You are on page 1of 36

MD 01 T A Edition: 01/09.

2019 Replaces: MD 01 T IE

GEAR FLOW
DIVIDERS
Headquarters:
CASAPPA S.p.A.
Via Balestrieri, 1
43044 Lemignano di Collecchio
Parma (Italy)
Tel. (+39) 0521 30 41 11
Fax (+39) 0521 80 46 00
E-mail: info@casappa.com
www.casappa.com
Magnum

INDEX

Section Page

FEATURES.......................................................................................................................................................................... 3

GENERAL DATA.................................................................................................................................................................. 4

FLOW EQUALIZERS............................................................................................................................................................ 6

FLOW DIVIDERS................................................................................................................................................................. 8

PRESSURE INTENSIFIERS................................................................................................................................................. 10

NOTES ABOUT COMPOSITION.......................................................................................................................................... 12

PORTS - POSITION AND TYPE.......................................................................................................................................... 14

FLOW DIVIDERS DIMENSIONS.......................................................................................................................................... 17

TYPICAL CIRCUITS FOR FLOW EQUALIZERS.................................................................................................................... 19

SAE STRAIGHT BSPP THREAD PORT CONNECTORS........................................................................................................ 22

HOW TO ORDER................................................................................................................................................................ 32

01/09.2019

2 DCAT018-ID02
Magnum

FEATURES

Modern machinery with complex kinematics often calls for multiple movements that are separate and fully indepen-
dent of each other. In flow equalization and flow division applications and for high pressure actuation, CASAPPA re-
spond with their comprehensive MAGNUM 30 and MAGNUM 35 range of flow dividing gear motors to transmit fluid
power using rational technical solutions and at low costs. When these rotary flow dividers are used for the correct
applications they permit the optimization of hydraulic circuits and improve pump life, thereby reducing installation
and operating costs. The MAGNUM series of rotary flow dividers comprise two or more independent gear sections
internally connected by a common shaft so that the ratio of the output flow from each section is proportional and
constant to its individual displacement capacity, excluding small losses in volumetric efficiency. Rotary flow dividers
do not dissipate energy. If the outlet pressure from a given section should fall below the inlet pressure then the sec-
tion will act as a motor and absorb energy from the fluid. This energy is not then wasted in the form of heat, instead
it is transferred via the common shaft to the other sections which will continue to pump since their outlet pressure
is higher than their inlet pressure. These components can be used as:

zz
Flow equalizers
zz
Flow dividers
zz
Pressure intensifiers

DISPLACEMENTS zz
Modular design
From 17,28 cm3/rev (1.05 in3/rev)
A 125,63 cm3/rev (7.66 in3/rev)
zz
Accurate division of flow
zz
High flow
PRESSURE
Max. continuous 310 bar (4500 psi) zz
Combination between different groups
Max. peak 335 bar (4800 psi)
01/09.2019

DCAT018-ID02 3
Magnum

GENERAL DATA

Mineral oil based hydraulic fluids to ISO/DIN and fire resistant fluids
Fluid [see table (1)]. For other fluids please consult our technical sales
department.
Fluid temperature range See table (1)
From 12 to 100 mm2/s (cSt) [60 to 456 SSU] recommended
Viscosity range
Up to 750 mm2/s (cSt) [3410 SSU] permitted
Filtering requirement See table (2)

Tab. 1
Temperature °C (°F)
Max pressure Max speed Seals
Type Fluid composition Max. Max.
bar (psi) min-1 Min (u)
continuous peal

Mineral oil based hydraulic -25 (-13) 80 (176) 100 (212) N


ISO/DIN See page 5 See page 5
fluid to ISO/DIN -25 (-13) 110 (230) 125 (257) V
Oil emulsion in water
HFA 50 (725) 1500 2 (36) 55 (131) _ N
5 ÷ 15% of oil
Water emulsion in oil
HFB 120 (1740) 1500 2 (36) 60 (140) _ N
40 % of water
HFC Water - glycol 100 (1450) 1500 -20 (-4) 60 (140) _ N Bz
HFD Phosphate ester 150 (2175) 1500 -10 (14) 80 (176) _ V Bz

(u) N = Buna N (standard) - V= Viton - N Bz= Buna N and Bronze thrust plates - V Bz=Viton and Bronze thrust plates.

O Casappa recommends to use


Tab. 2
its own production filters:
Δp < 2030Δ 2030 < ∆p < 3045 Δp > 3045
Working pressure psi (bar)
Δp < (140) (140) < ∆p < (210) Δp > (210)
Contamination class NAS 1638 10 9 8
Contamination class ISO 4406:1999 21/19/16 20/18/15 19/17/14
Achieved with filter ß10 (c) ≥ 200 according to ISO 16889 - 10 μm 10 μm
Achieved with filter ß25 (c) ≥ 200 according to ISO 16889 25 μm - -
01/09.2019

4 DCAT018-ID02
Magnum

GENERAL DATA

Displacement Max. pressure Max. speed Min. speed


Type p1 p2
cm3/rev (in3/rev) min-1
bar (psi)

HDD 30•17 17,28 (1.05) 310 (4500) 335 (4800) 3000 500

HDD 30•22 21,89 (1.34) 310 (4500) 335 (4800) 3000 500

HDD 30•27 26,58 (1.62) 310 (4500) 335 (4800) 3000 500

HDD 30•34 34,39 (2.10) 310 (4500) 335 (4800) 3000 500

HDD 30•43 43,77 (2.67) 310 (4500) 335 (4800) 3000 500

HDD 30•51 51,59 (3.15) 310 (4500) 335 (4800) 2500 500

HDD 30•61 60,97 (3.72) 310 (4500) 335 (4800) 2500 500

HDD 30•73 73,47 (4.48) 310 (4500) 335 (4800) 2000 500

HDD 30•82 81,29 (4.96) 310 (4500) 335 (4800) 2000 500

HDD 35•50 50,77 (3.10) 310 (4500) 335 (4800) 3000 500

HDD 35•63 63,46 (3.87) 310 (4500) 335 (4800) 3000 500

HDD 35•71 71,92 (4.39) 310 (4500) 335 (4800) 3000 500

HDD 35•80 80,39 (4.90) 310 (4500) 335 (4800) 3000 500

HDD 35•90 90,96 (5.55) 310 (4500) 335 (4800) 2700 500

HDD 35•100 99,43 (6.06) 310 (4500) 335 (4800) 2700 500

HDD 35•112 112,12 (6.84) 310 (4500) 335 (4800) 2700 500

HDD 35•125 124,81(7.61) 310 (4500) 335 (4800) 2500 500

p1= Max. continuous pressure p2= Max. peak pressure

Note: Diagrams providing selection data will be found on subsequent pages.


01/09.2019

DCAT018-ID02 5
Magnum

FLOW EQUALIZERS

Flow dividing gear motors are suited for applications where the flow must be divided equally with maximum actua-
tor synchronization difference of ± 2 %. In order to obtain synchronous operation the displacements of the gear
sections must be identical. When several single acting cylinders are operated together, acting on loads have not
sufficient mass to win the circuit’s resistance, we recommend the flow equalizer must be supplemented by a further
gear section acting as a motor in order to guarantee the cylinders retract. The displacement of this motor section
can be in the same group as the sections of the equalizer or of a different group, but it should be roughly equal to the
sum of the displacements of the other sections. Two typical circuit diagrams of applications where flow equalizers
are utilized will be found on page 19.

