Professional Documents
Culture Documents
TESALYS
Main address
7, rue du Cassé
31240 Saint-Jean (Toulouse)
France
Tel. +33 5 62 10 18 91
info@tesalys.fr
www.tesalys.fr
Head Office
DISTRIBUTED BY:
10–12 boulevard Vivier Merle
Tour Oxygène—World Trade Center
69393 Lyon Cedex 03
France
SIRET 750 475 527 00040 | SIREN 750 475 527 RCS Lyon
OUR AWARDS
Winner
Midinvest 2013
Jury’s prize
Export Award
an innovative company Marco Polo 2016
FRANCE
6 PATENTS
30 MIN TO INACTIVATE YOUR
INFECTIOUS BIOMEDICAL WASTE
8LOG10 MICROBIOLOGICAL EFFICACY
AVAILABLE IN MORE THAN 90 COUNTRIES
Process your infectious
waste on-site
LABORATORIES MEDICAL
INDUSTRY / RESEARCH CENTERS
• Hospital Labs • Medical clinics
• Analytical Labs • Infirmaries
• R&D • Dispensaries
• Microbiology/Virology/ • Veterinary
Bacteriology • Vaccination centers
• Medical devices • Nursing homes/
• Veterinary retirement homes
• Environment • etc.
• Industry
• Food Testing
• etc.
HOSPITALS/ HEMODIALYSIS
CLINICS CENTERS
• Public • Autodialysis centers
• Private • Blood transfusion
• Military clinics
• etc. • etc.
STATE OF THE ART The inactivation and disposal of Faced with all these restrictions, INFECTIOUS Plastic or glass consumables: Petri dishes, test tubes, collection tubes,
SOLUTION FOR infectious waste is not easy: it Tesalys offers innovative solutions to BIOMEDICAL WASTE pipettes, etc.
implies risks for the environment process your infectious healthcare Single-use material: surgical drapes, gauzes, compresses, bandages, etc.
ON-SITE TREATMENT and people. Also, the costs for waste by changing its appearance, Personal protection equipment: gloves, gowns, tapes, coveralls, goggles,
OF BIOHAZARDOUS collection, transportation and reducing its volume and weight and masks, caps, shoe covers, etc.
WASTE incineration are very high (the minimizing the associated risks and Contaminated sharps: needles, syringes, scalpels, lancets, blades, slides, etc.
producer is responsible for the disposal costs. Single-use care kits, plastic or small metal instruments.
disposal of their waste until Single-use surgical instruments.
its complete destruction). This Hemodialysis waste: hemodialysis filters, circuits, etc.
process must comply with various Liquid biohazardous waste or waste containing fluids:
procedures and regulations. blood bags, urine bags, culture media, etc.
Waste from R&D on medical devices—Destruction of prototypes—Protection
of intellectual property.
Anatomical waste, animal carcasses and derived products (according to local
regulations).
STERIPLUSTM A01, A02
integrated system with preliminary DECONTAMINATION :
PROVEN INACTIVATION OF 8 LOG10
shredding and steam sterilization of OF BACTERIAL SPORES A13
your biohazardous waste
A15
WASTE LOADING CHAMBER:
AUTOMATICALLY A16
DECONTAMINATED BY STEAM
REDUCTION OF 8 LOG10
NON-STICK COATING OF HOPPER
OF CONTAMINATION
BY AN AUTOCLAVING
A09 SURFACE
A12
CYCLE OF STEAM
AT 135 °C/275 °F
A01
SHREDDER FEED SYSTEM :
FULLY SEALED, WITH WASTE LEVEL
YOUR INFECTIOUS DETECTION AND PTFE COATING
BIOMEDICAL WASTE
INACTIVATED AND FULL TRACEABILITY SHREDDER TESASHRED™: A03
A23
VIA AN INTEGRATED TRANSFORMS WASTE INTO
C04
EXHAUST AIR
DECONTAMINATED BEFORE
FILTRATION AT 0.2 M
µ
DISPOSED OF DOWN THE DRAIN
THE MOST EFFICIENT The STERIPLUSTM systems from The preliminary shredding phase RESPECTING THE Treating biohazardous waste with Zero dioxin and furan emissions
SHREDDING/ Tesalys are the ideal solution to increases the exposure of the ENVIRONMENT STERIPLUS™ technology is not Low water and electricity
inactivate your biohazardous waste micro-organisms to the sterilizing only an excellent way to prevent consumption
AUTOCLAVING SYSTEM on-site and safely. steam thus reducing the microbial biological risks for people and the Reduction of “waste footprint”
FOR PROCESSING Their integrated shredding system load at the start, up to 8 log10. environment, but it is also an envi- Decontaminated effluent
YOUR BIOHAZARDOUS TESASHRED™ not only reduces This equipment offers a simple, ronmentally friendly choice. discharges
the volume and mass of waste but reliable and compact solution to Clean ambient air by filtration at
WASTE also ensures being fully processed. all types of facilities producing 0.2 μm
biohazardous waste. Energy saving by integrated heat
recovery
Zero chemicals - 100% Water
Reduce the number of trucks on
the road (CO2 emissions)
STEP 1
LOAD
the biohazardous waste in your
STERIPLUS™
AS SIMPLE
AS 1, 2, 3… 1 2 3 STEP 2
PRESS THE START
BUTTON
(Fully automated cycle)
• Shreds into grain sized
confetti ≈1cm
• Decontamination through
saturated steam at
135 °C/275 °F
• Drainage of sterilized
effluents
STEP 3
UNLOAD
the shredded and sterilized solid
waste disposable with ordinary waste.
