You are on page 1of 59

SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area

PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020


CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020

DESIGN OF FOUNDATION FOR SHIPPER PUMP


SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area

PROJECT DESIGNED BPK DATE 30-01-2020


Juaymah Terminal Onshore
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020

CONTENTS Page no

1 SCOPE ............................................ 3
2 DESCRIPTION ............................................ 3
3 DESIGN BASIS ............................................ 3
4 UNITS OF MESUREMENT ............................................ 3
5 APPLICABLE CODES & STANDARDS ............................................ 3
6 DESIGN OF SHIPPER PUMP FOUNDATION ............................................ 4

APPENDICES

APPENDIX A ............................................
Coefficients for spring constants as per Richart, F.E., Jr., Whitman, R. V.

APPENDIX B ............................................
SOIL REPORT

APPENDIX C ............................................
VENDOR DRAWING

Page 2 of 59
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area

PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020


CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020

1 SCOPE:

The scope of this calculation is to do the dynamic analysis and design of Shipper pump supported on isolated bearing
foundation which is located in Juaymah area of Juaymah Terminal Onshore Project.

2 DESCRIPTION :

The Shipper pump is supported on bearing foundation. Since pump horsepower is 15040 HP > 500 HP (ap per Cl. 5.1.1, SAES-007 )
Dynamic analysis has been carried out to design isolated block foundation.
The dynamic analysis is performed for one shear modulus(1.0 G) value. The dynamic analysis is done based on the Elastic half
space theory approach as described in Design of structures and foundations for vibrating machines by Arya, Pincus and O'Niel.

3 DESIGN BASIS:
3.1 DESIGN PHILOSOPHY:
The foundation system on analysis shall meet the criteria specified in the codal provision ACI-318M-14.
The foundation shall be designed such that the natural frequency of the foundation avoids resonance with the operating speed of
machine. The above shall be applied to all the possible modes of vibration.
The foundation- machine system is analyzed for the interaction with soil by considering appropriate stiffness based on soil
parameters as detailed in the dynamic analysis part.
The Bearing foundation is designed to withstand Vertical ,Lateral load and Longitudinal loads from the Shipper pump.
Foundation are checked for the safe bearing capacities for static and dynamic load.

4 UNITS OF MEASUREMENT:
The International System Units (S.I) are used in this calculation.

In particular, the following units & symbols are considered.


♦ Length Metre m
Millimetre mm
♦ Area Square metre m²
Square millimetre mm²
♦ Volume Cubic metre m³
Cubic millimetre mm³
♦ Force Newton N
kilo Newton kN
♦ Mass kilograms kg
♦ Unit Weight kilo Newton per m³ kN/m³
♦ Pressure kilo Pascal kpa = kN/m²
mega Pascal Mpa = N/mm²
♦ Temperature Degree Celsius °C
5 APPLICABLE CODES & STANDARDS:
ACI 318M - 2014 Building Code Requirements for Structural Concrete with commentary
SAES-Q-007 Saudi Aramco Foundations and Supporting Structures Standard Committee (5th May 2014)
API 686 Recommended Practice for Machinery Installations & Installation Design
ASCE/SEI 7-10 Minimum Design Load for Building and Other Structures

5.1 DESIGN ASSUMPTIONS:

1) Soil stiffness and damping coefficients taken from Richart spring values as per Table 4-1, Design of structures and
foundations for vibrating machines by Arya, Pincus and O'Niel, (Refer Appendix-A).
2) The Dynamic shear modulus G value from geotech report 80000 kN/sqm ref. Soil report Table 11 (2018/40 Rev.3),
crosshole test result-CHT-01 -Shipper pumps.
3) The frequencies and amplitudes are calculated for only one G.

Page 3 of 59
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area

PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020


CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
6.0 DESIGN OF COMPRESSOR FOUNDATION:
STATIC ANALYSIS OF THE PUMP FOUNDATION:
PUMP MOTOR

C/L of the Rotating Eqp

BASE FRAME

Grout 50 mm tk T.O.C EL 0.370


370

H.P.P 0.000
EL
PEDESTAL
0 13080 0
750

FOOTING
BOF
750

EL -1.500

Total = 1870 13080

EL 0.370
370

EL 0.000
750

0 5810 0
750

EL -1.500

5810
Elevation 1

Page 4 of 59
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area

PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020


CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
6.1 Material Data: Concrete
Characteristic compressive strength of concrete fck = 32 N/mm2
Unit weight concrete γc = 25 kN/m3
Concrete cover below grade cover = 75 mm
Reinforcing Steel
Characteristic Strength of Steel fy = 420 N/mm2
Unit weight steel γs = 78.5 kN/m3
Anchor bolts
6.2 Geotechnical Data:

Soil Data
High point of paving (HPP) = 0.000 m
Unit weight of soil γsoil = 18 kN/m3
Allowable bearing pressure ( SBC ) = 130 kN/m2 Page no 5 of
Bearing capacity reduction factor = 75 % Geotechnical File No: 2018/40 Rev.3
Reduced Bearing pressure Pb = 97.5 kN/m2
Dynamic shear modulus of Block foundation Gs = 80000 kN/m2 CHS 04 - Table 11
Poisson ratio ν = 0.35 Geotechnical File No: 2018/40 Rev.3
Friction coefficient between soil & concrete µ = 0.404
Pedestal top = 0.370 m
Grout thickness = 50 mm
Grout unit weight = 20 kN/m3
Factor of safety for sliding = 1.5 As per CL6.5 API RP 686, pg 4-5
Factor of safety for overturning = 1.5 As per CL6.5 API RP 686, pg 4-5

6.3 Loading Data:

Load on the foundation block by pump Shipper is taken from vendor drawing Ref. Vendor Data DEK046054

Base frame size = 11.08 x 4.65 m


Grout weight = (11.08+2*0.1)*(4.65+2*0.1)*0.05*20
= 54.71 kN
Motor weight = 451.26 kN
Pump weight = 269.78 kN
Base frame weight = 235.44 kN
Coupling& misc weight = 0.00 kN
Total weight of assembly = 956.48 kN
Assumed components weight
Pump rotating weight = 0.00 kN 5% CONSIDERED FOR EACH
Driver rotating weight = 0.00 kN PUMP & MOTOR
Speed of Motor = 1800 rpm
= 1800 rpm Ref. Vendor Data DEK046054

Since pump horsepower is 15040 HP > 500 HP (ap per Cl. 5.1.1, SAES-007 ) dynamic analysis is carried out.

Page 5 of 59
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area

PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020


CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020

5810
Axis of Rocking X
5810

PUMP

GEAR BOX
13080
13080

MOTOR

Z Axis of pitching
ORIGIN PLAN VIEW

Axis of Yawing Y

C/L of the Rotating Eqp

2000 T.O.C
EL0.370
H.P.P EL0.000

ORIGIN EL -1.500 Z

5810

SECTION 1-1

Page 6 of 59
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area

PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020


CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
6.4 Anchor Bolt Details:
Total No. of anchor bolts = 30
Anchor Bolt dia = 30 mm
C/C distance between bolts along the length = 770 mm
No of bolts for 770 mm = 15
C/C distance between bolts along the length = 0 mm
No of bolts for 0 mm = 0
C/C distance between far end bolts along the length La = 770x14 + 0x0
= 10780
= 10.78 m
C/C distance between bolts along the width Row1 = 4550 mm
C/C distance between bolts along the width Row2 = 0 mm
C/C distance between far end bolts along the width Wa = 4550 mm
= 4.55 m
C/L of shaft from top of grout = 2000 mm
= 2.00 m
6.5 Check for minimum requirement of size of foundation pedestal:
Bolt Projection Calculation
As per vendor data distance of first bolt from centre line of = 1350 mm Ref. Vendor Data DEK046054
discharge
Bolt projection, P =t + b + (n+0.5)*d+(50mm for bolts>36mm dia)

t = thickness of grout = 50 mm
b thickness of base frame bottom flange = = 28 mm Ref. Vendor Data DEK046054
n = number of nuts = 2
d = dia of bolt = 30 mm
Bolt projection, P = 153 mm
Hence provide = 155 mm
Check For Foundation pedestal Length
Min bolt edge distance, Dmin = 120 mm Annex-B-API_RP_686
Min base plate edge distance, BPmin = 130 mm
Foundation length to be maximum of
1 ( 2 x Dmin ) + La = 2x0.12+10.78 = 11.02 m
2 ( 2 x BPmin ) + lx = 2x0.13+11.08 = 11.34 m
Hence the minimum required length of the = 11.34 m
foundation
Adopted length of foundation pedestal , Lx = 13.08 m
Check For Foundation pedestal width
Min bolt edge distance, Dmin = 120 mm
Min base plate edge distance, BPmin = 150 mm assumed
Foundation length to be maximum of
1 ( 2 x Dmin ) + Wa = 2x0.12+4.55 = 4.79 m
2 ( 2 x BPmin ) + lz = 2x0.15+4.65 = 4.95 m
Hence the minimum required length of the = 4.95 m
foundation
Adopted length of foundation pedestal , Lz = 5.81 m
Check For Foundation Thickness
As per SAES-Q-007-Cl. 6.1.3, the minimum thickness of the concrete foundation shall not be less than the following:
Min. foundation thickness for machine = 0.60 + L/60 ( Where L is greater of length
= 0.6+ 13.08/60 or width in meters )
= 0.82 m
Adopted foundation thickness, Ly = 1.87 m Foundation thickness okay
Considering length of the foundation = 13.08 m
Height between base of foundation and shaft = 4.012 m
Considering width of the foundation = 5.810 m < 6.018 m Increase Width
Considering depth of the foundation = 1.87 m CL 6.3 API RP 686,pg 4-5
Provide 50 mm grout under the base plate

Page 7 of 59
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area

PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020


CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
Check for foundation weight
The foundation weight should be greater than 3 times of machine weight as per Sec.5.1 - SAES-Q-007
and CL3.3 43A7.
Machine or Pump total weight, P = 956.48 kN
Pedestal weight, Pd = 13.08 x 5.81 x 1.12 x 25
= 2127.85 kN
Foundation weight, Pf = 13.1 x 5.8 x 0.75 x 25
= 1424.90 kN
= Pf + Pd
= 1425 + 2127.854
Additional weight for base frame filling = 530.8
= 4084 kN > 3xP ( = 2,869.43 kN )
6.6 Calculation of static load on the foundation:

The weight of machine P = 956.48 kN Ref. Vendor Data DEK046054

Total weight = 956.48 kN


Impact loading
Vertical Load 50% of machine weight = 0.5*956.475
= 478.24 kN
Lateral Load 25% of machine weight = 0.25*956.475 Ref. Cl. 3.2.1.6 -ACI-351.3R
= 239.12 kN
Longitudinal Load 25% of machine weight = 0.25*956.475
= 239.12 kN
Moment due to longitudinal load along xx dir = 239.12x(0.75+0.75+0.37+0.05+2)
= 937.35 kNm
Moment due to lateral load along zz dir = 239.12x(0.75+0.75+0.37+0.05+2)
= 937.35 kNm
Moment along xx dir = 937.35 kNm
Moment along zz dir = 937.35 kNm
6.7 Geometric parameters of foundation base:
( + Y Upwards ) X

Z
L= 13080

(0,0,0)

B= 5810

Pump Base Frame

Pump Pedestal / Foundation

Page 8 of 59
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area

PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020


CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020

Area of foundation A = 13.08 x 5.81


= 75.99 m2

Section modulus of foundation about C.G z-z zxx = 13.08 x 5.81 x 5.81
6
= 73.59 m3
Section modulus of foundation about C.G x-x zzz = 5.81 x 13.08 x 13.1
= 6
Wind case: = 165.67 m3

Longitudinal load in X direction due to wind load Fx wind = 0.00 kN


No Data from Vendor
Lateral load in Z direction due to wind load Fz wind = 0.00 kN

Moment about Z direction due to wind load Mz wind = 0.00 kNm


at bottom of foundation
Moment about X direction due to wind load Mx wind = 0.00 kNm
at bottom of foundation

Seismic case:

Longitudinal load in X direction due to wind load Fx wind = 0.00 kN


No Data from Vendor
Lateral load in Z direction due to wind load Fz wind = 0.00 kN

Moment about Z direction due to wind load Mz wind = 0.00 kNm


at bottom of foundation
Moment about X direction due to wind load Mx wind = 0.00 kNm
at bottom of foundation

Page 9 of 59
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area

PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020


CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020

x-coord y-coord Z-coord


S.No (mm) (mm) UP (mm) Remarks
C.G of the
1 2540 1937 2943 Pump
C.G of the
2 0 0 0 pump rotor Origin considered from pump base frame edge
C.G of the
3 7617 2788 2851 motor
C.G of the
4 0 0 0 motor rotor
C.G of the
5 0 0 0 base frame

Combined c.g
6 4772 842 2915 of machine

x-coord y-coord Z-coord


S.No Remarks
(mm) (mm) (mm)
1 3540 3857 3523 C.G of the pump
C.G of the pump
2 1000 1920 580 rotor Origin considered from Block foundation edge
3 8617 4708 3431 C.G of the motor
C.G of the motor
4 1000 1920 580 rotor
C.G of the base
5 1000 1920 580 frame
6 5772 2762 3495 Combined c.g

Sketch showing C.G from the reference point Base Frame

1000 11080 1000

580

x 580

z
C/L OF Base frame
4650 2943 2915 2851

580 2540

C.G of Motor & rotor


4772 C.G of combined system
C.G of pump &rotor
7617

Page 10 of 59
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area

PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020


CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020

2788 1937
842

1120

Y 750

7.0 GEOMETRIC PROPERTIES OF PUMP FOUNDATION:

7.1 Calculation of centre of gravity and mass moment of inertia:

Dimensions of the Coordinates of the C.G. of Static moment of mass


Weight Mass
elements (m) element(m) (kN sec2)
Element of the
system mi (kN
LYi Lxi LZi Wi (kN) sec2/m) Yi Xi Zi mi Yi mi Xi mi Zi
(w/g)
Pump Rotor 0.00 0.00 1.92 1.00 0.58 0.00 0.00 0.00
Motor Rotor 0.00 0.00 1.92 1.00 0.58 0.00 0.00 0.00
Base frame 0.4 11.08 4.65 235.44 24.00 1.92 1.00 0.58 46.08 24.00 13.92
Pump 269.78 27.50 3.86 3.54 3.52 106.07 97.35 96.88
Motor 451.26 46.00 4.71 8.62 3.43 216.57 396.38 157.83
Grout 0.05 11.18 4.75 54.71 5.58 1.90 1.00 0.58 10.57 5.58 3.23
Block 0.75 13.08 5.81 1424.90 145.25 0.38 6.54 2.91 54.47 950 421.95
Pedestal 1.12 13.08 5.81 2127.85 216.91 1.31 6.54 2.91 284.15 1418.6 630.11

Total 4563.94 465.23 717.90 2891.8 1323.93

7.2 Calculation of overall C.G and eccentricity:


The coordinates of the centre of gravity of the machines and foundation are
Yc UP = 717.9 / 465.23 = 1.54 m
Xc = 2891.81 / 465.23 = 6.22 m
Zc = 1323.93 / 465.23 = 2.85 m
Eccentricity of common C.G. with respect to the centroid of Block foundation:
Eccentricity in X - Direction = 6.22-6.54 = 0.32 = 2.45 %
13.08 13.08
Eccentricity in Z - Direction = 2.85-2.905 = 0.05 = 0.95 %
5.81 5.81

Permissible limit of Eccentricity = 5 % Sec.5.8.5 -PIP STC01015


Check for Eccentricity Along the length within 5 % = Safe
Check for Eccentricity Along the width within 5 % = Safe
Additional moment due to difference in C.g of = 0.3200 x (956.48+4083.511+478.2375+54.708)
Machine and foundation block along x-x Direction. = 1783.34 kNm
Additional moment due to difference in C.g of = 0.0550 x (956.48+4083.511+478.2375+54.708)
Machine and foundation block along z-z Direction. = 306.51 kNm
Total moment about zz dir = 937.35 + 1783.34
= 2720.69 kNm
Total moment about xx dir = 937.35 + 306.51

Page 11 of 59
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area

PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020


CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
= 1243.86 kNm

7.3 Check for Bearing capacity due to static load:

Wind case:

Pressure due to [P / A] = 5572.94 = 5608.94


75.99 75.99
2
= 73.81 kN/m
Pressure due to eccentricity & impact [ Mxstatic / Z ] = 1243.86
moment 73.59
2
= 16.90 kN/m
Pressure due to eccentricity & impact [ Mzstatic / Z ] = 2720.7
moment 165.7
2
= 16.42 kN/m

Base pressure

[P / A] + [ Mxstatic / Z ] + [Mxwind / Z] Pmax = 73.8 + 16.90 + 0.00


= 90.71 kN/m2 No Tension in foundation
[P / A] - [ Mxstatic / Z ] - [Mxwind / Z] Pmin = 73.8 - 16.90 - 0.00
= 56.90 kN/m2 No Tension in foundation
[P / A] + [ Mxstatic / Z ] + [Mzwind / Z] Pmax = 73.8 + 16.90 + 0.00
= 90.71 kN/m2 No Tension in foundation
[P / A] - [ Mxstatic / Z ] - [Mzwind / Z] Pmin = 73.8 - 16.90 - 0.00
= 56.90 kN/m2 No Tension in foundation

[P / A] + [ Mzstatic / Z ] + [Mxwind/Z] Pmax = 73.8 + 16.42 + 0.00


90.23 kN/m2 No Tension in foundation
[P / A] - [ Mzstatic / Z ] + [Mxwind/Z] Pmin = 73.8 - 16.42 + 0.00
57.38 kN/m2 No Tension in foundation
[P / A] + [ Mzstatic / Z ] + [Mzwind/Z] Pmax = 73.8 + 16.42 + 0.00
90.23 kN/m2 No Tension in foundation
[P / A] - [ Mzstatic / Z ] + [Mzwind/Z] Pmin = 73.8 - 16.42 + 0.00
57.38 kN/m2 No Tension in foundation

2
Allowable Bearing Pressure = 97.5 kN/m
2 2
Maximum base Pressure = 90.71 kN/m < 98 kN/m safe

Seismic case:

