You are on page 1of 2

Two way Continuous Slab design

1.0 Input data

fck = 20 N/mm2
fy = 500 N/mm2
Density of Concrete = 25 kN/m3
Assume conc. Cover = 20 mm
Assume Dia. Of Bar = 8 mm
Long span (Ly) = 6.00 m
short span (Lx) = 4.00 m
IS:456:2000 Ly / Lx = 1.50
Annex D Ly / Lx < 2.00 (two way slab)
D1.11 Modification factor = 1.4 (Assumed)

5.2 Depth of slab


IS:456:2000 req. D = 133.89 mm Defletion critera
Clause 24.1 Prov. D = 150.00 mm
Effective d provided = 126.00 mm D - cover - (dia/2)

5.3 Loads on floor slab


1) DL
Self weight = 3.75 kN/m2
Floor finish and Water Proofing = 2.50 kN/m2 (Assumed)
Total DL = 6.25 kN/m2
2) LL
LL = 1.50 kN/m2
Total DL +LL = 7.75 kN/m2
Ultimate load = 11.63 kN/m2

Annex D Type of Panel = Interior panels


Table 26
5.4 Possitive moment at mid span
IS:456:2000
Annex D αx = 0.041
Table 26 αy = 0.024

IS:456:2000 Min. Reinforcement = 151.20 mm2 0.12% bd


Clause 26.5.2.1
5.4.1 Reinforcement parallel to shorter direction

IS:456:2000 Mx = αx *w *lx2 = 7.63 kNm


Annex D Ast Req = 143.28 mm2
D 2.1 bar dia = 8.00 mm
Spacing req = 300.00 mm
Spacing prov. = 150.00 mm
Ast Provi. = 335.10 mm2
5.4.2 Check for Deflection
Pt provided = 0.27 %
IS:456:2000 fs = 123.99 N/mm2
Fig 4 M.F. = 3.78
Actual Span to Depth = 31.75
Allowable span/depth = 98.20 O.K. 26 x M.F

5.4.3 Reinforcement parallel to longer direction

IS:456:2000 My = αy *w *lx2 = 4.46 kNm


Annex D Ast. Req = 82.85 mm2
D 2.1 bar dia = 8.00 mm
IS 456 Spacing req = 200 mm
Cl 26.3.3 Spacing prov. = 150 mm
Ast Provi. = 335.10 mm2

5.5 Negative moment at continuous edge


IS:456:2000
Annex D αx = 0.053
Table 26 αy = 0.032

5.5.1 Reinforcement parallel to shorter direction

Mx = αx *w *lx2 = 9.86 kNm


Ast Req = 186.88 mm2
bar dia = 8 mm
Spacing req = 268.98 mm
Spacing prov. = 150 mm
Ast Provi. = 335.10 mm2

5.5.2 Reinforcement parallel to longer direction

My = αy *w *lx2 = 5.95 kNm


Ast. Req = 111.10 mm2
bar dia = 8 mm
Spacing req = 452.45 mm
Spacing prov. = 150 mm
Ast Provi. = 335.10 mm2

You might also like