State-of-the-art
technology, easy to use
TESABAG MANUAL
AUTOCLAVABLE UNLOADING
BASKET
BIOHAZARD BAGS
UNLOADING
TESABOX convenient and ergonomic TESAXTRACTTM
CARDBOARD PATENTED DRAWER AND
CONTAINERS FOR TESANET BAG, SIMPLE
BIOHAZARDOUS AND ERGONOMIC
WASTE
A RANGE OF BAGS TESABAG TESABOX TWO WASTE MANUAL UNLOADING BASKET UNLOADING WITH TESAXTRACT™
AND BOXES FOR AUTOCLAVABLE BIOHAZARD BAGS CARDBOARD CONTAINERS FOR UNLOADING The most economic option consists This is the most simple and
Maximum security bag in BIOHAZARDOUS WASTE of unloading the waste after ergonomic patented unloading
OPTIMAL USE FOR accordance with EU directive Rigid and sealed, with internal
SOLUTIONS processing using a stainless steel system. It includes:
BIOHAZARDOUS 94/62/EC plastic lining unloading basket with non-sticking An extractable drawer-basket
WASTE Does not melt, does not stick 12 l to 46 l useful capacity, PTFE coating which can be removed fixed to the inside of the
Autoclavable & withstands up to adapted to STERIPLUS™ from the machine via a handle. chamber
140°C / 284°F systems A disposable and biodegradable
Compatible with all types of Maximum weight 5/8/15 kg cotton cover for collecting the
steam treatment systems (11/18/33 lbs.) solid waste (TESANET)
Increases the service life of Labeled according to French
the equipment by preventing standard NFX 30–507
sediment Approved for biohazardous
“Biohazard” labeled waste road transport (ADR
Available in red and yellow standard)
La garantie
EVERYTHING IS
de vos DASRI
CONTROLLED
décontaminés
INTERNATIONAL FULL
APPROVALS TRACEABILITY
SCIENTIFICALLY REMOTE
TESTED SURVEILLANCE
AND REMOTE
MAINTENANCE
SCIENTIFICALLY SCIENTIFIC TESTS AND APPROVALS The tests were carried out by the TRACEABILITY AND TRACEABILITY REMOTE SURVEILLANCE AND
PROVEN EFFICIENCY The STERIPLUS™ systems were independent lab Biorisk Expertise MAINTENANCE Printing of a conformity report REMOTE MAINTENANCE
designed specially to respond to and the system has been officially for every cycle Full remote access via Internet
one of the strictest standards for approved by French authorities (LNE As an option, it is also possible: for remote maintenance by
waste decontamination equipment - Laboratoire National d'Essais). The • to identify the operator and the authorized technical personnel
(French standard NFX 30-503-1) technology used in STERIPLUS™, batch number using a bar code
and to WHO recommendations. using a mixture of shredding and reader
The sterilization cycle has been steam sterilization, allows a more • to export the printouts in .pdf
validated according to international efficient decontamination cycle. via USB
standards NF EN 554 and EN ISO The reports for the tests performed
17665-1. are available on request.
ORMITY
NF
CO
French standard for
A06 Stainless steel/PTFE flexible hosing Internet by authorized Spare parts kits
STERIPLUSTM, TESASHREDTM
SUPPLY/REQUIREMENTS and TESAXTRACTTM
are Tesalys brands names.
WATER
Needs Softened water 4-8°TH Softened or drinking quality water Softened or drinking quality water
Consumption 5 to 6 liters/cycle Approx. 10 liters/cycle Approx. 15 liters/cycle
ELECTRICITY
B01,B02,B03 STERIPLUSTM
Needs
Consumption A09 380–400V III N, 50 Hz/60 Hz, 10 kW
2 kWh/cycle
380–400V III N, 50 Hz/60 Hz, 15 kW
4 to 5 kWh/cycle
380–400V III N, 50Hz/60Hz, 20 kW
8 kWh/cycle
DRAIN 32 mm ø internal (heat-resistant) (1.2”) 32 mm ø internal (heat-resistant) (1.2”) 32 mm ø internal (heat-resistant) (1.2”)
STEAM/COMPRESSED AIR Produced by the integrated generator and compressor; no external connection (required A07