Pressure due to [P / A] = 4083.51 = 4633.231


75.99 75.99
2
= 60.97 kN/m
Pressure due to eccentricity & impact [ Mxstatic / Z ] = 1243.86
moment 73.59
2
= 16.90 kN/m
Pressure due to eccentricity & impact [ Mzstatic / Z ] = 2720.7
moment 165.7
2
= 16.42 kN/m

Page 12 of 59
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area

PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020


CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020

Base pressure

[P / A] + [ Mxstatic / Z ] + [MxEQ / Z] Pmax = 61.0 + 16.90 + 0.00


= 77.87 kN/m2 No Tension in foundation
[P / A] - [ Mxstatic / Z ] - [MxEQ / Z] Pmin = 61.0 - 16.90 - 0.00
= 44.06 kN/m2 No Tension in foundation
[P / A] + [ Mxstatic / Z ] + [MzEQ / Z] Pmax = 61.0 + 16.90 + 0.00
= 77.87 kN/m2 No Tension in foundation
[P / A] - [ Mxstatic / Z ] - [MzEQ / Z] Pmin = 61.0 - 16.90 - 0.00
= 44.06 kN/m2 No Tension in foundation

[P / A] + [ Mzstatic / Z ] + [MxEQ/Z] Pmax = 61.0 + 16.42 + 0.00


77.39 kN/m2 No Tension in foundation
[P / A] - [ Mzstatic / Z ] + [MxEQ/Z] Pmin = 61.0 - 16.42 + 0.00
44.55 kN/m2 No Tension in foundation
[P / A] + [ Mzstatic / Z ] + [MzEQ/Z] Pmax = 61.0 + 16.42 + 0.00
77.39 kN/m2 No Tension in foundation
[P / A] - [ Mzstatic / Z ] + [MzEQ/Z] Pmin = 61.0 - 16.42 + 0.00
44.55 kN/m2 No Tension in foundation

2
Allowable Bearing Pressure = 97.5 kN/m
2 2
Maximum base Pressure = 77.87 kN/m < 98 kN/m safe

Centriod of machine and foundation


Xc = 6.22 m
Zc = 2.85 m
Yc = 1.54 m
(0,0) X

Z
2.85

Zf = 2.91
Zc =

Xc = 6.22
Xf = 6.54

Page 13 of 59
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area

PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020


CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020

C/L of driver

Y
Yc = 1.540

Note
1) Where Xf, Zf denotes C.G of foundation base
2) Where Xc,Yc,Zc denotes combined C.G of block foundation and machine

8.0 DYNAMIC ANALYSIS OF FOUNDATION:

Calculation of Equivalent Spring constants of foundation


Ref : Design of structures and foundations for vibrating machines By Suresh C Arya ,Michael W O' neil
and George Pincus.
Embedment coefficients for Spring Constants (Table 4.2, page 59)

Length of foundation L = 13.08 m


Width of foundation B = 5.81 m
a) Equivalent Radius
Vertical mode of Vibration ro = BL
π

= 13.08*5.81
3.14
= 4.918 m
Horizontal mode of Vibration ro = BL
π

= 13.08*5.81
3.14
= 4.918 m
Rocking mode of Vibration ro = 3
4
LB

= 4 13.08*5.81^3
3x3.14
= 4.062 m

Pitching mode of Vibration ro = 4


BL3

= 4 5.81*13.08^3
3x3.14
= 6.094 m
Torsional mode of Vibration ro = 4
(
BL L2 + B 2 6π )
0.25
13.08*5.81*(13.08^2+5.81^2)
= 6* π

= 5.361 m

Page 14 of 59
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area

PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020


CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020

Dynamic shear modulus of soil G = 80000 kN/m2


Dynamic poisson ratio of soil ν = 0.35
Effective depth of foundation below ground level h = 1.2 m

Embedment factor for spring constant


Vertical mode of Vibration ηy = 1 + 0.6(1 − υ )(h ro )
= 1+0.6*(1-0.35)*(1.2/4.918)
= 1.095
Horizontal mode of Vibration ηx = 1 + 0 . 55 (2 − υ )(h r o )
= 1+0.55*(2-0.35)*(1.2/4.918)
= 1.221
ηΨ = 1+1.2(1−υ)(h r0 ) +0.2(2−υ)(h r0 )
3
Rocking mode of Vibration

= 1+1.2*(1-0.35)*(1.2/4.062)+0.2*(2-0.35)*(1.2/4.062)^3
= 1.239
ηΦ = 1+1.2(1−υ)(h r0 ) +0.2(2−υ)(h r0 )
3
Pitching mode of Vibration
= 1+1.2*(1-0.35)*(1.2/6.094)+0.2*(2-0.35)*(1.2/6.094)^3
= 1.156
Torsional mode of vibration = None available

Geometric Factors

B/L = 2.25
βy = 2.23 Ref: Fig 1, Appendix A
βx = 0.97
βΨ = 0.67
L/B = 0.44
βz = 0.99
βΦ = 0.43

Note: From Appendix-A - Figure-1- Graph shown, vertical spring constants are captured from "βz" curve, Horizontal spring
constants are captured from "βx" curve & rocking, pitching spring constants are captured from " βΨ" ," βΦ " curves.
Equivalent Spring Constant for rectangular footings (Table 4.1, page 58)

Vertical mode of Vibration ky = G β y √BL ηy


1-ν

= (80000/(1-0.35))*2.23*√(13.08*5.81)*1.095
= 2623995.1 kN/m
ky = 34528.61 kN/m3
Horizontal mode of Vibration X-direction kx = 2(1+ν) G β x√BL ηx

= 2*(1+0.35)*80000*0.97*√(13.08*5.81)*1.221
= 2232110.3 kN/m
kx = 29371.88 kN/m3
Horizontal mode of Vibration Z-direction kz = 2(1+ν) G β z√BL ηx

= 2*(1+0.35)*80000*0.99*√(13.08*5.81)*1.221
= 2281207.2 kN/m
kz = 30017.94 kN/m3

Page 15 of 59
.

SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020

8.1 Summary of Dynamic Analysis

Speed of the Driver = 1800 rpm Refer Doc. from FLOWSERVE_440-G-0563 A/B
30 cycles/sec

Forces are taken as per the Vendor drawing.

Weight considered in Staad for Dynamic analysis

Page 16 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
8.2 STAAD Input for Dynamic Analysis

STAAD SPACE
START JOB INFORMATION
JOB PART SHIPPER PUMP FOUNDATION
ENGINEER NAME BPK
ENGINEER DATE 29-JAN-202
END JOB INFORMATION
INPUT WIDTH 79
UNIT METER KN
JOINT COORDINATES
1 0.499994 0 -5.03846e-006; 2 1.26999 0 -5.03846e-006;
3 -6.97633e-006 0 -5.03846e-006; 4 12.05 0 -5.03846e-006;
5 12.55 0 -5.03846e-006; 6 2.03999 0 -5.03846e-006; 19 13.08 0 -5.03846e-006;
20 0.499994 0 0.249996; 21 1.26999 0 0.249996; 22 -6.97633e-006 0 0.249996;
23 12.05 0 0.249996; 24 12.55 0 0.249996; 25 2.03999 0 0.249996;
38 13.08 0 0.249996; 39 0.499994 0 0.629996; 40 1.26999 0 0.629996;
41 -6.97633e-006 0 0.629996; 42 12.05 0 0.629996; 43 12.55 0 0.629996;
44 2.03999 0 0.629996; 57 13.08 0 0.629996; 58 0.499994 0 1.25;
59 1.26999 0 1.25; 60 -6.97633e-006 0 1.25; 61 12.05 0 1.25; 62 12.55 0 1.25;
63 2.03999 0 1.25; 76 13.08 0 1.25; 77 0.499994 0 1.75; 78 1.26999 0 1.75;
79 -6.97633e-006 0 1.75; 80 12.05 0 1.75; 81 12.55 0 1.75; 82 2.03999 0 1.75;
95 13.08 0 1.75; 96 0.499994 0 2.25; 97 1.26999 0 2.25;
98 -6.97633e-006 0 2.25; 99 12.05 0 2.25; 100 12.55 0 2.25; 101 2.03999 0 2.25;
114 13.08 0 2.25; 115 0.499994 0 2.75; 116 1.26999 0 2.75;
117 -6.97633e-006 0 2.75; 118 12.05 0 2.75; 119 12.55 0 2.75;
120 2.03999 0 2.75; 133 13.08 0 2.75; 134 0.499994 0 3.25; 135 1.26999 0 3.25;
136 -6.97633e-006 0 3.25; 137 12.05 0 3.25; 138 12.55 0 3.25;
139 2.03999 0 3.25; 152 13.08 0 3.25; 153 0.499994 0 3.75; 154 1.26999 0 3.75;
155 -6.97633e-006 0 3.75; 156 12.05 0 3.75; 157 12.55 0 3.75;
158 2.03999 0 3.75; 171 13.08 0 3.75; 172 12.05 0 4.25; 173 12.55 0 4.25;
174 0.499994 0 4.25; 175 1.26999 0 4.25; 176 -6.97633e-006 0 4.25;
177 2.03999 0 4.25; 190 13.08 0 4.25; 191 12.05 0 4.75; 192 12.55 0 4.75;
193 0.499994 0 4.75; 194 1.26999 0 4.75; 195 -6.97633e-006 0 4.75;
196 2.03999 0 4.75; 209 13.08 0 4.75; 210 -6.97633e-006 0 5.18;
211 1.26999 0 5.18; 212 0.499994 0 5.18; 213 12.55 0 5.18; 214 12.05 0 5.18;
215 2.03999 0 5.18; 228 13.08 0 5.18; 229 0.499994 0 5.81; 230 1.26999 0 5.81;
231 -6.97633e-006 0 5.81; 232 12.05 0 5.81; 233 12.55 0 5.81;
234 2.03999 0 5.81; 247 13.08 0 5.81; 248 0.499994 0.37 -5.03846e-006;
249 1.26999 0.37 -5.03846e-006; 250 -6.97633e-006 0.37 -5.03846e-006;
251 12.05 0.37 -5.03846e-006; 252 12.55 0.37 -5.03846e-006;
253 2.03999 0.37 -5.03846e-006; 266 13.08 0.37 -5.03846e-006;
267 0.499994 0.37 0.249996; 268 1.26999 0.37 0.249996;
269 -6.97633e-006 0.37 0.249996; 270 12.05 0.37 0.249996;

Page 17 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
271 12.55 0.37 0.249996; 272 2.03999 0.37 0.249996; 285 13.08 0.37 0.249996;
286 0.499994 0.37 0.629996; 287 1.26999 0.37 0.629996;
288 -6.97633e-006 0.37 0.629996; 289 12.05 0.37 0.629996;
290 12.55 0.37 0.629996; 291 2.03999 0.37 0.629996; 304 13.08 0.37 0.629996;
305 0.499994 0.37 1.25; 306 1.26999 0.37 1.25; 307 -6.97633e-006 0.37 1.25;
308 12.05 0.37 1.25; 309 12.55 0.37 1.25; 310 2.03999 0.37 1.25;
323 13.08 0.37 1.25; 324 0.499994 0.37 1.75; 325 1.26999 0.37 1.75;
326 -6.97633e-006 0.37 1.75; 327 12.05 0.37 1.75; 328 12.55 0.37 1.75;
329 2.03999 0.37 1.75; 342 13.08 0.37 1.75; 343 0.499994 0.37 2.25;
344 1.26999 0.37 2.25; 345 -6.97633e-006 0.37 2.25; 346 12.05 0.37 2.25;
347 12.55 0.37 2.25; 348 2.03999 0.37 2.25; 361 13.08 0.37 2.25;
362 0.499994 0.37 2.75; 363 1.26999 0.37 2.75; 364 -6.97633e-006 0.37 2.75;
365 12.05 0.37 2.75; 366 12.55 0.37 2.75; 367 2.03999 0.37 2.75;
380 13.08 0.37 2.75; 381 0.499994 0.37 3.25; 382 1.26999 0.37 3.25;
383 -6.97633e-006 0.37 3.25; 384 12.05 0.37 3.25; 385 12.55 0.37 3.25;
386 2.03999 0.37 3.25; 399 13.08 0.37 3.25; 400 0.499994 0.37 3.75;
401 1.26999 0.37 3.75; 402 -6.97633e-006 0.37 3.75; 403 12.05 0.37 3.75;
404 12.55 0.37 3.75; 405 2.03999 0.37 3.75; 418 13.08 0.37 3.75;
419 12.05 0.37 4.25; 420 12.55 0.37 4.25; 421 0.499994 0.37 4.25;
422 1.26999 0.37 4.25; 423 -6.97633e-006 0.37 4.25; 424 2.03999 0.37 4.25;
437 13.08 0.37 4.25; 438 12.05 0.37 4.75; 439 12.55 0.37 4.75;
440 0.499994 0.37 4.75; 441 1.26999 0.37 4.75; 442 -6.97633e-006 0.37 4.75;
443 2.03999 0.37 4.75; 456 13.08 0.37 4.75; 457 -6.97633e-006 0.37 5.18;
458 1.26999 0.37 5.18; 459 0.499994 0.37 5.18; 460 12.55 0.37 5.18;
461 12.05 0.37 5.18; 462 2.03999 0.37 5.18; 475 13.08 0.37 5.18;
476 0.499994 0.37 5.81; 477 1.26999 0.37 5.81; 478 -6.97633e-006 0.37 5.81;
479 12.05 0.37 5.81; 480 12.55 0.37 5.81; 481 2.03999 0.37 5.81;
494 13.08 0.37 5.81; 495 0.499994 0.87 -5.03846e-006;
496 1.26999 0.87 -5.03846e-006; 497 -6.97633e-006 0.87 -5.03846e-006;
498 12.05 0.87 -5.03846e-006; 499 12.55 0.87 -5.03846e-006;
500 2.03999 0.87 -5.03846e-006; 513 13.08 0.87 -5.03846e-006;
514 0.499994 0.87 0.249996; 515 1.26999 0.87 0.249996;
516 -6.97633e-006 0.87 0.249996; 517 12.05 0.87 0.249996;
518 12.55 0.87 0.249996; 519 2.03999 0.87 0.249996; 532 13.08 0.87 0.249996;
533 0.499994 0.87 0.629996; 534 1.26999 0.87 0.629996;
535 -6.97633e-006 0.87 0.629996; 536 12.05 0.87 0.629996;
537 12.55 0.87 0.629996; 538 2.03999 0.87 0.629996; 551 13.08 0.87 0.629996;
552 0.499994 0.87 1.25; 553 1.26999 0.87 1.25; 554 -6.97633e-006 0.87 1.25;
555 12.05 0.87 1.25; 556 12.55 0.87 1.25; 557 2.03999 0.87 1.25;
570 13.08 0.87 1.25; 571 0.499994 0.87 1.75; 572 1.26999 0.87 1.75;
573 -6.97633e-006 0.87 1.75; 574 12.05 0.87 1.75; 575 12.55 0.87 1.75;
576 2.03999 0.87 1.75; 589 13.08 0.87 1.75; 590 0.499994 0.87 2.25;
591 1.26999 0.87 2.25; 592 -6.97633e-006 0.87 2.25; 593 12.05 0.87 2.25;
594 12.55 0.87 2.25; 595 2.03999 0.87 2.25; 608 13.08 0.87 2.25;
609 0.499994 0.87 2.75; 610 1.26999 0.87 2.75; 611 -6.97633e-006 0.87 2.75;
612 12.05 0.87 2.75; 613 12.55 0.87 2.75; 614 2.03999 0.87 2.75;
627 13.08 0.87 2.75; 628 0.499994 0.87 3.25; 629 1.26999 0.87 3.25;

