Professional Documents
Culture Documents
2019 Replaces: MD 01 T IE
GEAR FLOW
DIVIDERS
Headquarters:
CASAPPA S.p.A.
Via Balestrieri, 1
43044 Lemignano di Collecchio
Parma (Italy)
Tel. (+39) 0521 30 41 11
Fax (+39) 0521 80 46 00
E-mail: info@casappa.com
www.casappa.com
Magnum
INDEX
Section Page
FEATURES.......................................................................................................................................................................... 3
GENERAL DATA.................................................................................................................................................................. 4
FLOW EQUALIZERS............................................................................................................................................................ 6
FLOW DIVIDERS................................................................................................................................................................. 8
PRESSURE INTENSIFIERS................................................................................................................................................. 10
HOW TO ORDER................................................................................................................................................................ 32
01/09.2019
2 DCAT018-ID02
Magnum
FEATURES
Modern machinery with complex kinematics often calls for multiple movements that are separate and fully indepen-
dent of each other. In flow equalization and flow division applications and for high pressure actuation, CASAPPA re-
spond with their comprehensive MAGNUM 30 and MAGNUM 35 range of flow dividing gear motors to transmit fluid
power using rational technical solutions and at low costs. When these rotary flow dividers are used for the correct
applications they permit the optimization of hydraulic circuits and improve pump life, thereby reducing installation
and operating costs. The MAGNUM series of rotary flow dividers comprise two or more independent gear sections
internally connected by a common shaft so that the ratio of the output flow from each section is proportional and
constant to its individual displacement capacity, excluding small losses in volumetric efficiency. Rotary flow dividers
do not dissipate energy. If the outlet pressure from a given section should fall below the inlet pressure then the sec-
tion will act as a motor and absorb energy from the fluid. This energy is not then wasted in the form of heat, instead
it is transferred via the common shaft to the other sections which will continue to pump since their outlet pressure
is higher than their inlet pressure. These components can be used as:
zz
Flow equalizers
zz
Flow dividers
zz
Pressure intensifiers
DISPLACEMENTS zz
Modular design
From 17,28 cm3/rev (1.05 in3/rev)
A 125,63 cm3/rev (7.66 in3/rev)
zz
Accurate division of flow
zz
High flow
PRESSURE
Max. continuous 310 bar (4500 psi) zz
Combination between different groups
Max. peak 335 bar (4800 psi)
01/09.2019
DCAT018-ID02 3
Magnum
GENERAL DATA
Mineral oil based hydraulic fluids to ISO/DIN and fire resistant fluids
Fluid [see table (1)]. For other fluids please consult our technical sales
department.
Fluid temperature range See table (1)
From 12 to 100 mm2/s (cSt) [60 to 456 SSU] recommended
Viscosity range
Up to 750 mm2/s (cSt) [3410 SSU] permitted
Filtering requirement See table (2)
Tab. 1
Temperature °C (°F)
Max pressure Max speed Seals
Type Fluid composition Max. Max.
bar (psi) min-1 Min (u)
continuous peal
(u) N = Buna N (standard) - V= Viton - N Bz= Buna N and Bronze thrust plates - V Bz=Viton and Bronze thrust plates.
4 DCAT018-ID02
Magnum
GENERAL DATA
HDD 30•17 17,28 (1.05) 310 (4500) 335 (4800) 3000 500
HDD 30•22 21,89 (1.34) 310 (4500) 335 (4800) 3000 500
HDD 30•27 26,58 (1.62) 310 (4500) 335 (4800) 3000 500
HDD 30•34 34,39 (2.10) 310 (4500) 335 (4800) 3000 500
HDD 30•43 43,77 (2.67) 310 (4500) 335 (4800) 3000 500
HDD 30•51 51,59 (3.15) 310 (4500) 335 (4800) 2500 500
HDD 30•61 60,97 (3.72) 310 (4500) 335 (4800) 2500 500
HDD 30•73 73,47 (4.48) 310 (4500) 335 (4800) 2000 500
HDD 30•82 81,29 (4.96) 310 (4500) 335 (4800) 2000 500
HDD 35•50 50,77 (3.10) 310 (4500) 335 (4800) 3000 500
HDD 35•63 63,46 (3.87) 310 (4500) 335 (4800) 3000 500
HDD 35•71 71,92 (4.39) 310 (4500) 335 (4800) 3000 500
HDD 35•80 80,39 (4.90) 310 (4500) 335 (4800) 3000 500
HDD 35•90 90,96 (5.55) 310 (4500) 335 (4800) 2700 500
HDD 35•100 99,43 (6.06) 310 (4500) 335 (4800) 2700 500
HDD 35•112 112,12 (6.84) 310 (4500) 335 (4800) 2700 500
DCAT018-ID02 5
Magnum
FLOW EQUALIZERS
Flow dividing gear motors are suited for applications where the flow must be divided equally with maximum actua-
tor synchronization difference of ± 2 %. In order to obtain synchronous operation the displacements of the gear
sections must be identical. When several single acting cylinders are operated together, acting on loads have not
sufficient mass to win the circuit’s resistance, we recommend the flow equalizer must be supplemented by a further
gear section acting as a motor in order to guarantee the cylinders retract. The displacement of this motor section
can be in the same group as the sections of the equalizer or of a different group, but it should be roughly equal to the
sum of the displacements of the other sections. Two typical circuit diagrams of applications where flow equalizers
are utilized will be found on page 19.
V1 V2 Vn
V1 = V2 .... = Vn
p0Q0
Q0 = Q1 + Q2 .... + Qn
V0
Let us assume that it is necessary to supply power to two services that require a flow rate of 100 l/min (26.42 US
gpm) each. For simplicity’s sake we will ignore pressure losses and the compression factor of the fluid. The pump
must deliver a flow equal to: Q0 = Q1 + Q2 = 200 l/min (52.84 US gpm). To find the displacement of the two sections
of the flow equalizer, assuming group HDD 30 is to be used, simply locate the flow rate 200 l/min (52.84 US gpm) on
the X axis and then ascend vertically until the line corresponding to the number of sections (2) is encountered; now
trace a horizontal line to the right until encountering the lines referring to displacement. Select the displacement with
the point of intersection on the graph that lies nearest to the maximum speed for the optimum performance range.
