
Turn "On" Discharge option & press start button to automatically discharge
all the pellets in the pellet bowl feeder to a separate container inside the
machine.
7.4.3.1.2. Remove pellet buffer box from the machine and bring to the compound
thawing area. Production supervisor is responsible to assign one operator
who loads the pellet into the pellet buffer box.
7.4.3.1.3. Return the pellet buffer box and pull the pellet stopper to release the pellets
into the pellet buffer.
7.4.3.1.4. Press <LINE AUTO> & <START> button consecutively to load the pellet on
the feeder bowl.
7.4.3.1.5. Fill up the Mold Compound Loading History form (see Appendix 8A).
7.4.3.1.6. Make sure only one mold compound type and size is placed beside the
machine at all times.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 23 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
7.4.3.1.7. Do not mix molding compound off different thawing date/time or of different
vendor lot number in the feeder bowl.
7.4.3.1.8. Deplete first all old compound on the feeder bowl or discharge if in expired
thawing date/time before putting new compound of different thawing
date/time or of different vendor lot number.
7.4.3.2.1. Make sure no expired or different pellets or compound in any part of the
mold compound feeding system (from Pellet Buffer, Feeder Bowl, Tracks
and Singulator Block). This can be done by manual removal of pellets and
by machine function.
7.4.3.2.2. Load pellet directly into the external pellet hopper. Pellet feeding is
automatic when the machine is run in auto-mode.
7.4.3.2.3. Fill up the Mold Compound Loading History form (see Appendix 8A).
7.4.3.2.4. Make sure only one mold compound type and size is placed beside the
machine at all times.
7.4.3.2.5. Do not mix molding compound off different thawing date/time or of different
vendor lot number in the feeder bowl.
7.4.3.2.6. Deplete first all old compound on the feeder bowl or discharge if in expired
thawing date/time before putting new compound of different thawing
date/time or of different vendor lot number.
7.4.3.3.1. Make sure no expired or different pellets or compound in any part of the
mold compound feeding system (from Pellet Box, Feeder Bowl, Tracks and
Singulator Block). This can be done by manual removal of pellets and by
machine function. On the machine system menu select "Operation 1", on
the screen menu, press “Pellet Discharge”.
7.4.3.3.2. Remove pellet buffer box from the machine and bring to the compound
thawing area. Production supervisor is responsible to assign one operator
who loads the pellet into the pellet buffer box.
7.4.3.3.3. Return the pellet buffer box and pull the pellet stopper to release the pellets
into the pellet buffer.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 24 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
7.4.3.3.4. Fill up the Mold Compound Loading History form (see Appendix 8A).
7.4.3.3.5. Make sure only one mold compound type and size is placed beside the
machine at all times.
7.4.3.3.6. Do not mix molding compound off different thawing date/time or of different
vendor lot number in the feeder bowl.
7.4.3.3.7. Deplete first all old on the feeder bowl or discharge if in expired thawing
date/time before putting new compound of different thawing date/time or of
different vendor lot number.
7.4.3.4.2. Mold compound removal control from cold storage is refer to table below :
7.4.3.4.3. Every container of mold compound should bear the “Molding Material
Removal Monitor” sticker.
Opening and removal of pellets should be done inside the cold storage.
The container must be closed again and taped (use packing tape)
properly to ensure it is always closed.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 25 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
Stores should put “Engineering Samples” sticker on the plastic bag upon
withdrawal of the engineering mold compound samples.
7.4.3.4.6. Disposal of expired compound should comply with item 9 (Safety and
Environmental Requirements) and other relevant UNISEM specification.
7.4.4.1. The requirements for mold cleaning and conditioning depends on the condition of the
mold. For these requirements, refer to Table 6.
7.4.4.2. After completion of the minimum requirements in table 6, and the mold cavity surface
still needs further cleaning shots call the attention of the Supervisor or Process
Engineer.
7.4.4.3. For Transfer Cleaning and Transfer Conditioning, the steps are the same as outlined in
“PRODUCTION PROCEDURE FOR SEMI-AUTOMATIC MOLDING – PER MACHINE
MODEL.”
7.4.4.3.1. For each shot, make sure to remove all debris on the mold surface prior to
the next shot. This can be done by using brass picks, brass brush and
vacuum.
7.4.4.4. For Compression Cleaning and Compression Conditioning, the following must be
followed:
7.4.4.4.1. Actual Clamp Tonnage for TOWA should be 15 to 30 tons and should be 7
to 10 for FICO.
7.4.4.4.2. Install bottom chase cover plate/paper frame applicable for the chase being
cleaned or use four (4) pieces of clean regular bond papers or equivalent
material in place of the plate.
7.4.4.4.3. Ask EE support to set corresponding I/O state for compression cleaning.
This is provided in the Operation Manual of each mold machine model.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 26 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
Place compression cleaning sheet (for cleaning) or conditioner sheet
(for conditioning) on the blank paper/paper frame according to the
requirements in table 7.
Set the selector switch to CYC then press <CYCLE/MANUAL> &
<UP> buttons. Press the two buttons simultaneously until the bottom
cavity move up and reached the desired clamp force.
After finished cure time, set on CYC then press once
<CYCLE/MANUAL> & <DOWN> buttons together.
Take the results and clean the cavity using unloader cleaning.
Repeat procedure above on each cleaning cycle.
Set the plunger position must be set to the pellet loading position
(position 14) by selecting the I/O screen <4.1>. Select the transfer
motor of the mold station that needs to be moved. Ex. Station1-
<M812>, Station2-<M822>, Station3-<M832>. This activity requires
technician supervision.
Take the results after finished cure time and clean the cavity with
vacuum brush.
7.4.4.4.6. Clamp or close the mold and wait until the curing time is completed. If the
clamp sensor does not activate during clamping, the mold will not open
automatically. Use manual switches to open the mold after four (4) minutes
from clamping the mold.
7.4.4.4.7. For TOWA, if the clamp pressure does not meet 15-ton minimum
requirement or if the sheet is insufficiently compressed or if the cavities and
runners are not fully covered, call for the attention of supervisor, EE support
or, process engineer.
7.4.4.4.8. For each shot, make sure to remove all debris on the mold surface prior to
the next shot.
7.4.4.5. Perform two dummy shots using molding compound to be used or until the last shot
does not show traces of wax. Presence of wax is characterized by wet-look
appearance on the surface.
7.4.4.6. The last shot will serve as dummy buy-off and must meet all the requirements defined
in table 1.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 27 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
7.4.4.7. Cleaning and conditioning materials handling and storage requirements – applicable for
melamine pellets, conditioner pellets, cleaning sheets and conditioner sheets.
o
7.4.4.7.1. Cleaning and Conditioning materials must be stored at maximum 5 C.
7.4.4.7.3. The cleaning and conditioning materials expire whichever comes first:
7.4.4.7.4. Every container of cleaning and conditioning materials should bear the
“Molding Material Removal Monitor” sticker.
7.4.4.7.5. Disposal of expired cleaning and conditioning materials should comply with
item 9 (Safety and Environmental Requirements) and other relevant
UNISEM specification.
7.4.5.1. The machine is equipped with preset shot counter to alert operator to perform cleaning
shot. Inform technician assigned before resetting the machine. For cleaning frequency
requirements, refer to table 6.
7.4.5.2. After completion of the minimum requirements in table 6 and the mold cavity surface
still needs further cleaning shots call the attention of the Supervisor or Process
Engineer.
7.4.5.3. For Transfer Cleaning and Transfer Conditioning, the steps are the same as outlined in
“PRODUCTION PROCEDURE FOR SEMI-AUTOMATIC MOLDING – PER MACHINE
MODEL.”
7.4.5.3.1. For each shot, make sure to remove all debris on the mold surface prior to
the next shot. This can be done by using brass picks, brass brush and
vacuum.
7.4.5.4. There are 2 types cleaning which are stored in the program of the machine. These are
transfer cleaning type and sheet cleaning (compression) type.
7.4.5.5.4. Place lead frame and melamine cleaning compound per system
instructions.
Note :
Source of lead frames loading can be either direct place onto mold or
from L/F preheater or input buffer using on loader.
Melamine cleaning pellets were placed into the plunger pots using
manual pellets loader
7.4.5.5.5. Close the door and press the two “Press Action” buttons located in front of
machine simultaneously to close the mold and commence the cleaning
cycle.
7.4.5.5.6. Wait until the mold open up after the curing time elapsed then remove the
melamine molded strips.
7.4.5.5.7. Clean the mold tool with mexican brush and with air blow to remove
remaining melamine particle.
7.4.5.5.8. Repeat para 7.4.5.5.2 to 7.4.5.5.7 until the mold tool is cleaned.
7.4.5.5.9. Check thoroughly to ensure all cavities and air vents are clean and free on
any stuck flashes or cured cleaning plastic.
7.4.5.5.10. After the mold is cleaned, perform conditioning shot using mold conditioning
compound using same procedure.
7.4.5.5.11. Perform dummy shot using production molding compound to check the
molded packages are free from any mold cosmetic / external defect.
7.4.5.6.2. Set the curing time refer to table 6 then select “Start” on the screen.
7.4.5.6.3. Place the paper clean and cleaning rubber sheet on the cavities and runner
per system instructions.