Page 18 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
630 -6.97633e-006 0.87 3.25; 631 12.05 0.87 3.25; 632 12.55 0.87 3.25;
633 2.03999 0.87 3.25; 646 13.08 0.87 3.25; 647 0.499994 0.87 3.75;
648 1.26999 0.87 3.75; 649 -6.97633e-006 0.87 3.75; 650 12.05 0.87 3.75;
651 12.55 0.87 3.75; 652 2.03999 0.87 3.75; 665 13.08 0.87 3.75;
666 12.05 0.87 4.25; 667 12.55 0.87 4.25; 668 0.499994 0.87 4.25;
669 1.26999 0.87 4.25; 670 -6.97633e-006 0.87 4.25; 671 2.03999 0.87 4.25;
684 13.08 0.87 4.25; 685 12.05 0.87 4.75; 686 12.55 0.87 4.75;
687 0.499994 0.87 4.75; 688 1.26999 0.87 4.75; 689 -6.97633e-006 0.87 4.75;
690 2.03999 0.87 4.75; 703 13.08 0.87 4.75; 704 -6.97633e-006 0.87 5.18;
705 1.26999 0.87 5.18; 706 0.499994 0.87 5.18; 707 12.55 0.87 5.18;
708 12.05 0.87 5.18; 709 2.03999 0.87 5.18; 722 13.08 0.87 5.18;
723 0.499994 0.87 5.81; 724 1.26999 0.87 5.81; 725 -6.97633e-006 0.87 5.81;
726 12.05 0.87 5.81; 727 12.55 0.87 5.81; 728 2.03999 0.87 5.81;
741 13.08 0.87 5.81; 742 0.499994 1.37001 -5.03846e-006;
743 1.26999 1.37001 -5.03846e-006; 744 -6.97633e-006 1.37001 -5.03846e-006;
745 12.05 1.37001 -5.03846e-006; 746 12.55 1.37001 -5.03846e-006;
747 2.03999 1.37001 -5.03846e-006; 760 13.08 1.37001 -5.03846e-006;
761 0.499994 1.37001 0.249996; 762 1.26999 1.37001 0.249996;
763 -6.97633e-006 1.37001 0.249996; 764 12.05 1.37001 0.249996;
765 12.55 1.37001 0.249996; 766 2.03999 1.37001 0.249996;
779 13.08 1.37001 0.249996; 780 0.5 1.37001 0.629996;
781 1.26999 1.37001 0.629996; 782 0 1.37001 0.629996;
783 12.05 1.37001 0.629996; 784 12.55 1.37001 0.629996;
785 2.03999 1.37001 0.629996; 798 13.08 1.37001 0.629996;
799 0.499994 1.37001 1.25; 800 1.26999 1.37001 1.25;
801 -6.97633e-006 1.37001 1.25; 802 12.05 1.37001 1.25; 803 12.55 1.37001 1.25;
804 2.03999 1.37001 1.25; 817 13.08 1.37001 1.25; 818 0.499994 1.37001 1.75;
819 1.26999 1.37001 1.75; 820 -6.97633e-006 1.37001 1.75;
821 12.05 1.37001 1.75; 822 12.55 1.37001 1.75; 823 2.03999 1.37001 1.75;
836 13.08 1.37001 1.75; 837 0.499994 1.37001 2.25; 838 1.26999 1.37001 2.25;
839 -6.97633e-006 1.37001 2.25; 840 12.05 1.37001 2.25; 841 12.55 1.37001 2.25;
842 2.03999 1.37001 2.25; 855 13.08 1.37001 2.25; 856 0.499994 1.37001 2.75;
857 1.26999 1.37001 2.75; 858 -6.97633e-006 1.37001 2.75;
859 12.05 1.37001 2.75; 860 12.55 1.37001 2.75; 861 2.03999 1.37001 2.75;
874 13.08 1.37001 2.75; 875 0.499994 1.37001 3.25; 876 1.26999 1.37001 3.25;
877 -6.97633e-006 1.37001 3.25; 878 12.05 1.37001 3.25; 879 12.55 1.37001 3.25;
880 2.03999 1.37001 3.25; 893 13.08 1.37001 3.25; 894 0.499994 1.37001 3.75;
895 1.26999 1.37001 3.75; 896 -6.97633e-006 1.37001 3.75;
897 12.05 1.37001 3.75; 898 12.55 1.37001 3.75; 899 2.03999 1.37001 3.75;
912 13.08 1.37001 3.75; 913 0.499994 1.37001 4.25; 914 1.26999 1.37001 4.25;
915 12.05 1.37001 4.25; 916 12.55 1.37001 4.25; 917 -6.97633e-006 1.37001 4.25;
918 2.03999 1.37001 4.25; 931 13.08 1.37001 4.25; 932 0.499994 1.37001 4.75;
933 1.26999 1.37001 4.75; 934 12.05 1.37001 4.75; 935 12.55 1.37001 4.75;
936 -6.97633e-006 1.37001 4.75; 937 2.03999 1.37001 4.75;
950 13.08 1.37001 4.75; 951 1.26999 1.37001 5.18; 952 0.499994 1.37001 5.18;
953 -6.97633e-006 1.37001 5.18; 954 12.55 1.37001 5.18; 955 12.05 1.37001 5.18;
956 2.03999 1.37001 5.18; 969 13.08 1.37001 5.18; 970 0.499994 1.37001 5.81;

Page 19 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
971 1.26999 1.37001 5.81; 972 -6.97633e-006 1.37001 5.81;
973 12.05 1.37001 5.81; 974 12.55 1.37001 5.81; 975 2.03999 1.37001 5.81;
988 13.08 1.37001 5.81; 989 0.499994 1.87001 -5.03846e-006;
990 1.26999 1.87001 -5.03846e-006; 991 -6.97633e-006 1.87001 -5.03846e-006;
992 12.05 1.87001 -5.03846e-006; 993 12.55 1.87001 -5.03846e-006;
994 2.03999 1.87001 -5.03846e-006; 1007 13.08 1.87001 -5.03846e-006;
1008 0.499994 1.87001 0.249996; 1009 1.26999 1.87001 0.249996;
1010 -6.97633e-006 1.87001 0.249996; 1011 12.05 1.87001 0.249996;
1012 12.55 1.87001 0.249996; 1013 2.03999 1.87001 0.249996;
1026 13.08 1.87001 0.249996; 1027 0.499994 1.87001 0.629996;
1028 1.26999 1.87001 0.629996; 1035 -6.97633e-006 1.87001 0.629996;
1036 12.05 1.87001 0.629996; 1037 12.55 1.87001 0.629996;
1038 2.03999 1.87001 0.629996; 1039 2.80999 1.87001 0.629996;
1040 3.57999 1.87001 0.629996; 1041 4.34999 1.87001 0.629996;
1042 5.12 1.87001 0.629996; 1043 5.88999 1.87001 0.629996;
1044 6.66 1.87001 0.629996; 1045 7.42999 1.87001 0.629996;
1046 8.2 1.87001 0.629996; 1047 8.96999 1.87001 0.629996;
1048 9.73999 1.87001 0.629996; 1049 10.51 1.87001 0.629996;
1050 11.28 1.87001 0.629996; 1052 0.499994 1.87001 1.25;
1053 1.26999 1.87001 1.25; 1054 -6.97633e-006 1.87001 1.25;
1055 12.05 1.87001 1.25; 1056 12.55 1.87001 1.25; 1057 2.03999 1.87001 1.25;
1071 0.499994 1.87001 1.75; 1072 1.26999 1.87001 1.75;
1073 -6.97633e-006 1.87001 1.75; 1074 12.05 1.87001 1.75;
1075 12.55 1.87001 1.75; 1076 2.03999 1.87001 1.75; 1090 0.499994 1.87001 2.25;
1091 1.26999 1.87001 2.25; 1092 -6.97633e-006 1.87001 2.25;
1093 12.05 1.87001 2.25; 1094 12.55 1.87001 2.25; 1095 2.03999 1.87001 2.25;
1108 13.08 1.87001 2.25; 1109 0.499994 1.87001 2.75; 1110 1.26999 1.87001 2.75;
1111 -6.97633e-006 1.87001 2.75; 1112 12.05 1.87001 2.75;
1113 12.55 1.87001 2.75; 1114 2.03999 1.87001 2.75; 1127 13.08 1.87001 2.75;
1128 0.499994 1.87001 3.25; 1129 1.26999 1.87001 3.25;
1130 -6.97633e-006 1.87001 3.25; 1131 12.05 1.87001 3.25;
1132 12.55 1.87001 3.25; 1133 2.03999 1.87001 3.25; 1146 13.08 1.87001 3.25;
1147 0.499994 1.87001 3.75; 1148 1.26999 1.87001 3.75;
1149 2.03999 1.87001 3.75; 1155 -6.97633e-006 1.87001 3.75;
1156 12.05 1.87001 3.75; 1157 12.55 1.87001 3.75; 1171 13.08 1.87001 3.75;
1172 0.499994 1.87001 4.25; 1173 1.26999 1.87001 4.25; 1174 12.05 1.87001 4.25;
1175 12.55 1.87001 4.25; 1176 -6.97633e-006 1.87001 4.25;
1177 2.03999 1.87001 4.25; 1190 13.08 1.87001 4.25; 1191 0.499994 1.87001 4.75;
1192 1.26999 1.87001 4.75; 1193 12.05 1.87001 4.75; 1194 12.55 1.87001 4.75;
1195 -6.97633e-006 1.87001 4.75; 1196 2.03999 1.87001 4.75;
1209 13.08 1.87001 4.75; 1210 1.26999 1.87001 5.18; 1211 0.499994 1.87001 5.18;
1212 -6.97633e-006 1.87001 5.18; 1213 12.55 1.87001 5.18;
1214 12.05 1.87001 5.18; 1215 2.03999 1.87001 5.18; 1216 2.80999 1.87001 5.18;
1217 3.57999 1.87001 5.18; 1218 4.34999 1.87001 5.18; 1219 5.12 1.87001 5.18;
1220 5.88999 1.87001 5.18; 1221 6.66 1.87001 5.18; 1222 7.42999 1.87001 5.18;
1223 8.2 1.87001 5.18; 1224 8.96999 1.87001 5.18; 1225 9.73999 1.87001 5.18;
1226 10.51 1.87001 5.18; 1227 11.28 1.87001 5.18; 1228 13.08 1.87001 5.18;
1229 0.499994 1.87001 5.81; 1230 1.26999 1.87001 5.81;
1231 -6.97633e-006 1.87001 5.81; 1232 12.05 1.87001 5.81;
1233 12.55 1.87001 5.81; 1234 2.03999 1.87001 5.81; 1247 13.08 1.87001 5.81;
1248 6.17 3.5 2.83; 1249 2.80999 0 -5.03846e-006; 1250 2.80999 0 0.249996;

Page 20 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
1251 2.80999 0 0.629996; 1252 2.80999 0 1.25; 1253 2.80999 0 1.75;
1254 2.80999 0 2.25; 1255 2.80999 0 2.75; 1256 2.80999 0 3.25;
1257 2.80999 0 3.75; 1258 2.80999 0 4.25; 1259 2.80999 0 4.75;
1260 2.80999 0 5.18; 1261 2.80999 0 5.81; 1262 2.80999 0.37 -5.03846e-006;
1263 2.80999 0.37 0.249996; 1264 2.80999 0.37 0.629996; 1265 2.80999 0.37 1.25;
1266 2.80999 0.37 1.75; 1267 2.80999 0.37 2.25; 1268 2.80999 0.37 2.75;
1269 2.80999 0.37 3.25; 1270 2.80999 0.37 3.75; 1271 2.80999 0.37 4.25;
1272 2.80999 0.37 4.75; 1273 2.80999 0.37 5.18; 1274 2.80999 0.37 5.81;
1275 2.80999 0.87 -5.03846e-006; 1276 2.80999 0.87 0.249996;
1277 2.80999 0.87 0.629996; 1278 2.80999 0.87 1.25; 1279 2.80999 0.87 1.75;
1280 2.80999 0.87 2.25; 1281 2.80999 0.87 2.75; 1282 2.80999 0.87 3.25;
1283 2.80999 0.87 3.75; 1284 2.80999 0.87 4.25; 1285 2.80999 0.87 4.75;
1286 2.80999 0.87 5.18; 1287 2.80999 0.87 5.81;
1288 2.80999 1.37001 -5.03846e-006; 1289 2.80999 1.37001 0.249996;
1290 2.80999 1.37001 0.629996; 1291 2.80999 1.37001 1.25;
1292 2.80999 1.37001 1.75; 1293 2.80999 1.37001 2.25;
1294 2.80999 1.37001 2.75; 1295 2.80999 1.37001 3.25;
1296 2.80999 1.37001 3.75; 1297 2.80999 1.37001 4.25;
1298 2.80999 1.37001 4.75; 1299 2.80999 1.37001 5.18;
1300 2.80999 1.37001 5.81; 1301 2.80999 1.87001 -5.03846e-006;
1302 2.80999 1.87001 0.249996; 1303 2.80999 1.87001 1.25;
1304 2.80999 1.87001 1.75; 1305 2.80999 1.87001 2.25;

1306 2.80999 1.87001 2.75; 1307 2.80999 1.87001 3.25;


1308 2.80999 1.87001 3.75; 1309 2.80999 1.87001 4.25;
1310 2.80999 1.87001 4.75; 1311 2.80999 1.87001 5.81;
1312 3.57999 0 -5.03846e-006; 1313 3.57999 0 0.249996; 1314 3.57999 0 0.629996;
1315 3.57999 0 1.25; 1316 3.57999 0 1.75; 1317 3.57999 0 2.25;
1318 3.57999 0 2.75; 1319 3.57999 0 3.25; 1320 3.57999 0 3.75;
1321 3.57999 0 4.25; 1322 3.57999 0 4.75; 1323 3.57999 0 5.18;

1324 3.57999 0 5.81; 1325 3.57999 0.37 -5.03846e-006;


1326 3.57999 0.37 0.249996; 1327 3.57999 0.37 0.629996; 1328 3.57999 0.37 1.25;
1329 3.57999 0.37 1.75; 1330 3.57999 0.37 2.25; 1331 3.57999 0.37 2.75;
1332 3.57999 0.37 3.25; 1333 3.57999 0.37 3.75; 1334 3.57999 0.37 4.25;
1335 3.57999 0.37 4.75; 1336 3.57999 0.37 5.18; 1337 3.57999 0.37 5.81;
1338 3.57999 0.87 -5.03846e-006; 1339 3.57999 0.87 0.249996;
1340 3.57999 0.87 0.629996; 1341 3.57999 0.87 1.25; 1342 3.57999 0.87 1.75;
1343 3.57999 0.87 2.25; 1344 3.57999 0.87 2.75; 1345 3.57999 0.87 3.25;
1346 3.57999 0.87 3.75; 1347 3.57999 0.87 4.25; 1348 3.57999 0.87 4.75;
1349 3.57999 0.87 5.18; 1350 3.57999 0.87 5.81;
1351 3.57999 1.37001 -5.03846e-006; 1352 3.57999 1.37001 0.249996;
1353 3.57999 1.37001 0.629996; 1354 3.57999 1.37001 1.25;
1355 3.57999 1.37001 1.75; 1356 3.57999 1.37001 2.25;
1357 3.57999 1.37001 2.75; 1358 3.57999 1.37001 3.25;
1359 3.57999 1.37001 3.75; 1360 3.57999 1.37001 4.25;
1361 3.57999 1.37001 4.75; 1362 3.57999 1.37001 5.18;

1363 3.57999 1.37001 5.81; 1364 3.57999 1.87001 -5.03846e-006;


1365 3.57999 1.87001 0.249996; 1366 3.57999 1.87001 1.25;
1367 3.57999 1.87001 1.75; 1368 3.57999 1.87001 2.25;
1369 3.57999 1.87001 2.75; 1370 3.57999 1.87001 3.25;
1371 3.57999 1.87001 3.75; 1372 3.57999 1.87001 4.25;
1373 3.57999 1.87001 4.75; 1374 3.57999 1.87001 5.81;

Page 21 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
1375 4.34999 0 -5.03846e-006; 1376 4.34999 0 0.249996; 1377 4.34999 0 0.629996;
1378 4.34999 0 1.25; 1379 4.34999 0 1.75; 1380 4.34999 0 2.25;
1381 4.34999 0 2.75; 1382 4.34999 0 3.25; 1383 4.34999 0 3.75;
1384 4.34999 0 4.25; 1385 4.34999 0 4.75; 1386 4.34999 0 5.18;
1387 4.34999 0 5.81; 1388 4.34999 0.37 -5.03846e-006;
1389 4.34999 0.37 0.249996; 1390 4.34999 0.37 0.629996; 1391 4.34999 0.37 1.25;
1392 4.34999 0.37 1.75; 1393 4.34999 0.37 2.25; 1394 4.34999 0.37 2.75;
1395 4.34999 0.37 3.25; 1396 4.34999 0.37 3.75; 1397 4.34999 0.37 4.25;
1398 4.34999 0.37 4.75; 1399 4.34999 0.37 5.18; 1400 4.34999 0.37 5.81;
1401 4.34999 0.87 -5.03846e-006; 1402 4.34999 0.87 0.249996;
1403 4.34999 0.87 0.629996; 1404 4.34999 0.87 1.25; 1405 4.34999 0.87 1.75;
1406 4.34999 0.87 2.25; 1407 4.34999 0.87 2.75; 1408 4.34999 0.87 3.25;
1409 4.34999 0.87 3.75; 1410 4.34999 0.87 4.25; 1411 4.34999 0.87 4.75;
1412 4.34999 0.87 5.18; 1413 4.34999 0.87 5.81;
1414 4.34999 1.37001 -5.03846e-006; 1415 4.34999 1.37001 0.249996;
1416 4.34999 1.37001 0.629996; 1417 4.34999 1.37001 1.25;
1418 4.34999 1.37001 1.75; 1419 4.34999 1.37001 2.25;
1420 4.34999 1.37001 2.75; 1421 4.34999 1.37001 3.25;
1422 4.34999 1.37001 3.75; 1423 4.34999 1.37001 4.25;
1424 4.34999 1.37001 4.75; 1425 4.34999 1.37001 5.18;
1426 4.34999 1.37001 5.81; 1427 4.34999 1.87001 -5.03846e-006;
1428 4.34999 1.87001 0.249996; 1429 4.34999 1.87001 1.25;
1430 4.34999 1.87001 1.75; 1431 4.34999 1.87001 2.25;
1432 4.34999 1.87001 2.75; 1433 4.34999 1.87001 3.25;
1434 4.34999 1.87001 3.75; 1435 4.34999 1.87001 4.25;
1436 4.34999 1.87001 4.75; 1437 4.34999 1.87001 5.81;
1438 5.12 0 -5.03846e-006; 1439 5.12 0 0.249996; 1440 5.12 0 0.629996;
1441 5.12 0 1.25; 1442 5.12 0 1.75; 1443 5.12 0 2.25; 1444 5.12 0 2.75;
1445 5.12 0 3.25; 1446 5.12 0 3.75; 1447 5.12 0 4.25; 1448 5.12 0 4.75;
1449 5.12 0 5.18; 1450 5.12 0 5.81; 1451 5.12 0.37 -5.03846e-006;
1452 5.12 0.37 0.249996; 1453 5.12 0.37 0.629996; 1454 5.12 0.37 1.25;
1455 5.12 0.37 1.75; 1456 5.12 0.37 2.25; 1457 5.12 0.37 2.75;
1458 5.12 0.37 3.25; 1459 5.12 0.37 3.75; 1460 5.12 0.37 4.25;
1461 5.12 0.37 4.75; 1462 5.12 0.37 5.18; 1463 5.12 0.37 5.81;
1464 5.12 0.87 -5.03846e-006; 1465 5.12 0.87 0.249996; 1466 5.12 0.87 0.629996;
1467 5.12 0.87 1.25; 1468 5.12 0.87 1.75; 1469 5.12 0.87 2.25;
1470 5.12 0.87 2.75; 1471 5.12 0.87 3.25; 1472 5.12 0.87 3.75;
1473 5.12 0.87 4.25; 1474 5.12 0.87 4.75; 1475 5.12 0.87 5.18;
1476 5.12 0.87 5.81; 1477 5.12 1.37001 -5.03846e-006;
1478 5.12 1.37001 0.249996; 1479 5.12 1.37001 0.629996; 1480 5.12 1.37001 1.25;
1481 5.12 1.37001 1.75; 1482 5.12 1.37001 2.25; 1483 5.12 1.37001 2.75;
1484 5.12 1.37001 3.25; 1485 5.12 1.37001 3.75; 1486 5.12 1.37001 4.25;
1487 5.12 1.37001 4.75; 1488 5.12 1.37001 5.18; 1489 5.12 1.37001 5.81;
1490 5.12 1.87001 -5.03846e-006; 1491 5.12 1.87001 0.249996;
1492 5.12 1.87001 1.25; 1493 5.12 1.87001 1.75; 1494 5.12 1.87001 2.25;
1495 5.12 1.87001 2.75; 1496 5.12 1.87001 3.25; 1497 5.12 1.87001 3.75;
1498 5.12 1.87001 4.25; 1499 5.12 1.87001 4.75; 1500 5.12 1.87001 5.81;
1501 5.88999 0 -5.03846e-006; 1502 5.88999 0 0.249996; 1503 5.88999 0 0.629996;
1504 5.88999 0 1.25; 1505 5.88999 0 1.75; 1506 5.88999 0 2.25;
1507 5.88999 0 2.75; 1508 5.88999 0 3.25; 1509 5.88999 0 3.75;
1510 5.88999 0 4.25; 1511 5.88999 0 4.75; 1512 5.88999 0 5.18;

