The system ia a complete functional package including: DP pumps, water pumps & pipes, slurry booster pumps & pipes, motor control, electrical cables within
the battery limits of the tailings dam. The package shall ensure complete service inside the dam, including movil cranes for DP pump positioning and water piton
to mantain a slurry sump for the submerged pumps operation
Other:
(i) The package shall be complete with all necessary pipes, valves, gauges etc to allow direct connection to power,
and water services as required.
(ii) The unit shall have suitable internal and external protective coatings.
(iii) Instruments/controls shall be contained in a local control panel.
(iv) Electrical services include field ligthting
Utilities
Fresh water required : m³/h Vendor or Contractor to advice
Fresh water presure required : kPa Vendor or Contractor to advice
Process water required : m³/h Vendor or Contractor to advice
Process water pressure required : kPa Vendor or Contractor to advice
Plant Air Pressure Requiered : kPa Vendor or Contractor to advice
Plant Air Requiered : Nm³/h Vendor or Contractor to advice
Instrument Air requiered : Nm³/h Vendor or Contractor to advice
Instrument Air pressure requiered : kPa Vendor or Contractor to advice
Installed power consumptión, per : kW Vendor or Contractor to advice
major component
Total installed power requiered : kW Vendor or Contractor to advice
Total power consumption : kW Vendor or Contractor to advice
Man power (Operation : N° Vendor or Contractor to advice
per 12 hours shifts)
Man power (Maintenance : N° Vendor or Contractor to advice
per 8 hours shifts)
Battery Limits
Inputs Tailing -
Water -
Power -
Remarks: The system include operation and maintenance service on anual basis
The system must feed the tailing to the process plant on regular rate
Reclaim of the lateral tailing wall dam will require aditional earth moving equipment
45244
910-YM-002
t/d 2,833
t/h 197
% 60 Minimun
t/m3 2.80
m³/h 295
L/s 90
% solid 35-50
m³/h 365
m³/min 6 Nominal
local control (one operating , one stand by)
650 to 850 kPa 92 L/s Maximun
local control (one operating , one stand by)
6 m³/min Nominal
local control (one operating , one stand by)
1,000 m
SHEET 2 OF 2
SYSTEM
45244
910-YM-002
OJC 45244-910-FS-DS-002
OJC
OJC
LP REV : P