V cm3/rev (in3/rev) Displacement

Q l/min (US gpm) Delivery

p bar (psi) Pressure


p1Q1 p2Q2 pnQn n min-1 Speed

V1 V2 Vn
V1 = V2 .... = Vn
p0Q0
Q0 = Q1 + Q2 .... + Qn

p0Q0 = p1Q1 + p2Q2 .... + pnQn


D018-D07/1212

V0

Let us assume that it is necessary to supply power to two services that require a flow rate of 100 l/min (26.42 US
gpm) each. For simplicity’s sake we will ignore pressure losses and the compression factor of the fluid. The pump
must deliver a flow equal to: Q0 = Q1 + Q2 = 200 l/min (52.84 US gpm). To find the displacement of the two sections
of the flow equalizer, assuming group HDD 30 is to be used, simply locate the flow rate 200 l/min (52.84 US gpm) on
the X axis and then ascend vertically until the line corresponding to the number of sections (2) is encountered; now
trace a horizontal line to the right until encountering the lines referring to displacement. Select the displacement with
the point of intersection on the graph that lies nearest to the maximum speed for the optimum performance range.

01/09.2019

6 DCAT018-ID02
Magnum

FLOW EQUALIZERS

2
3 170

Q [l/min] - [(US gpm)]

82
(44.9)

61
73
150
(39.6)

51

43
4
120
(31.7)

5 34
HDD 30

90
6 (23.8)
27

22
NUMERO DI SEZIONI
Number of sections

60
(15.9) 17

30
(7.9)
DIAG018-001

500 400 300 200 100 0 500 1000 1500 2000 2500 3000
(132.1) (105.7) (79.3) (52.8) (26.4)

Q [l/min] - [(US gpm)] n [min-1]

2
320
Q [l/min] - [(US gpm)]

(84.5)

125

2
11
280

0
10
3 (74.0)

240 90
(63.4) 80

4 71
200
(52.8)
63
HDD 35

5 160
(42.3) 50
6
NUMERO DI SEZIONI
Number of sections

120
01/09.2019

(31.7)

80
(21.1)
DIAG018-002

40
(10.6)

800 600 400 200 0 500 1000 1500 2000 2500 3000
(211.4) (158.5) (105.7) (52.8)

Q [l/min] - [(US gpm)] n [min-1]

Each curve has been obtained at 50°C (122 °F), using oil with
Range for optimum performance viscosity 36 cSt (168 SSU) at 40°C (104 °F).

DCAT018-ID02 7
Magnum

FLOW DIVIDERS

These flow dividers are used where the same pump must drive several different services requiring different pressu-
res and flow rates. The displacement of each section must be proportional to the flow rate required by the service to
which it is connected. Two typical circuits in which flow dividers are installed will be found on page 20.

V cm3/rev (in3/rev) Displacement

Q l/min (US gpm) Delivery

p bar (psi) Pressure


p1Q1 p2Q2 pnQn
n min-1 Speed

V1 V2 Vn
Q0 = Q1 + Q2 .... + Qn
p0Q0

p0Q0 = p1Q1 + p2Q2 .... + pnQn


D018-D08/1212

1000 Q
V =
V0 n

Assume two services must be driven absorbing 100 l/min (26.42 US gpm) and 65 l/min (17.17 US gpm) respectively.
To find the displacement of the flow divider sections, assuming the HDD 30 group is opted for, simply locate the flow
rates in question on the Y axis and then move across horizontally until the lines corresponding to the displacement
are encountered. Select a displacement with points of intersection aligned as near as possible vertically, and the
nearest to the maximum speed for the optimum performance range.

01/09.2019

8 DCAT018-ID02
Magnum

FLOW DIVIDERS

170

Q [l/min] - [(US gpm)]


(44.9)

82

61
150

73
(39.6)

51

43
PORTATA PER SEZIONE
120

Flow for each section


(31.7)

34
90
(23.8)
HDD 30

27

60
22
(15.9)
17

30
(7.9)
DIAG018-003

0
0 500 1000 1500 2000 2500 3000

n [min-1]

320
Q [l/min] - [(US gpm)]

(84.5)
125

2
11

280
(74.0)
0
10
90

240
(63.4)
PORTATA PER SEZIONE

80
Flow for each section

200 71
(52.8)
63
160
HDD 35

(42.3)
50

120
(31.7)
01/09.2019

80
(21.1)

40
DIAG018-004

(10.6)

0
0 500 1000 1500 2000 2500 3000

n [min-1]

Each curve has been obtained at 50°C (122 °F), using oil with
Range for optimum performance viscosity 36 cSt (168 SSU) at 40°C (104 °F).

DCAT018-ID02 9
Magnum

PRESSURE INTENSIFIERS

Pressure intensifiers are used for services requiring working pressures in excess of the operating pressure of the
pump. Pressure is increased by using one of two sections as a motor connecting it to “tank” and the other as a
pump connecting it to the service. For optimum intensification, the ratio R between the displacement of the “motor”
and “pump” sections must fall within the range 0.5 ÷ 2. The graph on page 11 illustrates pressure intensification
available with these units. Two typical circuit diagrams incorporating pressure intensifiers are shown on page 21.

V cm3/rev (in3/rev) Displacement


p1Q1 p2Q2
Q l/min (US gpm) Delivery

p bar (psi) Pressure


V1 V2 n min-1 Speed

p0Q0

Q0 = Q1 + Q2
D018-D09/1212

p0Q0 = p1Q1 + p2Q2


V0
1000 Q
V =
n

Let us imagine that we must drive a service at a pressure of 300 bar (4350 psi) with a flow of 100 l/min (26.42 US
gpm). To find the working pressure of the main pump use graph on the facing page. First locate the pressure requi-
red by the service on the X axis and then move up vertically until the lines of ratio R. Select the displacement ratio
between the two intensifier sections R=1 and move horizontally to the left to read off the pressure value on the Y
axis p0 = 180 bar (2610 psi). Remember that R = V2 / V1 = 1

Q1 = Q2 = 100 l/min (26.42 US gpm)

Select section displacements by consulting the graphs on pages 7 to 9.

01/09.2019

10 DCAT018-ID02
Magnum

PRESSURE INTENSIFIERS

200
(2900)
[bar] - [(psi)]
180
(2610)

160
0.5
(2320) R=
PRESSIONE DI INGRESSO

140
(2030)
1
R=
Inlet pressure

120
(1740)

R=2
100
(1450)

80
(1160)

60
(870)

40
(580)
DIAG018-005

20
(290)

0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340
(290) (580) (870) (1160) (1450) (1740) (2030) (2320) (2610) (2900) (3190) (3480) (3770) (4060) (4350) (4640) (4930)

PRESSIONE INTENSIFICATA
Intensified pressure [bar] - [(psi)]

Each curve has been obtained at 50°C (122 °F), using oil with viscosity 36 cSt (168 SSU) at 40°C (104 °F).
01/09.2019

DCAT018-ID02 11
Magnum

NOTES ABOUT COMPOSITION

Flow divider sections are arranged in descending displacements or groups with the largest displacement to the left
as viewed from the delivery ports side. Where flow dividers are made up of different groups, an intermediate inlet
section must be disposed between them. Standard formats of flow dividers are given beneath and on the following
pages; for different configurations please consult our Technical Sales staff.