7.4.5.6.4. Close the door and press the two “Press Action” buttons located in front of
machine simultaneously to close the mold and commence the cleaning
cycle.
7.4.5.6.5. Wait until the mold open up after the curing time elapsed then remove the
rubber melamine molded strips.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 29 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
7.4.5.6.6. Clean the mold tool with brass brush and with air blow to remove remaining
rubber melamine.
7.4.5.6.7. Repeat para 7.4.5.6.1 to 7.4.5.6.6 until the mold tool is cleaned.
7.4.5.6.8. Check thoroughly to ensure all cavities and air vents are clean and free on
any stuck flashes or cured rubber melamine.
7.4.5.6.9. After the mold is cleaned, perform conditioning shot using compressive
rubber conditioner using same procedure.
7.4.5.6.10. Perform dummy shot using production molding compound to check the
molded packages are free from any mold cosmetic / external defect.
7.4.5.7. Both of cleaning and conditioning method can be mixed each other. For example clean
using rubber sheet melamine and conditioner using transfer conditioning shot or clean
using transfer melamine shot and conditioner using rubber conditioning shot.
7.4.5.8. All mold cleaning parameters are programmed by Engineer in advance. Do not change
any parameters without permission
7.4.5.9. Operator to do mold cleaning if the machine cycle has reached maximum limit of shot
(refer to table 6) or whenever it is necessary depending on the condition of the mold.
7.4.6.1. Machine alarms causing machine stoppage during operation has individual code and
displayed in the Alarm Code read-out on the main control panel or on the monitor
screen. Production operator will call the attention of technical support / maintenance
support personnel if alarm code displayed is related to sensor, jamming and other
alarms related to the machine. Alarms related to materials such as…. Require Input of
Pellet, Empty Magazine, ..etc, will be cleared by the operator without the assistance of
technical personnel.
7.4.6.2. After clearing the alarm or responded properly to the machine request, press
appropriate button (as required by the machine) to confirm to the machine that error has
been fixed.
7.4.7.1. Comply with the required process control / monitor as described the section for Total
Process Control Methodology (TCM). These requirements are translated into the line
and contained in the TCM folder.
7.4.7.2. Comply with any requirement required herein on top of those required in the Total
Control Methodology specification.
7.4.8.1. Make sure no foreign debris on the mold. Use vacuum and other qualified tools to
clean the mold chase section, pre-heater sections and other areas where operator
access is allowed. There must be no objects inside any part or section of the machines
other than its parts that need to be stored in its compartment.
7.4.8.2. Move the clamp until 1/4 to 1/2 inch gap between the top and bottom chases is
observed.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 30 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
7.4.8.3. All un-molded strips or units that are not due for molding must be stored in super dry of
Nitrogen purged cabinet.
7.4.8.4. For TOWA, operator should change the machine’s auto system on disable status.
7.4.9.1. Never touch the good or production strips with bare hands / fingers. Use qualified
tweezers and jig in handling molded and un-molded strips during inspection,loading
onto the mold and removing or inserting into the magazine slots.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 31 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
7.4.10.1.1. The following defects are classified as visually detectable defects: (a) Mold
package voids or pits, (b) foreign material, (c) Incomplete fill (d) Dents, (e)
scratch and (f) Damage substrate.
7.4.10.1.3. Place the strip for inspection on the inspection jig. Use qualified tweezers
in handling the strip. Refer to Strip Handling Procedures.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 32 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
7.4.10.1.4. When reject unit is found, immediately mark the reject unit’s location on
corresponding reject mapping form with visible ”DOT”(●) .
7.4.10.2.1. The following defects are classified as internal defects and are X-Ray
Detectable: (a) Wire sweep, (b) Wires short, (c) Damage wires and (d)
lifted bonds, (e) Internal void.
7.4.10.2.3. Use inspection jig and tweezers in handling the strip. Refer to Strip
Handling Procedures.
7.4.10.2.4. For procedure on X-Ray Machine operation, refer to operation manual for
the model being used.
7.4.10.2.5. For internal void inspection, use MFS-4080 E or Sofray X-Ray machines.
Use the following parameters for better visual quality.
Voltage : 50KV
Current : 100mA
X-Ray Current :
Voltage : 50 KV (disregard the value behind coma or point)
Current : 0.05 mA (maximum allowance noted at machine)
7.4.10.2.6. When reject unit is found, immediately mark the reject unit’s location on
corresponding reject mapping form with visible “DOT”( • ).
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 33 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
7.4.10.3.1. Substrate crack is manifested by the change in solder mask color. The
color changes to whitish. The general guideline for substrate crack criteria
is illustrated in table 1. The photo below is a special / critical response to
excessive mold clamping on the substrate.
7.4.10.3.2. Under 3X magnification, inspect the molded strips for any changes in color
or heavy (unusual) clamping impression. If such manifestation is
observed, verify the existence of substrate crack under 40X minimum
magnification.
7.4.10.3.3. If substrate crack is confirmed, shutdown the machine and inform the
Supervisor and Process Engineer. If no crack is found, continue
processing but inform the Process Engineer.
7.4.10.3.5. After the machine is repaired, each repaired module or chase must be
qualified by inspecting 2 shots under 40X minimum magnification.
7.4.10.4.2. Molded strips (dummy or production strips) are subject to SAT or C-SAM
mapping to detect the interface micro-separation or poor sticking. Those
procedure is done offline and optional as determined by the process
engineer in case-to-case basis.
7.4.10.4.3. If Delamination is detected, stop the machine and inform the Supervisor
and Process Engineer.
7.4.10.5.1. Production operator to take one (1) molded strips from top ,middle and
bottom of filled magazine and do visual inspection under luxo lamp to
check for any external visual mold defects.(Refer to Table 1: Mold Defects
Definition and Criteria).
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 34 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
7.4.10.6. DEPRESSED SUBSTRATE PREVENTIVE ACTION
7.4.10.6.1. Operator must perform manual cleaning and checking the cleanliness of
bottom block before processing of each lot.
7.4.10.7.1. Form A shall be used for wire bond to mold buy –off.This is applicable to all
linear and staggered pad devices of PBGA and FBGA.
7.4.10.7.2. FOL Production is responsible to provide the form and the person who will
fill the form is stated on the form. The filled form shall then be kept by Mold
PE for future reference.
7.4.10.7.3. Wire bond production can only start once it passed WB QC buy off and
WB-Mold buy off.
7.4.10.7.4. Conditions on device which require WB-Mold buy off are as follows:
CONDITION C : New device, wire length >120 mils and linear pad
pitch <80 microns.
CONDITION D : New device, irregular wire lay out and bond pads
row (Special requirement).
7.4.10.8.1. Operator to take one molded lot and check for magazine numbering and
number of strips vs. Process traveler (PT) information.
7.4.10.8.2. Pull out the strip one at a time and inspect for any depressed package /
substrate.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 35 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 36 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
Mixed Molded Any mixing of dummy strips or strips Reject any mixed PBGA, FBGA,
Parts from other lot. molded parts. The LGMA, and
units can be accepted FLIP CHIP
after sorting. As long ARRAY
as there is no mold
compound deviation.
Foreign Material Anything on the package that should not Reject if any foreign PBGA, FBGA,
on Substrate be present by design. Foreign material material on substrate LGMA, and
has thickness. Contamination has no which cannot be FLIP CHIP
thickness. removed. ARRAY
Package This defect is equivalent to wrong mold Reject if package PBGA, FBGA,
Dimension use. Example: use of 0.70mm mold cap dimesion is not within LGMA, and
while the requirement is 0.50mm. the specified FLIP CHIP
dimension per drawing ARRAY
or requirements in the
PT.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 37 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
Mold Voids A hole or more appear on the package 1). Reject if void is FBGA, LGMA,
(External) surface. greater than 10 mils in and FLIP CHIP
any direction on the ARRAY
package surface.
2).Reject for
Bubble/Blister in the
molded or
encapsulated area that
could interfere with the
marking.
Incomplete Fill Any amount of insufficient mold ding Reject for any amount PBGA, FBGA,
compound during process. of incomplete fill LGMA, and
FLIP CHIP
(Use naked eyes) ARRAY
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 38 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
Rough Surface This is similar to cluster of package’s Reject for any amount PBGA, FBGA,
external voids. of clustered pinholes LGMA, and
on the package body FLIP CHIP
caused by lack of ARRAY
compaction.
Exposed Wire Bonding wire exposed out of the Reject for any bonding PBGA,FBGA
package. wire exposed out of and LGMA
the package.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 39 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
I (x1-x2) / 2 I or
I (y1-y2) / 2 I
Reversed Mold This defect is equivalent to misoriented Reject if units do not PBGA
molding. conform to the
appropriate
requirement such as
pin1 orientation, … etc.
Wrong / Expired This defect is a material requirement Reject any wrong or PBGA,FBGA,
/ Different Mold deviation. expired molding LGMA, and
Compound. compound. FLIP CHIP
The different compound is shown on ARRAY
different color of mold cap. (Refer to mold
compound sticker)
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 40 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
Wrong Gating This is misoriented molding where the Reject if units do not PBGA
mold gate does not correspond to the conform to the
gold gate on the unit. appropriate
requirement.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 41 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
Scratch Package Shallow stretch of uneven package Marking area – not PBGA,FBGA,
texture due to sticking. allowed LGMA, and
FLIP CHIP
Other area – 30 mils ARRAY
max.