Page 22 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
1513 5.88999 0 5.81; 1514 5.88999 0.37 -5.03846e-006;
1515 5.88999 0.37 0.249996; 1516 5.88999 0.37 0.629996; 1517 5.88999 0.37 1.25;
1518 5.88999 0.37 1.75; 1519 5.88999 0.37 2.25; 1520 5.88999 0.37 2.75;
1521 5.88999 0.37 3.25; 1522 5.88999 0.37 3.75; 1523 5.88999 0.37 4.25;
1524 5.88999 0.37 4.75; 1525 5.88999 0.37 5.18; 1526 5.88999 0.37 5.81;
1527 5.88999 0.87 -5.03846e-006; 1528 5.88999 0.87 0.249996;
1529 5.88999 0.87 0.629996; 1530 5.88999 0.87 1.25; 1531 5.88999 0.87 1.75;
1532 5.88999 0.87 2.25; 1533 5.88999 0.87 2.75; 1534 5.88999 0.87 3.25;
1535 5.88999 0.87 3.75; 1536 5.88999 0.87 4.25; 1537 5.88999 0.87 4.75;
1538 5.88999 0.87 5.18; 1539 5.88999 0.87 5.81;
1540 5.88999 1.37001 -5.03846e-006; 1541 5.88999 1.37001 0.249996;
1542 5.88999 1.37001 0.629996; 1543 5.88999 1.37001 1.25;
1544 5.88999 1.37001 1.75; 1545 5.88999 1.37001 2.25;
1546 5.88999 1.37001 2.75; 1547 5.88999 1.37001 3.25;
1548 5.88999 1.37001 3.75; 1549 5.88999 1.37001 4.25;
1550 5.88999 1.37001 4.75; 1551 5.88999 1.37001 5.18;
1552 5.88999 1.37001 5.81; 1553 5.88999 1.87001 -5.03846e-006;
1554 5.88999 1.87001 0.249996; 1555 5.88999 1.87001 1.25;
1556 5.88999 1.87001 1.75; 1557 5.88999 1.87001 2.25;
1558 5.88999 1.87001 2.75; 1559 5.88999 1.87001 3.25;
1560 5.88999 1.87001 3.75; 1561 5.88999 1.87001 4.25;
1562 5.88999 1.87001 4.75; 1563 5.88999 1.87001 5.81;
1564 6.66 0 -5.03846e-006; 1565 6.66 0 0.249996; 1566 6.66 0 0.629996;
1567 6.66 0 1.25; 1568 6.66 0 1.75; 1569 6.66 0 2.25; 1570 6.66 0 2.75;
1571 6.66 0 3.25; 1572 6.66 0 3.75; 1573 6.66 0 4.25; 1574 6.66 0 4.75;
1575 6.66 0 5.18; 1576 6.66 0 5.81; 1577 6.66 0.37 -5.03846e-006;
1578 6.66 0.37 0.249996; 1579 6.66 0.37 0.629996; 1580 6.66 0.37 1.25;
1581 6.66 0.37 1.75; 1582 6.66 0.37 2.25; 1583 6.66 0.37 2.75;
1584 6.66 0.37 3.25; 1585 6.66 0.37 3.75; 1586 6.66 0.37 4.25;
1587 6.66 0.37 4.75; 1588 6.66 0.37 5.18; 1589 6.66 0.37 5.81;
1590 6.66 0.87 -5.03846e-006; 1591 6.66 0.87 0.249996; 1592 6.66 0.87 0.629996;
1593 6.66 0.87 1.25; 1594 6.66 0.87 1.75; 1595 6.66 0.87 2.25;
1596 6.66 0.87 2.75; 1597 6.66 0.87 3.25; 1598 6.66 0.87 3.75;
1599 6.66 0.87 4.25; 1600 6.66 0.87 4.75; 1601 6.66 0.87 5.18;
1602 6.66 0.87 5.81; 1603 6.66 1.37001 -5.03846e-006;
1604 6.66 1.37001 0.249996; 1605 6.66 1.37001 0.629996; 1606 6.66 1.37001 1.25;
1607 6.66 1.37001 1.75; 1608 6.66 1.37001 2.25; 1609 6.66 1.37001 2.75;
1610 6.66 1.37001 3.25; 1611 6.66 1.37001 3.75; 1612 6.66 1.37001 4.25;
1613 6.66 1.37001 4.75; 1614 6.66 1.37001 5.18; 1615 6.66 1.37001 5.81;
1616 6.66 1.87001 -5.03846e-006; 1617 6.66 1.87001 0.249996;
1618 6.66 1.87001 1.25; 1619 6.66 1.87001 1.75; 1620 6.66 1.87001 2.25;
1621 6.66 1.87001 2.75; 1622 6.66 1.87001 3.25; 1623 6.66 1.87001 3.75;
1624 6.66 1.87001 4.25; 1625 6.66 1.87001 4.75; 1626 6.66 1.87001 5.81;
1627 7.42999 0 -5.03846e-006; 1628 7.42999 0 0.249996; 1629 7.42999 0 0.629996;
1630 7.42999 0 1.25; 1631 7.42999 0 1.75; 1632 7.42999 0 2.25;
1633 7.42999 0 2.75; 1634 7.42999 0 3.25; 1635 7.42999 0 3.75;
1636 7.42999 0 4.25; 1637 7.42999 0 4.75; 1638 7.42999 0 5.18;
1639 7.42999 0 5.81; 1640 7.42999 0.37 -5.03846e-006;
1641 7.42999 0.37 0.249996; 1642 7.42999 0.37 0.629996; 1643 7.42999 0.37 1.25;
1644 7.42999 0.37 1.75; 1645 7.42999 0.37 2.25; 1646 7.42999 0.37 2.75;
1647 7.42999 0.37 3.25; 1648 7.42999 0.37 3.75; 1649 7.42999 0.37 4.25;
1650 7.42999 0.37 4.75; 1651 7.42999 0.37 5.18; 1652 7.42999 0.37 5.81;
1653 7.42999 0.87 -5.03846e-006; 1654 7.42999 0.87 0.249996;

Page 23 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
1655 7.42999 0.87 0.629996; 1656 7.42999 0.87 1.25; 1657 7.42999 0.87 1.75;
1658 7.42999 0.87 2.25; 1659 7.42999 0.87 2.75; 1660 7.42999 0.87 3.25;
1661 7.42999 0.87 3.75; 1662 7.42999 0.87 4.25; 1663 7.42999 0.87 4.75;
1664 7.42999 0.87 5.18; 1665 7.42999 0.87 5.81;
1666 7.42999 1.37001 -5.03846e-006; 1667 7.42999 1.37001 0.249996;
1668 7.42999 1.37001 0.629996; 1669 7.42999 1.37001 1.25;
1670 7.42999 1.37001 1.75; 1671 7.42999 1.37001 2.25;
1672 7.42999 1.37001 2.75; 1673 7.42999 1.37001 3.25;
1674 7.42999 1.37001 3.75; 1675 7.42999 1.37001 4.25;
1676 7.42999 1.37001 4.75; 1677 7.42999 1.37001 5.18;
1678 7.42999 1.37001 5.81; 1679 7.42999 1.87001 -5.03846e-006;
1680 7.42999 1.87001 0.249996; 1681 7.42999 1.87001 1.25;
1682 7.42999 1.87001 1.75; 1683 7.42999 1.87001 2.25;
1684 7.42999 1.87001 2.75; 1685 7.42999 1.87001 3.25;
1686 7.42999 1.87001 3.75; 1687 7.42999 1.87001 4.25;
1688 7.42999 1.87001 4.75; 1689 7.42999 1.87001 5.81; 1690 8.2 0 -5.03846e-006;
1691 8.2 0 0.249996; 1692 8.2 0 0.629996; 1693 8.2 0 1.25; 1694 8.2 0 1.75;
1695 8.2 0 2.25; 1696 8.2 0 2.75; 1697 8.2 0 3.25; 1698 8.2 0 3.75;
1699 8.2 0 4.25; 1700 8.2 0 4.75; 1701 8.2 0 5.18; 1702 8.2 0 5.81;
1703 8.2 0.37 -5.03846e-006; 1704 8.2 0.37 0.249996; 1705 8.2 0.37 0.629996;
1706 8.2 0.37 1.25; 1707 8.2 0.37 1.75; 1708 8.2 0.37 2.25; 1709 8.2 0.37 2.75;
1710 8.2 0.37 3.25; 1711 8.2 0.37 3.75; 1712 8.2 0.37 4.25; 1713 8.2 0.37 4.75;
1714 8.2 0.37 5.18; 1715 8.2 0.37 5.81; 1716 8.2 0.87 -5.03846e-006;
1717 8.2 0.87 0.249996; 1718 8.2 0.87 0.629996; 1719 8.2 0.87 1.25;
1720 8.2 0.87 1.75; 1721 8.2 0.87 2.25; 1722 8.2 0.87 2.75; 1723 8.2 0.87 3.25;
1724 8.2 0.87 3.75; 1725 8.2 0.87 4.25; 1726 8.2 0.87 4.75; 1727 8.2 0.87 5.18;
1728 8.2 0.87 5.81; 1729 8.2 1.37001 -5.03846e-006; 1730 8.2 1.37001 0.249996;
1731 8.2 1.37001 0.629996; 1732 8.2 1.37001 1.25; 1733 8.2 1.37001 1.75;
1734 8.2 1.37001 2.25; 1735 8.2 1.37001 2.75; 1736 8.2 1.37001 3.25;
1737 8.2 1.37001 3.75; 1738 8.2 1.37001 4.25; 1739 8.2 1.37001 4.75;
1740 8.2 1.37001 5.18; 1741 8.2 1.37001 5.81; 1742 8.2 1.87001 -5.03846e-006;
1743 8.2 1.87001 0.249996; 1744 8.2 1.87001 1.25; 1745 8.2 1.87001 1.75;
1746 8.2 1.87001 2.25; 1747 8.2 1.87001 2.75; 1748 8.2 1.87001 3.25;
1749 8.2 1.87001 3.75; 1750 8.2 1.87001 4.25; 1751 8.2 1.87001 4.75;
1752 8.2 1.87001 5.81; 1753 8.97 0 -5.03846e-006; 1754 8.97 0 0.249996;
1755 8.97 0 0.629996; 1756 8.97 0 1.25; 1757 8.97 0 1.75; 1758 8.97 0 2.25;
1759 8.97 0 2.75; 1760 8.97 0 3.25; 1761 8.97 0 3.75; 1762 8.97 0 4.25;
1763 8.97 0 4.75; 1764 8.97 0 5.18; 1765 8.97 0 5.81;
1766 8.97 0.37 -5.03846e-006; 1767 8.97 0.37 0.249996; 1768 8.97 0.37 0.629996;
1769 8.97 0.37 1.25; 1770 8.97 0.37 1.75; 1771 8.97 0.37 2.25;
1772 8.97 0.37 2.75; 1773 8.97 0.37 3.25; 1774 8.97 0.37 3.75;
1775 8.97 0.37 4.25; 1776 8.97 0.37 4.75; 1777 8.97 0.37 5.18;
1778 8.97 0.37 5.81; 1779 8.97 0.87 -5.03846e-006; 1780 8.97 0.87 0.249996;
1781 8.97 0.87 0.629996; 1782 8.97 0.87 1.25; 1783 8.97 0.87 1.75;
1784 8.97 0.87 2.25; 1785 8.97 0.87 2.75; 1786 8.97 0.87 3.25;
1787 8.97 0.87 3.75; 1788 8.97 0.87 4.25; 1789 8.97 0.87 4.75;
1790 8.97 0.87 5.18; 1791 8.97 0.87 5.81; 1792 8.97 1.37001 -5.03846e-006;
1793 8.97 1.37001 0.249996; 1794 8.97 1.37001 0.629996; 1795 8.97 1.37001 1.25;
1796 8.97 1.37001 1.75; 1797 8.97 1.37001 2.25; 1798 8.97 1.37001 2.75;
1799 8.97 1.37001 3.25; 1800 8.97 1.37001 3.75; 1801 8.97 1.37001 4.25;
1802 8.97 1.37001 4.75; 1803 8.97 1.37001 5.18; 1804 8.97 1.37001 5.81;
1805 8.97 1.87001 -5.03846e-006; 1806 8.97 1.87001 0.249996;
1807 8.97 1.87001 1.25; 1808 8.97 1.87001 1.75; 1809 8.97 1.87001 2.25;
1810 8.97 1.87001 2.75; 1811 8.97 1.87001 3.25; 1812 8.97 1.87001 3.75;
1813 8.97 1.87001 4.25; 1814 8.97 1.87001 4.75; 1815 8.97 1.87001 5.81;
1816 9.74 0 -5.03846e-006; 1817 9.74 0 0.249996; 1818 9.74 0 0.629996;

Page 24 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
1819 9.74 0 1.25; 1820 9.74 0 1.75; 1821 9.74 0 2.25; 1822 9.74 0 2.75;
1823 9.74 0 3.25; 1824 9.74 0 3.75; 1825 9.74 0 4.25; 1826 9.74 0 4.75;
1827 9.74 0 5.18; 1828 9.74 0 5.81; 1829 9.74 0.37 -5.03846e-006;
1830 9.74 0.37 0.249996; 1831 9.74 0.37 0.629996; 1832 9.74 0.37 1.25;
1833 9.74 0.37 1.75; 1834 9.74 0.37 2.25; 1835 9.74 0.37 2.75;
1836 9.74 0.37 3.25; 1837 9.74 0.37 3.75; 1838 9.74 0.37 4.25;
1839 9.74 0.37 4.75; 1840 9.74 0.37 5.18; 1841 9.74 0.37 5.81;
1842 9.74 0.87 -5.03846e-006; 1843 9.74 0.87 0.249996; 1844 9.74 0.87 0.629996;
1845 9.74 0.87 1.25; 1846 9.74 0.87 1.75; 1847 9.74 0.87 2.25;
1848 9.74 0.87 2.75; 1849 9.74 0.87 3.25; 1850 9.74 0.87 3.75;
1851 9.74 0.87 4.25; 1852 9.74 0.87 4.75; 1853 9.74 0.87 5.18;
1854 9.74 0.87 5.81; 1855 9.74 1.37001 -5.03846e-006;
1856 9.74 1.37001 0.249996; 1857 9.74 1.37001 0.629996; 1858 9.74 1.37001 1.25;
1859 9.74 1.37001 1.75; 1860 9.74 1.37001 2.25; 1861 9.74 1.37001 2.75;
1862 9.74 1.37001 3.25; 1863 9.74 1.37001 3.75; 1864 9.74 1.37001 4.25;
1865 9.74 1.37001 4.75; 1866 9.74 1.37001 5.18; 1867 9.74 1.37001 5.81;
1868 9.74 1.87001 -5.03846e-006; 1869 9.74 1.87001 0.249996;
1870 9.74 1.87001 1.25; 1871 9.74 1.87001 1.75; 1872 9.74 1.87001 2.25;
1873 9.74 1.87001 2.75; 1874 9.74 1.87001 3.25; 1875 9.74 1.87001 3.75;