INTERMEDIATE INLET SECTIONS

Group HDD 30 HDD 35

HDD 30 C 30 • 30 ____

HDD 35 C 35 • 30 C 35 • 35

STANDARD COMPOSITION

2 SECTIONS
Max. delivery for inlet section
Type

l/min (US gpm)


D018-D10/1212

C 30 • 30 350 (92.5)

C 35 • 30 550 (145.3)

C 35 • 35 550 (145.3)

3 SECTIONS
D018-D11/1212

01/09.2019
D018-D12/1212

12 DCAT018-ID02
Magnum

STANDARD COMPOSITION

4 SECTIONS
Max. delivery for inlet section
Type

l/min (US gpm)


D018-D13/1212

C 30 • 30 350 (92.5)

C 35 • 30 550 (145.3)

C 35 • 35 550 (145.3)
D018-D14/1212

5 SECTIONS
D018-D15/1212

6 SECTIONS
D018-D16/1212
01/09.2019

STANDARD COMPOSITION FOR FLOW EQUALIZERS WITH MOTOR SECTION

INTERMEDIATE FLANGE
F Group HDD 30 HDD 35
D018-D24/1212

HDD 30 F 30 • 30 ____

HDD 35 F 35 • 30 F 35 • 35
MAX. 6 SECTIONS

DCAT018-ID02 13
Magnum

D018-D12/1212 PORTS - POSITION AND TYPE

D018-D24/1212
Flow equalizer with motor section.

Standard version

PORTS SSS SSM BSPP ODT


Type IN IN OUT IN IN OUT IN IN OUT IN IN OUT

HDD 30•17 SD SB SB MD MB MB GF GE GD OF OD OB

HDD 30•22 SD SB SB MD MB MB GF GE GD OF OD OB

HDD 30•27 SD SC SB MD MC MB GF GF GE OF OF OD

HDD 30•34 SD SC SB MD MC MB GF GF GE OF OF OD

HDD 30•43 SD SD SC MD MD MC GF GG GF OF OG OF

HDD 30•51 SD SD SC MD MD MC GF GG GF OF OG OF

HDD 30•61 SD SE SD MD ME MD GF GG GF OF OG OF

HDD 30•73 SD SE SD MD ME MD GF GG GF OF OG OF

HDD 30•82 SD SE SD MD ME MD GF GG GF OF OG OF

HDD 35•50 SE SE SD ME ME MD GH GH GG OH OG OF

HDD 35•63 SE SE SD ME ME MD GH GH GG OH OG OF

HDD 35•71 SE SE SD ME ME MD GH GH GG OH OG OF
01/09.2019

HDD 35•80 SE SE SD ME ME MD GH GH GG OH OG OF

HDD 35•90 SE SF SE ME MF ME GH GL GH OH OH OG

HDD 35•100 SE SF SE ME MF ME GH GL GH OH OH OG

HDD 35•112 SE SF SE ME MF ME GH GL GH OH OH OG

HDD 35•125 SE SF SE ME MF ME GH GL GH OH OH OG

14 DCAT018-ID02
Magnum

PORT SIZES

Port tightening torque [values obtained at 350 bar (5075 psi)]

SAE FLANGED PORTS J518 - Standard pressure series 3000 PSI SSS
American straight thread UNC-UNF 60° conforms to ANSI B 1.1

A B C D
CODE
mm mm mm Thread Nm
(in) (in) (in) Depth mm (in) (lbf in)
19 47,6 22,2 3/8 - 16 UNC-2B 30 +2,5
SB (0.75) (1.87) (0.87) 22 (0.87) (266 ÷ 288)

D010-D15/1212
25,4 52,4 26,2 3/8 - 16 UNC-2B 30 +2,5
SC (1.00) (2.06) (1.03) 22 (0.87) (266 ÷ 288)
30,5 58,7 30,2 7/16 - 14 UNC-2B 55 +5
SD (1.20) (2.31) (1.19) 28,5 (1.12) (487 ÷ 531)
39,3 69,8 35,7 1/2 - 13 UNC-2B 70 +5
SE (1.55) (2.75) (1.40) 27 (1.06) (620 ÷ 664)
51 77,8 42,9 1/2 - 13 UNC-2B 90 +5
SF (2.00) (3.06) (1.69) 27 (1.06) (797 ÷ 841)

SAE FLANGED PORTS J518 - Standard pressure series 3000 PSI SSM
Metric thread ISO 60° conforms to ISO/R 262

A B C D
CODE
mm mm mm Thread Nm
(in) (in) (in) Depth mm (in) (lbf in)
19 47,6 22,2 M 10 35 +2,5
MB (0.75) (1.87) (0.87) 22 (0.87) (310 ÷ 332)
D010-D15/1212

25,4 52,4 26,2 M 10 35 +2,5


MC (1.00) (2.06) (1.03) 22 (0.87) (310 ÷ 332)
30,5 58,7 30,2 M 10 35 +2,5
MD (1.20) (2.31) (1.19) 22 (0.87) (310 ÷ 332)
01/09.2019

39,3 69,8 35,7 M 12 65 +5


ME (1.55) (2.75) (1.41) 27 (1.06) (575 ÷ 620)
51 77,8 42,9 M 12 90 +5
MF (2.00) (3.06) (1.69) 27 (1.06) (797 ÷ 841)

DCAT018-ID02 15
Magnum

PORT SIZES

Port tightening torque [values obtained at 350 bar (5075 psi)]

GAS STRAIGHT THREAD PORTS BSPP


British standard pipe parallel (55°) conforms to UNI - ISO 228

Nominal
B C
CODE
size
A
mm mm Nm
(in) (in) (lbf in)

D010-D16/1212
18 19 50 +2,5
GD 1/2” G 1/2
(0.71) (0.75) (443 ÷ 465)
20 24,5 90 +5
GE 3/4” G 3/4
(0.79) (0.96) (797 ÷ 841)
22 30,5 130 +10
GF 1” G1
(0.87) (1.20) (1151 ÷ 1239)
24 39,3 170 +15
GG 1” 1/4 G 1 1/4
(0.94) (1.55) (1505 ÷ 1637)
26 45 210 +15
GH 1” 1/2 G 1 1/2
(1.02) (1.77) (1859 ÷ 1991)
32 56 400 +20
GL 2” G2
(1.26) (2.20) (3540 ÷ 3717)

SAE STRAIGHT THREAD PORTS J514 ODT


American straight thread UNC-UNF 60° conforms to ANSI B 1.1
D010-D17/1212

Nominal
B C D E
CODE
size
A
mm mm mm mm Nm
(in) (in) (in) (in) (lbf in)
01/09.2019