01/09.2019
6 DCAT018-ID02
Magnum
FLOW EQUALIZERS
2
3 170
82
(44.9)
61
73
150
(39.6)
51
43
4
120
(31.7)
5 34
HDD 30
90
6 (23.8)
27
22
NUMERO DI SEZIONI
Number of sections
60
(15.9) 17
30
(7.9)
DIAG018-001
500 400 300 200 100 0 500 1000 1500 2000 2500 3000
(132.1) (105.7) (79.3) (52.8) (26.4)
2
320
Q [l/min] - [(US gpm)]
(84.5)
125
2
11
280
0
10
3 (74.0)
240 90
(63.4) 80
4 71
200
(52.8)
63
HDD 35
5 160
(42.3) 50
6
NUMERO DI SEZIONI
Number of sections
120
01/09.2019
(31.7)
80
(21.1)
DIAG018-002
40
(10.6)
800 600 400 200 0 500 1000 1500 2000 2500 3000
(211.4) (158.5) (105.7) (52.8)
Each curve has been obtained at 50°C (122 °F), using oil with
Range for optimum performance viscosity 36 cSt (168 SSU) at 40°C (104 °F).
DCAT018-ID02 7
Magnum
FLOW DIVIDERS
These flow dividers are used where the same pump must drive several different services requiring different pressu-
res and flow rates. The displacement of each section must be proportional to the flow rate required by the service to
which it is connected. Two typical circuits in which flow dividers are installed will be found on page 20.
V1 V2 Vn
Q0 = Q1 + Q2 .... + Qn
p0Q0
1000 Q
V =
V0 n
Assume two services must be driven absorbing 100 l/min (26.42 US gpm) and 65 l/min (17.17 US gpm) respectively.
To find the displacement of the flow divider sections, assuming the HDD 30 group is opted for, simply locate the flow
rates in question on the Y axis and then move across horizontally until the lines corresponding to the displacement
are encountered. Select a displacement with points of intersection aligned as near as possible vertically, and the
nearest to the maximum speed for the optimum performance range.
01/09.2019
8 DCAT018-ID02
Magnum
FLOW DIVIDERS
170
82
61
150
73
(39.6)
51
43
PORTATA PER SEZIONE
120
34
90
(23.8)
HDD 30
27
60
22
(15.9)
17
30
(7.9)
DIAG018-003
0
0 500 1000 1500 2000 2500 3000
n [min-1]
320
Q [l/min] - [(US gpm)]
(84.5)
125
2
11
280
(74.0)
0
10
90
240
(63.4)
PORTATA PER SEZIONE
80
Flow for each section
200 71
(52.8)
63
160
HDD 35
(42.3)
50
120
(31.7)
01/09.2019
80
(21.1)
40
DIAG018-004
(10.6)
0
0 500 1000 1500 2000 2500 3000
n [min-1]
Each curve has been obtained at 50°C (122 °F), using oil with
Range for optimum performance viscosity 36 cSt (168 SSU) at 40°C (104 °F).
DCAT018-ID02 9
Magnum
PRESSURE INTENSIFIERS
Pressure intensifiers are used for services requiring working pressures in excess of the operating pressure of the
pump. Pressure is increased by using one of two sections as a motor connecting it to “tank” and the other as a
pump connecting it to the service. For optimum intensification, the ratio R between the displacement of the “motor”
and “pump” sections must fall within the range 0.5 ÷ 2. The graph on page 11 illustrates pressure intensification
available with these units. Two typical circuit diagrams incorporating pressure intensifiers are shown on page 21.
p0Q0
Q0 = Q1 + Q2
D018-D09/1212
Let us imagine that we must drive a service at a pressure of 300 bar (4350 psi) with a flow of 100 l/min (26.42 US
gpm). To find the working pressure of the main pump use graph on the facing page. First locate the pressure requi-
red by the service on the X axis and then move up vertically until the lines of ratio R. Select the displacement ratio
between the two intensifier sections R=1 and move horizontally to the left to read off the pressure value on the Y
axis p0 = 180 bar (2610 psi). Remember that R = V2 / V1 = 1
01/09.2019
10 DCAT018-ID02
Magnum
PRESSURE INTENSIFIERS
200
(2900)
[bar] - [(psi)]
180
(2610)
160
0.5
(2320) R=
PRESSIONE DI INGRESSO
140
(2030)
1
R=
Inlet pressure
120
(1740)
R=2
100
(1450)
80
(1160)
60
(870)
40
(580)
DIAG018-005
20
(290)
0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340
(290) (580) (870) (1160) (1450) (1740) (2030) (2320) (2610) (2900) (3190) (3480) (3770) (4060) (4350) (4640) (4930)
PRESSIONE INTENSIFICATA
Intensified pressure [bar] - [(psi)]
Each curve has been obtained at 50°C (122 °F), using oil with viscosity 36 cSt (168 SSU) at 40°C (104 °F).
01/09.2019
DCAT018-ID02 11
Magnum
Flow divider sections are arranged in descending displacements or groups with the largest displacement to the left
as viewed from the delivery ports side. Where flow dividers are made up of different groups, an intermediate inlet
section must be disposed between them. Standard formats of flow dividers are given beneath and on the following
pages; for different configurations please consult our Technical Sales staff.
