Professional Documents
Culture Documents
: 45
Problem I
Fuel: Cherokee County, Kansas, Coal
Gas analysis: 〖𝐶𝑂〗 _2 14.2 〖𝑘𝑔〗 _𝐶𝑂2/ 〖𝑘𝑔〗 _𝑓𝑙𝑢𝑒𝑔𝑎𝑠
0.142
= CO = 0.3 〖𝑘𝑔〗 _𝐶𝑂/ 〖𝑘𝑔〗 _𝑓𝑙𝑢𝑒𝑔𝑎𝑠
0.003
〖𝑘𝑔〗 _𝑂2/ 〖𝑘𝑔〗 _𝑓𝑙𝑢𝑒𝑔𝑎𝑠
𝑂_2= 4.3 0.043
Gas analysis:
𝑁_2= 〖𝑘𝑔〗 _𝑁2/ 〖𝑘𝑔〗 _𝑓𝑙𝑢𝑒𝑔𝑎𝑠
0.812 81.2
𝑘𝐽/(𝑘𝑔℃)
𝐶_𝑝𝑔= 1.04
𝐻𝑉= 30294.60705
𝑘𝐽/𝑘𝑔
𝑚_𝑟𝑒𝑓𝑢𝑠𝑒=𝑚 ̇_𝑟𝑒𝑓𝑢𝑠𝑒/𝑚 ̇_𝑓𝑢𝑒𝑙
𝐶_𝑎𝑏=𝐶−𝐶_𝑢 𝐶_𝑢=𝑚_𝑟𝑒𝑓𝑢𝑠𝑒−𝑚_𝑎𝑠ℎ
𝑘𝐽/𝑠
𝑄_2= 9449.94145484751
𝑘𝐽/𝑠
𝑄_3= 415.0337158905
𝑚 ̇_𝑣=9𝐻_2 𝑚 ̇_𝐹
𝑚 ̇_𝑣= 1.28135
𝑘𝐽/𝑠
𝑄_4= 3838.0426339815
𝑄_5=10160𝐶_𝐶𝑂 (2.326275)𝑚 ̇𝐶_𝐶𝑂=𝐶𝑂/(
_𝐹 〖𝐶𝑂〗 _2+𝐶𝑂) 𝐶_𝑎𝑏
𝐶_𝐶𝑂= 0.013247079521464
𝑘𝐽/𝑠
𝑄_5= 852.311757837931
𝑄_6=14600𝐶_𝑢 (2.326275)𝑚 ̇_𝐹
𝑄_6= 7195.3805245
𝑄/𝑄_𝑇
Summary: kW %
𝑄_1= 46808.8833333333 0.567596 56.75961
𝑄_2= 9449.94145484751 0.114588 11.45883
𝑄_3= 415.0337158905 0.005033 0.503262
𝑄_4= 3838.0426339815 0.046539 4.653941
𝑄_5= 852.311757837931 0.010335 1.033498
𝑄_6= 7195.3805245 0.08725 8.724989
𝑄_7=
𝑄_7= 13909.0591046092 0.168659 16.86587
𝑸_𝑻= 82468.652525 1 100
Problem II
Fire-tube boiler Boiler operates at:
Steam @ saturation: 𝑃_𝑠= 2 Mpa 2000 kPa
Feedwater temp. : 𝑡_𝑓𝑤= 105 °C 378.15 K ℎ_𝑠=ℎ @ 2𝑀𝑃𝑎
Shell diameter: 𝐷_𝑠ℎ𝑒𝑙𝑙= 218 cm 2.18 m ℎ_𝑓𝑤=ℎ @105℃
No. of tubes: n= 84
Length: 𝐿_𝑡𝑢𝑏𝑒𝑠= 5.5 m 550 cm Fuel oils HV:
Inside diameter: 𝑑_𝑖= 14.7 cm 0.147 m
Outside diameter: 𝑑_𝑜= 15 cm 0.15 m
Boiler efficiency: 𝜂_𝐵𝑜= 0.85
𝐻𝑆=𝐴_1+𝐴_2+𝐴_3−𝐴_4
𝐴_1=1/2 (𝜋𝐷𝐿)
𝐴_1= 18.83329𝑚^2
𝐴_2=𝜋𝑑_𝑖 𝐿𝑛 𝐴_2= 213.3518𝑚^2
𝐴_3=2/3 ((𝜋𝐷^2)/4) 𝐴_3= 2.488277𝑚^2
𝐴_4= 1.484359𝑚^2
𝐴_4=(𝜋𝑑_𝑜^2 𝑛)/4
𝐻𝑆= 233.189𝑚^2
(1𝑘𝑔/1000𝑔)=
𝑚 ̇_𝑠= 932.7562 𝑔⁄𝑠 0.932756168733333
𝑚 ̇_𝑠= 3357.92220744
C. Rated boiler horsepower:
𝑅𝑎𝑡𝑒𝑑 𝑃𝑜𝑤𝑒𝑟=𝐻𝑆/(1.1 𝑚^2/(𝑏𝑜.ℎ𝑝.))
for fire-tube boiler:
𝑃𝑅= 105.804 %
F. Factor of Evaporation 𝐹𝐸=((ℎ_𝑠−ℎ_𝑓𝑤 ))/(2257 𝑘𝐽/𝑘𝑔 " " )
𝐹𝐸= 1.045348
I. Boiler economy
𝐵𝑜𝑖𝑙𝑒𝑟 𝐸𝑐𝑜𝑛𝑜𝑚𝑦=𝑚 ̇_𝑠/𝑚 ̇_𝐹
𝑘𝐽/𝑘𝑔
43612.5
(3600𝑠/1ℎ𝑟)
𝑘𝑔⁄𝑠
𝑘𝑔⁄ℎ𝑟