15 32 0,5 2,5 45 +2,5


OB 1/2” 3/4 - 16 UNF - 2B
(0.59) (1.26) (0.02) (0.10) (398 ÷ 420)
20 42 0,5 3,3 120 +10
OD 3/4” 1 1/16” - 12 UNF - 2B
(0.79) (1.65) (0.02) (0.13) (1062 ÷ 1151)
20 50 0,5 3,3 170 +10
OF 1” 1 5/16” - 12 UNF - 2B
(0.79) (1.97) (0.02) (0.13) (1505 ÷ 1593)
20 60 0,5 3,3 200 +10
OG 1” 1/4 1 5/8” - 12 UNF - 2B
(0.79) (2.36) (0.02) (0.13) (1770 ÷ 1859)
20 70 0,5 3,3 270 +15
OH 1” 1/2 1 7/8” - 12 UNF - 2B
(0.79) (2.76) (0.02) (0.13) (2390 ÷ 2523)

16 DCAT018-ID02
Magnum

FLOW DIVIDERS DIMENSIONS - SAME GROUP

26 26
[1.0236] [1.0236]
D018-D01/1212

Ø 13
[0.5118]
70 Elemento terminale Collettore Elemento intermedio Elemento terminale
[2.7559] End section Inlet section Intermediate section End section

A B C D E F G H
Flow divider type mm mm mm mm mm mm mm mm
(in) (in) (in) (in) (in) (in) (in) (in)
155 57 70 + E 77 70 75 110
HDD 30 + HDD 30 (6.10) (2.24) (2.76 + E) (3.03)
See below
(2.76) (2.95) (4.33)
175 63 82 + E 93 82 87,5 135
HDD 35 + HDD 35 (6.89) (2.48) (3.23 + E) (3.66)
See below
(3.23) (3.44) (5.32)

E E
Flow divider type mm Flow divider type mm
(in) (in)
23 38
HDD 30•17 (0.91)
HDD 35•50 (1.50)
26 44
HDD 30•22 (1.02)
HDD 35•63 (1.73)
29 48
HDD 30•27 (1.14)
HDD 35•71 (1.89)
34 52
HDD 30•34 (1.34)
HDD 35•80 (2.05)
01/09.2019

40 57
HDD 30•43 (1.57)
HDD 35•90 (2.24)
45 61
HDD 30•51 (1.77)
HDD 35•100 (2.40)
51 67
HDD 30•61 (2.01)
HDD 35•112 (2.64)
59 73
HDD 30•73 (2.32)
HDD 35•125 (2.87)
64
HDD 30•82 (2.52)

DCAT018-ID02 17
Magnum

FLOW DIVIDERS DIMENSIONS - DIFFERENT GROUP

175
[6.8898]
155 26 63 57 26
[6.1024] [1.0236] [2.4803] [2.2441] [1.0236]

[3.4449]
87,5
[5.3150]
135

82 70
[3.2283] [2.7559]
[1.1378]
D018-D02/1212

28,9

Ø 13 93 77
[0.5118] [3.6614] [3.0315]
70 Elemento terminale Collettore Elemento intermedio Elemento terminale
[2.7559] End section Inlet section Intermediate section End section

A B C
Flow divider type mm mm mm
(in) (in) (in)
82 + D 76 + E 70 + E
HDD 35 + HDD 30 (3.23 + D) (2.99 + E) (2.76 + E)

E E
Flow divider type mm Flow divider type mm
(in) (in)
23 23
HDD 35•50 (0.91)
HDD 30•17 (0.91)
26 26
HDD 30•22 (1.02)
HDD 30•22 (1.02)
29 29
HDD 30•27 (1.14)
HDD 30•27 (1.14)
34 34
HDD 30•34 (1.34)
HDD 30•34 (1.34)
01/09.2019

40 40
HDD 30•43 (1.57)
HDD 30•43 (1.57)
45 45
HDD 30•51 (1.77)
HDD 30•51 (1.77)
51 51
HDD 30•61 (2.01)
HDD 30•61 (2.01)
59 59
HDD 30•73 (2.32)
HDD 30•73 (2.32)
64 64
HDD 30•82 (2.52)
HDD 30•82 (2.52)

18 DCAT018-ID02
Magnum

TYPICAL CIRCUITS FOR FLOW EQUALIZERS


01/09.2019

Diagram with a flow divider permitting the use of a single pump Diagram with a flow divider permitting the use of a single pump
to drive a number of different services requiring flows at diffe- to drive a number of different services requiring flows at diffe-
rent pressures. rent pressures.

DCAT018-ID02 19
Magnum

TYPICAL CIRCUITS FOR FLOW DIVIDERS

01/09.2019

Diagram with a flow divider permitting the use of a single Diagram with a flow divider permitting the use of a single
pump to drive a number of different services requiring flows at pump to drive a number of different services requiring flows at
different pressures. different pressures.

20 DCAT018-ID02
Magnum

TYPICAL CIRCUITS FOR PRESSURE INTENSIFIERS


01/09.2019

Diagram with pressure intensifier so that a service requiring a Diagram with pressure intensifier so that a service requiring a
pressure higher than the pressure available at the main delivery pressure higher than the pressure available at the main delivery
pump can be driven. pump can be driven.

DCAT018-ID02 21
Magnum

SAE STRAIGHT BSPP THREAD PORT CONNECTORS

D018-D25/1212

A B C D E F G H I
Type
mm mm mm mm mm mm mm mm
Screws O-ring
(in) (in) (in) (in) (in) (in) (in) (in)
13 19 16 36 54 38,1 17,5 46 M8
RD2-MA/FG12-N G 1/2 4075
(0.51) (0.75) (0.63) (1.42) (2.13) (1.50) (0.69) (1.81) UNI 5931-8.8
13 19 16 36 54 38,1 17,5 46 M8
RD2-MA/FG38-N G 3/8 4075
(0.51) (0.75) (0.63) (1.42) (2.13) (1.50) (0.69) (1.81) UNI 5931-8.8
19 19 18 36 65 47,6 22,2 50 M 10
RD2-MB/FG34-N G 3/4 4100
(0.75) (0.75) (0.71) (1.42) (2.56) (1.87) (0.87) (1.97) UNI 5931-8.8
13 19 18 36 65 47,6 22,2 50 M 10
RD2-MB/FG12-N G 1/2 4100
(0.51) (0.75) (0.71 (1.42) (2.56) (1.87) (0.87) (1.97) UNI 5931-8.8
25 19 18 38 70 52,4 26,2 52 M 10
RD2-MC/FG100-N G1 4131
(0.98) (0.75) (0.71) (1.50) (2.76) (1.06) (1.03) (2.05) UNI 5931-8.8
19 19 18 38 70 52,4 26,2 52 M 10
RD2-MC/FG34-N G 3/4 4131
(0.75) (0.75) (0.71) (1.50) (2.76) (1.06) (1.03) (2.05) UNI 5931-8.8
32 22 21 41 79 58,7 30,2 68 M 10
RD2-MD/FG114-N G 1 1/4 4150
(1.26) (0.87) (0.83) (1.61) (3.11) (2.31) (1.19) (2.68) UNI 593-12.9
25 22 21 41 79 58,7 30,2 68 M 10
RD2-MD/FG100-N G1 4150
(0.98) (0.87) (0.83) (1.61) (3.11) (2.31) (1.19) (2.68) UNI 593-12.9
38 24 25 44 93 69,8 35,7 78 M 12
RD2-ME/FG112-N G 1 1/2 4187
(1.50) (0.94) (0.98) (1.73) (3.66) (2.75) (1.41) (3.07) UNI 593-12.9
32 24 25 44 93 69,8 35,7 78 M 12
RD2-ME/FG114-N G 1 1/4 4187
(1.26) (0.94) (0.98) (1.73) (3.66) (2.75) (1.41) (3.07) UNI 593-12.9
51 30 25 45 102 77,8 42,9 90 M 12
RD2-MF/FG200-N G2 4225
(2.01) (1.18) (0.98) (1.77) (4.02) (3.06) (1.69) (3.54) UNI 593-12.9
38 26 25 45 102 77,8 42,9 90 M 12
RD2-MF/FG112-N G 1 1/2 4225
(1.50) (1.02) (0.98) (1.77) (4.02) (3.06) (1.69) (3.54) UNI 593-12.9
01/09.2019