Page 25 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
1876 9.74 1.87001 4.25; 1877 9.74 1.87001 4.75; 1878 9.74 1.87001 5.81;
1879 10.51 0 -5.03846e-006; 1880 10.51 0 0.249996; 1881 10.51 0 0.629996;
1882 10.51 0 1.25; 1883 10.51 0 1.75; 1884 10.51 0 2.25; 1885 10.51 0 2.75;
1886 10.51 0 3.25; 1887 10.51 0 3.75; 1888 10.51 0 4.25; 1889 10.51 0 4.75;
1890 10.51 0 5.18; 1891 10.51 0 5.81; 1892 10.51 0.37 -5.03846e-006;
1893 10.51 0.37 0.249996; 1894 10.51 0.37 0.629996; 1895 10.51 0.37 1.25;
1896 10.51 0.37 1.75; 1897 10.51 0.37 2.25; 1898 10.51 0.37 2.75;
1899 10.51 0.37 3.25; 1900 10.51 0.37 3.75; 1901 10.51 0.37 4.25;
1902 10.51 0.37 4.75; 1903 10.51 0.37 5.18; 1904 10.51 0.37 5.81;
1905 10.51 0.87 -5.03846e-006; 1906 10.51 0.87 0.249996;
1907 10.51 0.87 0.629996; 1908 10.51 0.87 1.25; 1909 10.51 0.87 1.75;
1910 10.51 0.87 2.25; 1911 10.51 0.87 2.75; 1912 10.51 0.87 3.25;
1913 10.51 0.87 3.75; 1914 10.51 0.87 4.25; 1915 10.51 0.87 4.75;
1916 10.51 0.87 5.18; 1917 10.51 0.87 5.81; 1918 10.51 1.37001 -5.03846e-006;
1919 10.51 1.37001 0.249996; 1920 10.51 1.37001 0.629996;
1921 10.51 1.37001 1.25; 1922 10.51 1.37001 1.75; 1923 10.51 1.37001 2.25;
1924 10.51 1.37001 2.75; 1925 10.51 1.37001 3.25; 1926 10.51 1.37001 3.75;
1927 10.51 1.37001 4.25; 1928 10.51 1.37001 4.75; 1929 10.51 1.37001 5.18;
1930 10.51 1.37001 5.81; 1931 10.51 1.87001 -5.03846e-006;
1932 10.51 1.87001 0.249996; 1933 10.51 1.87001 1.25; 1934 10.51 1.87001 1.75;
1935 10.51 1.87001 2.25; 1936 10.51 1.87001 2.75; 1937 10.51 1.87001 3.25;
1938 10.51 1.87001 3.75; 1939 10.51 1.87001 4.25; 1940 10.51 1.87001 4.75;
1941 10.51 1.87001 5.81; 1942 11.28 0 -5.03846e-006; 1943 11.28 0 0.249996;
1944 11.28 0 0.629996; 1945 11.28 0 1.25; 1946 11.28 0 1.75; 1947 11.28 0 2.25;
1948 11.28 0 2.75; 1949 11.28 0 3.25; 1950 11.28 0 3.75; 1951 11.28 0 4.25;
1952 11.28 0 4.75; 1953 11.28 0 5.18; 1954 11.28 0 5.81;
1955 11.28 0.37 -5.03846e-006; 1956 11.28 0.37 0.249996;
1957 11.28 0.37 0.629996; 1958 11.28 0.37 1.25; 1959 11.28 0.37 1.75;
1960 11.28 0.37 2.25; 1961 11.28 0.37 2.75; 1962 11.28 0.37 3.25;
1963 11.28 0.37 3.75; 1964 11.28 0.37 4.25; 1965 11.28 0.37 4.75;
1966 11.28 0.37 5.18; 1967 11.28 0.37 5.81; 1968 11.28 0.87 -5.03846e-006;
1969 11.28 0.87 0.249996; 1970 11.28 0.87 0.629996; 1971 11.28 0.87 1.25;
1972 11.28 0.87 1.75; 1973 11.28 0.87 2.25; 1974 11.28 0.87 2.75;
1975 11.28 0.87 3.25; 1976 11.28 0.87 3.75; 1977 11.28 0.87 4.25;
1978 11.28 0.87 4.75; 1979 11.28 0.87 5.18; 1980 11.28 0.87 5.81;
1981 11.28 1.37001 -5.03846e-006; 1982 11.28 1.37001 0.249996;
1983 11.28 1.37001 0.629996; 1984 11.28 1.37001 1.25; 1985 11.28 1.37001 1.75;
1986 11.28 1.37001 2.25; 1987 11.28 1.37001 2.75; 1988 11.28 1.37001 3.25;
1989 11.28 1.37001 3.75; 1990 11.28 1.37001 4.25; 1991 11.28 1.37001 4.75;
1992 11.28 1.37001 5.18; 1993 11.28 1.37001 5.81;
1994 11.28 1.87001 -5.03846e-006; 1995 11.28 1.87001 0.249996;
1996 11.28 1.87001 1.25; 1997 11.28 1.87001 1.75; 1998 11.28 1.87001 2.25;
1999 11.28 1.87001 2.75; 2000 11.28 1.87001 3.25; 2001 11.28 1.87001 3.75;
2002 11.28 1.87001 4.25; 2003 11.28 1.87001 4.75; 2004 11.28 1.87001 5.81;
2005 13.08 1.87001 0.629996; 2006 13.08 1.87001 1.25; 2007 13.08 1.87001 1.75;
MEMBER INCIDENCES
3113 1211 1248; 3114 1210 1248; 3115 1215 1248; 3116 1216 1248; 3117 1217 1248;
3118 1218 1248; 3119 1219 1248; 3120 1220 1248; 3121 1221 1248; 3122 1222 1248;
3123 1223 1248; 3124 1224 1248; 3125 1225 1248; 3126 1226 1248; 3127 1227 1248;
3128 1027 1248; 3129 1028 1248; 3130 1038 1248; 3131 1039 1248; 3132 1040 1248;
3133 1041 1248; 3134 1042 1248; 3135 1043 1248; 3136 1044 1248; 3137 1045 1248;
3138 1046 1248; 3139 1047 1248; 3140 1048 1248; 3141 1049 1248; 3142 1050 1248;
ELEMENT INCIDENCES SOLID
23 780 781 1028 1027 761 762 1009 1008; 24 799 800 1053 1052 780 781 1028 1027;
25 818 819 1072 1071 799 800 1053 1052; 26 837 838 1091 1090 818 819 1072 1071;
27 856 857 1110 1109 837 838 1091 1090; 28 875 876 1129 1128 856 857 1110 1109;

Page 26 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
29 894 895 1148 1147 875 876 1129 1128; 30 970 971 1230 1229 952 951 1210 1211;
32 761 762 1009 1008 742 743 990 989; 223 533 534 781 780 514 515 762 761;
224 552 553 800 799 533 534 781 780; 225 571 572 819 818 552 553 800 799;
226 590 591 838 837 571 572 819 818; 227 609 610 857 856 590 591 838 837;
228 628 629 876 875 609 610 857 856; 229 647 648 895 894 628 629 876 875;
230 723 724 971 970 706 705 951 952; 232 514 515 762 761 495 496 743 742;
423 286 287 534 533 267 268 515 514; 424 305 306 553 552 286 287 534 533;
425 324 325 572 571 305 306 553 552; 426 343 344 591 590 324 325 572 571;
427 362 363 610 609 343 344 591 590; 428 381 382 629 628 362 363 610 609;
429 400 401 648 647 381 382 629 628; 430 476 477 724 723 459 458 705 706;
432 267 268 515 514 248 249 496 495; 623 39 40 287 286 20 21 268 267;
624 58 59 306 305 39 40 287 286; 625 77 78 325 324 58 59 306 305;
626 96 97 344 343 77 78 325 324; 627 115 116 363 362 96 97 344 343;
628 134 135 382 381 115 116 363 362; 629 153 154 401 400 134 135 382 381;
630 229 230 477 476 212 211 458 459; 632 20 21 268 267 1 2 249 248;
1603 782 780 1027 1035 763 761 1008 1010;
1604 801 799 1052 1054 782 780 1027 1035;
1605 820 818 1071 1073 801 799 1052 1054;
1606 839 837 1090 1092 820 818 1071 1073;
1607 858 856 1109 1111 839 837 1090 1092;
1608 877 875 1128 1130 858 856 1109 1111;
1609 896 894 1147 1155 877 875 1128 1130;
1610 972 970 1229 1231 953 952 1211 1212;
1612 763 761 1008 1010 744 742 989 991; 1613 535 533 780 782 516 514 761 763;
1614 554 552 799 801 535 533 780 782; 1615 573 571 818 820 554 552 799 801;
1616 592 590 837 839 573 571 818 820; 1617 611 609 856 858 592 590 837 839;
1618 630 628 875 877 611 609 856 858; 1619 649 647 894 896 630 628 875 877;
1620 725 723 970 972 704 706 952 953; 1622 516 514 761 763 497 495 742 744;
1623 288 286 533 535 269 267 514 516; 1624 307 305 552 554 288 286 533 535;
1625 326 324 571 573 307 305 552 554; 1626 345 343 590 592 326 324 571 573;
1627 364 362 609 611 345 343 590 592; 1628 383 381 628 630 364 362 609 611;
1629 402 400 647 649 383 381 628 630; 1630 478 476 723 725 457 459 706 704;
1632 269 267 514 516 250 248 495 497; 1633 41 39 286 288 22 20 267 269;
1634 60 58 305 307 41 39 286 288; 1635 79 77 324 326 60 58 305 307;
1636 98 96 343 345 79 77 324 326; 1637 117 115 362 364 98 96 343 345;
1638 136 134 381 383 117 115 362 364; 1639 155 153 400 402 136 134 381 383;
1640 231 229 476 478 210 212 459 457; 1642 22 20 267 269 3 1 248 250;
2023 783 784 1037 1036 764 765 1012 1011;
2024 802 803 1056 1055 783 784 1037 1036;
2025 821 822 1075 1074 802 803 1056 1055;
2026 840 841 1094 1093 821 822 1075 1074;
2027 859 860 1113 1112 840 841 1094 1093;
2028 878 879 1132 1131 859 860 1113 1112;
2029 897 898 1157 1156 878 879 1132 1131;
2030 973 974 1233 1232 955 954 1213 1214;
2032 764 765 1012 1011 745 746 993 992; 2033 536 537 784 783 517 518 765 764;
2034 555 556 803 802 536 537 784 783; 2035 574 575 822 821 555 556 803 802;
2036 593 594 841 840 574 575 822 821; 2037 612 613 860 859 593 594 841 840;
2038 631 632 879 878 612 613 860 859; 2039 650 651 898 897 631 632 879 878;
2040 726 727 974 973 708 707 954 955; 2042 517 518 765 764 498 499 746 745;
2043 289 290 537 536 270 271 518 517; 2044 308 309 556 555 289 290 537 536;
2045 327 328 575 574 308 309 556 555; 2046 346 347 594 593 327 328 575 574;
2047 365 366 613 612 346 347 594 593; 2048 384 385 632 631 365 366 613 612;
2049 403 404 651 650 384 385 632 631; 2050 479 480 727 726 461 460 707 708;
2052 270 271 518 517 251 252 499 498; 2053 42 43 290 289 23 24 271 270;

Page 27 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
2054 61 62 309 308 42 43 290 289; 2055 80 81 328 327 61 62 309 308;
2056 99 100 347 346 80 81 328 327; 2057 118 119 366 365 99 100 347 346;
2058 137 138 385 384 118 119 366 365; 2059 156 157 404 403 137 138 385 384;
2060 232 233 480 479 214 213 460 461; 2062 23 24 271 270 4 5 252 251;
2063 913 914 1173 1172 894 895 1148 1147; 2081 668 669 914 913 647 648 895 894;
2099 421 422 669 668 400 401 648 647; 2117 174 175 422 421 153 154 401 400;
2135 917 913 1172 1176 896 894 1147 1155; 2136 670 668 913 917 649 647 894 896;
2137 423 421 668 670 402 400 647 649; 2138 176 174 421 423 155 153 400 402;
2163 915 916 1175 1174 897 898 1157 1156; 2164 666 667 916 915 650 651 898 897;
2165 419 420 667 666 403 404 651 650; 2166 172 173 420 419 156 157 404 403;
2167 932 933 1192 1191 913 914 1173 1172; 2185 687 688 933 932 668 669 914 913;
2203 440 441 688 687 421 422 669 668; 2221 193 194 441 440 174 175 422 421;
2239 936 932 1191 1195 917 913 1172 1176; 2240 689 687 932 936 670 668 913 917;
2241 442 440 687 689 423 421 668 670; 2242 195 193 440 442 176 174 421 423;
2267 934 935 1194 1193 915 916 1175 1174; 2268 685 686 935 934 666 667 916 915;
2269 438 439 686 685 419 420 667 666; 2270 191 192 439 438 172 173 420 419;
2271 952 951 1210 1211 932 933 1192 1191; 2289 706 705 951 952 687 688 933 932;
2307 459 458 705 706 440 441 688 687; 2325 212 211 458 459 193 194 441 440;
2343 953 952 1211 1212 936 932 1191 1195; 2344 704 706 952 953 689 687 932 936;
2345 457 459 706 704 442 440 687 689; 2346 210 212 459 457 195 193 440 442;
2371 955 954 1213 1214 934 935 1194 1193; 2372 708 707 954 955 685 686 935 934;
2373 461 460 707 708 438 439 686 685; 2374 214 213 460 461 191 192 439 438;
2375 781 785 1038 1028 762 766 1013 1009;
2376 800 804 1057 1053 781 785 1038 1028;
2377 819 823 1076 1072 800 804 1057 1053;
2378 838 842 1095 1091 819 823 1076 1072;
2379 857 861 1114 1110 838 842 1095 1091;
2380 876 880 1133 1129 857 861 1114 1110;
2381 895 899 1149 1148 876 880 1133 1129;
2382 971 975 1234 1230 951 956 1215 1210;
2383 762 766 1013 1009 743 747 994 990; 2384 534 538 785 781 515 519 766 762;
2385 553 557 804 800 534 538 785 781; 2386 572 576 823 819 553 557 804 800;
2387 591 595 842 838 572 576 823 819; 2388 610 614 861 857 591 595 842 838;
2389 629 633 880 876 610 614 861 857; 2390 648 652 899 895 629 633 880 876;
2391 724 728 975 971 705 709 956 951; 2392 515 519 766 762 496 500 747 743;
2393 287 291 538 534 268 272 519 515; 2394 306 310 557 553 287 291 538 534;
2395 325 329 576 572 306 310 557 553; 2396 344 348 595 591 325 329 576 572;
2397 363 367 614 610 344 348 595 591; 2398 382 386 633 629 363 367 614 610;
2399 401 405 652 648 382 386 633 629; 2400 477 481 728 724 458 462 709 705;
2401 268 272 519 515 249 253 500 496; 2402 40 44 291 287 21 25 272 268;
2403 59 63 310 306 40 44 291 287; 2404 78 82 329 325 59 63 310 306;
2405 97 101 348 344 78 82 329 325; 2406 116 120 367 363 97 101 348 344;
2407 135 139 386 382 116 120 367 363; 2408 154 158 405 401 135 139 386 382;
2409 230 234 481 477 211 215 462 458; 2410 21 25 272 268 2 6 253 249;
2411 914 918 1177 1173 895 899 1149 1148; 2412 669 671 918 914 648 652 899 895;
2413 422 424 671 669 401 405 652 648; 2414 175 177 424 422 154 158 405 401;
2415 933 937 1196 1192 914 918 1177 1173; 2416 688 690 937 933 669 671 918 914;
2417 441 443 690 688 422 424 671 669; 2418 194 196 443 441 175 177 424 422;
2419 951 956 1215 1210 933 937 1196 1192; 2420 705 709 956 951 688 690 937 933;
2421 458 462 709 705 441 443 690 688; 2422 211 215 462 458 194 196 443 441;
3051 860 874 1127 1113 841 855 1108 1094;
3052 879 893 1146 1132 860 874 1127 1113;
3053 898 912 1171 1157 879 893 1146 1132;
3054 974 988 1247 1233 954 969 1228 1213;
3055 765 779 1026 1012 746 760 1007 993; 3056 537 551 798 784 518 532 779 765;
3057 556 570 817 803 537 551 798 784; 3058 575 589 836 822 556 570 817 803;

Page 28 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
3059 594 608 855 841 575 589 836 822; 3060 613 627 874 860 594 608 855 841;
3061 632 646 893 879 613 627 874 860; 3062 651 665 912 898 632 646 893 879;
3063 727 741 988 974 707 722 969 954; 3064 518 532 779 765 499 513 760 746;
3065 290 304 551 537 271 285 532 518; 3066 309 323 570 556 290 304 551 537;
3067 328 342 589 575 309 323 570 556; 3068 347 361 608 594 328 342 589 575;
3069 366 380 627 613 347 361 608 594; 3070 385 399 646 632 366 380 627 613;
3071 404 418 665 651 385 399 646 632; 3072 480 494 741 727 460 475 722 707;
3073 271 285 532 518 252 266 513 499; 3074 43 57 304 290 24 38 285 271;
3075 62 76 323 309 43 57 304 290; 3076 81 95 342 328 62 76 323 309;
3077 100 114 361 347 81 95 342 328; 3078 119 133 380 366 100 114 361 347;
3079 138 152 399 385 119 133 380 366; 3080 157 171 418 404 138 152 399 385;
3081 233 247 494 480 213 228 475 460; 3082 24 38 285 271 5 19 266 252;
3083 916 931 1190 1175 898 912 1171 1157; 3084 667 684 931 916 651 665 912 898;
3085 420 437 684 667 404 418 665 651; 3086 173 190 437 420 157 171 418 404;
3087 935 950 1209 1194 916 931 1190 1175; 3088 686 703 950 935 667 684 931 916;
3089 439 456 703 686 420 437 684 667; 3090 192 209 456 439 173 190 437 420;
3091 954 969 1228 1213 935 950 1209 1194; 3092 707 722 969 954 686 703 950 935;
3093 460 475 722 707 439 456 703 686; 3094 213 228 475 460 192 209 456 439;
3143 785 1290 1039 1038 766 1289 1302 1013;
3144 804 1291 1303 1057 785 1290 1039 1038;
3145 823 1292 1304 1076 804 1291 1303 1057;
3146 842 1293 1305 1095 823 1292 1304 1076;
3147 861 1294 1306 1114 842 1293 1305 1095;
3148 880 1295 1307 1133 861 1294 1306 1114;
3149 899 1296 1308 1149 880 1295 1307 1133;
3150 975 1300 1311 1234 956 1299 1216 1215;
3151 766 1289 1302 1013 747 1288 1301 994;
3152 538 1277 1290 785 519 1276 1289 766;
3153 557 1278 1291 804 538 1277 1290 785;
3154 576 1279 1292 823 557 1278 1291 804;
3155 595 1280 1293 842 576 1279 1292 823;
3156 614 1281 1294 861 595 1280 1293 842;
3157 633 1282 1295 880 614 1281 1294 861;
3158 652 1283 1296 899 633 1282 1295 880;
3159 728 1287 1300 975 709 1286 1299 956;
3160 519 1276 1289 766 500 1275 1288 747;
3161 291 1264 1277 538 272 1263 1276 519;
3162 310 1265 1278 557 291 1264 1277 538;
3163 329 1266 1279 576 310 1265 1278 557;
3164 348 1267 1280 595 329 1266 1279 576;
3165 367 1268 1281 614 348 1267 1280 595;
3166 386 1269 1282 633 367 1268 1281 614;
3167 405 1270 1283 652 386 1269 1282 633;
3168 481 1274 1287 728 462 1273 1286 709;
3169 272 1263 1276 519 253 1262 1275 500;
3170 44 1251 1264 291 25 1250 1263 272; 3171 63 1252 1265 310 44 1251 1264 291;
3172 82 1253 1266 329 63 1252 1265 310;
3173 101 1254 1267 348 82 1253 1266 329;
3174 120 1255 1268 367 101 1254 1267 348;
3175 139 1256 1269 386 120 1255 1268 367;
3176 158 1257 1270 405 139 1256 1269 386;
3177 234 1261 1274 481 215 1260 1273 462;
3178 25 1250 1263 272 6 1249 1262 253;
3179 918 1297 1309 1177 899 1296 1308 1149;
3180 671 1284 1297 918 652 1283 1296 899;