HDD 30 C 30 • 30 ____
HDD 35 C 35 • 30 C 35 • 35
STANDARD COMPOSITION
2 SECTIONS
Max. delivery for inlet section
Type
C 30 • 30 350 (92.5)
C 35 • 30 550 (145.3)
C 35 • 35 550 (145.3)
3 SECTIONS
D018-D11/1212
01/09.2019
D018-D12/1212
12 DCAT018-ID02
Magnum
STANDARD COMPOSITION
4 SECTIONS
Max. delivery for inlet section
Type
C 30 • 30 350 (92.5)
C 35 • 30 550 (145.3)
C 35 • 35 550 (145.3)
D018-D14/1212
5 SECTIONS
D018-D15/1212
6 SECTIONS
D018-D16/1212
01/09.2019
INTERMEDIATE FLANGE
F Group HDD 30 HDD 35
D018-D24/1212
HDD 30 F 30 • 30 ____
HDD 35 F 35 • 30 F 35 • 35
MAX. 6 SECTIONS
DCAT018-ID02 13
Magnum
D018-D24/1212
Flow equalizer with motor section.
Standard version
HDD 30•17 SD SB SB MD MB MB GF GE GD OF OD OB
HDD 30•22 SD SB SB MD MB MB GF GE GD OF OD OB
HDD 30•27 SD SC SB MD MC MB GF GF GE OF OF OD
HDD 30•34 SD SC SB MD MC MB GF GF GE OF OF OD
HDD 30•43 SD SD SC MD MD MC GF GG GF OF OG OF
HDD 30•51 SD SD SC MD MD MC GF GG GF OF OG OF
HDD 30•61 SD SE SD MD ME MD GF GG GF OF OG OF
HDD 30•73 SD SE SD MD ME MD GF GG GF OF OG OF
HDD 30•82 SD SE SD MD ME MD GF GG GF OF OG OF
HDD 35•50 SE SE SD ME ME MD GH GH GG OH OG OF
HDD 35•63 SE SE SD ME ME MD GH GH GG OH OG OF
HDD 35•71 SE SE SD ME ME MD GH GH GG OH OG OF
01/09.2019
HDD 35•80 SE SE SD ME ME MD GH GH GG OH OG OF
HDD 35•90 SE SF SE ME MF ME GH GL GH OH OH OG
HDD 35•100 SE SF SE ME MF ME GH GL GH OH OH OG
HDD 35•112 SE SF SE ME MF ME GH GL GH OH OH OG
HDD 35•125 SE SF SE ME MF ME GH GL GH OH OH OG
14 DCAT018-ID02
Magnum
PORT SIZES
SAE FLANGED PORTS J518 - Standard pressure series 3000 PSI SSS
American straight thread UNC-UNF 60° conforms to ANSI B 1.1
A B C D
CODE
mm mm mm Thread Nm
(in) (in) (in) Depth mm (in) (lbf in)
19 47,6 22,2 3/8 - 16 UNC-2B 30 +2,5
SB (0.75) (1.87) (0.87) 22 (0.87) (266 ÷ 288)
D010-D15/1212
25,4 52,4 26,2 3/8 - 16 UNC-2B 30 +2,5
SC (1.00) (2.06) (1.03) 22 (0.87) (266 ÷ 288)
30,5 58,7 30,2 7/16 - 14 UNC-2B 55 +5
SD (1.20) (2.31) (1.19) 28,5 (1.12) (487 ÷ 531)
39,3 69,8 35,7 1/2 - 13 UNC-2B 70 +5
SE (1.55) (2.75) (1.40) 27 (1.06) (620 ÷ 664)
51 77,8 42,9 1/2 - 13 UNC-2B 90 +5
SF (2.00) (3.06) (1.69) 27 (1.06) (797 ÷ 841)
SAE FLANGED PORTS J518 - Standard pressure series 3000 PSI SSM
Metric thread ISO 60° conforms to ISO/R 262
A B C D
CODE
mm mm mm Thread Nm
(in) (in) (in) Depth mm (in) (lbf in)
19 47,6 22,2 M 10 35 +2,5
MB (0.75) (1.87) (0.87) 22 (0.87) (310 ÷ 332)
D010-D15/1212
DCAT018-ID02 15
Magnum
PORT SIZES
Nominal
B C
CODE
size
A
mm mm Nm
(in) (in) (lbf in)
D010-D16/1212
18 19 50 +2,5
GD 1/2” G 1/2
(0.71) (0.75) (443 ÷ 465)
20 24,5 90 +5
GE 3/4” G 3/4
(0.79) (0.96) (797 ÷ 841)
22 30,5 130 +10
GF 1” G1
(0.87) (1.20) (1151 ÷ 1239)
24 39,3 170 +15
GG 1” 1/4 G 1 1/4
(0.94) (1.55) (1505 ÷ 1637)
26 45 210 +15
GH 1” 1/2 G 1 1/2
(1.02) (1.77) (1859 ÷ 1991)
32 56 400 +20
GL 2” G2
(1.26) (2.20) (3540 ÷ 3717)
Nominal
B C D E
CODE
size
A
mm mm mm mm Nm
(in) (in) (in) (in) (lbf in)
01/09.2019
16 DCAT018-ID02
Magnum
26 26
[1.0236] [1.0236]
D018-D01/1212
Ø 13
[0.5118]
70 Elemento terminale Collettore Elemento intermedio Elemento terminale
[2.7559] End section Inlet section Intermediate section End section
A B C D E F G H
Flow divider type mm mm mm mm mm mm mm mm
(in) (in) (in) (in) (in) (in) (in) (in)
155 57 70 + E 77 70 75 110
HDD 30 + HDD 30 (6.10) (2.24) (2.76 + E) (3.03)
See below
(2.76) (2.95) (4.33)
175 63 82 + E 93 82 87,5 135
HDD 35 + HDD 35 (6.89) (2.48) (3.23 + E) (3.66)
See below
(3.23) (3.44) (5.32)
E E
Flow divider type mm Flow divider type mm
(in) (in)
23 38
HDD 30•17 (0.91)
