You are on page 1of 2

ZEROING

(only in GROSS mode)

The zeroing function allows the recalibration of the D150E


Buttons functions in normal operative mode are indicated by deleting residual weight values on zero.
in black. The D150E is equipped with an auto-zeroing function that
Buttons functions in configuration mode are indicated in deletes remaining values from zero upon starting-up (up
Electronic hanging scale red. to a maximum of 5% of the capacity).
shut off
It is suggested to use the zeroing function only if
the auto-zeroing is not sufficient, and in any case,
never as regular use.
configuration mode /
Operator and maintenance manual confirm zeroing function
To access the zeroing function,
INC button
press one of the side buttons
add to the totalizer
ENTER button The following caption will
appear on the display
enable / disable HOLD
DEC button

show / hide To confirm zeroing press


totalizer
ESC button The following caption will
appear on the display
GROSS / NET

zero / tare / To cancel the operation press


clear totalizer

TOTALIZER’S FUNCTION
(only in NET mode)
GROSS / NET
The totalizer function allows to add in memory the values
zero / tare /
of different weighed samples.
clear totalizer
This memory does not lose its value even if the D150E is
DEC button
turned off (or when batteries run down).
It is possible to visualize or zero at any moment, the total
configuration mode /
of the stored weights.
confirm zeroing function
INC button
To display the total weights value, press
one of the side buttons once
show totalizer /
shut off
The totalizer value will appear on the display (1234 kg in
ESC button
the example) alternating with the following caption
add to the totalizer
power on / ENTER button

The green led flashes once when the weight goes When the totalizer is displayed, it is possible to zero it.
through zero (see TOTALIZER FUNCTION)
To perform this operation, press one of the
The red led flashes repeatedly when the D150E is in side buttons
net weight mode (see GROSS/NET)
The following caption will
appear on the display

to confirm zeroing press

The operative mode allows to quickly perform all D150E’s


main functions. to cancel the operation press
MODEL CAPACITY RESOLUTION
D150E – 1 1000 kg 0.5 kg SWITCH ON/SHUT OFF
To exit the totalizer function, press
D150E - 3 3200 kg 1 kg again one of the side buttons
In order to shut the D150E off, keep one
D150E - 6 6500 kg 2 kg of the side buttons pressed for a few
D150E – 12 12000 kg 5 kg seconds. A weight can be added to the totalizer only if the
D150E is in NET mode
In order to switch the D150E on, keep one of
Batteries 4 x AA 1,5V alkaline or Ni-Mh the side buttons pressed for a few seconds. To add a weight to the total press
Working life 80 hours (with 2300 mA/h batt)
Safety factor 5:1 The D150E has a settable self shut-off function (see
CONFIGURATION MODE paragraph) that shuts off the The flashing message will be
Work temperature from -10 °C to +70 °C
instrument if no button is pressed or if the weight remains visualized on the display until
Case material die-cast aluminium
stable for the set time. the weight will have stabilised.
Weight 5.5 Kg – 7 Kg – 10.5 Kg – 19 Kg
DEVICE NOT SUITABLE FOR LITHIUM BATTERIES
In case of acid leakage, replace batteries immediately BATTERIES STATUS At this point, the message will stop flashing to confirm
that the weight has been added.
Clean thoroughly the batteries bay and wash hands properly in
case of contact with the acid leaked from the batteries When batteries are close to
Remove batteries from the device before disposal running down (2-hours operation), To add another weight it is necessary to perform
Batteries must be disposed of according to regulations in force
the D150E displays the following another tare or for the weight to get back close to
message on screen. zero for approximately one second
WARNING (confirmed by a short flashing of the green LED)
1. The present documentation is an integral part of the instrument At first, the message is flashing, if batteries run down If the above is not performed,
2. These operator instructions must be kept in a proper location, in further, the message becomes stable. when attempting to totalize,
good conditions, so that they can be easily found and available for the following message will be
consultation Under these conditions, the appropriate instrument displayed
3. Should these be misplaced or damaged, a copy of the operation is not guaranteed any longer
documentation will have to be requested from the manufacturer It is suggested to replace the batteries as soon as
4. The instructions contained in this manual do not replace the
possible HOLD FUNCTION
applicable laws’ obligations on safety and accident prevention
norms
The HOLD function allows to “freeze” the displayed weight
5. Scope and utilisation modalities described in this manual are the
only ones permitted by the manufacturer
GROSS/NET value to facilitate the reading should this be unstable (e.g.
6. Possible modifications applied to the hanging scale or to the live-stock weighting).
present document by the manufacturer at a later stage, do not To go from GROSS to NET and vice
imply that the material and/or instructions previously supplied are versa, press one of the side buttons The HOLD function can be used only from a remote
inadequate or insufficient control.
When the D150E is in NET, the red LED flashes.
When the D150E is turned off or batteries are removed,
ADOS S.r.l. By pressing the button on the side of the display,
the GROSS or NET status remains recorded.
Via Lazio 25 - 20090 Buccinasco (Mi) - ITALY based on the gross/net selection, the “frozen”
with the present document declares that this D150E: gross or net weight value will be displayed