Page 29 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
3181 424 1271 1284 671 405 1270 1283 652;
3182 177 1258 1271 424 158 1257 1270 405;
3183 937 1298 1310 1196 918 1297 1309 1177;
3184 690 1285 1298 937 671 1284 1297 918;
3185 443 1272 1285 690 424 1271 1284 671;
3186 196 1259 1272 443 177 1258 1271 424;
3187 956 1299 1216 1215 937 1298 1310 1196;
3188 709 1286 1299 956 690 1285 1298 937;
3189 462 1273 1286 709 443 1272 1285 690;
3190 215 1260 1273 462 196 1259 1272 443;
3191 1290 1353 1040 1039 1289 1352 1365 1302;
3192 1291 1354 1366 1303 1290 1353 1040 1039;
3193 1292 1355 1367 1304 1291 1354 1366 1303;
3194 1293 1356 1368 1305 1292 1355 1367 1304;
3195 1294 1357 1369 1306 1293 1356 1368 1305;
3196 1295 1358 1370 1307 1294 1357 1369 1306;
3197 1296 1359 1371 1308 1295 1358 1370 1307;
3198 1300 1363 1374 1311 1299 1362 1217 1216;
3199 1289 1352 1365 1302 1288 1351 1364 1301;
3200 1277 1340 1353 1290 1276 1339 1352 1289;
3201 1278 1341 1354 1291 1277 1340 1353 1290;
3202 1279 1342 1355 1292 1278 1341 1354 1291;
3203 1280 1343 1356 1293 1279 1342 1355 1292;
3204 1281 1344 1357 1294 1280 1343 1356 1293;
3205 1282 1345 1358 1295 1281 1344 1357 1294;
3206 1283 1346 1359 1296 1282 1345 1358 1295;
3207 1287 1350 1363 1300 1286 1349 1362 1299;
3208 1276 1339 1352 1289 1275 1338 1351 1288;
3209 1264 1327 1340 1277 1263 1326 1339 1276;
3210 1265 1328 1341 1278 1264 1327 1340 1277;
3211 1266 1329 1342 1279 1265 1328 1341 1278;
3212 1267 1330 1343 1280 1266 1329 1342 1279;
3213 1268 1331 1344 1281 1267 1330 1343 1280;
3214 1269 1332 1345 1282 1268 1331 1344 1281;
3215 1270 1333 1346 1283 1269 1332 1345 1282;
3216 1274 1337 1350 1287 1273 1336 1349 1286;
3217 1263 1326 1339 1276 1262 1325 1338 1275;
3218 1251 1314 1327 1264 1250 1313 1326 1263;
3219 1252 1315 1328 1265 1251 1314 1327 1264;
3220 1253 1316 1329 1266 1252 1315 1328 1265;
3221 1254 1317 1330 1267 1253 1316 1329 1266;
3222 1255 1318 1331 1268 1254 1317 1330 1267;
3223 1256 1319 1332 1269 1255 1318 1331 1268;
3224 1257 1320 1333 1270 1256 1319 1332 1269;
3225 1261 1324 1337 1274 1260 1323 1336 1273;
3226 1250 1313 1326 1263 1249 1312 1325 1262;
3227 1297 1360 1372 1309 1296 1359 1371 1308;
3228 1284 1347 1360 1297 1283 1346 1359 1296;
3229 1271 1334 1347 1284 1270 1333 1346 1283;
3230 1258 1321 1334 1271 1257 1320 1333 1270;
3231 1298 1361 1373 1310 1297 1360 1372 1309;
3232 1285 1348 1361 1298 1284 1347 1360 1297;
3233 1272 1335 1348 1285 1271 1334 1347 1284;
3234 1259 1322 1335 1272 1258 1321 1334 1271;

Page 30 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
3235 1299 1362 1217 1216 1298 1361 1373 1310;
3236 1286 1349 1362 1299 1285 1348 1361 1298;
3237 1273 1336 1349 1286 1272 1335 1348 1285;
3238 1260 1323 1336 1273 1259 1322 1335 1272;
3239 1353 1416 1041 1040 1352 1415 1428 1365;
3240 1354 1417 1429 1366 1353 1416 1041 1040;
3241 1355 1418 1430 1367 1354 1417 1429 1366;
3242 1356 1419 1431 1368 1355 1418 1430 1367;
3243 1357 1420 1432 1369 1356 1419 1431 1368;
3244 1358 1421 1433 1370 1357 1420 1432 1369;
3245 1359 1422 1434 1371 1358 1421 1433 1370;
3246 1363 1426 1437 1374 1362 1425 1218 1217;
3247 1352 1415 1428 1365 1351 1414 1427 1364;
3248 1340 1403 1416 1353 1339 1402 1415 1352;
3249 1341 1404 1417 1354 1340 1403 1416 1353;
3250 1342 1405 1418 1355 1341 1404 1417 1354;
3251 1343 1406 1419 1356 1342 1405 1418 1355;
3252 1344 1407 1420 1357 1343 1406 1419 1356;
3253 1345 1408 1421 1358 1344 1407 1420 1357;
3254 1346 1409 1422 1359 1345 1408 1421 1358;
3255 1350 1413 1426 1363 1349 1412 1425 1362;
3256 1339 1402 1415 1352 1338 1401 1414 1351;
3257 1327 1390 1403 1340 1326 1389 1402 1339;
3258 1328 1391 1404 1341 1327 1390 1403 1340;
3259 1329 1392 1405 1342 1328 1391 1404 1341;
3260 1330 1393 1406 1343 1329 1392 1405 1342;
3261 1331 1394 1407 1344 1330 1393 1406 1343;
3262 1332 1395 1408 1345 1331 1394 1407 1344;
3263 1333 1396 1409 1346 1332 1395 1408 1345;
3264 1337 1400 1413 1350 1336 1399 1412 1349;
3265 1326 1389 1402 1339 1325 1388 1401 1338;
3266 1314 1377 1390 1327 1313 1376 1389 1326;
3267 1315 1378 1391 1328 1314 1377 1390 1327;
3268 1316 1379 1392 1329 1315 1378 1391 1328;
3269 1317 1380 1393 1330 1316 1379 1392 1329;
3270 1318 1381 1394 1331 1317 1380 1393 1330;
3271 1319 1382 1395 1332 1318 1381 1394 1331;
3272 1320 1383 1396 1333 1319 1382 1395 1332;
3273 1324 1387 1400 1337 1323 1386 1399 1336;
3274 1313 1376 1389 1326 1312 1375 1388 1325;
3275 1360 1423 1435 1372 1359 1422 1434 1371;
3276 1347 1410 1423 1360 1346 1409 1422 1359;
3277 1334 1397 1410 1347 1333 1396 1409 1346;
3278 1321 1384 1397 1334 1320 1383 1396 1333;
3279 1361 1424 1436 1373 1360 1423 1435 1372;
3280 1348 1411 1424 1361 1347 1410 1423 1360;
3281 1335 1398 1411 1348 1334 1397 1410 1347;
3282 1322 1385 1398 1335 1321 1384 1397 1334;
3283 1362 1425 1218 1217 1361 1424 1436 1373;
3284 1349 1412 1425 1362 1348 1411 1424 1361;
3285 1336 1399 1412 1349 1335 1398 1411 1348;
3286 1323 1386 1399 1336 1322 1385 1398 1335;
3287 1416 1479 1042 1041 1415 1478 1491 1428;
3288 1417 1480 1492 1429 1416 1479 1042 1041;
3289 1418 1481 1493 1430 1417 1480 1492 1429;

Page 31 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
3290 1419 1482 1494 1431 1418 1481 1493 1430;
3291 1420 1483 1495 1432 1419 1482 1494 1431;
3292 1421 1484 1496 1433 1420 1483 1495 1432;
3293 1422 1485 1497 1434 1421 1484 1496 1433;
3294 1426 1489 1500 1437 1425 1488 1219 1218;
3295 1415 1478 1491 1428 1414 1477 1490 1427;
3296 1403 1466 1479 1416 1402 1465 1478 1415;
3297 1404 1467 1480 1417 1403 1466 1479 1416;
3298 1405 1468 1481 1418 1404 1467 1480 1417;
3299 1406 1469 1482 1419 1405 1468 1481 1418;
3300 1407 1470 1483 1420 1406 1469 1482 1419;
3301 1408 1471 1484 1421 1407 1470 1483 1420;
3302 1409 1472 1485 1422 1408 1471 1484 1421;
3303 1413 1476 1489 1426 1412 1475 1488 1425;
3304 1402 1465 1478 1415 1401 1464 1477 1414;
3305 1390 1453 1466 1403 1389 1452 1465 1402;
3306 1391 1454 1467 1404 1390 1453 1466 1403;
3307 1392 1455 1468 1405 1391 1454 1467 1404;
3308 1393 1456 1469 1406 1392 1455 1468 1405;
3309 1394 1457 1470 1407 1393 1456 1469 1406;
3310 1395 1458 1471 1408 1394 1457 1470 1407;
3311 1396 1459 1472 1409 1395 1458 1471 1408;
3312 1400 1463 1476 1413 1399 1462 1475 1412;
3313 1389 1452 1465 1402 1388 1451 1464 1401;
3314 1377 1440 1453 1390 1376 1439 1452 1389;
3315 1378 1441 1454 1391 1377 1440 1453 1390;
3316 1379 1442 1455 1392 1378 1441 1454 1391;
3317 1380 1443 1456 1393 1379 1442 1455 1392;
3318 1381 1444 1457 1394 1380 1443 1456 1393;
3319 1382 1445 1458 1395 1381 1444 1457 1394;
3320 1383 1446 1459 1396 1382 1445 1458 1395;
3321 1387 1450 1463 1400 1386 1449 1462 1399;
3322 1376 1439 1452 1389 1375 1438 1451 1388;
3323 1423 1486 1498 1435 1422 1485 1497 1434;
3324 1410 1473 1486 1423 1409 1472 1485 1422;
3325 1397 1460 1473 1410 1396 1459 1472 1409;
3326 1384 1447 1460 1397 1383 1446 1459 1396;
3327 1424 1487 1499 1436 1423 1486 1498 1435;
3328 1411 1474 1487 1424 1410 1473 1486 1423;
3329 1398 1461 1474 1411 1397 1460 1473 1410;
3330 1385 1448 1461 1398 1384 1447 1460 1397;
3331 1425 1488 1219 1218 1424 1487 1499 1436;
3332 1412 1475 1488 1425 1411 1474 1487 1424;
3333 1399 1462 1475 1412 1398 1461 1474 1411;
3334 1386 1449 1462 1399 1385 1448 1461 1398;
3335 1479 1542 1043 1042 1478 1541 1554 1491;
3336 1480 1543 1555 1492 1479 1542 1043 1042;
3337 1481 1544 1556 1493 1480 1543 1555 1492;
3338 1482 1545 1557 1494 1481 1544 1556 1493;
3339 1483 1546 1558 1495 1482 1545 1557 1494;
3340 1484 1547 1559 1496 1483 1546 1558 1495;
3341 1485 1548 1560 1497 1484 1547 1559 1496;
3342 1489 1552 1563 1500 1488 1551 1220 1219;
3343 1478 1541 1554 1491 1477 1540 1553 1490;
3344 1466 1529 1542 1479 1465 1528 1541 1478;

Page 32 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
3345 1467 1530 1543 1480 1466 1529 1542 1479;
3346 1468 1531 1544 1481 1467 1530 1543 1480;
3347 1469 1532 1545 1482 1468 1531 1544 1481;
3348 1470 1533 1546 1483 1469 1532 1545 1482;
3349 1471 1534 1547 1484 1470 1533 1546 1483;
3350 1472 1535 1548 1485 1471 1534 1547 1484;
3351 1476 1539 1552 1489 1475 1538 1551 1488;
3352 1465 1528 1541 1478 1464 1527 1540 1477;
3353 1453 1516 1529 1466 1452 1515 1528 1465;
3354 1454 1517 1530 1467 1453 1516 1529 1466;
3355 1455 1518 1531 1468 1454 1517 1530 1467;
3356 1456 1519 1532 1469 1455 1518 1531 1468;
3357 1457 1520 1533 1470 1456 1519 1532 1469;
3358 1458 1521 1534 1471 1457 1520 1533 1470;
3359 1459 1522 1535 1472 1458 1521 1534 1471;
3360 1463 1526 1539 1476 1462 1525 1538 1475;
3361 1452 1515 1528 1465 1451 1514 1527 1464;
3362 1440 1503 1516 1453 1439 1502 1515 1452;
3363 1441 1504 1517 1454 1440 1503 1516 1453;
3364 1442 1505 1518 1455 1441 1504 1517 1454;
3365 1443 1506 1519 1456 1442 1505 1518 1455;
3366 1444 1507 1520 1457 1443 1506 1519 1456;
3367 1445 1508 1521 1458 1444 1507 1520 1457;
3368 1446 1509 1522 1459 1445 1508 1521 1458;
3369 1450 1513 1526 1463 1449 1512 1525 1462;
3370 1439 1502 1515 1452 1438 1501 1514 1451;
3371 1486 1549 1561 1498 1485 1548 1560 1497;
3372 1473 1536 1549 1486 1472 1535 1548 1485;
3373 1460 1523 1536 1473 1459 1522 1535 1472;
3374 1447 1510 1523 1460 1446 1509 1522 1459;
3375 1487 1550 1562 1499 1486 1549 1561 1498;
3376 1474 1537 1550 1487 1473 1536 1549 1486;
3377 1461 1524 1537 1474 1460 1523 1536 1473;
3378 1448 1511 1524 1461 1447 1510 1523 1460;
3379 1488 1551 1220 1219 1487 1550 1562 1499;
3380 1475 1538 1551 1488 1474 1537 1550 1487;
3381 1462 1525 1538 1475 1461 1524 1537 1474;
3382 1449 1512 1525 1462 1448 1511 1524 1461;
3383 1542 1605 1044 1043 1541 1604 1617 1554;
3384 1543 1606 1618 1555 1542 1605 1044 1043;
3385 1544 1607 1619 1556 1543 1606 1618 1555;
3386 1545 1608 1620 1557 1544 1607 1619 1556;
3387 1546 1609 1621 1558 1545 1608 1620 1557;
3388 1547 1610 1622 1559 1546 1609 1621 1558;
3389 1548 1611 1623 1560 1547 1610 1622 1559;
3390 1552 1615 1626 1563 1551 1614 1221 1220;
3391 1541 1604 1617 1554 1540 1603 1616 1553;
3392 1529 1592 1605 1542 1528 1591 1604 1541;
3393 1530 1593 1606 1543 1529 1592 1605 1542;
3394 1531 1594 1607 1544 1530 1593 1606 1543;
3395 1532 1595 1608 1545 1531 1594 1607 1544;
3396 1533 1596 1609 1546 1532 1595 1608 1545;
3397 1534 1597 1610 1547 1533 1596 1609 1546;
3398 1535 1598 1611 1548 1534 1597 1610 1547;
3399 1539 1602 1615 1552 1538 1601 1614 1551;

Page 33 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
3400 1528 1591 1604 1541 1527 1590 1603 1540;
3401 1516 1579 1592 1529 1515 1578 1591 1528;
3402 1517 1580 1593 1530 1516 1579 1592 1529;
3403 1518 1581 1594 1531 1517 1580 1593 1530;
3404 1519 1582 1595 1532 1518 1581 1594 1531;
3405 1520 1583 1596 1533 1519 1582 1595 1532;
3406 1521 1584 1597 1534 1520 1583 1596 1533;
3407 1522 1585 1598 1535 1521 1584 1597 1534;
3408 1526 1589 1602 1539 1525 1588 1601 1538;
3409 1515 1578 1591 1528 1514 1577 1590 1527;
3410 1503 1566 1579 1516 1502 1565 1578 1515;
3411 1504 1567 1580 1517 1503 1566 1579 1516;
3412 1505 1568 1581 1518 1504 1567 1580 1517;
3413 1506 1569 1582 1519 1505 1568 1581 1518;
3414 1507 1570 1583 1520 1506 1569 1582 1519;
3415 1508 1571 1584 1521 1507 1570 1583 1520;
3416 1509 1572 1585 1522 1508 1571 1584 1521;
3417 1513 1576 1589 1526 1512 1575 1588 1525;
3418 1502 1565 1578 1515 1501 1564 1577 1514;
3419 1549 1612 1624 1561 1548 1611 1623 1560;
3420 1536 1599 1612 1549 1535 1598 1611 1548;
3421 1523 1586 1599 1536 1522 1585 1598 1535;
3422 1510 1573 1586 1523 1509 1572 1585 1522;
3423 1550 1613 1625 1562 1549 1612 1624 1561;
3424 1537 1600 1613 1550 1536 1599 1612 1549;
3425 1524 1587 1600 1537 1523 1586 1599 1536;
3426 1511 1574 1587 1524 1510 1573 1586 1523;
3427 1551 1614 1221 1220 1550 1613 1625 1562;
3428 1538 1601 1614 1551 1537 1600 1613 1550;
3429 1525 1588 1601 1538 1524 1587 1600 1537;
3430 1512 1575 1588 1525 1511 1574 1587 1524;
3431 1605 1668 1045 1044 1604 1667 1680 1617;
3432 1606 1669 1681 1618 1605 1668 1045 1044;
3433 1607 1670 1682 1619 1606 1669 1681 1618;
3434 1608 1671 1683 1620 1607 1670 1682 1619;
3435 1609 1672 1684 1621 1608 1671 1683 1620;
3436 1610 1673 1685 1622 1609 1672 1684 1621;
3437 1611 1674 1686 1623 1610 1673 1685 1622;
3438 1615 1678 1689 1626 1614 1677 1222 1221;
3439 1604 1667 1680 1617 1603 1666 1679 1616;
3440 1592 1655 1668 1605 1591 1654 1667 1604;
3441 1593 1656 1669 1606 1592 1655 1668 1605;
3442 1594 1657 1670 1607 1593 1656 1669 1606;
3443 1595 1658 1671 1608 1594 1657 1670 1607;
3444 1596 1659 1672 1609 1595 1658 1671 1608;
3445 1597 1660 1673 1610 1596 1659 1672 1609;
3446 1598 1661 1674 1611 1597 1660 1673 1610;
3447 1602 1665 1678 1615 1601 1664 1677 1614;
3448 1591 1654 1667 1604 1590 1653 1666 1603;
3449 1579 1642 1655 1592 1578 1641 1654 1591;
3450 1580 1643 1656 1593 1579 1642 1655 1592;
3451 1581 1644 1657 1594 1580 1643 1656 1593;
3452 1582 1645 1658 1595 1581 1644 1657 1594;
3453 1583 1646 1659 1596 1582 1645 1658 1595;
3454 1584 1647 1660 1597 1583 1646 1659 1596;