HDD 35•50 (1.50)
26 44
HDD 30•22 (1.02)
HDD 35•63 (1.73)
29 48
HDD 30•27 (1.14)
HDD 35•71 (1.89)
34 52
HDD 30•34 (1.34)
HDD 35•80 (2.05)
01/09.2019
40 57
HDD 30•43 (1.57)
HDD 35•90 (2.24)
45 61
HDD 30•51 (1.77)
HDD 35•100 (2.40)
51 67
HDD 30•61 (2.01)
HDD 35•112 (2.64)
59 73
HDD 30•73 (2.32)
HDD 35•125 (2.87)
64
HDD 30•82 (2.52)
DCAT018-ID02 17
Magnum
175
[6.8898]
155 26 63 57 26
[6.1024] [1.0236] [2.4803] [2.2441] [1.0236]
[3.4449]
87,5
[5.3150]
135
82 70
[3.2283] [2.7559]
[1.1378]
D018-D02/1212
28,9
Ø 13 93 77
[0.5118] [3.6614] [3.0315]
70 Elemento terminale Collettore Elemento intermedio Elemento terminale
[2.7559] End section Inlet section Intermediate section End section
A B C
Flow divider type mm mm mm
(in) (in) (in)
82 + D 76 + E 70 + E
HDD 35 + HDD 30 (3.23 + D) (2.99 + E) (2.76 + E)
E E
Flow divider type mm Flow divider type mm
(in) (in)
23 23
HDD 35•50 (0.91)
HDD 30•17 (0.91)
26 26
HDD 30•22 (1.02)
HDD 30•22 (1.02)
29 29
HDD 30•27 (1.14)
HDD 30•27 (1.14)
34 34
HDD 30•34 (1.34)
HDD 30•34 (1.34)
01/09.2019
40 40
HDD 30•43 (1.57)
HDD 30•43 (1.57)
45 45
HDD 30•51 (1.77)
HDD 30•51 (1.77)
51 51
HDD 30•61 (2.01)
HDD 30•61 (2.01)
59 59
HDD 30•73 (2.32)
HDD 30•73 (2.32)
64 64
HDD 30•82 (2.52)
HDD 30•82 (2.52)
18 DCAT018-ID02
Magnum
Diagram with a flow divider permitting the use of a single pump Diagram with a flow divider permitting the use of a single pump
to drive a number of different services requiring flows at diffe- to drive a number of different services requiring flows at diffe-
rent pressures. rent pressures.
DCAT018-ID02 19
Magnum
01/09.2019
Diagram with a flow divider permitting the use of a single Diagram with a flow divider permitting the use of a single
pump to drive a number of different services requiring flows at pump to drive a number of different services requiring flows at
different pressures. different pressures.
20 DCAT018-ID02
Magnum
Diagram with pressure intensifier so that a service requiring a Diagram with pressure intensifier so that a service requiring a
pressure higher than the pressure available at the main delivery pressure higher than the pressure available at the main delivery
pump can be driven. pump can be driven.
DCAT018-ID02 21
Magnum
D018-D25/1212
A B C D E F G H I
Type
mm mm mm mm mm mm mm mm
Screws O-ring
(in) (in) (in) (in) (in) (in) (in) (in)
13 19 16 36 54 38,1 17,5 46 M8
RD2-MA/FG12-N G 1/2 4075
(0.51) (0.75) (0.63) (1.42) (2.13) (1.50) (0.69) (1.81) UNI 5931-8.8
13 19 16 36 54 38,1 17,5 46 M8
RD2-MA/FG38-N G 3/8 4075
(0.51) (0.75) (0.63) (1.42) (2.13) (1.50) (0.69) (1.81) UNI 5931-8.8
19 19 18 36 65 47,6 22,2 50 M 10
RD2-MB/FG34-N G 3/4 4100
(0.75) (0.75) (0.71) (1.42) (2.56) (1.87) (0.87) (1.97) UNI 5931-8.8
13 19 18 36 65 47,6 22,2 50 M 10
RD2-MB/FG12-N G 1/2 4100
(0.51) (0.75) (0.71 (1.42) (2.56) (1.87) (0.87) (1.97) UNI 5931-8.8
25 19 18 38 70 52,4 26,2 52 M 10
RD2-MC/FG100-N G1 4131
(0.98) (0.75) (0.71) (1.50) (2.76) (1.06) (1.03) (2.05) UNI 5931-8.8
19 19 18 38 70 52,4 26,2 52 M 10
RD2-MC/FG34-N G 3/4 4131
(0.75) (0.75) (0.71) (1.50) (2.76) (1.06) (1.03) (2.05) UNI 5931-8.8
32 22 21 41 79 58,7 30,2 68 M 10
RD2-MD/FG114-N G 1 1/4 4150
(1.26) (0.87) (0.83) (1.61) (3.11) (2.31) (1.19) (2.68) UNI 593-12.9
25 22 21 41 79 58,7 30,2 68 M 10
RD2-MD/FG100-N G1 4150
(0.98) (0.87) (0.83) (1.61) (3.11) (2.31) (1.19) (2.68) UNI 593-12.9
38 24 25 44 93 69,8 35,7 78 M 12
RD2-ME/FG112-N G 1 1/2 4187
(1.50) (0.94) (0.98) (1.73) (3.66) (2.75) (1.41) (3.07) UNI 593-12.9
32 24 25 44 93 69,8 35,7 78 M 12
RD2-ME/FG114-N G 1 1/4 4187
