1 kg = 0.

01kN
Length = 39.29 m 1 kN = 100 kg
Width/Span = 11.30 m
Bay spacing = 11.68 m
Clear eave height = 12.48 m
Max. eave height = 14.30 m
Roof slope (θ) = 11.03 ˚
DEAD LOAD (DL)
Wt. of sheet & purline = 15.00 Kg/m²
Dead Load (DL) = 1.75 KN/m

ACCIDENTAL LOAD
Collateral Load on Rafter = 20.00 Kg/m² Other Collateral Load = 20.00 Kg/m²
= 2.34 KN/m = 2.34 KN/m

LIVE LOAD (LL)


Live load/unit area, roof = 150.00 Kg/m²
Live Load (LL) = 17.52 KN/m

WIND LOAD (WL)


Basic wind speed (Vb) = 55 m/s
Design wind speed (Vz) = Vbxk1xk2xk3
where,
k1 = probability factor (risk coefficient)
= 1.08 Terrain Category Class
k2 = terrain, height and structure size factor 2 B
= 1.02
k3 = topography factor
= 1.72
Vz = 104.21136 m/s

Design wind pressure (pz) = 0.6xVz²


pz = 6.516 KN/m²

PRESURE COEFFICIENTS:~
Encloser condition of the building = Open
Internal pressure coeff.(Cpi) = 0.70

h/w = 1.27
= 1/2<h/w<=3/2
l/w = 3.48
= 3/2<=l/w<4
External pressure coeff.(Cpe) : Table 4 Table 5
Wind Angle Coeff. For Wall Coeff. For Roof
(ө)
Left Right Left Right
0 degree 0.70 -0.25 -0.9350 -0.40
90 degree -0.80 -0.80 -0.80 -0.80

WIND LOAD DIAGRAMS:~

Wind Across the Ridge (With -Ve Cpi) Wind Across the Ridge (With +Ve Cpi)
-0.24 -17.89 0.30 22.83 -1.64 -124.435 -1.10 -83.72
KN/m
KN/m KN/m KN/m

106.55 34.25 0.00 -72.30


1.40
KN/m 0.45
KN/m 0.00
KN/m -0.95
KN/m

Wind Parallel to Ridge(With +Ve Cpi)


-1.50 -114.16 -1.50 -114.16

KN/m KN/m

-114.16 -114.16
-1.50
KN/m -1.50
KN/m

Wind Parallel to Ridge(With -Ve Cpi)


-0.10 -7.61 -0.10 -7.61

KN/m KN/m

-7.61 0.00
-0.10
KN/m -0.10
KN/m
Note:
1) Values within the circles are the UDL
2) -Ve value means, load applied
away from structure.