Broken/Damage An FOL / Wirebond defect where the Reject any broken PBGA,FBGA,
Wire wire is cut at the span. wire. and LGMA
(Detected in X-Ray)
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 42 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
Lifted ball (X-ray) An FOL / Wirebond defect where the Reject any wire PBGA,FBGA,
terminal of the wire on the die is removed from its and LGMA
disconnected. connection on the die
or chip.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 43 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
Lifted wedge An FOL / Wirebond defect where the Reject any wire PBGA,FBGA
(X-ray) terminal of the wire on the substrate removed from its and LGMA
lead is disconnected. connection on the
substrate or lead
finger.
Incomplete Bond An FOL reject where there is missing or Reject any incomplete PBGA,FBGA
/ Extra Wire excess connecting wire. bond or extra wires. and LGMA
(X-ray)
(Use X-Ray Machine)
Wrong Bond (X- This defect is not monitored at mold. Any bonding PBGA,FBGA
ray) This is Wire Bond Lay-out Defect configuration different and LGMA
from the build sheet
requirement is a
reject.
Internal Void Internal void is detectable by SAT,cross Reject if greater than PBGA,FBGA,
sectioning and X-ray machine. 10 mils in any direction LGMA, and
in any part of the FLIP CHIP
package.Multiple voids ARRAY
is not allowed.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 44 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
Wire Sway (X- A group of wires(more than 2 wires) that Reject wire deflection FBGA and
ray) sway/deflect following the compound > 8.0% of wire length LGMA
flow direction. using 25 microns wire
diameter.
Wire Clearance 1 or 2 wires that have changed its curve 1 wire diameter PBGA,FBGA
pattern in any direction that disturbing and LGMA
wire to wire distance.
Misalign bump Bump which not align with the bump Reject for any FLIP CHIP
pads as per showed on the build sheet. misalign bump ARRAY
Missing bump Bump not present on the pads as Reject for any missing FLIP CHIP
shown on the build sheet. bump ARRAY
9.1. Only qualified and certified personnel / operator can operate the machine.
9.2. Never by pass any safety feature of the machine. The machine is equipped with safety curtains and
switches to ensure that the operator is fully protected against any accident and machine mal-functions.
9.3. Wear knitted hand gloves on both hands to protect from burns.
9.4. Operator must wear allowable anti-static uniform before enter to the molding production area.
9.5. Technician must wear blue anti-static uniform before enter to the molding production area.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 45 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
9.6. Avoid inhaling molding compound dust.
9.7. Wash hands thoroughly before consuming any food after handling the molding compound.
9.8. Wear grounding device when handling the strips or production units. The grounding device must have at
least one mega-ohm resistor at the contact with the operator.
9.9. If maintenance or equipment fixing activities on progress, place a bold note in front of the machine
indicating that the machine is under set-up or equipment group.
9.10. Never touch wire-bonded strips. Use prescribed tweezers on the area outside of mold cap outline or
outside the Singulation holes outline or outside the fiducial marks outline.
9.11. Do not stop the press when the cycle is “on” unless necessary. For emergency purposes only, press the
emergency stop on the mold press.
9.12. Do not use any materials and tools other than those specified. Like use of brass material only in clearing
the molds of any sticking debris.
9.13. Do not leave any foreign object inside the mold sections and cabinets. Foreign object means any object
that should not be inside the mold, and this includes even tools and logistics provided for mold process.
9.15. Ensure that the mold is free of any foreign materials, debris. Use vacuum and other prescribed tools to
remove these materials.
9.16. Close the mold leaving about 1 / 2 to 2.0 inch gap with plunger raise up for Towa and Asahi. Mold Fico is
automatically close by system when in standby mode.
9.17. Press emergency stop, motor stop as necessary depending on the machine model. If the mold will not be
used for a long period (more than 2 days), inform the technical support. The technical support personnel /
maintenance personnel may place the machine to appropriate status depending on the requirements on
applicable maintenance specification.
9.18. Dispose waste materials such as cotton gloves, rags, finger cots, papers, tissues and other materials
contaminated with chemicals and other hazardous materials into the hazardous waste container.
9.19. Hazardous waste in liquid form shall be stored and disposed with its original or compatible container
properly labeled and tightly covered.
9.20. Empty containers used for chemicals and other hazardous materials shall be considered as hazardous,
and must be disposed accordingly.
9.21. Non-hazardous materials must be disposed or place into non-hazardous waste container.
9.22. Do not clean tools, other items, or any body parts contaminated with hazardous with hazardous material
into an open drain or sink connected directly into an open drain. These must be cleaned into a sink
connected to a treatment facility, or collected into a container and disposed accordingly.
9.23. Containers of chemicals, solvents, oil, paints, spray wax and other hazardous materials must be covered
tightly when not in use.
9.24. Provide secondary containers on areas with chemicals, oil, paints, solvents and other hazardous materials
for the collection of leaks and spills.
9.25. Immediately contain and clean up spills and leaks of chemicals, oil, paints or other hazardous materials
using absorbent materials. Absorbent materials used shall be considered as hazardous hence shall be
disposed accordingly.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 46 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
9.26. All requirements on Handling of Waste Materials are not stated in this specification. In general, disposal
of waste must comply with any related UNISEM specification.
9.27. Operators in the line must be use different gloves during manual production, especially during take the
compound.
10.0. RESPONSIBILITY
10.1.1. It is the responsibility of Process Engineering to keep this specification updated covering related
improvement, development and changes in procedure, equipment, materials, parameters and
product criteria.
10.1.2. Define and / or develop an effective process control plan and improvement programs geared
towards quality, cost improvement and productivity.
10.2. PRODUCTION
10.2.1. It is the responsibility of Production to ensure that all procedures herein are carried out
accordingly.
10.2.2. Production should ensure that only certified operators perform activities for this specification.
10.2.3. Production operator has the full responsibility to ensure that the lot / material is in good condition
until properly endorsed to next process step. Before touching / moving the production lot / strips,
the operator must be informed first.
10.2.4. Production is responsible to ensure that TCM is properly filled up, neatly kept and complete. This
folder should always be ready for audit activities.
10.4. It is the responsibility of Equipment Engineering to ensure that machines are in good condition and
properly set up as required in the TCM.
10.5. Maintain all equipment operating capabilities and performance to optimum conditions according to
applicable preventive maintenance.
10.7.1. QC/QA should ensure that all requirements stated in this specification are complied by periodic
audit as determined by the QC/QA applicable specifications.
10.8. TRAINING
10.8.1. Training should conduct defined training for BGA mold operators and issue certification as proof
of passing the requirements.
11.1. The Total Control Methodology (TCM) specification is translated into working forms (as below) and
contained in the TCM folder provided in every machine.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 47 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
11.2. The contents of TCM folder must be kept updated. Minimum two weeks (consecutive) data entries should
be maintained in the folder.
11.3. The following are the minimum components or elements of TCM folder.
11.3.1. Total Control Methodology (TCM) Cover Page and List of Elements – Appendix 1
11.3.8. Product OCAP for Wire Sway (Lots before Affected Lot) – Appendix 6C
11.3.11. Process OCAP for Voids, Blister, Incomplete, Surface Roughness – Appendix 6F
11.3.12. Process OCAP for Wire Sway, Wire Short, Damage Wire – Appendix 6G
11.3.13. Process OCAP for Damage Wire, Depressed Wire, Broken Wire– Appendix 6H
11.3.14. Process OCAP for Damage / Color Change Solder Mask – Appendix 6J
12.0. APPENDIX AND TABLES (Note: Printable files in excel and power point kept by process engineer and
production supervisor)
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 48 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
BGA AUTOMOLD TCM LIST
Legend :
G/ERN/Group GOOD / ERN # / Group Example : G / 01122 / X
All checklist and checksheet are filled up correctly Checklist and checksheet are correct,
No missing checklist and checksheet filled up properly and no missing checklist
and checksheet of TCM.