(1.26) (0.94) (0.98) (1.73) (3.66) (2.75) (1.41) (3.07) UNI 593-12.9
51 30 25 45 102 77,8 42,9 90 M 12
RD2-MF/FG200-N G2 4225
(2.01) (1.18) (0.98) (1.77) (4.02) (3.06) (1.69) (3.54) UNI 593-12.9
38 26 25 45 102 77,8 42,9 90 M 12
RD2-MF/FG112-N G 1 1/2 4225
(1.50) (1.02) (0.98) (1.77) (4.02) (3.06) (1.69) (3.54) UNI 593-12.9
01/09.2019
22 DCAT018-ID02
Magnum
A B C D E F G H I
Type Screws O-ring
mm mm mm mm mm mm mm mm
(in) (in) (in) (in) (in) (in) (in) (in)
13 19 16 36 54 38,1 17,5 46 5/16
RD2-SA/FG12-N G 1/2 4075
(0.51) (0.75) (0.63) (1.42) (2.13) (1.50) (0.69) (1.81) -18 UNC-2B
13 19 16 36 54 38,1 17,5 46 5/16
RD2-SA/FG38-N G 3/8 4075
(0.51) (0.75) (0.63) (1.42) (2.13 (1.50) (0.69) (1.81) -18 UNC-2B
19 19 18 36 65 47,6 22,2 50 3/8
RD2-SB/FG34-N G 3/4 4100
(0.75) (0.75) (0.71) (1.42) (2.56) (1.87) (0.87) (1.97) -16 UNC-2B
13 19 18 36 65 47,6 22,2 50 3/8
RD2-SB/FG12-N G 1/2 4100
(0.51) (0.75) (0.71) (1.42) (2.56) (1.87) (0.87) (1.97) -16 UNC-2B
25 19 18 38 70 52,4 26,2 52 3/8
RD2-SC/FG100-N G1 4131
(0.98) (0.75) (0.71) (1.50) (2.76) (2.06) (1.03) (2.05) -16 UNC-2B
19 19 18 38 70 52,4 26,2 52 3/8
RD2-SC/FG34-N G 3/4 4131
(0.75) (0.7) (0.71) (1.50) (2.76) (2.06) (1.03) (2.05) -16 UNC-2B
32 22 21 41 79 58,7 30,2 68 7/16
RD2-SD/FG114-N G 1 1/4 4150
(1.26) (0.87) (0.83) (1.61) (3.11) (2.31) (1.19) (2.68) -14 UNC-2B
25 22 21 41 79 58,7 30,2 68 7/16
RD2-SD/FG100-N G1 4150
(0.98) (0.87) (0.83) (1.61) (3.11) (2.31) (1.19) (2.68) -14 UNC-2B
38 24 25 44 93 69,8 35,7 78 1/2
RD2-SE/FG112-N G 1 1/2 4187
(1.50) (0.94) (0.98) (1.73) (3.66) (2.75) (1.41) (3.07) -14 UNC-2B
32 24 25 44 93 69,8 35,7 78 1/2
RD2-SE/FG114-N G 1 1/4 4187
(1.26) (0.94) (0.98) (1.73) (3.66) (2.75) (1.41) (3.07) -14 UNC-2B
51 30 25 45 102 77,8 42,9 90 1/2
RD2-SF/FG200-N G2 4225
(2.01) (1.18) (0.98) (1.77) (4.02) (3.06) (1.69) (3.54) -14 UNC-2B
38 26 25 45 102 77,8 42,9 90 1/2
RD2-SF/FG112-N G 1 1/2 4225
(1.50) (1.02) (0.98) (1.77) (4.02) (3.06) (1.69) (3.54) -14 UNC-2B
Standard port connectors are equipped with BUNA seals. For heavier operating conditions, require it with VITON seals repla-
ceing code’s last letter N with the V letter. (eg. RD2-MA/FG12-N - RD2-MA/FG12-V).
Note: Torque values in the table refer to the mounting of port connectors on MAGNUM series.
01/09.2019
DCAT018-ID02 23
Magnum
D018-D25/1212
A B C D E F G H I
Type Screws O-ring
mm mm mm mm mm mm mm mm
(in) (in) (in) (in) (in) (in) (in) (in)
13 19 16 36 54 38,1 17,5 46 M8
RD2-MA/FN12-N 1/2 NPT
(0.51) (0.75) (0.63) (1.42) (2.13) (1.50) (0.69) (1.81) UNI 5931-8.8
4075
13 19 16 36 54 38,1 17,5 46 M8
RD2-MA/FN38-N 3/8 NPT
(0.51) (0.75) (0.63) (1.42) (2.13) (1.50) (0.69) (1.81) UNI 5931-8.8
4075
19 19 18 36 65 47,6 22,2 50 M 10
RD2-MB/FN34-N 3/4 NPT
(0.75) (0.75) (0.71) (1.42) (2.56) (1.87) (0.87) (1.97) UNI 5931-8.8
4100
13 19 18 36 65 47,6 22,2 50 M 10
RD2-MB/FN12-N 1/2 NPT
(0.51) (0.75) (0.71) (1.42) (2.56) (1.87) (0.87) (1.97) UNI 5931-8.8
4100
25 19 18 38 70 52,4 26,2 52 M 10
RD2-MC/FN100-N 1 NPT
(0.98) (0.75) (0.71) (1.50) (2.76) (2.06) (1.03) (2.05) UNI 5931-8.8
4131
19 19 18 38 70 52,4 26,2 52 M 10
RD2-MC/FN34-N 3/4 NPT
(0.75) (0.75) (0.71) (1.50) (2.76) (2.06) (1.03) (2.05) UNI 5931-8.8
4131
32 22 21 41 79 58,7 30,2 68 M 10
RD2-MD/FN114-N 1 1/4 NPT
(1.26) (0.87) (0.83) (1.61) (3.11) (2.31) (1.19) (2.68) UNI 593-12.9
4150
25 22 21 41 79 58,7 30,2 68 M 10
RD2-MD/FN100-N 1 NPT 4150
(0.98) (0.87) (0.83) (1.61) (3.11) (2.31) (1.19) (2.68) UNI 593-12.9
38 24 25 44 93 69,8 35,7 78 M 12
RD2-ME/FN112-N 1 1/2 NPT