Page 34 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
3455 1585 1648 1661 1598 1584 1647 1660 1597;
3456 1589 1652 1665 1602 1588 1651 1664 1601;
3457 1578 1641 1654 1591 1577 1640 1653 1590;
3458 1566 1629 1642 1579 1565 1628 1641 1578;
3459 1567 1630 1643 1580 1566 1629 1642 1579;
3460 1568 1631 1644 1581 1567 1630 1643 1580;
3461 1569 1632 1645 1582 1568 1631 1644 1581;
3462 1570 1633 1646 1583 1569 1632 1645 1582;
3463 1571 1634 1647 1584 1570 1633 1646 1583;
3464 1572 1635 1648 1585 1571 1634 1647 1584;
3465 1576 1639 1652 1589 1575 1638 1651 1588;
3466 1565 1628 1641 1578 1564 1627 1640 1577;
3467 1612 1675 1687 1624 1611 1674 1686 1623;
3468 1599 1662 1675 1612 1598 1661 1674 1611;
3469 1586 1649 1662 1599 1585 1648 1661 1598;
3470 1573 1636 1649 1586 1572 1635 1648 1585;
3471 1613 1676 1688 1625 1612 1675 1687 1624;
3472 1600 1663 1676 1613 1599 1662 1675 1612;
3473 1587 1650 1663 1600 1586 1649 1662 1599;
3474 1574 1637 1650 1587 1573 1636 1649 1586;
3475 1614 1677 1222 1221 1613 1676 1688 1625;
3476 1601 1664 1677 1614 1600 1663 1676 1613;
3477 1588 1651 1664 1601 1587 1650 1663 1600;
3478 1575 1638 1651 1588 1574 1637 1650 1587;
3479 1668 1731 1046 1045 1667 1730 1743 1680;
3480 1669 1732 1744 1681 1668 1731 1046 1045;
3481 1670 1733 1745 1682 1669 1732 1744 1681;
3482 1671 1734 1746 1683 1670 1733 1745 1682;
3483 1672 1735 1747 1684 1671 1734 1746 1683;
3484 1673 1736 1748 1685 1672 1735 1747 1684;
3485 1674 1737 1749 1686 1673 1736 1748 1685;
3486 1678 1741 1752 1689 1677 1740 1223 1222;
3487 1667 1730 1743 1680 1666 1729 1742 1679;
3488 1655 1718 1731 1668 1654 1717 1730 1667;
3489 1656 1719 1732 1669 1655 1718 1731 1668;
3490 1657 1720 1733 1670 1656 1719 1732 1669;
3491 1658 1721 1734 1671 1657 1720 1733 1670;
3492 1659 1722 1735 1672 1658 1721 1734 1671;
3493 1660 1723 1736 1673 1659 1722 1735 1672;
3494 1661 1724 1737 1674 1660 1723 1736 1673;
3495 1665 1728 1741 1678 1664 1727 1740 1677;
3496 1654 1717 1730 1667 1653 1716 1729 1666;
3497 1642 1705 1718 1655 1641 1704 1717 1654;
3498 1643 1706 1719 1656 1642 1705 1718 1655;
3499 1644 1707 1720 1657 1643 1706 1719 1656;
3500 1645 1708 1721 1658 1644 1707 1720 1657;
3501 1646 1709 1722 1659 1645 1708 1721 1658;
3502 1647 1710 1723 1660 1646 1709 1722 1659;
3503 1648 1711 1724 1661 1647 1710 1723 1660;
3504 1652 1715 1728 1665 1651 1714 1727 1664;
3505 1641 1704 1717 1654 1640 1703 1716 1653;
3506 1629 1692 1705 1642 1628 1691 1704 1641;
3507 1630 1693 1706 1643 1629 1692 1705 1642;
3508 1631 1694 1707 1644 1630 1693 1706 1643;

Page 35 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
3509 1632 1695 1708 1645 1631 1694 1707 1644;
3510 1633 1696 1709 1646 1632 1695 1708 1645;
3511 1634 1697 1710 1647 1633 1696 1709 1646;
3512 1635 1698 1711 1648 1634 1697 1710 1647;
3513 1639 1702 1715 1652 1638 1701 1714 1651;
3514 1628 1691 1704 1641 1627 1690 1703 1640;
3515 1675 1738 1750 1687 1674 1737 1749 1686;
3516 1662 1725 1738 1675 1661 1724 1737 1674;
3517 1649 1712 1725 1662 1648 1711 1724 1661;
3518 1636 1699 1712 1649 1635 1698 1711 1648;
3519 1676 1739 1751 1688 1675 1738 1750 1687;
3520 1663 1726 1739 1676 1662 1725 1738 1675;
3521 1650 1713 1726 1663 1649 1712 1725 1662;
3522 1637 1700 1713 1650 1636 1699 1712 1649;
3523 1677 1740 1223 1222 1676 1739 1751 1688;
3524 1664 1727 1740 1677 1663 1726 1739 1676;
3525 1651 1714 1727 1664 1650 1713 1726 1663;
3526 1638 1701 1714 1651 1637 1700 1713 1650;
3527 1731 1794 1047 1046 1730 1793 1806 1743;
3528 1732 1795 1807 1744 1731 1794 1047 1046;
3529 1733 1796 1808 1745 1732 1795 1807 1744;
3530 1734 1797 1809 1746 1733 1796 1808 1745;
3531 1735 1798 1810 1747 1734 1797 1809 1746;
3532 1736 1799 1811 1748 1735 1798 1810 1747;
3533 1737 1800 1812 1749 1736 1799 1811 1748;
3534 1741 1804 1815 1752 1740 1803 1224 1223;
3535 1730 1793 1806 1743 1729 1792 1805 1742;
3536 1718 1781 1794 1731 1717 1780 1793 1730;
3537 1719 1782 1795 1732 1718 1781 1794 1731;
3538 1720 1783 1796 1733 1719 1782 1795 1732;
3539 1721 1784 1797 1734 1720 1783 1796 1733;
3540 1722 1785 1798 1735 1721 1784 1797 1734;
3541 1723 1786 1799 1736 1722 1785 1798 1735;
3542 1724 1787 1800 1737 1723 1786 1799 1736;
3543 1728 1791 1804 1741 1727 1790 1803 1740;
3544 1717 1780 1793 1730 1716 1779 1792 1729;
3545 1705 1768 1781 1718 1704 1767 1780 1717;
3546 1706 1769 1782 1719 1705 1768 1781 1718;
3547 1707 1770 1783 1720 1706 1769 1782 1719;
3548 1708 1771 1784 1721 1707 1770 1783 1720;
3549 1709 1772 1785 1722 1708 1771 1784 1721;
3550 1710 1773 1786 1723 1709 1772 1785 1722;
3551 1711 1774 1787 1724 1710 1773 1786 1723;
3552 1715 1778 1791 1728 1714 1777 1790 1727;
3553 1704 1767 1780 1717 1703 1766 1779 1716;
3554 1692 1755 1768 1705 1691 1754 1767 1704;
3555 1693 1756 1769 1706 1692 1755 1768 1705;
3556 1694 1757 1770 1707 1693 1756 1769 1706;
3557 1695 1758 1771 1708 1694 1757 1770 1707;
3558 1696 1759 1772 1709 1695 1758 1771 1708;
3559 1697 1760 1773 1710 1696 1759 1772 1709;
3560 1698 1761 1774 1711 1697 1760 1773 1710;
3561 1702 1765 1778 1715 1701 1764 1777 1714;
3562 1691 1754 1767 1704 1690 1753 1766 1703;
3563 1738 1801 1813 1750 1737 1800 1812 1749;

Page 36 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
3564 1725 1788 1801 1738 1724 1787 1800 1737;
3565 1712 1775 1788 1725 1711 1774 1787 1724;
3566 1699 1762 1775 1712 1698 1761 1774 1711;
3567 1739 1802 1814 1751 1738 1801 1813 1750;
3568 1726 1789 1802 1739 1725 1788 1801 1738;
3569 1713 1776 1789 1726 1712 1775 1788 1725;
3570 1700 1763 1776 1713 1699 1762 1775 1712;
3571 1740 1803 1224 1223 1739 1802 1814 1751;
3572 1727 1790 1803 1740 1726 1789 1802 1739;
3573 1714 1777 1790 1727 1713 1776 1789 1726;
3574 1701 1764 1777 1714 1700 1763 1776 1713;
3575 1794 1857 1048 1047 1793 1856 1869 1806;
3576 1795 1858 1870 1807 1794 1857 1048 1047;
3577 1796 1859 1871 1808 1795 1858 1870 1807;
3578 1797 1860 1872 1809 1796 1859 1871 1808;
3579 1798 1861 1873 1810 1797 1860 1872 1809;
3580 1799 1862 1874 1811 1798 1861 1873 1810;
3581 1800 1863 1875 1812 1799 1862 1874 1811;
3582 1804 1867 1878 1815 1803 1866 1225 1224;
3583 1793 1856 1869 1806 1792 1855 1868 1805;
3584 1781 1844 1857 1794 1780 1843 1856 1793;
3585 1782 1845 1858 1795 1781 1844 1857 1794;
3586 1783 1846 1859 1796 1782 1845 1858 1795;
3587 1784 1847 1860 1797 1783 1846 1859 1796;
3588 1785 1848 1861 1798 1784 1847 1860 1797;
3589 1786 1849 1862 1799 1785 1848 1861 1798;
3590 1787 1850 1863 1800 1786 1849 1862 1799;
3591 1791 1854 1867 1804 1790 1853 1866 1803;
3592 1780 1843 1856 1793 1779 1842 1855 1792;
3593 1768 1831 1844 1781 1767 1830 1843 1780;
3594 1769 1832 1845 1782 1768 1831 1844 1781;
3595 1770 1833 1846 1783 1769 1832 1845 1782;
3596 1771 1834 1847 1784 1770 1833 1846 1783;
3597 1772 1835 1848 1785 1771 1834 1847 1784;
3598 1773 1836 1849 1786 1772 1835 1848 1785;
3599 1774 1837 1850 1787 1773 1836 1849 1786;
3600 1778 1841 1854 1791 1777 1840 1853 1790;
3601 1767 1830 1843 1780 1766 1829 1842 1779;
3602 1755 1818 1831 1768 1754 1817 1830 1767;
3603 1756 1819 1832 1769 1755 1818 1831 1768;
3604 1757 1820 1833 1770 1756 1819 1832 1769;
3605 1758 1821 1834 1771 1757 1820 1833 1770;
3606 1759 1822 1835 1772 1758 1821 1834 1771;
3607 1760 1823 1836 1773 1759 1822 1835 1772;
3608 1761 1824 1837 1774 1760 1823 1836 1773;
3609 1765 1828 1841 1778 1764 1827 1840 1777;
3610 1754 1817 1830 1767 1753 1816 1829 1766;
3611 1801 1864 1876 1813 1800 1863 1875 1812;
3612 1788 1851 1864 1801 1787 1850 1863 1800;
3613 1775 1838 1851 1788 1774 1837 1850 1787;
3614 1762 1825 1838 1775 1761 1824 1837 1774;
3615 1802 1865 1877 1814 1801 1864 1876 1813;
3616 1789 1852 1865 1802 1788 1851 1864 1801;
3617 1776 1839 1852 1789 1775 1838 1851 1788;
3618 1763 1826 1839 1776 1762 1825 1838 1775;

Page 37 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
3619 1803 1866 1225 1224 1802 1865 1877 1814;
3620 1790 1853 1866 1803 1789 1852 1865 1802;
3621 1777 1840 1853 1790 1776 1839 1852 1789;
3622 1764 1827 1840 1777 1763 1826 1839 1776;
3623 1857 1920 1049 1048 1856 1919 1932 1869;
3624 1858 1921 1933 1870 1857 1920 1049 1048;
3625 1859 1922 1934 1871 1858 1921 1933 1870;
3626 1860 1923 1935 1872 1859 1922 1934 1871;
3627 1861 1924 1936 1873 1860 1923 1935 1872;
3628 1862 1925 1937 1874 1861 1924 1936 1873;
3629 1863 1926 1938 1875 1862 1925 1937 1874;
3630 1867 1930 1941 1878 1866 1929 1226 1225;
3631 1856 1919 1932 1869 1855 1918 1931 1868;
3632 1844 1907 1920 1857 1843 1906 1919 1856;
3633 1845 1908 1921 1858 1844 1907 1920 1857;
3634 1846 1909 1922 1859 1845 1908 1921 1858;
3635 1847 1910 1923 1860 1846 1909 1922 1859;
3636 1848 1911 1924 1861 1847 1910 1923 1860;
3637 1849 1912 1925 1862 1848 1911 1924 1861;
3638 1850 1913 1926 1863 1849 1912 1925 1862;
3639 1854 1917 1930 1867 1853 1916 1929 1866;
3640 1843 1906 1919 1856 1842 1905 1918 1855;
3641 1831 1894 1907 1844 1830 1893 1906 1843;
3642 1832 1895 1908 1845 1831 1894 1907 1844;
3643 1833 1896 1909 1846 1832 1895 1908 1845;
3644 1834 1897 1910 1847 1833 1896 1909 1846;
3645 1835 1898 1911 1848 1834 1897 1910 1847;
3646 1836 1899 1912 1849 1835 1898 1911 1848;
3647 1837 1900 1913 1850 1836 1899 1912 1849;
3648 1841 1904 1917 1854 1840 1903 1916 1853;
3649 1830 1893 1906 1843 1829 1892 1905 1842;
3650 1818 1881 1894 1831 1817 1880 1893 1830;
3651 1819 1882 1895 1832 1818 1881 1894 1831;
3652 1820 1883 1896 1833 1819 1882 1895 1832;
3653 1821 1884 1897 1834 1820 1883 1896 1833;
3654 1822 1885 1898 1835 1821 1884 1897 1834;
3655 1823 1886 1899 1836 1822 1885 1898 1835;
3656 1824 1887 1900 1837 1823 1886 1899 1836;
3657 1828 1891 1904 1841 1827 1890 1903 1840;
3658 1817 1880 1893 1830 1816 1879 1892 1829;
3659 1864 1927 1939 1876 1863 1926 1938 1875;
3660 1851 1914 1927 1864 1850 1913 1926 1863;
3661 1838 1901 1914 1851 1837 1900 1913 1850;
3662 1825 1888 1901 1838 1824 1887 1900 1837;
3663 1865 1928 1940 1877 1864 1927 1939 1876;
3664 1852 1915 1928 1865 1851 1914 1927 1864;
3665 1839 1902 1915 1852 1838 1901 1914 1851;
3666 1826 1889 1902 1839 1825 1888 1901 1838;
3667 1866 1929 1226 1225 1865 1928 1940 1877;
3668 1853 1916 1929 1866 1852 1915 1928 1865;
3669 1840 1903 1916 1853 1839 1902 1915 1852;
3670 1827 1890 1903 1840 1826 1889 1902 1839;
3671 1920 1983 1050 1049 1919 1982 1995 1932;
3672 1921 1984 1996 1933 1920 1983 1050 1049;
3673 1922 1985 1997 1934 1921 1984 1996 1933;

Page 38 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
3674 1923 1986 1998 1935 1922 1985 1997 1934;
3675 1924 1987 1999 1936 1923 1986 1998 1935;
3676 1925 1988 2000 1937 1924 1987 1999 1936;
3677 1926 1989 2001 1938 1925 1988 2000 1937;
3678 1930 1993 2004 1941 1929 1992 1227 1226;
3679 1919 1982 1995 1932 1918 1981 1994 1931;
3680 1907 1970 1983 1920 1906 1969 1982 1919;
3681 1908 1971 1984 1921 1907 1970 1983 1920;
3682 1909 1972 1985 1922 1908 1971 1984 1921;
3683 1910 1973 1986 1923 1909 1972 1985 1922;
3684 1911 1974 1987 1924 1910 1973 1986 1923;
3685 1912 1975 1988 1925 1911 1974 1987 1924;
3686 1913 1976 1989 1926 1912 1975 1988 1925;
3687 1917 1980 1993 1930 1916 1979 1992 1929;
3688 1906 1969 1982 1919 1905 1968 1981 1918;
3689 1894 1957 1970 1907 1893 1956 1969 1906;
3690 1895 1958 1971 1908 1894 1957 1970 1907;
3691 1896 1959 1972 1909 1895 1958 1971 1908;
3692 1897 1960 1973 1910 1896 1959 1972 1909;
3693 1898 1961 1974 1911 1897 1960 1973 1910;
3694 1899 1962 1975 1912 1898 1961 1974 1911;
3695 1900 1963 1976 1913 1899 1962 1975 1912;
3696 1904 1967 1980 1917 1903 1966 1979 1916;
3697 1893 1956 1969 1906 1892 1955 1968 1905;
3698 1881 1944 1957 1894 1880 1943 1956 1893;
3699 1882 1945 1958 1895 1881 1944 1957 1894;
3700 1883 1946 1959 1896 1882 1945 1958 1895;
3701 1884 1947 1960 1897 1883 1946 1959 1896;
3702 1885 1948 1961 1898 1884 1947 1960 1897;
3703 1886 1949 1962 1899 1885 1948 1961 1898;
3704 1887 1950 1963 1900 1886 1949 1962 1899;
3705 1891 1954 1967 1904 1890 1953 1966 1903;
3706 1880 1943 1956 1893 1879 1942 1955 1892;
3707 1927 1990 2002 1939 1926 1989 2001 1938;
3708 1914 1977 1990 1927 1913 1976 1989 1926;
3709 1901 1964 1977 1914 1900 1963 1976 1913;
3710 1888 1951 1964 1901 1887 1950 1963 1900;
3711 1928 1991 2003 1940 1927 1990 2002 1939;
3712 1915 1978 1991 1928 1914 1977 1990 1927;
3713 1902 1965 1978 1915 1901 1964 1977 1914;
3714 1889 1952 1965 1902 1888 1951 1964 1901;
3715 1929 1992 1227 1226 1928 1991 2003 1940;
3716 1916 1979 1992 1929 1915 1978 1991 1928;
3717 1903 1966 1979 1916 1902 1965 1978 1915;
3718 1890 1953 1966 1903 1889 1952 1965 1902;
3719 1983 783 1036 1050 1982 764 1011 1995;
3720 1984 802 1055 1996 1983 783 1036 1050;
3721 1985 821 1074 1997 1984 802 1055 1996;
3722 1986 840 1093 1998 1985 821 1074 1997;
3723 1987 859 1112 1999 1986 840 1093 1998;
3724 1988 878 1131 2000 1987 859 1112 1999;
3725 1989 897 1156 2001 1988 878 1131 2000;
3726 1993 973 1232 2004 1992 955 1214 1227;
3727 1982 764 1011 1995 1981 745 992 1994;
3728 1970 536 783 1983 1969 517 764 1982;