Checked by 01122 group X
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 49 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
SYSTEM #: TOOL #:
AVAILABLE TIME :
AS9093 - ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA, LGA AND FLIP CHIP ARRAY PACKAGES Rev. 03
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED B Y UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 50 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
12.3. APPENDIX 3 – POSITIVE CONTROL (POSITROL) PLAN
AS9093 - ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA, LGA AND FLIP CHIP ARRAY PACKAGES Rev. 03
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED B Y UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 51 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
12.4. APPENDIX 4 – PRODUCTION AND EQUIPMENT RECORDING CHECK SHEET
PRODUCTION & EQUIPMENT RECORDING CHECKSHEET
AREA : MOLD (BGA, LGA, AND FLIP CHIP ARRAY)
SAMPLE SIZE : ACCEPT = 0
DATE : / / (DD/MM/YY) Revision Date : 25 November 2007
PER CONTROL PLAN OTHERWISE ONE MOLD SHOT PER CHASE REJECT = 1
SYSTEM / TOOL NO. :
1. EQUIPMENT, MATERIALS, MONITORING, SHOT COUNTER AND INSPECTION >>>>> TO BE FILLED UP BY OPERATOR
Mold Station Used (1 / 2) / / / / / / / / / / / / /
Mold Station Used (3 / 4) / / / / / / / / / / / / /
PT Number
Sublot Quantity
Package Type
Ball Count
Operator ERN / Grp / / / / / / / / / / / / /
Time Lot Finish
/ / / / / / / / / / / / /
Magazine Out Number / / / / / / / / / / / / /
/ / / / / / / / / / / / /
Package Warpage (Min/Max/Ave) / / / / / / / / / / / / / / / / / / / / / / / / / /
Shot Counter (1 / 2) hourly record / / / / / / / / / / / / /
Shot Counter (3 / 4) hourly record / / / / / / / / / / / / /
B = Buy-off & M = Monitor
Qty Reject
Defect Code
AA - Gate Chip / Chip BA - Voids / Blister BC - Protrusion BL - Misoriented Mold OE - Mold Flash HN - WireSweep OTH - Others
AB - Package Crack BB - Incomplete BD - Rouch/ Pitted BR - Pin1 or Ejector Defect HB - Wire Short FOL - FOL Defects NP - Flash on Pad
2. PRODUCTION LOT BY LOT CHECKLIST >>>>>> TO BE PERFORMED BY OPERATOR
PROD'N LOT BY LOT CHECKLIST (CP / RESULT) :
Items Production Checklist Checkpoint (CP) Result Recording Method
Compound and other material information 1. Substrate Thickness 3. Compound Type / PN 5. Compound Expiration 7. Strip Code 9. Pass previous process G = Pass 1. Production Checksheet References : PT, Compound Sticker, Mold IDs, Control Plan
Tooling information 2. Mold Cap Height 4. Compound Size 6. Magazine Numbers 8. Strip Count 10. <24 hours elapsed after plasma F = Fail 2. Lot by lot basis
3. ALL CHECKLIST, CHECKSHEET, RECORD OF TCM ELEMENTS MUST BE PROPERLY CHECKED ON SHIFTLY BASIS BY PRODUCTION OPERATOR (EVERY END OF SHIFT) >>>>>> TO BE PERFORMED BY OPERATOR
TCM CHECKLIST AND RECORD STATUS / / / / / / / / / / / / / / / / / / / / / / / / / /
GUIDANCE LEGEND Recording Method / Frequency
All correct and complete : G / ERN / Group 1. Production & Equipment recording checksheet 3. BGA Automold Shiftly Machine Checklist G. Good TCM 1. Production & Equipment Recording Checksheet
Something wrong with TCM : No / ERN / Group 2. Production Time Ticket and Machine Repair Record 4. Mold Daily - Weekly Mainternance Checklist 2. Every end of shift
4. MOLD CLEANING & CONDITIONING >>>>>> TO BE FILLED UP BY OPERATOR
Start Time
Finish Time
Mold Station Cleaned (1 / 2) / / / / / / / / / / / / /
Mold Station Cleaned (3 / 4) / / / / / / / / / / / / /
Number of Cleaning Shot
Number of Conditioning Shot
5. SET-UP / CONVERSION / MONITOR AND PARAMETERS >>>>>> TO BE FILLED UP BY TECHNICIAN
ITEM RQMT RESULTS
Pellet Pre-heat Time
Hot Plat Temperature
Top Mold Temp. (Min./Max.) / / / / / / / / / / / / /
Bottom Mold Temp. (Min./Max.) Refer to / / / / / / / / / / / / /
Transfer Pressure parameter
Clamp Pressure (Tonnage Setting) board
Transfer Time
Cure Time Setting
Mold Compound Type
Technician ERN
Lead Tech Verification (ERN)
QC STAMP
AS9093 - ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA, LGA AND FLIP CHIP ARRAY PACKAGES Rev. 07
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED B Y UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 52 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
Note : 1. If Reject, Mold production to inform & pass samples to FOL EE/EOL PE immediately
2. If Accept, Mold prodUCtion to inform & pass FORM A to PE Molding for filing
3. For lInear pad devices, do 5.3 dan 5.4. At 5.3, do 3D to verify wire short.
4. For staggered pad devices, do 5.3, 5.4, and 5.5. If 5.5. cannot be done, use X-Ray machine for 3D wire short
(5.5. is required only during 1st to 3rd on line buy off)
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 53 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
Follow Process
A defect is found or Parameter Out of
OCAP according to
Control
Generate Low Yield Report and Relase Defect / Parameter
to next Process
(Resp: Production)
No
No Any defect found ?
Yes
Low Yield ? Yes
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 54 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
12.7. APPENDIX 6B – PRODUCT OCAP FOR WIRE SWAY (AFFECTED LOT)
No
Clearance < 1X wire diameter?
Yes
No
Due to wire bond process?
Yes
Decap the affected unit
S/S : 1 unit
Resp: QC
No
Clearance < 1X wire diameter?
Yes
QC re-sampling PASS?
No
Yes
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 55 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
12.8. APPENDIX 6C – PRODUCT OCAP FOR WIRE SWAY (LOT BEFORE AFFECTED LOT)
Yes
Step (1)
Check the most previous lot or earliest lot
processed that still at Assembly (Use X-Ray)
S/S : 1 mold shot(2 strips) / module
(Resp: Prod'n. / QA.)
Yes
s
Step (3)
Re-screen 100% (Use X-ray)the affected lot and
mark the reject units accordingly
(Resp:Production)
No QC Re-sampling PASS?
S/S : 1 mold shot (2 strips)/module
Yes
Release the lot
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 56 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
NO
NO
NO
NO
NO
Call Engineer
Fill ITR
Resp : EE Tech
NO
QC re-issue ITR Passed QC buy Off ?
YES
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 57 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
12.10. APPENDIX 6E – PROCESS OCAP FOR MISALIGN MOLD
Process OCAP (Out-of-Control Action Plan)
NO
QC re-issue ITR Passed QC buy Off ?
YES
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 58 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
12.11. APPENDIX 6F – PROCESS OCAP FOR EXTERNAL/INTERNAL VOIDS, INCOMPLETE FILL and
Surface Roughness
NO
QC re-issue ITR Passed QC buy Off ?
YES
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 59 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
No
No
Bad IT arm or onloader alignment
to the hot plate or mold?
Yes
Re-teach IT and / or perform
mechanical troubleshooting from
strip pusher to on-mold loading.
(Resp: EE Tech.)
No
Good alignment or
result?
Yes
NO
QC re-issue ITR Passed QC buy Off ?
YES
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 60 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
12.13. APPENDIX 6H – PROCESS OCAP FOR DAMAGE WIRE, DEPRESSED WIRE, BROKEN WIRE
No
No
Bad IT arm or onloader alignment
to the hot plate or mold?
Yes
Re-teach IT and / or perform
mechanical troubleshooting from
strip pusher to on-mold loading.
(Resp: EE Tech.)
No
Good alignment or
result?
Yes
No
NO
QC re-issue ITR Passed QC buy Off ?
YES
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 61 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
12.14. APPENDIX 6J – PROCESS OCAP FOR DAMAGE / COLOR CHANGE SOLDER MASK
Process OCAP (Out-of-Control Action Plan)
No
Clean mold flash and correct mold
Yes chase set up per substrate thickness
Any mold flash on center block?
dimension.
(Resp: EE Tech.)
No
Correct mold chase set up per
Visible heavy clamp Yes
substrate thickness dimension.
impression? (Resp: EE Tech.)
No
Check bare substrate with same
batch/lot number.
(Resp: PE / EE Tech.)
No
Call Engineer
Fill ITR and buy off
Resp : PE / EE Tech
NO
QC re-issue ITR Passed QC buy Off ?
YES
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 62 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
No
Correct handling and / or strip
Any abnormality on Yes alignment on the degater as
handling ordegater? necessary.
(Resp: EE Tech.)
No
Yes
Fill ITR and buy off
Resp : PE / EE Tech
Call Engineer
NO
QC re-issue ITR Passed QC buy Off ?
YES
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 63 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
No
No
No
Replace broken locator pin on
Any broken locator pin or the affected chase / ensure
flexible pin? flexible pin is flexible
(Resp: EE Tech.)
No
NO
QC re-issue ITR Passed QC buy Off ?
YES
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 64 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
AS9093 - ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA, LGA AND FLIP CHIP ARRAY PACKAGES Rev. 02
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED B Y UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 65 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
AS9093 - ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA, LGA AND FLIP CHIP ARRAY PACKAGES Rev. 02
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED B Y UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 66 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
AS9093 - ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA, LGA AND FLIP CHIP ARRAY PACKAGES Rev. 02
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED B Y UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 67 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
SYSTEM:
COMPOUND LOADING THAWING EXPIRATION UNLOADING
NO ERN ERN
TYPE IQA No. DATE TIME DATE TIME DATE TIME
Note :
1. Loading date means time of filling compound to the compound loader.
2. Unloading date means time of removing compound from the compound loader.
3. If undloading date is no record, means the compound is totally used for production.
AS 9093 : ASSEMBLY SFECIFICATION FOR ENCAPSULATION OF BGA (Ball Grid Array) AND LGA (Land Grid Array) PACKAGES
Revision : 02
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 68 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
TOWA, FICO,
64132009 Superwax (SW 9000) 230 x 15 x 5 ALL PACKAGES
ASAHI
5E0000FC FBGA Paper Substrate FBGA 233X62 mm STRIP Towa / Fico / Asahi
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 70 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
Note : The requirement stated both of transfer and compressive are choose one of the type, or mix each other
with same total number of shot.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 71 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
12.26. TABLE 7. MOLD CLEANING AND CONDITIONER SHEETS PLACEMENT.
Strips on the cavity bars must be centered with respect to the cavity bars, and strips on the center
block must be placed right over the pots.
