L I-BEAM
STRETCH A
C
KEY PLAN
A
-
PLAN - I BEAM
SCALE 1 : 50
REFERENCE DRAWINGS
1. DESIGN IS ACCORDING TO THE KAAR MASTER
PLAN, 25 OCTOBER 2018.
2. FOR DRAWING LIST, REFER TO:
KAAR-COW-PW-IC-STU-FZS-DWG-STR-24103
3. FOR GENERAL NOTES, LEGEND AND
ABBREVIATIONS, REFER TO:
KAAR-COW-PW-IC-STU-FZS-DWG-STR-24107 AND
KAAR-COW-PW-IC-STU-FZS-DWG-STR-24108.
4. FOR GENERAL OVERVIEW PLAN OF ST07 AND
ST08 STRUCTURES, REFER TO:
KAAR-COW-PW-IC-STU-FZS-DWG-STR-24104.
5. FOR ROAD DETAIL REFER DWG. (REV. 01-B).
KAAR-SET-PW-FD-NTU-FZS-DWG-CIV-45202 AND
KAAR-SET-PW-FD-NTU-FZS-DWG-CIV-45203
6. FOR UTILITIES DETAILS REFER DWG. (REV. 01).
KAAR-SET-PW-FD-USW-FZS-DWG-INF-42102 TO
KAAR-SET-PW-FD-USW-FZS-DWG-INF-42138
KEY PLAN:
ST08
SE CO N D RI N G R OA D
PRESS
A EX
MCJ0
MCC 0
UM AL
ME CC QU R
AH A R OA
JE DD D
4 75
GRATING, STEEL FRAME AND
MN1 2
+
6
MN1 0
00 M C09
M0
NORT HROAD
U RA IF R OA D
MN1 1
AB DU LLA H
NORT HROAD
NORT HROAD
CA RP ARK
( BY OTH ERS)
M OSQU E
SOUTH ROAD
AY
PRESSW
MS02
AL MA NS OU R R OA D
AEX
MS03
M ECC
AH
JEDD
SOUTH ROAD
SE CO N D RI N G R OA D
MS01
MS07
SOUTH ROAD
SECTION
MA20
A
M004
MA10
JE DD AH -K AA R
MC0 6
MC0 7
ABDUL LAH URAIF ROAD
MS05
MCL 0
MCM0
HALFEN OR SIMILAR APPROVED
MS09
MS04
M S06
AL MA NS OU R R OA D
MC0 3
0
MC0 MS08
0
M C7
0
MC1
DETAILED BY SUPPLIER.
FIXING SYSTEM TYPE 1 SHALL BE
APPLIED TO ALL I-BEAMS NOTES:
1. DIMENSION : ALL DIMENSION ARE IN MILLIMETERS.
2. LEVELS : ALL LEVELS ARE IN METERS.
3. DO NOT SCALE OFF THE DRAWING.
4. REVIT MODEL :
KAAR-COW-PW-FD-NTU-FZS-MD3-STR-53631.
5. FOR DRAWING LIST, REFER TO:
CL I-BEAM CL I-BEAM
KAAR-COW-PW-IC-NTU-FZS-DWG-STR-24701.
TYPE 1 6. ALL INSERTS MUST BE INSTALLED ON PLANE
SURFACES.
7. CAST-IN METALLIC ITEMS (e.g. CHANNELS
AND ANCHORS) IN RELATION TO FIRE-PROOFING TO
BE CORROSION RESISTANT OR CORROSION
PROTECTED IN ACCORDANCE WITH THE APPROVED
FIRE INSULATION SPECIFICATIONS AND THE
APPROVED CONCRETE SPECIFICATIONS DOC. NOS.
KAAR-COW-PW-FD-PWI-FZS-SPC-CIV-48956
WASHER AND KAAR-COW-PW-FD-PWI-FZS-SPC-CIV-48953.
FOR CAST-IN METALLIC ITEMS NOT RELATED TO
FIREPROOFING ONLY THE CONCRETE SPECIFICATION
APPLY.
8. THE THICKNESS OF THE FIRE PROTECTION BOARDS
IS TO BE DETERMINED BY THE SUPPLIER IN
ACCORDANCE WITH DESIGN REQUIREMENTS.
9. USE STAINLESS STEEL FOR EMBEDMENT.
10. SUPPLIER OF CEILING LINING SYSTEM SHOULD
PROVIDE THEIR DESIGN TO THE DESIGNER AND
U-BRACKET ENGINEER FOR REVIEW BEFORE IMPLEMENTING
ON SITE.
11. REVIEW / APPROVAL OF THIS DRAWING DOES NOT
INCLUDE APPROVAL OF SYSTEM ITSELF.THE
SPECIFICATIONS AND SYSTEM DETAILS ARE
SUBJECT TO REVIEW AND SUBMISSION THROUGH
SEPARATE SUBMISSION OF RELATED
DOCUMENTATION.
12. FIRE RATED LINING AT WALLS AND CEILING SHALL
C SECTION COMPLY WITH CLAUSE 7.3.4 OF NFPA 502 FOR AN RWS
180 MINUTES EXPOSURE.REFER TO KAAR-COW-PW-FD
SUPPORT FRAME FOR FIRE
- SCALE 1 : 5
CEILING LINING AND GRP
-SRU-FZS-REP-FLS-20010
GRP GRATING
(BY OTHERS)
Design Consultant
NOTE:
13. THE VENDOR OF CEILING BOARD SHOULD PROVIDE Drawing Title
NORTH ROAD TUNNEL ST08 - STRETCH A,
U-BRACKET ACCESS FOR FUTURE INSPECTION OF I-GIRDERS. STRUCTURAL DESIGN,
(BY OTHERS) ISSUED FOR CONSTRUCTION
FIRE RATED CEILING LINING SUPPORT FRAME FOR FIRE CEILING TYPICAL DETAIL PRECAST I-BEAM
INSERTS / CAST IN CHANNELS
(BY OTHERS) LINING AND GRP GRATING (BY OTHERS)
Engineers
Proj.Code
B SECTION 1 DETAIL, TYPE 1 Project ID Orig. Phas. Stag. Area Zone Doc. Disc.
Type
Ser.
No.
Scale
AS SHOWN
- SCALE 1 : 10
- SCALE 1 : 5
KAAR COW - PW - IC - NTU - FZS - DWG - STR - 24623 Rev.
AT A1 SIZE
01