22 DCAT018-ID02
Magnum

SAE STRAIGHT BSPP THREAD PORT CONNECTORS

A B C D E F G H I
Type Screws O-ring
mm mm mm mm mm mm mm mm
(in) (in) (in) (in) (in) (in) (in) (in)
13 19 16 36 54 38,1 17,5 46 5/16
RD2-SA/FG12-N G 1/2 4075
(0.51) (0.75) (0.63) (1.42) (2.13) (1.50) (0.69) (1.81) -18 UNC-2B
13 19 16 36 54 38,1 17,5 46 5/16
RD2-SA/FG38-N G 3/8 4075
(0.51) (0.75) (0.63) (1.42) (2.13 (1.50) (0.69) (1.81) -18 UNC-2B
19 19 18 36 65 47,6 22,2 50 3/8
RD2-SB/FG34-N G 3/4 4100
(0.75) (0.75) (0.71) (1.42) (2.56) (1.87) (0.87) (1.97) -16 UNC-2B
13 19 18 36 65 47,6 22,2 50 3/8
RD2-SB/FG12-N G 1/2 4100
(0.51) (0.75) (0.71) (1.42) (2.56) (1.87) (0.87) (1.97) -16 UNC-2B
25 19 18 38 70 52,4 26,2 52 3/8
RD2-SC/FG100-N G1 4131
(0.98) (0.75) (0.71) (1.50) (2.76) (2.06) (1.03) (2.05) -16 UNC-2B
19 19 18 38 70 52,4 26,2 52 3/8
RD2-SC/FG34-N G 3/4 4131
(0.75) (0.7) (0.71) (1.50) (2.76) (2.06) (1.03) (2.05) -16 UNC-2B
32 22 21 41 79 58,7 30,2 68 7/16
RD2-SD/FG114-N G 1 1/4 4150
(1.26) (0.87) (0.83) (1.61) (3.11) (2.31) (1.19) (2.68) -14 UNC-2B
25 22 21 41 79 58,7 30,2 68 7/16
RD2-SD/FG100-N G1 4150
(0.98) (0.87) (0.83) (1.61) (3.11) (2.31) (1.19) (2.68) -14 UNC-2B
38 24 25 44 93 69,8 35,7 78 1/2
RD2-SE/FG112-N G 1 1/2 4187
(1.50) (0.94) (0.98) (1.73) (3.66) (2.75) (1.41) (3.07) -14 UNC-2B
32 24 25 44 93 69,8 35,7 78 1/2
RD2-SE/FG114-N G 1 1/4 4187
(1.26) (0.94) (0.98) (1.73) (3.66) (2.75) (1.41) (3.07) -14 UNC-2B
51 30 25 45 102 77,8 42,9 90 1/2
RD2-SF/FG200-N G2 4225
(2.01) (1.18) (0.98) (1.77) (4.02) (3.06) (1.69) (3.54) -14 UNC-2B
38 26 25 45 102 77,8 42,9 90 1/2
RD2-SF/FG112-N G 1 1/2 4225
(1.50) (1.02) (0.98) (1.77) (4.02) (3.06) (1.69) (3.54) -14 UNC-2B

Standard port connectors are equipped with BUNA seals. For heavier operating conditions, require it with VITON seals repla-
ceing code’s last letter N with the V letter. (eg. RD2-MA/FG12-N - RD2-MA/FG12-V).
Note: Torque values in the table refer to the mounting of port connectors on MAGNUM series.
01/09.2019

DCAT018-ID02 23
Magnum

SAE STRAIGHT NPT THREAD PORT CONNECTORS

D018-D25/1212

A B C D E F G H I
Type Screws O-ring
mm mm mm mm mm mm mm mm
(in) (in) (in) (in) (in) (in) (in) (in)
13 19 16 36 54 38,1 17,5 46 M8
RD2-MA/FN12-N 1/2 NPT
(0.51) (0.75) (0.63) (1.42) (2.13) (1.50) (0.69) (1.81) UNI 5931-8.8
4075
13 19 16 36 54 38,1 17,5 46 M8
RD2-MA/FN38-N 3/8 NPT
(0.51) (0.75) (0.63) (1.42) (2.13) (1.50) (0.69) (1.81) UNI 5931-8.8
4075
19 19 18 36 65 47,6 22,2 50 M 10
RD2-MB/FN34-N 3/4 NPT
(0.75) (0.75) (0.71) (1.42) (2.56) (1.87) (0.87) (1.97) UNI 5931-8.8
4100
13 19 18 36 65 47,6 22,2 50 M 10
RD2-MB/FN12-N 1/2 NPT
(0.51) (0.75) (0.71) (1.42) (2.56) (1.87) (0.87) (1.97) UNI 5931-8.8
4100

25 19 18 38 70 52,4 26,2 52 M 10
RD2-MC/FN100-N 1 NPT
(0.98) (0.75) (0.71) (1.50) (2.76) (2.06) (1.03) (2.05) UNI 5931-8.8
4131

19 19 18 38 70 52,4 26,2 52 M 10
RD2-MC/FN34-N 3/4 NPT
(0.75) (0.75) (0.71) (1.50) (2.76) (2.06) (1.03) (2.05) UNI 5931-8.8
4131
32 22 21 41 79 58,7 30,2 68 M 10
RD2-MD/FN114-N 1 1/4 NPT
(1.26) (0.87) (0.83) (1.61) (3.11) (2.31) (1.19) (2.68) UNI 593-12.9
4150

25 22 21 41 79 58,7 30,2 68 M 10
RD2-MD/FN100-N 1 NPT 4150
(0.98) (0.87) (0.83) (1.61) (3.11) (2.31) (1.19) (2.68) UNI 593-12.9
38 24 25 44 93 69,8 35,7 78 M 12
RD2-ME/FN112-N 1 1/2 NPT
(1.50) (0.94) (0.98) (1.73) (3.66) (2.75) (1.41) (3.07) UNI 593-12.9
4187
32 24 25 44 93 69,8 35,7 78 M 12
RD2-ME/FN114-N 1 1/4 NPT
(1.26) (0.94) (0.98) (1.73) (3.66) (2.75) (1.41) (3.07) UNI 593-12.9
4187
51 30 25 45 102 77,8 42,9 90 M 12
RD2-MF/FN200-N 2 NPT
(2.01) (1.18) (0.98) (1.77) (4.02) (3.063) (1.69) (3.54) UNI 593-12.9
4225
38 26 25 45 102 77,8 42,9 90 M 12
RD2-MF/FN112-N 1 1/2 NPT
(1.50) (1.02) (0.98) (1.77) (4.02) (3.06) (1.69) (3.54) UNI 593-12.9
4225