All PBGA
Towa Y-Series / Fico
FBGA 233x62 mm strip
AMS –36 – M2 / 1/1/1 1/1/1 1 / 1/ 1
FBGA 197.5x50 mm strip
Asahi Cosmo
FBGA 234x62 mm stril
Pot
Bushing
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 72 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
12.27. TABLE 8. FICO TRANSFER PARAMETERS TABLE USING EME G760V Size 14mm x 6.3gr
FICO MOLD USING EME G760V or Series of EME G760 Size 14 x 6.3gr
Substrate Pellet
Package Mold Cap Mold Transfer Transfer Transfer Clamping Cure
Ball Package Preheat Preheat
No. Reference Size Height Temp Time Pressure Distance Pressure Time
Count Type Temp Time
(mm) (mm) (deg. C) (deg. C) (sec) (PSI) (mm) (tonF) (sec) (sec)
1. Fico FB01 4.5 x 7.0 0.5 52 FBGA 175 ± 5 175 ± 10 11.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
2. Fico FB01 6.0 x 6.0 0.5 64 FBGA 175 ± 5 175 ± 10 11.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
3. Fico FB01 6.0 x 7.0 0.5 48 FBGA 175 ± 5 175 ± 10 11.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
4. Fico FB01 6.0 x 8.0 0.5 48 FBGA 175 ± 5 175 ± 10 11.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
5. Fico FB01 7.0 x 7.0 0.5 48 FBGA 175 ± 5 175 ± 10 11.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
6. Fico FB01 8.0 x 9.5 0.5 48 FBGA 175 ± 5 175 ± 10 11.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
7. Fico FB01 6.0 x 6.0 0.5 100 FBGA 175 ± 5 175 ± 10 11.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
8. Fico FB01 8.0 x 8.0 0.5 196 FBGA 175 ± 5 175 ± 10 11.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
9. Fico FB17 7.0 x 7.0 0.5 129 FBGA 175 ± 5 175 ± 10 11.6 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
10. Fico FB03 7.0 x 7.0 0.7 64 FBGA 175 ± 5 175 ± 10 9±2 900 - 1300 21 ± 1 30 ± 10 5±5 90
11. Fico FB03 7.0 x 7.0 0.7 72 FBGA 175 ± 5 175 ± 10 9±2 900 - 1300 21 ± 1 30 ± 10 5±5 90
12. Fico FB03 9.9 x 9.9 0.7 140 FBGA 175 ± 5 175 ± 10 9±2 900 - 1300 21 ± 1 30 ± 10 5±5 90
13. Fico FB05 8.0 x 8.0 0.7 64 FBGA 175 ± 5 175 ± 10 8.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
14. Fico FB08 5.5 x 13.5 0.7 96 FBGA 175 ± 5 175 ± 10 12.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
15. Fico FB08 7.0 x 7.0 0.7 49 FBGA 175 ± 5 175 ± 10 12.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
16. Fico FB09 5.5 x 16.0 0.7 114 FBGA 175 ± 5 175 ± 10 9±2 900 - 1300 21 ± 1 30 ± 10 5±5 90
17. Fico FB11 8.0 x 8.0 0.7 64 FBGA 175 ± 5 175 ± 10 13.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
18. Fico FB11 8.0 x 8.0 0.7 81 FBGA 175 ± 5 175 ± 10 13.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
19. Fico FB11 8.0 x 8.0 0.7 145 FBGA 175 ± 5 175 ± 10 13.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
20. Fico FB11 8.0 x 8.0 0.7 196 FBGA 175 ± 5 175 ± 10 13.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
21. Fico FB11 12.0 x 12.0 0.7 196 LGMA 175 ± 5 175 ± 10 13.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
22. Fico FB11 All Size 0.7 ALL FLIP CHIP 175 ± 5 175 ± 10 13.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
23. Fico FB13 15.0 x 15.0 0.7 256 FBGA 175 ± 5 175 ± 10 13.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
24. Fico FB14 13.0 x 13.0 0.7 144 FBGA 175 ± 5 175 ± 10 13.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
25. Fico FB14 13.0 x 13.0 0.7 169 FBGA 175 ± 5 175 ± 10 13.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
26. Fico FB14 13.0 x 13.0 0.7 288 FBGA 175 ± 5 175 ± 10 13.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
27. Fico FB14 13.0 x 13.0 0.7 361 FBGA 175 ± 5 175 ± 10 13.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
28. Fico FB14 14.0 x 14.0 0.7 289 FBGA 175 ± 5 175 ± 10 13.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
29. Fico FB15 15.0 x 15.0 0.7 208 FBGA 175 ± 5 175 ± 10 13.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
30. Fico FB15 15.0 x 15.0 0.7 196 FBGA 175 ± 5 175 ± 10 13.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
31. Fico FB15 15.0 x 15.0 0.7 236 FBGA 175 ± 5 175 ± 10 13.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
32. Fico FB15 15.0 x 15.0 0.7 265 FBGA 175 ± 5 175 ± 10 13.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
33. Fico FB15 15.0 x 15.0 0.7 289 FBGA 175 ± 5 175 ± 10 13.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
34. Fico FB15 17.0 x 17.0 0.7 256 FBGA 175 ± 5 175 ± 10 13.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
35. Fico FB15 17.0 x 17.0 0.7 280 FBGA 175 ± 5 175 ± 10 13.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
36. Fico FB15 17.0 x 17.0 0.7 361 FBGA 175 ± 5 175 ± 10 13.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
37. Fico FB15 19.0 x 19.0 0.7 324 FBGA 175 ± 5 175 ± 10 13.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
38. Fico FB16 13.0 x 15.1 0.5 165 FBGA 175 ± 5 175 ± 10 13 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 90
39. FicoG760V - 1 Generic 0.5 ALL FBGA 175 ± 10 175 ± 10 11.5 ± 6 900 - 1300 21 ± 1 30 ± 10 5±5 90
40. FicoG760V - 2 Generic 0.7 ALL FBGA 175 ± 10 175 ± 10 13.5 ± 6 900 - 1300 21 ± 1 30 ± 10 5±5 90
Note :
1. Generic is applicable for all packages that have no specific setting parameters or new package using above
mold compound
2. Use bottom loading bar vacuum suction.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 73 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
12.28. TABLE 9. FICO TRANSFER PARAMETERS TABLE USING EME 7720TA Size 14mm x 6.2gr
FICO MOLD USING EME 7720TA or Series of EME 7720 SIZE 14 x 6.2gr
Substrate Pellet
Package Mold Cap Mold Transfer Transfer Transfer Clamping Cure
Ball Package Preheat Preheat
No. Reference Size Height Temp Time Pressure Distance Pressure Time
Count Type Temp Time
(mm) (mm) (deg. C) (deg. C) (sec) (PSI) (mm) (tonF) (sec) (sec)
1. Fico FB02 4.5 x 7.0 0.5 52 FBGA 175 ± 5 175 ± 10 11.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 60
2. Fico FB04 7.0 x 7.0 0.7 64 FBGA 175 ± 5 175 ± 10 9±2 900 - 1300 21 ± 1 30 ± 10 5±5 60
3. Fico FB04 7.0 x 7.0 0.7 72 FBGA 175 ± 5 175 ± 10 9±2 900 - 1300 21 ± 1 30 ± 10 5±5 60
4. Fico FB06 8.0 x 8.0 0.7 64 FBGA 175 ± 5 175 ± 10 8.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 60
5. Fico FB07 8.0 x 8.0 0.7 81 FBGA 175 ± 5 175 ± 10 8±2 900 - 1300 21 ± 1 30 ± 10 5±5 60
6. Fico FB10 5.5 x 16.0 0.7 114 FBGA 175 ± 5 175 ± 10 8.5 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 60
6. Fico FB12 5.5 x 13.5 0.7 96 FBGA 175 ± 5 175 ± 10 10 ± 2 900 - 1300 21 ± 1 30 ± 10 5±5 60
7. Fico7720TA - 1 Generic 0.5 ALL FBGA 175 ± 10 175 ± 10 10 ± 6 900 - 1300 21 ± 1 30 ± 10 5±5 60
8. Fico7720TA - 2 Generic 0.7 ALL FBGA 175 ± 10 175 ± 10 10 ± 6 900 - 1300 21 ± 1 30 ± 10 5±5 60
Note :
1. Generic is applicable for all packages that have no specific setting parameters or new package using above
mold compound.
