ISOPENTANE STABILIZATION FACILITY

Document Code Rev. 0 Pag. 1 of 3


PIPE LIST
MEG-CGC-PRO-LIS-002 Date 7/4/2019

ISOPENTANE STABILIZATION FACILITY

PIPE LIST

0 04/07/19 Approved for construction JCC GAB JDT

B 26/02/19 Issue for client review JCC GAB JDT

A 25/02/19 Issue for interval review JCC GAB JDT

Rev Date Description Elab Rev Appro


ISOPENTANE STABILIZATION FACILITY

Document Code Rev. 0 Pag. 2 of 3


PIPE LIST
MEG-CGC-PRO-LIS-002 Date 7/4/2019

Consecutive
Diameter

P Design
T Design
(OP °C)
Isolate

(barg)

(barg)
(barg)

P Test
Class

TEMP
Fluid

P OP
(°C)
Item From To P&ID

1 3" ISO A1A2 001 IH GPP V-345 (TIE IN 01) AIRCOOLER AC-101 84.3 99.3 3.50 3.85 5.20 MEG-CGC-PRO-PID-001
2 3" ISO A1A2 002 IH 3"-ISO-A1A2-001-IH GPP TO FLARE (TIE IN 02, V-345) 75.1 90.1 2.70 2.97 4.01 MEG-CGC-PRO-PID-001
3 2" ISO A1A2 003 IH AIRCOOLER AC-101 HE-110 75.1 90.1 2.70 2.97 4.01 MEG-CGC-PRO-PID-001
4 2" ISO A1A2 004 IH HE-110 EXISTING PIPE (TIE IN 03) 15.6 30.6 1.90 2.09 2.82 MEG-CGC-PRO-PID-002
5 3" ISO A1A2 005 IH CH-120 HE-110 7 22 1.3 1.43 1.93 MEG-CGC-PRO-PID-003
6 3" ISO A1A2 006 IH HE-110 CH-120 13 28 1.3 1.43 1.93 MEG-CGC-PRO-PID-003
2"-ISO-A1A2-008-IH
7 2" ISO A1A2 007 IH EXISTING PIPE (TIE IN 04) 15.6 30.6 1.72 1.89 2.55 MEG-CGC-PRO-PID-003
2"-ISO-A1A2-009-IH
8 2" ISO A1A2 008 IH 2"-ISO-A1A2-007-IH TK-201 15.6 30.6 1.03 1.13 1.53 MEG-CGC-PRO-PID-003

9 2" ISO A1A2 009 IH 2"-ISO-A1A2-007-IH TK-202 15.6 30.6 1.40 1.54 2.08 MEG-CGC-PRO-PID-003

10 4" ISO A1A2 010 IH TK-201 4"-ISO-A1A2-012-IH 15.6 30.6 1.40 1.54 2.08 MEG-CGC-PRO-PID-003
11 4" ISO A1A2 011 IH TK-202 4"-ISO-A1A2-012-IH 15.6 30.6 1.40 1.54 2.08 MEG-CGC-PRO-PID-003
4"-ISO-A1A2-010-IH 4"-ISO-A1A2-020-IH MEG-CGC-PRO-PID-003
12 4" ISO A1A2 012 IH 15.6 30.6 1.40 1.54 2.08 MEG-CGC-PRO-PID-004
4"-ISO-A1A2-011-IH 4"-ISO-A1A2-021-IH
13 2" ISO A1A2 013 IH TK-201 EJ-201 15.6 30.6 1.40 1.54 2.08 MEG-CGC-PRO-PID-003
14 3" ISO A1A2 014 N RD-201 (TK-201) 3"-ISO-A1A2-015-N 15.6 30.6 1.40 1.54 2.08 MEG-CGC-PRO-PID-003
15 3" ISO A1A2 015 N PSV-201 (TK-201) 4"-ISO-A1A2-019-N 15.6 30.6 1.40 1.54 2.08 MEG-CGC-PRO-PID-003
16 2" ISO A1A2 016 N TK-202 EJ-202 15.6 30.6 1.40 1.54 2.08 MEG-CGC-PRO-PID-003
17 3" ISO A1A2 017 N RD-202 (TK-202) 3"-ISO-A1A2-018-N 15.6 30.6 1.40 1.54 2.08 MEG-CGC-PRO-PID-003
18 3" ISO A1A2 018 N PSV-202 (TK-202) 4"-ISO-A1A2-019-N 15.6 30.6 1.40 1.54 2.08 MEG-CGC-PRO-PID-003

3"-ISO-A1A2-015-N
EXISTING PIPE TO FLARE (TIE IN
19 4" ISO A1A2 019 N 3"-ISO-A1A2-018-N 15.6 30.6 1.40 1.54 2.08 MEG-CGC-PRO-PID-003
05)
3"-ISO-A1A2-027-N
20 4" ISO A1A2 020 IH 4"-ISO-A1A2-012-IH P-300A 15.6 30.6 1.40 1.54 2.08 MEG-CGC-PRO-PID-004
21 4" ISO A1A2 021 IH 4"-ISO-A1A2-012-IH P-300B 15.6 30.6 1.40 1.54 2.08 MEG-CGC-PRO-PID-004
22 4" ISO A1A2 022 IH P-300A 4"-ISO-A1A2-024-IH 15.6 30.6 1.40 1.54 2 MEG-CGC-PRO-PID-004
23 4" ISO A1A2 023 IH P-300B 4"-ISO-A1A2-024-IH 15.6 30.6 3.50 3.85 5 MEG-CGC-PRO-PID-004
4"-ISO-A1A2-022-IH
24 4" ISO A1A2 024 IH EXISTING PIPE (TIE IN 07) 15.6 30.6 3.50 3.85 5.20 MEG-CGC-PRO-PID-004
4"-ISO-A1A2-023-IH
ISOPENTANE STABILIZATION FACILITY

Document Code Rev. 0 Pag. 2 of 3


PIPE LIST
MEG-CGC-PRO-LIS-002 Date 7/4/2019

Consecutive
Diameter

P Design
T Design
(OP °C)
Isolate

(barg)

(barg)
(barg)

P Test
Class

TEMP
Fluid

P OP
(°C)
Item From To P&ID

ISOPENTANE STABILIZATION FACILITY

Document Code Rev. 0 Pag. 3 of 3


PIPE LIST
MEG-CGC-PRO-LIS-002 Date 7/4/2019
Consecutive
Diameter

P Design
T Design
(OP °C)
Isolate

(barg)

(barg)
(barg)

P Test
Class

TEMP
Fluid

P OP
(°C)
Item From To P&ID

25 4" ISO A1A2 025 IH EXISTING PIPE (TIE IN 08) ISOPENTANE TRUCK 15.6 30.6 3.50 3.85 5.20 MEG-CGC-PRO-PID-006
26 11/2" ISO A1A2 026 N TSV-400 3"-ISO-A1A2-027-N 15.6 30.6 1.03 1.13 1.53 MEG-CGC-PRO-PID-005
MEG-CGC-PRO-PID-003
27 3" ISO A1A2 027 N ISOPENTANE TRUCK 4"-ISO-A1A2-019-N 15.6 30.6 1.03 1.13 1.53 MEG-CGC-PRO-PID-005