(1.50) (0.94) (0.98) (1.73) (3.66) (2.75) (1.41) (3.07) UNI 593-12.9
4187
32 24 25 44 93 69,8 35,7 78 M 12
RD2-ME/FN114-N 1 1/4 NPT
(1.26) (0.94) (0.98) (1.73) (3.66) (2.75) (1.41) (3.07) UNI 593-12.9
4187
51 30 25 45 102 77,8 42,9 90 M 12
RD2-MF/FN200-N 2 NPT
(2.01) (1.18) (0.98) (1.77) (4.02) (3.063) (1.69) (3.54) UNI 593-12.9
4225
38 26 25 45 102 77,8 42,9 90 M 12
RD2-MF/FN112-N 1 1/2 NPT
(1.50) (1.02) (0.98) (1.77) (4.02) (3.06) (1.69) (3.54) UNI 593-12.9
4225
01/09.2019
24 DCAT018-ID02
Magnum
A B C D E F G H I
Type Screws O-ring
mm mm mm mm mm mm mm mm
(in) (in) (in) (in) (in) (in) (in) (in)
13 19 16 36 54 38,1 17,5 46 5/16
RD2-SA/FN12-N 1/2 NPT 4075
(0.51) (0.75) (0.63) (1.42) (2.13) (1.50) (0.69) (1.81) -18 UNC-2B
13 19 16 36 54 38,1 17,5 46 5/16
RD2-SA/FN38-N 3/8 NPT 4075
(0.51) (0.75) (0.63) (1.42) (2.13) (1.50) (0.69) (1.81) -18 UNC-2B
19 19 18 36 65 47,6 22,2 50 3/8
RD2-SB/FN34-N 3/4 NPT 4100
(0.75) (0.75) (0.71) (1.42) (2.56) (1.87) (0.87) (1.967) -16 UNC-2B
13 19 18 36 65 47,6 22,2 50 3/8
RD2-SB/FN12-N 1/2 NPT 4100
(0.5118) (0.75) (0.71) (1.42) (2.56) (1.87) (0.87) (1.97) -16 UNC-2B
25 19 18 38 70 52,4 26,2 52 3/8
RD2-SC/FN100-N 1 NPT 4131
(0.98) (0.75) (0.71) (1.50) (2.76) (2.06) (1.03) (2.05) -16 UNC-2B
19 19 18 38 70 52,4 26,2 52 3/8
RD2-SC/FN34-N 3/4 NPT 4131
(0.75) (0.75) (0.71) (1.50) (2.76) (2.06) (1.03) (2.05) -16 UNC-2B
1 1/4 32 22 21 41 79 58,7 30,2 68 7/16
RD2-SD/FN114-N 4150
NPT (1.26) (0.87) (0.83) (1.61) (3.11) (2.31) (1.19) (2.68) -14 UNC-2B
25 22 21 41 79 58,7 30,2 68 7/16
RD2-SD/FN100-N 1 NPT 4150
(0.98) (0.87) (0.83) (1.61) (3.11) (2.31) (1.19) (2.68) -14 UNC-2B
1 1/2 38 24 25 44 93 69,8 35,7 78 1/2
RD2-SE/FN112-N 4187
NPT (1.50) (0.94) (0.98) (1.73) (3.66) (2.75) (1.41) (3.07) -14 UNC-2B
1 1/4 32 24 25 44 93 69,8 35,7 78 1/2
RD2-SE/FN114-N 4187
NPT (1.26) (0.94) (0.98) (1.73) (3.66) (2.75) (1.41) (3.07) -14 UNC-2B
51 30 25 45 102 77,8 42,9 90 1/2
RD2-SF/FN200-N 2 NPT 4225
(2.01) (1.18) (0.98) (1.77) (4.02) (3.06) (1.69) (3.543) -14 UNC-2B
1 1/2 38 26 25 45 102 77,8 42,9 90 1/2
RD2-SF/FN112-N 4225
NPT (1.50) (1.02) (0.98) (1.77) (4.02) (3.06) (1.69) (3.54) -14 UNC-2B
Standard port connectors are equipped with BUNA seals. For heavier operating conditions, require it with VITON seals repla-
ceing code’s last letter N with the V letter (eg. RD2-MA/FN12-N - RD2-MA/FN12-V).
Note: Torque values in the table refer to the mounting of port connectors on MAGNUM series.
01/09.2019
DCAT018-ID02 25
Magnum
D018-D27/1212
A B C D E F G H I
Nom.
Type
size
Screws O-ring
mm mm mm mm mm mm mm mm
(in) (in) (in) (in) (in) (in) (in) (in)
21,6 13 19 16 36 54 38,1 17,5 46 M8
RD2-MA/S12-N 1/2”
(0.85) (0.51) (0.75) (0.63) (1.42) (2.13) (1.50) (0.69) (1.81) UNI 5931-8.8
4075
34 25 19 18 38 70 52,4 26,2 52 M 10
RD2-MC/S100-N 1”
(1.34) (0.98) (0.75) (0.71) (1.50) (2.76) (2.06) (1.03) (2.05) UNI 5931-8.8
4131
A B C D E F G H I
Nom.
Type
size
Screws O-ring
mm mm mm mm mm mm mm mm
(in) (in) (in) (in) (in) (in) (in) (in)
21,6 13 19 16 36 54 38,1 17,5 46 5/16
RD2-SA/S12-N 1/2”
(0.85) (0.51) (0.75) (0.63) (1.42) (2.13) (1.50) (0.69) (1.81) -18 UNC-2B
4075
(1.69) (1.26) (0.87) (0.83) (1.61) (3.11) (2.31) (1.19) (2.68) -14 UNC-2B
48,6 38 24 25 44 93 69,8 35,7 78 1/2
RD2-SE/S112-N 1” 1/2
(1.91) (1.50) (0.94) (0.98) (1.73) (3.66) (2.75) (1.41) (3.07) -14 UNC-2B
4187
Standard port connectors are equipped with BUNA seals. For heavier operating conditions, require it with VITON seals repla-
ceing code’s last letter N with the V letter (eg. RD2-MA/S12-N - RD2-MA/S12-V).