Page 39 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
3729 1971 555 802 1984 1970 536 783 1983;
3730 1972 574 821 1985 1971 555 802 1984;
3731 1973 593 840 1986 1972 574 821 1985;
3732 1974 612 859 1987 1973 593 840 1986;
3733 1975 631 878 1988 1974 612 859 1987;
3734 1976 650 897 1989 1975 631 878 1988;
3735 1980 726 973 1993 1979 708 955 1992;
3736 1969 517 764 1982 1968 498 745 1981;
3737 1957 289 536 1970 1956 270 517 1969;
3738 1958 308 555 1971 1957 289 536 1970;
3739 1959 327 574 1972 1958 308 555 1971;
3740 1960 346 593 1973 1959 327 574 1972;
3741 1961 365 612 1974 1960 346 593 1973;
3742 1962 384 631 1975 1961 365 612 1974;
3743 1963 403 650 1976 1962 384 631 1975;
3744 1967 479 726 1980 1966 461 708 1979;
3745 1956 270 517 1969 1955 251 498 1968;
3746 1944 42 289 1957 1943 23 270 1956; 3747 1945 61 308 1958 1944 42 289 1957;
3748 1946 80 327 1959 1945 61 308 1958; 3749 1947 99 346 1960 1946 80 327 1959;
3750 1948 118 365 1961 1947 99 346 1960;
3751 1949 137 384 1962 1948 118 365 1961;
3752 1950 156 403 1963 1949 137 384 1962;
3753 1954 232 479 1967 1953 214 461 1966;
3754 1943 23 270 1956 1942 4 251 1955;
3755 1990 915 1174 2002 1989 897 1156 2001;
3756 1977 666 915 1990 1976 650 897 1989;
3757 1964 419 666 1977 1963 403 650 1976;
3758 1951 172 419 1964 1950 156 403 1963;
3759 1991 934 1193 2003 1990 915 1174 2002;
3760 1978 685 934 1991 1977 666 915 1990;
3761 1965 438 685 1978 1964 419 666 1977;
3762 1952 191 438 1965 1951 172 419 1964;
3763 1992 955 1214 1227 1991 934 1193 2003;
3764 1979 708 955 1992 1978 685 934 1991;
3765 1966 461 708 1979 1965 438 685 1978;
3766 1953 214 461 1966 1952 191 438 1965;
3767 784 798 2005 1037 765 779 1026 1012;
3768 803 817 2006 1056 784 798 2005 1037;
3769 822 836 2007 1075 803 817 2006 1056;
3770 841 855 1108 1094 822 836 2007 1075;
START GROUP DEFINITION
JOINT
_BOLT-1 1027
_BOLT-2 1028
_BOLT-3 1038
_BOLT-4 1039
_BOLT-5 1040
_BOLT-6 1041
_BOLT-7 1042
_BOLT-8 1043
_BOLT-9 1044
_BOLT-10 1045
_BOLT-11 1046
_BOLT-12 1047
_BOLT-13 1048

Page 40 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
_BOLT-14 1049
_BOLT-15 1050
_BOLT-16 1211
_BOLT-17 1210
_BOLT-18 1215
_BOLT-19 1216
_BOLT-20 1217
_BOLT-21 1218
_BOLT-22 1219
_BOLT-23 1220
_BOLT-24 1221
_BOLT-25 1222
_BOLT-26 1223
_BOLT-27 1224
_BOLT-28 1225
_BOLT-29 1226
_BOLT-30 1227
END GROUP DEFINITION
*
**********************************************************
DEFINE MATERIAL START
ISOTROPIC RIGID
E 2.05e+010
POISSON 0.3
DENSITY 1e-006
ALPHA 1.2e-005
DAMP 0.03
ISOTROPIC CONCRETE
E 2.6587e+007
POISSON 0.17
DENSITY 25
ALPHA 1e-005
DAMP 0.03
END DEFINE MATERIAL
***************************************************
MEMBER PROPERTY AMERICAN
3113 TO 3142 PRIS YD 1
CONSTANTS
MATERIAL CONCRETE ALL
*
SUPPORTS
*
1 TO 6 19 TO 25 38 TO 44 57 TO 63 76 TO 82 95 TO 101 114 TO 120 133 TO 139 -
152 TO 158 171 TO 177 190 TO 196 209 TO 215 228 TO 234 247 1249 TO 1261 1312 -
1313 TO 1324 1375 TO 1387 1438 TO 1450 1501 TO 1513 1564 TO 1576 1627 TO 1639 -
1690 TO 1702 1753 TO 1765 1816 TO 1828 1879 TO 1891 1942 TO 1953 -
1954 ELASTIC MAT DIRECT Y SUBGRADE 34528.6 PRINT
*
DEFINE TIME HISTORY DT 0.0016
*
* AMPLITUDE FORCE = [ 12 BLOTS FOR PUMP X 0.036 + 18 BLOTS FOR MOTOR X 0.223 ] = 4.5 kN
* MACHINE RPM = 1800 RPM
*
TYPE 1 FORCE
FUNCTION SINE

Page 41 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
AMPLITUDE 4.5 RPM 1800 PHASE 0 CYCLES 60
*
TYPE 2 FORCE
FUNCTION COSINE
AMPLITUDE 4.5 RPM 1800 PHASE 0 CYCLES 60
*
ARRIVAL TIME
0
DAMPING 0.05
CUT OFF MODE SHAPE 20
******************************************************************************
LOAD 1 LOADTYPE Dead TITLE DYNAMIC
*
SELFWEIGHT X 1
*
SELFWEIGHT Y 1
*
SELFWEIGHT Z 1
*
* TOTAL MACHINE WT ASSEMBLY = 956.5 kN
* REFRE VENDOR DRAWING DEK046054
*
JOINT LOAD
1248 FX 956.5 FY 956.5 FZ 956.5
*
*
TIME LOAD
1248 FX 1 1 1.000000
1248 FY 2 1 1.000000
**********************************************************************************
CALCULATE RAYLEIGH FREQUENCY
PERFORM ANALYSIS
FINISH

Page 42 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020

Allowable peak to peak Amplitude

Speed of Rotor Maximum Allowable (Single amp.)


RPM Microns
1800 100

Calculated Peak-to-Peak Amplitude (STAAD Output)

Single Amplitude, micron Max


SL Node Position Check
X Y Z Amp.
1 1027 _BOLT-1 0.335 1.280 0.045 1.280 < 100 Safe
2 1028 _BOLT-2 0.338 1.150 0.050 1.150 < 100 Safe
3 1038 _BOLT-3 2.330 1.660 0.257 2.330 < 100 Safe
4 1039 _BOLT-4 0.343 0.895 0.071 0.895 < 100 Safe
5 1040 _BOLT-5 0.346 0.764 0.089 0.764 < 100 Safe
6 1041 _BOLT-6 0.347 0.630 0.108 0.630 < 100 Safe
7 1042 _BOLT-7 0.347 0.503 0.123 0.503 < 100 Safe
8 1043 _BOLT-8 0.348 0.391 0.113 0.391 < 100 Safe
9 1044 _BOLT-9 0.354 0.352 0.117 0.354 < 100 Safe
10 1045 _BOLT-10 0.358 0.465 0.111 0.465 < 100 Safe
11 1046 _BOLT-11 0.361 0.582 0.097 0.582 < 100 Safe
12 1047 _BOLT-12 0.360 0.715 0.080 0.715 < 100 Safe
13 1048 _BOLT-13 2.330 1.660 0.257 2.330 < 100 Safe
14 1049 _BOLT-14 0.356 0.972 0.050 0.972 < 100 Safe
15 1050 _BOLT-15 0.354 1.100 0.040 1.100 < 100 Safe
16 1211 _BOLT-16 0.337 1.270 0.045 1.270 < 100 Safe
17 1210 _BOLT-17 0.339 1.150 0.053 1.150 < 100 Safe
18 1215 _BOLT-18 0.341 1.020 0.066 1.020 < 100 Safe
19 1216 _BOLT-19 0.344 0.887 0.081 0.887 < 100 Safe
20 1217 _BOLT-20 0.347 0.756 0.098 0.756 < 100 Safe
21 1218 _BOLT-21 0.348 0.624 0.117 0.624 < 100 Safe
22 1219 _BOLT-22 0.347 0.496 0.131 0.496 < 100 Safe
23 1220 _BOLT-23 2.330 1.660 0.257 2.330 < 100 Safe
24 1221 _BOLT-24 0.355 0.355 0.127 0.355 < 100 Safe
25 1222 _BOLT-25 0.360 0.467 0.111 0.467 < 100 Safe
26 1223 _BOLT-26 0.362 0.585 0.098 0.585 < 100 Safe
27 1224 _BOLT-27 0.361 0.715 0.083 0.715 < 100 Safe
28 1225 _BOLT-28 0.360 0.844 0.068 0.844 < 100 Safe
29 1226 _BOLT-29 0.357 0.970 0.054 0.970 < 100 Safe
30 1227 _BOLT-30 0.355 1.100 0.043 1.100 < 100 Safe

Page 43 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020
Calculated Natural Frequency of foundation (STAAD Output)

Natural Frequency Period Mass Participation Factor Check


Mode No
Cycles/sec sec X,% Y,% Z,%
1 5.96 0.168 0.00 0.01 51.51 Safe
2 9.18 0.109 15.31 41.66 0.00 Safe
3 9.83 0.102 11.00 58.27 0.00 Safe
4 52.53 0.019 0.03 0.06 0.02 Safe
5 67.36 0.015 4.73 0.00 0.00 Safe
6 74.49 0.013 13.97 0.00 0.00 Safe
7 75.30 0.013 1.85 0.00 0.00 Safe
8 86.42 0.012 0.00 0.00 1.25 Safe
(Where,Y is the vertical axis. X & Z are Horizontal(orthogonal) axis)
Frequency of Pump = 1800 rpm = 30.00 cyc/sec

Foundation frequency shall be either


< 0.7 x 30 = 21 cyc/sec
or
> 1.3 x 30 = 39 cyc/sec

Page 44 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020

Node Number for Amplitude Result


Velocity of Vibrations at Machine bearing Point (STAAD Output)
(Ref. SAES-Q-007-Cl.11.1)
Velocity, mm/sec Max
Node Position Velocity, Check
X Y Z mm/s
1248 SHAFT 37.9 x E-6 51.8 x E-6 2.38 x E-6 51.8 x E-6 < 3 mm/s Safe

Displacement Graphs

Page 45 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020

Velocity Graphs for Critical Points

Page 46 of 59
.
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020

Acceleration Graphs for Critical Points

Page 47 of 59
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020

CHECK FOR OVERTURNING

Overturning Moment about X axis Ox = 1243.86+0


= 1243.86 kNm
Overturning Moment about Z axis Oz = 2720.69+0
= 2720.69 kNm
Restoring Moment about X direction Rx = 1424.9*5.81/2+(5.81/2+0)*(2127.85+956.475)+(13.08*5.81-
13.08*5.81)*0.75*18*5.81/2
= 13099.30 kNm
Restoring Moment about Z direction Rz = 1424.9*13.08/2+(13.08/2+0)*(2127.85+956.475)+(13.08*5.81-
13.08*5.81)*0.75*18*13.08/2
= 29490 kNm

Min Factor of Safety about X-direction = 13099.298625/1243.86


= 10.53 > 1.5 Safe
Min Factor of Safety about Z-direction = 29490.3315/2720.69
= 10.84 > 1.5 Safe

REINFORCEMENT CALCULATION FOR PEDESTAL BLOCK:


Min area of shrinkage reinforcement, controls = 0.18 % (Cl. 7.12.2.1, Aci-318)

Dia of bar used = 20 mm Cover to rebars = 75 mm

Ast min.= [ 1000 x 1785 x 0.18 %] Total

= 3213 mm2 Total steel


Ast required per face = 1606.5 mm2

Provided area of steel on top & bottom each ways = T 20 @ 175 mm centers.

Ast provided per face = 3590.4 mm2 Ast provided is ok

As per Clause. 10.6.7, ACI-318 M minimum area of skin reinforcement = 210 mm2 per meter of depth

Dia of bar used = 20 mm

Page 48 of 59
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area
PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020
CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020

ELEVATION

RCC DETAILS

Page 49 of 59
SUBJECT Foundation Design calculation for Shipper Pump

PROJECT DESIGNED BPK DATE 30-01-2020


Yanbu Crude Oil Terminal (YCOT)
CALC. No. MN-CAL002 CHECKED NSK DATE 30-01-2020

APPENDIX -A
Coefficients for spring constants as per Richart, F.E., Jr., Whitman, R. V.
( Ref Arya,Pincus and O'Neil)

Page 50 of 59
SUBJECT Foundation Design calculation for Shipper Pump

PROJECT DESIGNED BPK DATE 30-01-2020


Yanbu Crude Oil Terminal (YCOT)
CALC. No. MN-CAL002 CHECKED NSK DATE 30-01-2020

Figure 1

Table 1

Page 51 of 59
SUBJECT Foundation Design calculation for Shipper Pump

PROJECT DESIGNED BPK DATE 30-01-2020


Yanbu Crude Oil Terminal (YCOT)
CALC. No. MN-CAL002 CHECKED NSK DATE 30-01-2020

Spring constants

Page 52 of 59
SUBJECT Foundation Design calculation for Shipper Pump at Juaymah Tank Farm (JTF) Area

PROJECT Juaymah Terminal Onshore DESIGNED BPK DATE 30-01-2020

CALC. No. MN-CAL003 CHECKED NSK DATE 30-01-2020

APPENDIX -B
SOIL REPORT

Page 53 of 59
Page 54 of 59
Page 55 of 59
SUBJECT Foundation Design calculation for Shipper Pump

PROJECT DESIGNED BPK DATE 29-01-2020


Yanbu Crude Oil Terminal (YCOT)
CALC. No. MN-CAL002 CHECKED NSK DATE 29-01-2020

APPENDIX -C
VENDOR DRAWING

Page 56 of 59
VENDOR'S DOCUMENT No. SHEET

DEK-2945601 1 of 4
Worthington S.r.l.

G.A.DRAWING w/ NOZZLE F&M / OUTLINE / PIPING


TITLE
LAYOUT

Vendor's name: FLOWSERVE - WORTHINGTON S.r.l.


Company's name: ARAMCO
Purchaser's name: SAUDI ARAMCO
Plant Location: JUAYMAH
Project name: ARABIAN HEAVY DELIVERY TO YANBU EAST WEST PIPELINE
Purchase Order No.: 4505856118
Remarks:
Unit / Service: AH SHIPPER PUMPS
Item Number: 440-G-0563AB
Owner Doc. No.: ART
Purchaser's Doc. No.: 2019ART2945601101
Current Revision: 02
Job No. 2019ART2945601
Issued for NMR-601
Note 2
Note 3
Note 4
Sheet Size D --> A1

02 13-Jan-20 FA as per ART-FPD-email-RTN A.FRIGERIO D.COLAPIETRO C.BONACINA


01 8-Nov-19 FA as per ART-FPD-email-RTN A.FRIGERIO D.COLAPIETRO C.BONACINA
00 5-Jul-19 FOR APPROVAL A.FRIGERIO D.COLAPIETRO C.BONACINA
REV. DATE DESCRIPTION PREPARED VERIFIED APPROVED

Page 57 of 59
Page 58 of 59
23/01/2020

Recommended settings (for API pumps)


As per ES-P-06-004 (in line with API 610)
= input Pump skid 440-G-0563 A/B
= Fixed Units Of Measurements Metric
= Calculated Max. liquid temperature °C
Pump speed 1800 RPM
Pump tot. shaft power 11215 kW
No. of stages 3
Radial shaft mtl (x, y & key)
Info par. Of Thrust mtl
ES-P-06-004 Type of setting Allowable Alarm Shutdown Start perm.
1,1 Sleeve bearing Norm. 60-82 >85 >90 <90 °C
1,1 Ball bearing n.a. >95 >110 <110 °C
1,1 Tilt-pad (emb. RTD’s) n.a. >110 >115 <115 °C
1,1 Tilt-pad (spring loaded) Norm. 60-82 >85 >90 <90 °C
1,1 Oil bath n.a. >82 >87 <89 °C
Casing temperature
1,2 For HDO & WCC - - - - °C
(also see ES-P-06-004)
Casing temperature
1,2 For other pumps - - - - °C
(also see ES-P-06-004)
2,1 Radial Vibration 65 >78 >103 n.a. µm p-p
< -0.60 or < -0.70 or
2,2 Thrust displacement n.a. n.a. mm
> +0.60 > +0.70
Gap Radial shaft mtl
- n.a. n.a. n.a. Vdc
(x, y & key)
2,3
Gap Thrust mtl
- n.a. n.a. n.a. Vdc
(z)
2.4.1 Velocity 5,4 >6.4 >8.4 n.a. mm/s (RMS)
2.4.2 Acceleration 1,4 >1.7 >2.3 n.a. m/sec² true peak
2,5 Overspeed - HPRT only n.a. >1890 >2070 n.a. RPM

Recommended Alarm, Trip and Start Permissive settings for horizontal between bearing pumps,
based on and also see ES-P-06-004

Experience in motion Parallelweg 6, 4878 AH


Flowserve B.V. P.O.Box25, 4870 AA
Flow Sollutions Group Etten-Leur, The Netherlands

Page 59 of 59