01/09.2019

24 DCAT018-ID02
Magnum

SAE STRAIGHT NPT THREAD PORT CONNECTORS

A B C D E F G H I
Type Screws O-ring
mm mm mm mm mm mm mm mm
(in) (in) (in) (in) (in) (in) (in) (in)
13 19 16 36 54 38,1 17,5 46 5/16
RD2-SA/FN12-N 1/2 NPT 4075
(0.51) (0.75) (0.63) (1.42) (2.13) (1.50) (0.69) (1.81) -18 UNC-2B
13 19 16 36 54 38,1 17,5 46 5/16
RD2-SA/FN38-N 3/8 NPT 4075
(0.51) (0.75) (0.63) (1.42) (2.13) (1.50) (0.69) (1.81) -18 UNC-2B
19 19 18 36 65 47,6 22,2 50 3/8
RD2-SB/FN34-N 3/4 NPT 4100
(0.75) (0.75) (0.71) (1.42) (2.56) (1.87) (0.87) (1.967) -16 UNC-2B
13 19 18 36 65 47,6 22,2 50 3/8
RD2-SB/FN12-N 1/2 NPT 4100
(0.5118) (0.75) (0.71) (1.42) (2.56) (1.87) (0.87) (1.97) -16 UNC-2B
25 19 18 38 70 52,4 26,2 52 3/8
RD2-SC/FN100-N 1 NPT 4131
(0.98) (0.75) (0.71) (1.50) (2.76) (2.06) (1.03) (2.05) -16 UNC-2B
19 19 18 38 70 52,4 26,2 52 3/8
RD2-SC/FN34-N 3/4 NPT 4131
(0.75) (0.75) (0.71) (1.50) (2.76) (2.06) (1.03) (2.05) -16 UNC-2B
1 1/4 32 22 21 41 79 58,7 30,2 68 7/16
RD2-SD/FN114-N 4150
NPT (1.26) (0.87) (0.83) (1.61) (3.11) (2.31) (1.19) (2.68) -14 UNC-2B
25 22 21 41 79 58,7 30,2 68 7/16
RD2-SD/FN100-N 1 NPT 4150
(0.98) (0.87) (0.83) (1.61) (3.11) (2.31) (1.19) (2.68) -14 UNC-2B
1 1/2 38 24 25 44 93 69,8 35,7 78 1/2
RD2-SE/FN112-N 4187
NPT (1.50) (0.94) (0.98) (1.73) (3.66) (2.75) (1.41) (3.07) -14 UNC-2B
1 1/4 32 24 25 44 93 69,8 35,7 78 1/2
RD2-SE/FN114-N 4187
NPT (1.26) (0.94) (0.98) (1.73) (3.66) (2.75) (1.41) (3.07) -14 UNC-2B
51 30 25 45 102 77,8 42,9 90 1/2
RD2-SF/FN200-N 2 NPT 4225
(2.01) (1.18) (0.98) (1.77) (4.02) (3.06) (1.69) (3.543) -14 UNC-2B
1 1/2 38 26 25 45 102 77,8 42,9 90 1/2
RD2-SF/FN112-N 4225
NPT (1.50) (1.02) (0.98) (1.77) (4.02) (3.06) (1.69) (3.54) -14 UNC-2B

Standard port connectors are equipped with BUNA seals. For heavier operating conditions, require it with VITON seals repla-
ceing code’s last letter N with the V letter (eg. RD2-MA/FN12-N - RD2-MA/FN12-V).
Note: Torque values in the table refer to the mounting of port connectors on MAGNUM series.
01/09.2019

DCAT018-ID02 25
Magnum

SAE STRAIGHT WELD IN PORT CONNECTORS

D018-D27/1212

A B C D E F G H I
Nom.
Type
size
Screws O-ring
mm mm mm mm mm mm mm mm
(in) (in) (in) (in) (in) (in) (in) (in)
21,6 13 19 16 36 54 38,1 17,5 46 M8
RD2-MA/S12-N 1/2”
(0.85) (0.51) (0.75) (0.63) (1.42) (2.13) (1.50) (0.69) (1.81) UNI 5931-8.8
4075

17,5 13 19 16 36 54 38,1 17,5 46 M8


RD2-MA/S38-N 3/8”
(0.69) (0.51) (0.75) (0.63) (1.42) (2.13) (1.50) (0.69) (1.81) UNI 5931-8.8
4075

27,2 19 19 18 36 65 47,6 22,2 50 M 10


RD2-MB/S34-N 3/4”
(1.07) (0.75) (0.75) (0.71) (1.42) (2.56) (1.87) (0.87) (1.97) UNI 5931-8.8
4100

34 25 19 18 38 70 52,4 26,2 52 M 10
RD2-MC/S100-N 1”
(1.34) (0.98) (0.75) (0.71) (1.50) (2.76) (2.06) (1.03) (2.05) UNI 5931-8.8
4131

42,8 32 22 21 41 79 58,7 30,2 68 M 10


RD2-MD/S114-N 1” 1/4
(1.69) (1.26) (0.87) (0.83) (1.61) (3.11) (2.31) (1.19) (2.68) UNI 593-12.9
4150

48,6 38 24 25 44 93 69,8 35,7 78 M 12


RD2-ME/S112-N 1” 1/2
(1.91) (1.50) (0.94) (0.98) (1.73) (3.66) (2.75) (1.41) (3.07) UNI 593-12.9
4187

61 51 26 25 45 102 77,8 42,9 90 M 12


RD2-MF/S200-N 2”
(2.40) (2.01) (1.02) (0.98) (1.77) (4.02) (3.06) (1.69) (3.54) UNI 593-12.9
4225

A B C D E F G H I
Nom.
Type
size
Screws O-ring
mm mm mm mm mm mm mm mm
(in) (in) (in) (in) (in) (in) (in) (in)
21,6 13 19 16 36 54 38,1 17,5 46 5/16
RD2-SA/S12-N 1/2”
(0.85) (0.51) (0.75) (0.63) (1.42) (2.13) (1.50) (0.69) (1.81) -18 UNC-2B
4075

17,5 13 19 16 36 54 38,1 17,5 46 5/16


RD2-SA/S38-N 3/8”
(0.69) (0.51) (0.75) (0.63) (1.42) (2.13) (1.50) (0.69) (1.81) -18 UNC-2B
4075

27,2 19 19 18 36 65 47,6 22,2 50 3/8


RD2-SB/S34-N 3/4”
(1.07) (0.75) (0.75) (0.71) (1.42) (2.56) (1.87) (0.87) (1.97) -16 UNC-2B
4100

34 25 19 18 38 70 52,4 26,2 52 3/8


RD2-SC/S100-N 1”
(1.34) (0.98) (0.75) (0.71) (1.50) (2.76) (2.06) (1.03) (2.05) -16 UNC-2B
4131

42,8 32 22 21 41 79 58,7 30,2 68 7/16


RD2-SD/S114-N 1” 1/4 4150
01/09.2019

(1.69) (1.26) (0.87) (0.83) (1.61) (3.11) (2.31) (1.19) (2.68) -14 UNC-2B
48,6 38 24 25 44 93 69,8 35,7 78 1/2
RD2-SE/S112-N 1” 1/2
(1.91) (1.50) (0.94) (0.98) (1.73) (3.66) (2.75) (1.41) (3.07) -14 UNC-2B
4187

61 51 26 25 45 102 77,8 42,9 90 1/2


RD2-SF/S200-N 2”
(2.40) (2.01) (1.02) (0.98) (1.77) (4.02) (3.06) (1.69) (3.54) -14 UNC-2B
4225

Standard port connectors are equipped with BUNA seals. For heavier operating conditions, require it with VITON seals repla-
ceing code’s last letter N with the V letter (eg. RD2-MA/S12-N - RD2-MA/S12-V).
Note: Torque values in the table refer to the mounting of port connectors on MAGNUM series.