Note: Torque values in the table refer to the mounting of port connectors on MAGNUM series.
26 DCAT018-ID02
Magnum
D018-D28/1212
A B C D E F G H
Nom.
Type
size
Screws O-ring
mm mm mm mm mm mm mm
(in) (in) (in) (in) (in) (in) (in)
21,6 13 16 36 54 38,1 17,5 46 M8
RD2-MA/T12-N 1/2” 4075
(0.85) (0.51) (0.63) (1.42) (2.13) (1.50) (0.69) (1.81) UNI 5931-8.8
17,5 13 16 36 54 38,1 17,5 46 M8
RD2-MA/T38-N 3/8” 4075
(0.69) (0.51) (0.63) (1.42) (2.13) (1.50) (0.69) (1.81) UNI 5931-8.8
27,2 19 18 36 65 47,6 22,2 50 M 10
RD2-MB/T34-N 3/4” 4100
(1.07) (0.75) (0.71) (1.42) (2.56) (1.87) (0.87) (1.97) UNI 5931-8.8
34 25 18 38 70 52,4 26,2 52 M 10
RD2-MC/T100-N 1” 4131
(1.34) (0.98) (0.71) (1.50) (2.76) (2.06) (1.03) (2.05) UNI 5931-8.8
42,8 32 21 41 79 58,7 30,2 68 M 10
RD2-MD/T114-N 1” 1/4 4150
(1.69) (1.26) (0.83) (1.61) (3.11) (2.31) (1.19) (2.68) UNI 593-12.9
48,6 38 25 44 93 69,8 35,7 78 M 12
RD2-ME/T112-N 1” 1/2 4187
(1.91) (1.50) (0.98) (1.73) (3.66) (2.75) (1.41) (3.07) UNI 593-12.9
61 51 25 45 102 77,8 42,9 90 M 12
RD2-MF/T200-N 2” 4225
(2.40) (2.01) (0.98) (1.77) (4.02) (3.06) (1.69) (3.54) UNI 593-12.9
A B C D E F G H
Nom.
Type
size
Screws O-ring
mm mm mm mm mm mm mm
(in) (in) (in) (in) (in) (in) (in)
21,6 13 16 36 54 38,1 17,5 46 5/16
RD2-SA/T12-N 1/2” 4075
(0.85) (0.51) (0.63) (1.42) (2.13) (1.50) (0.69) (1.81) -18 UNC-2B
17,5 13 16 36 54 38,1 17,5 46 5/16
RD2-SA/T38-N 3/8” 4075
(0.69) (0.51) (0.63) (1.42) (2.13) (1.50) (0.69) (1.81) -18 UNC-2B
27,2 19 18 36 65 47,6 22,2 50 3/8
RD2-SB/T34-N 3/4” 4100
(1.07) (0.75) (0.71) (1.42) (2.56) (1.87) (0.87) (1.97) -16 UNC-2B
34 25 18 38 70 52,4 26,2 52 3/8
RD2-SC/T100-N 1” 4131
(1.34) (0.98) (0.71) (1.50) (2.76) (2.06) (1.03) (2.05) -16 UNC-2B
01/09.2019
Standard port connectors are equipped with BUNA seals. For heavier operating conditions, require it with VITON seals repla-
ceing code’s last letter N with the V letter (eg. RD2-MA/T12-N - RD2-MA/T12-V).
Note: Torque values in the table refer to the mounting of port connectors on MAGNUM series.
DCAT018-ID02 27
Magnum
D018-D26/1212
A B C D E F G H
Type Screws O-ring
mm mm mm mm mm mm mm
Nominal size
(in) (in) (in) (in) (in) (in) (in)
G 3/4 Depth 19 19 19 38 66 47,6 22,2 46 M 10
RG2-MB/FG34-N 4100
(0.75) (0.75) (0.75) (1.50) (2.60) (1.87) (0.87) (1.81) UNI 5931-8.8
G 1 Depth 19 25 22 45 71 52,4 26,2 55 M 10
RG2-MC/FG100-N 4131
(0.75) (0.98) (0.87) (1.77) (2.80) (2.06) (1.03) (2.17) UNI 5931-8.8
G 1 1/4 Depth 22 31 27 55 81 58,7 30,2 65 M 10
RG2-MD/FG114-N 4150
(0.87) (1.22) (1.06) (2.17) (3.19) (2.31) (1.19) (2.56) UNI 5931-12.9
G 1 1/2 Depth 24 38 32 65 95 69,8 35,7 75 M 12
RG2-ME/FG112-N 4187
(0.94) (1.50) (1.26) (2.56) (3.74) (2.75) (1.41) (2.95) UNI 5931-12.9
M 12
G 2 Depth 26 51 40 80 112 77,8 42,9 90
RG2-MF/FG200-N UNI 5931- 4237
(1.02) (2.01) (1.57) (3.15) (4.41) (3.06) (1.69) (3.54)
12.9
Standard port connectors are equipped with BUNA seals. For heavier operating conditions, require it with VITON seals repla-
ceing code’s last letter N with the V letter (eg. RG2-MB/FG34-N - RG2-MB/FG34-V).
Note: Torque values in the table refer to the mounting of port connectors on MAGNUM series.