2. Use bottom loading bar vacuum suction.
12.29. TABLE 10. TOWA TRANSFER PARAMETERS TABLE USING EME G760V Size 14mm x 6.3gr
TOWA MOLD USING EME G760V or Series of EME G760 SIZE 14mm X 6.3gr
Substrate Pellet
Package Mold Cap Mold Transfer Transfer Transfer Clamping Cure
Ball Package Preheat Preheat
No. Reference Size Height Temp Time Pressure Distance Pressure Time
Count Type Temp Time
(mm) (mm) (deg. C) (deg. C) (sec) (ton) (mm) (tonF) (sec) (sec)
1. Towa 32 LGMA 13.0 x 13.0 1.1 32 LGMA 175 ± 5 165 ± 25 13 ± 2 0.9 - 1.3 21 ± 1 30 ± 10 5±5 90
2. Towa FB03 4.5 x 7.0 0.5 52 FBGA 175 ± 5 165 ± 25 11.5 ± 2 0.9 - 1.3 21 ± 1 30 ± 10 5±5 90
3. Towa FB03 6.0 x 7.0 0.5 48 FBGA 175 ± 5 165 ± 25 11.5 ± 2 0.9 - 1.3 21 ± 1 30 ± 10 5±5 90
4. Towa FB03 6.0 x 8.0 0.5 48 FBGA 175 ± 5 165 ± 25 11.5 ± 2 0.9 - 1.3 21 ± 1 30 ± 10 5±5 90
5. Towa FB03 7.0 x 7.0 0.5 48 FBGA 175 ± 5 165 ± 25 11.5 ± 2 0.9 - 1.3 21 ± 1 30 ± 10 5±5 90
6. Towa FB03 8.0 x 9.5 0.5 48 FBGA 175 ± 5 165 ± 25 11.5 ± 2 0.9 - 1.3 21 ± 1 30 ± 10 5±5 90
4. Towa FB03 5.0 x 5.0 0.5 64 FBGA 175 ± 5 165 ± 25 11.5 ± 2 0.9 - 1.3 21 ± 1 30 ± 10 5±5 90
5. Towa FB03 6.0 x 6.0 0.5 64 FBGA 175 ± 5 165 ± 25 11.5 ± 2 0.9 - 1.3 21 ± 1 30 ± 10 5±5 90
6. Towa FB03 8.0 x 8.0 0.5 184 FBGA 175 ± 5 165 ± 25 11.5 ± 2 0.9 - 1.3 21 ± 1 30 ± 10 5±5 90
7. Towa FB03 8.0 x 8.0 0.5 196 FBGA 175 ± 5 165 ± 25 11.5 ± 2 0.9 - 1.3 21 ± 1 30 ± 10 5±5 90
8. Towa FB03 6.0 x 6.0 0.5 100 FBGA 175 ± 5 165 ± 25 11.5 ± 2 0.9 - 1.3 21 ± 1 30 ± 10 5±5 90
9. Towa FB03 7.0 x 7.0 0.5 129 FBGA 175 ± 5 165 ± 25 11.5 ± 2 0.9 - 1.3 21 ± 1 30 ± 10 5±5 90
10. Towa FB 008 7.0 x 7.0 0.7 49 FBGA 175 ± 5 165 ± 25 13 ± 2 0.9 - 1.3 21 ± 1 30 ± 10 5±5 90
11. Towa FB 008 5.5 x 13.5 0.7 96 FBGA 175 ± 5 165 ± 25 13 ± 2 0.9 - 1.3 21 ± 1 30 ± 10 5±5 90
12. Towa FB 011 8.0 x 8.0 0.7 81 FBGA 175 ± 5 165 ± 25 12 ± 2 0.9 - 1.3 21 ± 1 30 ± 10 5±5 90
13. Towa FB 011 8.0 x 8.0 0.7 145 FBGA 175 ± 5 165 ± 25 12 ± 2 0.9 - 1.3 21 ± 1 30 ± 10 5±5 90
14. Towa FB 014 8.0 x 8.0 0.7 196 FBGA 175 ± 5 165 ± 25 12 ± 2 0.9 - 1.3 21 ± 1 30 ± 10 5±5 90
15. Towa FB 016 8 x 13 0.5 150 FBGA 175 ± 5 165 ± 25 11.5 ± 2 0.9 - 1.3 21 ± 1 30 ± 10 5±5 90
16. Towa FB 016 5 x 11.5 0.5 96 FBGA 175 ± 5 165 ± 25 11.5 ± 2 0.9 - 1.3 21 ± 1 30 ± 10 5±5 90
17. Towa FB 017 17.0 x 17.0 0.9 256 FBGA 175 ± 5 165 ± 25 13.5 ± 2 0.9 - 1.3 21 ± 1 30 ± 10 5±5 90
18. Towa FB 018 6 x 15 0.5 176 FBGA 175 ± 5 165 ± 25 14 ± 2 0.9 - 1.3 21 ± 1 30 ± 10 5±5 90
19. Towa FB 019 5.0 x 5.0 0.5 56 FBGA 175 ± 5 165 ± 25 11.0 ± 2 0.9 - 1.3 21 ± 1 30 ± 10 5±5 90
20. Towa G760V Generic ALL ALL FBGA 175 ± 5 165 ± 25 11.0 ± 5 0.9 - 1.3 21 ± 1 30 ± 10 5±5 90
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 74 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
Note :
1. Generic is applicable for all packages that have no specific setting parameters or new package using above
mold compound.
2. No bottom loading bar vacuum suction.
12.30. TABLE 11. TOWA TRANSFER PARAMETERS TABLE USING EME G760V Size 14mm x 4.6gr
TOWA MOLD USING EME G760V or Series of EME G760 SIZE 14mm X 4.6gr
Substrate Pellet
Package Mold Cap Mold Transfer Transfer Transfer Clamping Cure
Ball Package Preheat Preheat
No. Reference Size Height Temp Time Pressure Distance Pressure Time
Count Type Temp Time
(mm) (mm) (deg. C) (deg. C) (sec) (ton) (mm) (tonF) (sec) (sec)
1. Towa FB01 4.5 x 7.0 0.5 52 FBGA 175 ± 5 165 ± 25 11.5 ± 2 0.9 - 1.3 15 ± 1 30 ± 10 5±5 90
4. Towa FB04 5.0 x 5.0 0.5 64 FBGA 175 ± 5 165 ± 25 11.5 ± 2 0.9 - 1.3 15 ± 1 30 ± 10 5±5 90
4. Towa FB07 5.5 x 13.5 0.7 96 FBGA 175 ± 5 165 ± 25 12.5 ± 2 0.9 - 1.3 15 ± 1 30 ± 10 5±5 90
5. Towa FB09 ALL 0.5 100 FBGA 175 ± 5 165 ± 25 11.5 ± 2 0.9 - 1.3 15 ± 1 30 ± 10 5±5 90
7. Towa FB 012 9 x 13 0.5 160 FBGA 175 ± 5 165 ± 25 12.5 ± 2 0.9 - 1.3 15 ± 1 30 ± 10 5±5 90
8. Towa FB 013 8.0 x 8.0 0.5 184 FBGA 175 ± 5 165 ± 25 13.0 ± 2 0.9 - 1.3 15 ± 1 30 ± 10 5±5 90
9. TOWA G760V - 1 Generic ALL ALL FBGA 175 ± 5 165 ± 25 12.0 ± 2 0.9 - 1.3 15 ± 1 30 ± 10 5±5 90
Note :
1. Generic is applicable for all packages that have no specific setting parameters or new package using above
mold compound.
2. No bottom loading bar vacuum suction.
12.31. TABLE 12. TOWA TRANSFER PARAMETERS TABLE USING NITTO HC100XJ Size 14mm x 6.2gr
TOWA MOLD USING EME 7720TA or Series of EME 7720 SIZE 14mm X 6.2gr
Substrate Pellet
Package Mold Cap Mold Transfer Transfer Transfer Clamping Cure
Ball Package Preheat Preheat
No. Reference Size Height Temp Time Pressure Distance Pressure Time
Count Type Temp Time
(mm) (mm) (deg. C) (deg. C) (sec) (ton) (mm) (tonF) (sec) (sec)
1 Towa FB 005 8.0 X 8.0 0.7 81 FBGA 175 ± 5 165 ± 25 12 ± 2 0.9 - 1.3 15 ± 1 30 ± 10 5±5 60
2 Towa FB 015 5.5 X 13.6 0.7 96 FBGA 175 ± 5 165 ± 25 12 ± 2 0.9 - 1.3 15 ± 1 30 ± 10 5±5 60
3. Towa 7720TA - 1 Generic 0.5 / 0.7 ALL FBGA 175 ± 5 165 ± 25 12 ± 6 0.9 - 1.3 15 ± 1 30 ± 10 5±5 60
Note :
1. Generic is applicable for all packages that have no specific setting parameters or new package using above
mold compound.