26 DCAT018-ID02
Magnum

SAE STRAIGHT WELD ON PORT CONNECTORS

D018-D28/1212

A B C D E F G H
Nom.
Type
size
Screws O-ring
mm mm mm mm mm mm mm
(in) (in) (in) (in) (in) (in) (in)
21,6 13 16 36 54 38,1 17,5 46 M8
RD2-MA/T12-N 1/2” 4075
(0.85) (0.51) (0.63) (1.42) (2.13) (1.50) (0.69) (1.81) UNI 5931-8.8
17,5 13 16 36 54 38,1 17,5 46 M8
RD2-MA/T38-N 3/8” 4075
(0.69) (0.51) (0.63) (1.42) (2.13) (1.50) (0.69) (1.81) UNI 5931-8.8
27,2 19 18 36 65 47,6 22,2 50 M 10
RD2-MB/T34-N 3/4” 4100
(1.07) (0.75) (0.71) (1.42) (2.56) (1.87) (0.87) (1.97) UNI 5931-8.8
34 25 18 38 70 52,4 26,2 52 M 10
RD2-MC/T100-N 1” 4131
(1.34) (0.98) (0.71) (1.50) (2.76) (2.06) (1.03) (2.05) UNI 5931-8.8
42,8 32 21 41 79 58,7 30,2 68 M 10
RD2-MD/T114-N 1” 1/4 4150
(1.69) (1.26) (0.83) (1.61) (3.11) (2.31) (1.19) (2.68) UNI 593-12.9
48,6 38 25 44 93 69,8 35,7 78 M 12
RD2-ME/T112-N 1” 1/2 4187
(1.91) (1.50) (0.98) (1.73) (3.66) (2.75) (1.41) (3.07) UNI 593-12.9
61 51 25 45 102 77,8 42,9 90 M 12
RD2-MF/T200-N 2” 4225
(2.40) (2.01) (0.98) (1.77) (4.02) (3.06) (1.69) (3.54) UNI 593-12.9

A B C D E F G H
Nom.
Type
size
Screws O-ring
mm mm mm mm mm mm mm
(in) (in) (in) (in) (in) (in) (in)
21,6 13 16 36 54 38,1 17,5 46 5/16
RD2-SA/T12-N 1/2” 4075
(0.85) (0.51) (0.63) (1.42) (2.13) (1.50) (0.69) (1.81) -18 UNC-2B
17,5 13 16 36 54 38,1 17,5 46 5/16
RD2-SA/T38-N 3/8” 4075
(0.69) (0.51) (0.63) (1.42) (2.13) (1.50) (0.69) (1.81) -18 UNC-2B
27,2 19 18 36 65 47,6 22,2 50 3/8
RD2-SB/T34-N 3/4” 4100
(1.07) (0.75) (0.71) (1.42) (2.56) (1.87) (0.87) (1.97) -16 UNC-2B
34 25 18 38 70 52,4 26,2 52 3/8
RD2-SC/T100-N 1” 4131
(1.34) (0.98) (0.71) (1.50) (2.76) (2.06) (1.03) (2.05) -16 UNC-2B
01/09.2019

42,8 32 21 41 79 58,7 30,2 68 7/16


RD2-SD/T114-N 1” 1/4 4150
(1.69) (1.26) (0.83) (1.61) (3.11) (2.31) (1.19) (2.68) -14 UNC-2B
48,6 38 25 44 93 69,8 35,7 78 1/2
RD2-SE/T112-N 1” 1/2 4187
(1.91) (1.50) (0.98) (1.73) (3.66) (2.75) (1.41) (3.07) -14 UNC-2B
61 51 25 45 102 77,8 42,9 90 1/2
RD2-SF/T200-N 2” 4225
(2.40) (2.01) (0.98) (1.77) (4.02) (3.06) (1.69) (3.54) -14 UNC-2B

Standard port connectors are equipped with BUNA seals. For heavier operating conditions, require it with VITON seals repla-
ceing code’s last letter N with the V letter (eg. RD2-MA/T12-N - RD2-MA/T12-V).
Note: Torque values in the table refer to the mounting of port connectors on MAGNUM series.

DCAT018-ID02 27
Magnum

SAE BSPP THREAD ELBOWS

D018-D26/1212

A B C D E F G H
Type Screws O-ring
mm mm mm mm mm mm mm
Nominal size
(in) (in) (in) (in) (in) (in) (in)
G 3/4 Depth 19 19 19 38 66 47,6 22,2 46 M 10
RG2-MB/FG34-N 4100
(0.75) (0.75) (0.75) (1.50) (2.60) (1.87) (0.87) (1.81) UNI 5931-8.8
G 1 Depth 19 25 22 45 71 52,4 26,2 55 M 10
RG2-MC/FG100-N 4131
(0.75) (0.98) (0.87) (1.77) (2.80) (2.06) (1.03) (2.17) UNI 5931-8.8
G 1 1/4 Depth 22 31 27 55 81 58,7 30,2 65 M 10
RG2-MD/FG114-N 4150
(0.87) (1.22) (1.06) (2.17) (3.19) (2.31) (1.19) (2.56) UNI 5931-12.9
G 1 1/2 Depth 24 38 32 65 95 69,8 35,7 75 M 12
RG2-ME/FG112-N 4187
(0.94) (1.50) (1.26) (2.56) (3.74) (2.75) (1.41) (2.95) UNI 5931-12.9
M 12
G 2 Depth 26 51 40 80 112 77,8 42,9 90
RG2-MF/FG200-N UNI 5931- 4237
(1.02) (2.01) (1.57) (3.15) (4.41) (3.06) (1.69) (3.54)
12.9

Standard port connectors are equipped with BUNA seals. For heavier operating conditions, require it with VITON seals repla-
ceing code’s last letter N with the V letter (eg. RG2-MB/FG34-N - RG2-MB/FG34-V).
Note: Torque values in the table refer to the mounting of port connectors on MAGNUM series.