01/09.2019
28 DCAT018-ID02
Magnum
D018-D26/1212
A B C D E F G H
Type Screws O-ring
mm mm mm mm mm mm mm
Nominal size
(in) (in) (in) (in) (in) (in) (in)
3/4 NPT Depth 19 19 19 38 66 47,6 22,2 46 M 10
RG2-MB/FN34-N 4100
(0.75) (0.75) (0.75) (1.50) (2.60) (1.87) (0.87) (1.81) UNI 5931-8.8
1 NPT Depth 19 25 22 45 71 52,4 26,2 55 M 10
RG2-MC/FN100-N 4131
(0.75) (0.98) (0.87) (1.77) (2.80) (2.06) (1.03) (2.17) UNI 5931-8.8
1 1/4 NPT Depth 22 31 27 55 81 58,7 30,2 65 M 10
RG2-MD/FN114-N 4150
(0.87) (1.22) (1.06) (2.17) (3.19) (2.31) (1.19) (2.56) UNI 5931-12.9
1 1/2 NPT Depth 24 38 32 65 95 69,8 35,7 75 M 12
RG2-ME/FN112-N 4187
(0.94) (1.50) (1.26) (2.56) (3.74) (2.75) (1.41) (2.95) UNI 5931-12.9
2 NPT Depth 26 51 40 80 112 77,8 42,9 90 M 12
RG2-MF/FN200-N 4237
(1.02) (2.01) (1.57) (3.15) (4.41) (3.06) (1.69) (3.54) UNI 5931-12.9
Standard port connectors are equipped with BUNA seals. For heavier operating conditions, require it with VITON seals repla-
ceing code’s last letter N with the V letter (eg. RG2-MB/FN34-N - RG2-MB/FN34-V).
Note: Torque values in the table refer to the mounting of port connectors on MAGNUM series.
01/09.2019
DCAT018-ID02 29
Magnum
D018-D29/1212
A B C D E F G H I
Nom.
Type
size
Screws O-ring
mm mm mm mm mm mm mm mm
(in) (in) (in) (in) (in) (in) (in) (in)
27,2 19 19 38 66 47,6 22,2 5 46 M 10
RG2-MB/S34-N 3/4” 4100
(1.07) (0.75) (0.75) (1.50) (2.60) (1.87) (0.87) (0.20) (1.81) UNI 5931-8.8
34 25 22 45 71 52,4 26,2 6 55 M 10
RG2-MC/S100-N 1” 4131
(1.34) (0.98) (0.87) (1.77) (2.80) (2.06) (1.03) (0.24) (2.17) UNI 5931-8.8
42,8 31 27 55 81 58,7 30,2 7 65 M 10
RG2-MD/S114-N 1” 1/4 4150
(1.69) (1.22) (1.06) (2.17) (3.19) (2.31) (1.19) (0.28) (2.56) UNI 593-12.9
48,6 38 32 65 95 69,8 35,7 8 75 M 12
RG2-ME/S112-N 1” 1/2 4187
(1.91) (1.50) (1.26) (2.56) (3.74) (2.75) (1.41) (0.32) (2.95) UNI 593-12.9
61,3 51 40 80 112 77,8 42,9 10 90 M 12
RG2-MF/S200-N 2” 4225
(2.41) (2.01) (1.57) (3.15) (4.41) (3.06) (1.69) (0.39) (3.54) UNI 593-12.9
Standard port connectors are equipped with BUNA seals. For heavier operating conditions, require it with VITON seals repla-
ceing code’s last letter N with the V letter. (esempio: RG2-MB/S34-N - RG2-MB/S34-V).
Note: Torque values in the table refer to the mounting of port connectors on MAGNUM series.
01/09.2019
30 DCAT018-ID02
Magnum
D018-D30/1212
A B C D E F G H I
Nom.
Type
size
Screws O-ring
mm mm mm mm mm mm mm mm
(in) (in) (in) (in) (in) (in) (in) (in)
27 19 23 38 70 47,6 22,2 44 63 M 10
RG2-MB/T34-N 3/4” 4100
(1.06) (0.75) (0.91) (1.50) (2.76) (1.87) (0.87) (1.73) (2.48) UNI 5931-8.8
34,5 23 25 42 75 52,4 26,2 48 72 M 10
RG2-MC/T100-N 1” 4112
(1.36) (0.91) (0.98) (1.65) (2.95) (2.06) (1.03) (1.89) (2.83) UNI 5931-8.8
43 31 27 48 86 58,7 30,2 56 82 M 10
RG2-MD/T114-N 1” 1/4 4150
(1.69) (1.22) (1.06) (1.89) (3.39) (2.31) (1.19) (2.20) (3.23) UNI 593-12.9
50 35 31,5 56 97 69,8 35,7 62 92 M 12
RG2-ME/T112-N 1” 1/2 150
(1.97) (1.38) (1.24 (2.20) (3.82) (2.75) (1.41) (2.44) (3.62) UNI 593-12.9
65 48 37,5 60 100 77,8 42,9 72 99 M 12
RG2-MF/T200-N 2” 156
(2.56) (1.89) (1.48) (2.36) (3.94) (3.06) (1.69) (2.83) (3.90) UNI 593-12.9
Standard port connectors are equipped with BUNA seals. For heavier operating conditions, require it with VITON seals repla-
ceing code’s last letter N with the V letter (eg. RG2-MB/T34-N - RG2-MB/T34-V).
Nota: Torque values in the table refer to the mounting of port connectors on MAGNUM series.
01/09.2019
DCAT018-ID02 31
Magnum
HOW TO ORDER
ME MD
D018-D14/1212
ME MC MB MB
HDD 35•90 - / ME - N - T
C 35•30 - ME
HDD 30• 51 - / MC - N - I
HDD 30• 27 - MD / MB - N - I
HDD 30• 17 - / MB - N - T
01/09.2019
32 DCAT018-ID02
Magnum
ME MD
D018-D24/1212
ME MC MC
HDD 35•90 - / ME - N - T
F 35•30
HDD 30• 43 - MD / MC - N - I
HDD 30• 43 - / MC - N - T
01/09.2019
DCAT018-ID02 33
Magnum
34 DCAT018-ID02
Our policy is one of continuous improvement in product. Specification of items may, therefore, be changed without
notice.
MD 01 T A Edition: 01/09.2019 Replaces: MD 01 T IE
GEAR FLOW
DIVIDERS
Headquarters:
CASAPPA S.p.A.
Via Balestrieri, 1
43044 Lemignano di Collecchio
Parma (Italy)
Tel. (+39) 0521 30 41 11
Fax (+39) 0521 80 46 00
E-mail: info@casappa.com
www.casappa.com