- complies with the essential requirements and other


TARE (only in NET mode) (100 kg in the example) alternated by the caption

relative provisions of the following directives: EMC The tare function records the value of the actual weight as
89/336/EC and R&TTE 99/5/EC (only radio version) tare, therefore the net weight value is zero.
- it is designed and manufactured according to all This value remains stored also in case of D150E shutting
requirements set by “Essential Safety Requisites Annex 1” off.
of the EU Directive 98/37 CE named Machinery Directive To exit the HOLD function and to go back
To access the tare function to normal weighting, press the button again
press one of the side buttons
1076-MTUD1502 - Rev.3 Page 1 of 2
The configuration mode allows the displaying and USE SCOPE
modifying D150E's operating parameter values.
The hanging scale is a measuring instrument that is used
To enter in configuration mode, press exclusively to weigh loads.
one of the side buttons It must be used correctly, with care, gently and without
wrenching; when not in use, it must be stored in a
covered and dry place. • avoid rough impacts on the floor or against
The first of the following parameters structures
TIME Damage to the hanging scale, for improper use or
or functions will be visualized on DATe
• do not leave the load suspended to the
display, to go to the following ones, purposes not allowed, can create situations of dynamometer; once weighting is done, the load must
CONF
press the same button again. (function)
serious hazard for people exposed and/or damages be laid down gently
to the work environment. • do not use the dynamometer to drag loads
• lift only when the dynamometer is correctly
To enter one of the functions, press one Only qualified personnel are allowed to use the device. suspended and positioned above the load so that the
of the side buttons once. As regards to these instructions, the manufactures force goes though its carrying axle
declines any responsibility in case of:

1. use of the instrument in a way not conforming with


DATE/TIME EDITING national laws relative to safety and accident prevention
2. use of instrument in a way not conforming to the
To edit the current date and time value, proceed as purpose of destination and to the utilisation instructions
follows. 3. non-authorised modifications
4. improper assembling and/or connection with the lifting
Press the side button until date and time system
to be modified are visualized.

Confirm by pressing the side button MARKING


Markings affixed to the D150E hanging scale include:
• manufacturer’s identification • periodically perform checks and maintenance as
At this point, the two digits of the hour (in case of time
• instrument’s model identification indicated in the following paragraph
change) or the day (in case of date change) will start
flashing. • instrument serial number
(accessible by removing the rear cover)
• maximum capacity identification
CHECKS AND MAINTENANCE
By pressing the side button, it is possible to
move the flashing selection on the two • EC marking
To guarantee correct operation of the D150E, and to take
minute’s (in case of time change) or month’s care that it does not lose its safety requirements, the
digits (in case of date change). Markings must not be removed, it is forbidden to place
following checks must be performed:
other markings on the instrument without the
Once the value to be modified has been manufacturer’s authorisation.
1. STRUCTURAL PRESERVATION STATUS CHECK
selected, press the side button to start editing. Shackles’ contact surfaces and relative pins are

The selected digits will start flashing faster.