2. No bottom loading bar vacuum suction
12.32. TABLE 13. TOWA TRANSFER PARAMETERS TABLE USING EME 7720TA Size 14mm x 4.5gr
TOWA MOLD USING EME 7720TA SIZE 14mm X 4.5gr
Substrate Pellet
Package Mold Cap Mold Transfer Transfer Transfer Clamping Cure
Ball Package Preheat Preheat
No. Reference Size Height Temp Time Pressure Distance Pressure Time
Count Type Temp Time
(mm) (mm) (deg. C) (deg. C) (sec) (ton) (mm) (tonF) (sec) (sec)
1 Towa FB 002 4.5 x 7.0 0.5 52 FBGA 175 ± 5 165 ± 25 12 ± 2 0.9 - 1.3 15 ± 1 30 ± 10 5±5 60
2 Towa FB 006 5.5 x 13.6 0.7 96 FBGA 175 ± 5 165 ± 25 9±2 0.9 - 1.3 15 ± 1 30 ± 10 5±5 60
3 Towa FB 010 11.0 x 11.0 0.7 100 FBGA 175 ± 5 165 ± 25 12 ± 2 0.9 - 1.3 15 ± 1 30 ± 10 5±5 60
4. Towa 7720TA - 2 Generic 0.5 / 0.7 ALL FBGA 175 ± 5 165 ± 25 12 ± 6 0.9 - 1.3 15 ± 1 30 ± 10 5±5 60
Note :
1. Generic is applicable for all packages that have no specific setting parameters or new package using above
mold compound.
2. No bottom loading bar vacuum suction.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 75 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
12.33. TABLE 14. TOWA TRANSFER PARAMETERS TABLE USING NITTO HC100XJAA Size 14mm x 4.5gr
TOWA MOLD USING NITTO HC100XJAA SIZE 14mm X 4.5gr
Substrate Pellet
Package Mold Cap Mold Transfer Transfer Transfer Clamping Cure
Ball Package Preheat Preheat
No. Reference Size Height Temp Time Pressure Distance Pressure Time
Count Type Temp Time
(mm) (mm) (deg. C) (deg. C) (sec) (ton) (mm) (tonF) (sec) (sec)
1. Towa LG 001 3.0 x 3.0 0.5 9 LGMA 175 ± 5 165 ± 25 11.5 ± 2 0.9 - 1.3 15 ± 1 30 ± 10 5±5 90
2. Towa LG Nitto Generic ALL ALL LGMA 175 ± 5 165 ± 25 11.5 ± 6 0.9 - 1.3 15 ± 1 30 ± 10 5±5 90
Note :
1. Generic is applicable for all packages that have no specific setting parameters or new package using above
mold compound.
2. No bottom loading bar vacuum suction
12.34. TABLE 15. TOWA TRANSFER PARAMETERS TABLE USING EME G760V Size 13mm x 4.9gr
TOWA MOLD USING EME G760V or Series of EME G760 SIZE 13mm X 4.9gr
Substrate Pellet
Package Mold Cap Mold Transfer Transfer Transfer Clamping Cure
Ball Package Preheat Preheat
No. Reference Size Height Temp Time Pressure Distance Pressure Time
Count Type Temp Time
(mm) (mm) (deg. C) (deg. C) (sec) (ton) (mm) (tonF) (sec) (sec)
1. TOWA PB 001 23 x 23 1.17 ALL PBGA 175 ± 5 165 ± 25 11.5 ± 2 0.9 - 1.3 19 ± 1 30 ± 10 5±5 90
2. TOWA PB 002 27 x 27 1.17 ALL PBGA 175 ± 5 165 ± 25 11.5 ± 2 0.9 - 1.3 19 ± 1 30 ± 10 5±5 90
12.35. TABLE 16. TOWA TRANSFER PARAMETERS TABLE USING EME G760V Size 16mm x 8.5gr
TOWA MOLD USING EME G760V or Series of EME G760 SIZE 16mm X 8.5gr
Substrate Pellet
Package Mold Cap Mold Transfer Transfer Transfer Clamping Cure
Ball Package Preheat Preheat
No. Reference Size Height Temp Time Pressure Distance Pressure Time
Count Type Temp Time
(mm) (mm) (deg. C) (deg. C) (sec) (ton) (mm) (tonF) (sec) (sec)
1. TOWA PB 003 35 x 35 1.17 ALL PBGA 175 ± 5 165 ± 25 11.5 ± 2 0.9 - 1.3 19 ± 1 30 ± 10 5±5 90
2. TOWA PB 004 40 x 40 1.17 ALL PBGA 175 ± 5 165 ± 25 11.5 ± 2 0.9 - 1.3 19 ± 1 30 ± 10 5±5 90
12.36. TABLE 17. ASAHI TRANSFER PARAMETERS TABLE USING EME G770 Size 14mm x 5.8gr
ASAHI MOLD USING EME G770 Series Size 14mm x 5.8gr
L/F PHT Pellet
Package Temp of Mold Clamping Injection Package Transfer Cure
Ball Package on L/F loading
No Process Program Name Size L/F Heater Temperture Force Time Pressure Distance Time
Count Type Heater delay time
(mm) (deg. C) (sec) (sec) (deg. C) (ton) (sec) (kgf/cm2) (mm) (sec)
1. BC256_CBGA_0.7t_LF0.36mm ALL 256 FBGA 100 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 6.6 ± 2 70 ± 10 31.5 ± 1 85
2. BC256_CBGA_0.7t_LF0.58mm_vacuum ALL 256 FBGA 120 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 10.3 ± 2 70 ± 10 31.5 ± 1 85
3. BC256_CBGA_0.7t_LF0.58mm ALL 256 FBGA 120 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 6.8 ± 2 70 ± 10 31.5 ± 1 85
4. BF208_CBGA_0.7t_LF0.36mm_vacuum ALL 208 FBGA 100 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 10 ± 2 70 ± 10 31.5 ± 1 85
5. BF208_CBGA_0.7t_LF0.36mm ALL 208 FBGA 100 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 6.6 ± 2 70 ± 10 31.5 ± 1 85
6. BF208_CBGA_0.7t_LF0.58mm_vacuum ALL 208 FBGA 120 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 10 ± 2 70 ± 10 31.5 ± 1 85
7. BF208_CBGA_0.7t_LF0.58mm ALL 208 FBGA 120 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 7.5 ± 2 70 ± 10 31.5 ± 1 85
8. BF96_CBGA_0.7t_LF0.36mm_vacuum 5.5 x 13.5 96 FBGA 100 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 10 ± 2 70 ± 10 31.5 ± 1 85
9. BF96_CBGA_0.7t_LF0.36mm 5.5 x 13.5 96 FBGA 100 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 7.1 ± 2 70 ± 10 31.5 ± 1 90
Legend
L/F = Leadframe PHT = Pre-Heat Time
Note :
1. Except specified on the program name, Mold compound is applicable for EME G770, EME G770LG, EME G770SF and Nitto GE100LFCSV
2. Mold Compound Size 14mm x 5.8gr is applicable for Mold Cap Height 0.7 mm, The rest packages are use size 14mm x 4.7gr
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 76 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
12.37. TABLE 18. ASAHI TRANSFER PARAMETERS TABLE USING EME G770 Size 14mm x 4.7gr
ASAHI MOLD USING EME G770 Series Size 14mm x 4.7gr
L/F PHT Pellet
Package Temp of Mold Clamping Injection Package Transfer Cure
Ball Package on L/F loading
No Process Program Name Size L/F Heater Temperture Force Time Pressure Distance Time
Count Type Heater delay time
(mm) (deg. C) (sec) (sec) (deg. C) (ton) (sec) (kgf/cm2) (mm) (sec)
1. BB416_PBGA_27x27_Thick 27x27 416 PBGA 120 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 8±2 70 ± 10 31.5 ± 1 90
2. BG119_PBGA_14x22_Thick 14x22 119 PBGA 120 ± 20 20 - 40 0 - 40 180 ± 5 30 ± 10 8.5 ± 2 70 ± 10 28.0 ± 1 100
3. BG272_PBGA_27x27_Thick 27x27 272 PBGA 120 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 8 ±2 70 ± 10 28.0 ± 1 90
4. BVG52_CBGA_0.5t_LF0.21mm_vacuum 4.5 x 7.0 52 FBGA 70 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 8.6 ± 2 70 ± 10 28.0 ± 1 85
5. BVG52_CBGA_0.5t_LF0.21mm 4.5 x 7.0 52 FBGA 70 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 6.2 ± 2 70 ± 10 28.0 ± 1 85
6. PBGA_14x22_Thin 14x22 Generic PBGA 120 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 6.8 ± 2 70 ± 10 28.0 ± 1 90
7. PBGA_27x27_Thin 27x27 Generic PBGA 120 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 6.8 ± 2 70 ± 10 28.0 ± 1 90
Legend
L/F = Leadframe PHT = Pre-Heat Time
Note :
1. Except specified on the program name, Mold compound is applicable for EME G770, EME G770LG, EME G770SF and Nitto GE100LFCSV
2. Mold Compound Size 14mm x 5.8gr is applicable for Mold Cap Height 0.7 mm, The rest packages are use size 14mm x 4.7gr
12.38. TABLE 19. ASAHI TRANSFER PARAMETERS TABLE USING SHINETSU KMC3580 Series Size
14mm x 5.8gr
ASAHI MOLD USING SHINETSU KMC3580 Series Size 14mm x 5.8gr
L/F PHT Pellet
Package Temp of L/F Mold Clamping Injection Package Transfer Cure
Ball Package on L/F loading
No Process Program Name Size Heater Temperture Force Time Pressure Distance Time
Count Type Heater delay time
(mm) (deg. C) (sec) (sec) (deg. C) (ton) (sec) (kgf/cm2) (mm) (sec)
1. BC256_CBGA_0.7t_LF0.36mm_vacuum_Shinetsu ALL 256 FBGA 100 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 10 ± 2 70 ± 10 31.5 ± 1 85
2. BC256_CBGA_0.7t_LF0.58mm_vacuum_Shinetsu ALL 256 FBGA 120 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 10 ± 2 70 ± 10 31.5 ± 1 85