01/09.2019

28 DCAT018-ID02
Magnum

SAE NPT THREAD ELBOWS

D018-D26/1212

A B C D E F G H
Type Screws O-ring
mm mm mm mm mm mm mm
Nominal size
(in) (in) (in) (in) (in) (in) (in)
3/4 NPT Depth 19 19 19 38 66 47,6 22,2 46 M 10
RG2-MB/FN34-N 4100
(0.75) (0.75) (0.75) (1.50) (2.60) (1.87) (0.87) (1.81) UNI 5931-8.8
1 NPT Depth 19 25 22 45 71 52,4 26,2 55 M 10
RG2-MC/FN100-N 4131
(0.75) (0.98) (0.87) (1.77) (2.80) (2.06) (1.03) (2.17) UNI 5931-8.8
1 1/4 NPT Depth 22 31 27 55 81 58,7 30,2 65 M 10
RG2-MD/FN114-N 4150
(0.87) (1.22) (1.06) (2.17) (3.19) (2.31) (1.19) (2.56) UNI 5931-12.9
1 1/2 NPT Depth 24 38 32 65 95 69,8 35,7 75 M 12
RG2-ME/FN112-N 4187
(0.94) (1.50) (1.26) (2.56) (3.74) (2.75) (1.41) (2.95) UNI 5931-12.9
2 NPT Depth 26 51 40 80 112 77,8 42,9 90 M 12
RG2-MF/FN200-N 4237
(1.02) (2.01) (1.57) (3.15) (4.41) (3.06) (1.69) (3.54) UNI 5931-12.9

Standard port connectors are equipped with BUNA seals. For heavier operating conditions, require it with VITON seals repla-
ceing code’s last letter N with the V letter (eg. RG2-MB/FN34-N - RG2-MB/FN34-V).
Note: Torque values in the table refer to the mounting of port connectors on MAGNUM series.
01/09.2019

DCAT018-ID02 29
Magnum

SAE WELD IN ELBOWS

D018-D29/1212

A B C D E F G H I
Nom.
Type
size
Screws O-ring
mm mm mm mm mm mm mm mm
(in) (in) (in) (in) (in) (in) (in) (in)
27,2 19 19 38 66 47,6 22,2 5 46 M 10
RG2-MB/S34-N 3/4” 4100
(1.07) (0.75) (0.75) (1.50) (2.60) (1.87) (0.87) (0.20) (1.81) UNI 5931-8.8
34 25 22 45 71 52,4 26,2 6 55 M 10
RG2-MC/S100-N 1” 4131
(1.34) (0.98) (0.87) (1.77) (2.80) (2.06) (1.03) (0.24) (2.17) UNI 5931-8.8
42,8 31 27 55 81 58,7 30,2 7 65 M 10
RG2-MD/S114-N 1” 1/4 4150
(1.69) (1.22) (1.06) (2.17) (3.19) (2.31) (1.19) (0.28) (2.56) UNI 593-12.9
48,6 38 32 65 95 69,8 35,7 8 75 M 12
RG2-ME/S112-N 1” 1/2 4187
(1.91) (1.50) (1.26) (2.56) (3.74) (2.75) (1.41) (0.32) (2.95) UNI 593-12.9
61,3 51 40 80 112 77,8 42,9 10 90 M 12
RG2-MF/S200-N 2” 4225
(2.41) (2.01) (1.57) (3.15) (4.41) (3.06) (1.69) (0.39) (3.54) UNI 593-12.9

Standard port connectors are equipped with BUNA seals. For heavier operating conditions, require it with VITON seals repla-
ceing code’s last letter N with the V letter. (esempio: RG2-MB/S34-N - RG2-MB/S34-V).
Note: Torque values in the table refer to the mounting of port connectors on MAGNUM series.

01/09.2019

30 DCAT018-ID02
Magnum

SAE WELD ON ELBOWS

D018-D30/1212

A B C D E F G H I
Nom.
Type
size
Screws O-ring
mm mm mm mm mm mm mm mm
(in) (in) (in) (in) (in) (in) (in) (in)
27 19 23 38 70 47,6 22,2 44 63 M 10
RG2-MB/T34-N 3/4” 4100
(1.06) (0.75) (0.91) (1.50) (2.76) (1.87) (0.87) (1.73) (2.48) UNI 5931-8.8
34,5 23 25 42 75 52,4 26,2 48 72 M 10
RG2-MC/T100-N 1” 4112
(1.36) (0.91) (0.98) (1.65) (2.95) (2.06) (1.03) (1.89) (2.83) UNI 5931-8.8
43 31 27 48 86 58,7 30,2 56 82 M 10
RG2-MD/T114-N 1” 1/4 4150
(1.69) (1.22) (1.06) (1.89) (3.39) (2.31) (1.19) (2.20) (3.23) UNI 593-12.9
50 35 31,5 56 97 69,8 35,7 62 92 M 12
RG2-ME/T112-N 1” 1/2 150
(1.97) (1.38) (1.24 (2.20) (3.82) (2.75) (1.41) (2.44) (3.62) UNI 593-12.9
65 48 37,5 60 100 77,8 42,9 72 99 M 12
RG2-MF/T200-N 2” 156
(2.56) (1.89) (1.48) (2.36) (3.94) (3.06) (1.69) (2.83) (3.90) UNI 593-12.9

Standard port connectors are equipped with BUNA seals. For heavier operating conditions, require it with VITON seals repla-
ceing code’s last letter N with the V letter (eg. RG2-MB/T34-N - RG2-MB/T34-V).
Nota: Torque values in the table refer to the mounting of port connectors on MAGNUM series.
01/09.2019

DCAT018-ID02 31
Magnum

HOW TO ORDER

ORDER EXAMPLE FOR SECTIONS OF FLOW DIVIDER WITH 4 SECTIONS


Before ordering consult standard compositions at pages 12 - 13.

ME MD

D018-D14/1212

ME MC MB MB

Flow divider type see page 5

Inlet port code see page 14

Outlet port code see page 14

Seal see page 4

Sections code: T= end section


I= intermediate section

HDD 35•90 - / ME - N - T

C 35•30 - ME

HDD 30• 51 - / MC - N - I

HDD 30• 27 - MD / MB - N - I

HDD 30• 17 - / MB - N - T
01/09.2019

Inlet section type see page 12 - 13

Flow divider type see page 5

Omit code only in the order of assembled units.

ORDER EXAMPLE FOR ASSEMBLED FLOW DIVIDER WITH 4 SECTIONS

HDD 35•90 - ME + C 35•30 - ME + 51 - MC + 27 - MD / MB + 17 - MB - N

32 DCAT018-ID02
Magnum

HOW TO ORDER FLOW EQUALIZER WITH MOTOR SECTION

ORDER EXAMPLE FOR SECTIONS


Before ordering consult standard compositions at page 13

ME MD

D018-D24/1212

ME MC MC

Flow divider type see page 5

Inlet port code see page 14

Outlet port code see page 14

Seal see page 4

Sections code: T= end section


I= intermediate section

HDD 35•90 - / ME - N - T

F 35•30

HDD 30• 43 - MD / MC - N - I

HDD 30• 43 - / MC - N - T
01/09.2019

Flange type see page 13

Flow divider type see page 5

Omit code only in the order of assembled units.

ORDER EXAMPLE FOR ASSEMBLED SECTIONS

HDD 35•90 - MF / ME + F 35•30 + 43 - MD / MC + 43 - MC - N

DCAT018-ID02 33
Magnum

34 DCAT018-ID02
Our policy is one of continuous improvement in product. Specification of items may, therefore, be changed without
notice.
MD 01 T A Edition: 01/09.2019 Replaces: MD 01 T IE

GEAR FLOW
DIVIDERS
Headquarters:
CASAPPA S.p.A.
Via Balestrieri, 1
43044 Lemignano di Collecchio
Parma (Italy)
Tel. (+39) 0521 30 41 11
Fax (+39) 0521 80 46 00
E-mail: info@casappa.com
www.casappa.com

You might also like