OPERATING ENVIRONMENT subject to wear since they are movable and oscillating
elements; examine them carefully and signal possible
Avoid using the D150E in environments with corrosive signs of wear, deformations, stretching, incisions and
and/or abrasive substances. corrosions.
Use this button to increase the value Replace components when the section's reduction
Avoid using the D150E in places where heat exceeds the
value allowed. exceeds 10%.
Avoid using the D150E in environments with explosion
or this button to reduce it 2. GENERAL CHECKS
hazards and/or where it is compulsory to use specific
until the desired value will be reached. Maintenance, cleaning and operative checks
components.
Avoid using the D150E under particularly exacting
conditions that could modify the expected load’s values These checks must be performed monthly
(e.g. very strong wind).
To confirm the new date/time press

or to exit without modifying LOAD TYPOLOGY


repeatedly press
The hanging scale can be used exclusively to weight loads
PARAMETERS EDITING with hooking points suitable to guarantee a safe and
stable grip and whose weight does not exceed the
The D150E dynamometer uses 4 stylus type AA batteries.

instrument's maximum capacity. The following can be used:


The <CONF> function allows to access the following
Avoid lifting unbalanced loads or loads whose
parameters: - 1.5 V disposable alkaline batteries
configuration can change.
<A OFF> Set auto-shut off time Avoid lifting loads with temperatures different from those - Ni-Mh 1,2 V rechargeable batteries
(OFF or from 1 to 10 minutes) allowed.
<A ZER> Enable/disable auto-zero upon start-up Avoid lifting loads classified as hazardous. In case of rechargeable batteries, the working life refers
(ON-OFF) to high capacity batteries (2300 mA/h).

CONTROLS, NEVER CONNECT ANY TYPE OF BATTERY


CHARGER TO THE D150E
INSTALLATION AND USE
RECHARGEABLE BATTERIES MUST BE
• check that the markings correspond to the capacity RECHARGED BY USING AN APPROPRIATE EXTERNAL
of the lifted load CHARGER
By pressing the side buttons it is • the maximum utilisation load must never be
possible to browse the parameters list exceeded To replace the batteries
• the gripping elements to which the dynamometer is a screw driver must be used
Once the wanted parameter has been connected, must be compatible by shape,
selected, it is possible to see its value dimensions, and capacity, and must in any case
by pressing one of the side buttons allow utilisation without deteriorating or damaging To avoid damaging the D150E, it is
once. the eye bolt/shackle and its hook suggested that the following instructions be carefully
• the suspending of the dynamometer and the placing observed:
The parameter value will appear on display alternating of the load on it must always be arranged in such a
with its flashing name. way as to allow proper handling, and forcing or rigid 1. place the D150E on a work surface with the front part
connections among connecting elements must be laid on the table (do not replace the batteries while
To modify the parameter’s value, press the same buttons avoided the D150E is hanging in position)
a second time. 2. with the screw driver, carefully loosen the two screws
fixing the rear cover
At this point, it is possible to use the following buttons to 3. move the cover (holding it in your hands) until the
modify the value: button connector will detach from the battery pack
4. place the cover on the surface and remove the
to increase the value press securing bracket of the batteries pack (using the two
threaded knobs)
to reduce the value press 5. extract the stylus batteries from the pack and replace
with new ones
• use, placing of load and handling, must take place
with care, gently Hanging scale radio version
When the desired value is reached, • avoid handling with rough movements, shocks, high
press one of the following buttons to speeds
save it • avoid handling with small jerks that, owing to
r
dynamic effects, can be dangerous for the load
The internal radio modem works on LPD 868-870 Mhz
or one of the side buttons to exit stability; if possible move at slow speeds
band and the emitted power is max 10 mW
without modifying the value • avoid oscillating the load during handling and sudden
Pay attention a non comunication condition “NOLIN”
changes of direction
signalled by repeater is to be considered (even if
not signalled for HW reasons) as an indication of
low battery condition (repeater or hanging scale
battery). Replace the battery and verify the return
of repeater to normal functioning.

1076-MTUD1502 - Rev.3 Page 2 of 2