INSTRUCTION MANUAL
FOR
1
Flow Over Weirs Apparatus FM 02
WARRANTY CERTIFICATE
2
Flow Over Weirs Apparatus FM 02
PURCHASER:
Purchase Contract No:.
Supply of Flow Over Weirs Apparatus Model FM 02
The above instrument is warranted to be free from defects in workmanship and material and if it proves
so defective within calendar months from the date of shipment to the original purchaser, named above it
shall be repaired or replaced free of charge provided
The Purchaser sends promptly to M/s. SCI-TECH ENGINEERING PRIVATE LIMITED
102, Regency, New Link Road, Dahisar (West), Mumbai 400 068. INDIA. , notice of defect and satisfactory
proof thereof as abolishing that the instrument has been properly maintained and operated within the
limits of rated capacity and normal usages, and
Assumes the obligation of all expenses of returning the defective instrument, properly packed to
the Factory at the address given in (a) above, if required.
On parts of products incorporated in the instrument but not manufactured by M/s. SCI-TECH
ENGINEERING PRIVATE LIMITED, this warranty is limited to extending to the
purchaser the same warranty as given by the supplier of such part or products.
This guarantee dose not covers consumable parts such as Bulbs, Fuses, and Rubber Seals etc.
Under the circumstances shall M/s SCI-TECH ENGINEERING PRIVATE LIMITED, have any
liability whatsoever for loss of use or for any indirect or consequential damages.
We can only undertake to send our men to a distance to investigate and put right alleged defects on the
distinct understanding that we are paid for their time and expenses in every case.
M/s. SCI-TECH ENGINEERING PRIVATE LIMITEDdecision about repairing or replacing the
equipment or its parts will be final and binding on all concerned parties.
Unless superseded or in contractual form, this warranty is made expressly in lieu of all the other liabilities
and obligations on our part.
Date: For SCI-TECH ENGINEERING PRIVATE
LIMITED
Place: Mumbai/INDIA
INDEX
3
Flow Over Weirs Apparatus FM 02
1. COMPONENT LIST 7
2. PRECAUTIONS 8
3. INSTALLATION PROCEDURE 9
4. THEORY 11
5. SYSTEM DESCRIPTION 13
6. OPERATIONAL PROCEDURE 15
7. OBSERVATION TABLE 17
9. TROUBLESHOOTING 22
4
Flow Over Weirs Apparatus FM 02
5
Flow Over Weirs Apparatus FM 02
COMPONENT LIST
The apparatus is supplied as an accessory for Hydraulic Bench FM 100 (supplied
6
Flow Over Weirs Apparatus FM 02
PRECAUTIONS
1. Ensure that there is no leakage of water from sides of weir plates after it is fixed
on Hydraulic bench.
2. Before starting the water supply make sure that hook gauge is reset to zero when
3. Ensure to that the hook gauge pointer touches the water surface & does not
immerse in to it.
5. Make sure that water does not over flow the weir under test, adjust the water flow
accordingly.
6. After adjusting the water flow, wait for few minutes so that the flow is stabilized.
7
Flow Over Weirs Apparatus FM 02
INSTALLATION PROCEDURE
1. Kindly remove the all packing material & clean the components with cloth.
2. Visually inspect the components& make sure that there are no damages during
the transit.
6. Mount the Hook & Pointer gauge on the walls of flow channel.
7. Power on the hook gauge & select the millimeter (mm) unit.
8. Fix any one of the weirs on the frame at end of flow channel of Hydraulic Bench
10. Lower the pointer such that it touches lower edge of notch section.
11. As the pointer is resting on the lower edge of notch section, set the reading to
13. Make sure that flow control valve is at-least partially open.
14. Start the pump, water will start flowing through the channel.
15. Adjust the water flow rate & wait till water start flowing over the notch edge.
8
Flow Over Weirs Apparatus FM 02
16. Wait for couple of minutes so that water level becomes steady.
17. Ensure that there is no water leakage from the weir plate.
18. Lower the pointer such that it barely touches the water surface. Record the hook
gauge reading.
19. Change the water flow rate &keep the trainer running for few minutes.
9
Flow Over Weirs Apparatus FM 02
THEORY
Weirs:
When water flows through a channel the flow rate can be measured by using weirs
having a notch section. The water is made to flow through notch and depending up
on the level of water over the notch edge, the water flow rate can be determined.