3. BC256_CBGA_0.7t_LF0.58mm_Shinetsu ALL 256 FBGA 120 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 6.8 ± 2 70 ± 10 31.5 ± 1 85
4. BF208_CBGA_0.7t_LF0.36mm_vacuum_Shinetsu ALL 208 FBGA 100 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 10 ± 2 70 ± 10 31.5 ± 1 85
5. BF208_CBGA_0.7t_LF0.36mm_Shinetsu ALL 208 FBGA 100 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 6.6 ± 2 70 ± 10 31.5 ± 1 85
6. BF208_CBGA_0.7t_LF0.58mm_vacuum_Shinetsu ALL 208 FBGA 120 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 10 ± 2 70 ± 10 31.5 ± 1 85
7. BF208_CBGA_0.7t_LF0.58mm_Shinetsu ALL 208 FBGA 120 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 7.5 ± 2 70 ± 10 31.5 ± 1 85
8. BF96_CBGA_0.7t_LF0.36mm_vacuum_Shinetsu 5.5 x 13.5 96 FBGA 100 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 10 ± 2 70 ± 10 31.5 ± 1 85
9. BF96_CBGA_0.7t_LF0.36mm_Shinetsu 5.5 x 13.5 96 FBGA 100 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 7.1 ± 2 70 ± 10 31.5 ± 1 90
Legend
L/F = Leadframe PHT = Pre-Heat Time
Note :
1. Except specified on the program name, Mold compound is applicable for EME G770, EME G770LG, EME G770SF and Nitto GE100LFCSV
2. Mold Compound Size 14mm x 5.8gr is applicable for Mold Cap Height 0.7 mm, The rest packages are use size 14mm x 4.7gr
12.39. TABLE 20. ASAHI TRANSFER PARAMETERS TABLE USING SHINETSU KMC3580 Series Size
14mm x 4.7gr
ASAHI MOLD USING SHINETSU KMC3580 Series Size 14mm x 4.7gr
L/F PHT Pellet
Package Temp of L/F Mold Clamping Injection Package Transfer Cure
Ball Package on L/F loading
No Process Program Name Size Heater Temperture Force Time Pressure Distance Time
Count Type Heater delay time
(mm) (deg. C) (sec) (sec) (deg. C) (ton) (sec) (kgf/cm2) (mm) (sec)
1. BB416_PBGA_27x27_Thick_Shinetsu 27x27 416 PBGA 120 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 8±2 70 ± 10 31.5 ± 1 90
2. BG119_PBGA_14x22_Thick_Shinetsu 14x22 119 PBGA 120 ± 20 20 - 40 0 - 40 180 ± 5 30 ± 10 8.5 ± 2 70 ± 10 28.0 ± 1 100
3. BG272_PBGA_27x27_Thick_Shinetsu 27x27 272 PBGA 120 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 8 ±2 70 ± 10 28.0 ± 1 90
4. BVG52_CBGA_0.5t_LF0.21mm_vacuum_Shinetsu 4.5 x 7.0 52 FBGA 70 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 8.6 ± 2 70 ± 10 28.0 ± 1 85
5. BVG52_CBGA_0.5t_LF0.21mm_Shinetsu 4.5 x 7.0 52 FBGA 70 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 6.2 ± 2 70 ± 10 28.0 ± 1 85
6. PBGA_14x22_Thin_Shinetsu 14x22 Generic PBGA 120 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 6.8 ± 2 70 ± 10 28.0 ± 1 90
7. PBGA_27x27_Thin_Shinetsu 27x27 Generic PBGA 120 ± 20 20 - 40 0 - 40 175 ± 5 30 ± 10 6.8 ± 2 70 ± 10 28.0 ± 1 90
Legend
L/F = Leadframe PHT = Pre-Heat Time
Note :
1. Except specified on the program name, Mold compound is applicable for EME G770, EME G770LG, EME G770SF and Nitto GE100LFCSV
2. Mold Compound Size 14mm x 5.8gr is applicable for Mold Cap Height 0.7 mm, The rest packages are use size 14mm x 4.7gr
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 77 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
12.40. TABLE 21. FICO TRANSFER PARAMETERS TABLE USING NITTO GE100 Series Size 14mm x 6.3gr
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 78 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
12.41. TABLE 22. TOWA TRANSFER PARAMETERS TABLE USING NITTO GE100 Series Size 14mm x 6.3gr
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 79 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
12.42. APPENDIX 9. MOLD PARAMETERS BOARD
MOLD MACHINE :
PACKAGE TYPE :
SYSTEM NO. :
EFFECTIVE DATE :
1. Mold Temperature C
2. Transfer Time Sec
4. Transfer Distance Mm
Acknowledge by: PE EE QA
AS9093 - ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA, LGA AND FLIP CHIP ARRAY PACKAGES Revision : 01
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 80 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
1. Transfer Cleaning Procedure
FOR
FOR FICO
FICO USING
USING PAPER
PAPER LEADFRAME
LEADFRAME
PROCEDURE RESP
1. Select “Transfer Cleaning” mode (Menu 1.3). Optr
Figure 1 Figure 2
5. On menu 5.2, set the pellet loading position <28> to 300. Tech
6. Press RUN to start transfer cleani ng process. Optr
9. Machine will ask “Insert the leadframes and pellets, then press RUN”. Optr
Put the substrates (figure 1) and leadframes (figure 2).
10. Insert the Melamine Pellets into the pot bushing, then press “RUN”. Optr
11. After mold curing, the machine will ask “Remove material from mold(s).
Optr
(Stop=0, Next Cycle=1) then press RUN”.
12. If “0” is selected, machine will go to standby. If “1” is selected,
repeat items 9 and 10 to continue next cleaning process. Optr
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 81 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
2. Magazine Orientation on Fico and Towa Mold
GOLD
GATE
GOLD GA TE
TOWA MOLD ON-LOAD TOWA MOLD OFF-LOAD
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 82 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
3. Manual Molding Procedure on Fico Mold
MANUAL MOLDING PROCEDURE ON FICO MOLD
MANUAL MOLDING PROCEDURE FOR FICO AMS-36M2
PROCEDURE RESP REMARKS
1. Select “Transfer Cleaning” mode (Menu 1.3). Optr Online
2. Check molding parameters if it is set for production use. PE Online
3. Press RUN to start manual molding process. Optr Online
4. Machine will ask “Select leadframe loading m ode (0=Automatic, Optr Online
1=Manual)”, Select “1” to run manual trans fer cleaning m ode.
5. Machine will ask “Select station number to clean (0=Standby, Optr Online
4=All)”, Select appropriate chase to be used then press RUN.
6. Machine will ask “Insert the leadf rames and pellets, then press RUN”. Optr Online
7. Manual loading of substrate: Optr Offline
a. Place the magazine, containing production material,on the
substrate loading table.
b. Using duckbill tweezer, hold the edge of the strip to the table.
Make sure it is properly positioned on the guide pins.
c. Rotate the table 180° and repeat item b.
d. With substrate grippers opened, place the pellet loader on
the table.
e. Close the grippers.
14. Wipe off the mold debris from the degating jig after every degating Optr Offline
process.
15. After mold curing, the machine will ask “Remove material from m old(s ). Optr Online
(Stop=0, Next Cycle= 1) then press RUN”. Remove the material from
chase/s, then press run.
16. Clean the chase/s using vacuum brush or blow gun. Optr Online
17. If “0” is selected, machine will go to standby. If “1” is selected, Optr Online
repeat items 6 - 12 to continue next manual molding process.
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL
Document Number: Revision:
AS9093 A
Page 83 of 83
Title:
ASSEMBLY SPECIFICATION FOR ENCAPSULATION OF BGA,
LGA AND FLIP CHIP ARRAY PACKAGES
REVISION HISTORY
Revision
(ECN#) Effective
Description of Change Originator
/Submission Date
Date
Revise para 7.1.3.6.2 and note – add MFG, EE, PE and QC,
para 7.1.3.6.6 – remove word ‘operators’.
Re-phrase Para 7.1.4.3 – change fr “production must submit
one mold shot of production lot to QC for Buy Off” into “if no
L
external defects are found, the same strips…..”
(BT19006) Raynold V. 7-Dec-06
Insert para & subparas 7.1.4.5 and renumber – ITR issuance
29-Nov-06
and Dis-abling of Mold Tool
Update Attachment 3 (positrol plan) – to align with control
plan
PRINTED VERSION IS UNCONTROLLED UNLESS STAMPED "CONTROLLED COPY" IN RED BY UNISEM DOCUMENT CONTROL