The various shapes of notch sections include ‘V’ notch, Rectangular, Trapezoidal
etc.
Water Level
2
Q th = × √ 2 g L H 5 /2
3
Where
Q ac
Cd=
Q th
10
Flow Over Weirs Apparatus FM 02
‘V’ Notch
Water Level
8 θ 5 /2
Q th =
15 ()
× √ 2 g tan
2
H
Where
Q ac
Cd=
Q th
SYSTEM DESCRIPTION
11
Flow Over Weirs Apparatus FM 02
The flow over weirs apparatus is designed to demonstrate use of weirs for flow
The apparatus is provided as an accessory to the Hydraulic Bench FM 100 & needs
the same for experimentation. The weir under test is fixed to the flow channel of
Hydraulic Bench with help of knobs. Four different types of weirs are provided for
comparison. A digital hook & pointer gauge is provided for measurement of water
Set of Weirs
Four interchangeable weirs are provided with the apparatus. Three ‘V’ Notch weirs
with different angles of ‘V’ & a Rectangular weir are supplied. Each weir can be
easily mounted on the flow channel of Hydraulic Bench using fixing knobs.
12
Flow Over Weirs Apparatus FM 02
A digital hook gauge with pointer is provided to measure the water level over the
weir. The digital indicator has provision to set the Zero to any position & the
13
Flow Over Weirs Apparatus FM 02
OPERATIONAL PROCEDURE
1. Fill the water into the sump tank of Hydraulic Bench.
4. Mount the Hook & Pointer gauge on the walls of flow channel.
5. Power on the hook gauge & select the millimeter (mm) unit.
6. Fix any one of the weirs on the frame at end of flow channel of Hydraulic Bench
8. Lower the pointer such that it touches lower edge of notch section.
9. As the pointer is resting on the lower edge of notch section, set the reading to
11. Make sure that flow control valve is at-least partially open.
12. Start the pump, water will start flowing through the channel.
13. Adjust the water flow rate & wait till water start flowing over the notch edge.
14. Wait for couple of minutes so that water level becomes steady.
15. Ensure that there is no water leakage from the weir plate.
16. Lower the pointer such that it barely touches the water surface. Record the hook
gauge reading.
14
Flow Over Weirs Apparatus FM 02
18. Change the water flow rate & record the Hook Gauge reading & water flow rate
in each case.
20. Remove the weir plate by removing all the knobs & replace it with other plate.
22. After end of experiment, remove the weirs & hook gauge from hydraulic bench.
15
Flow Over Weirs Apparatus FM 02
OBSERVATION TABLE
Serial
Type of Weir Flow through Hook
No. Weir Gauge
Reading
Qac H
LPM mm
1 Rectangular
16
Flow Over Weirs Apparatus FM 02
CALCULATIONS
1. Rectangular Notch Weir
2
Q th = × √ 2 g L H 5 /2
3
Flow ∈ LPM
Qac=
60
Q ac
Cd=
Q th
8 θ 5 /2
Q th =
15 ()
× √ 2 g tan
2
H
Where
θ = Angle of ‘V’ Notch
Flow ∈ LPM
Qac=
60
Q ac
Cd=
Q th
Q ac
Cd=
Q th
Note:
Alternatively Actual Flow Rate Qac can be calculated by using measuring tank of Hydraulic
Bench FM 100, Kindly refer operational manual for Hydraulic Bench for details.
18
Flow Over Weirs Apparatus FM 02
RESULT TABLE
Qth Qac Cd
m3/sec m3/sec
1 Rectangular
19
Flow Over Weirs Apparatus FM 02
Qac H
LPM mm
1 Rectangular 10 15
30 31
2 ‘V’ Notch – 45˚ 10 34
20 44
Qac Qth Cd
m3/sec m3/sec
1 Rectangular
20
Flow Over Weirs Apparatus FM 02
TROUBLE SHOOTING
Sr. Fault Action/Remarks
No.
1. Hook Gauge does not 1. Check the
indicate reading battery & replace the same if
required.
2 Water leaking from sides of 1. Check the gasket for damage, replace
weir plate if required.