b.3 Circulation System Observe Hierarchy of Roads Observe Hierarchy of Roads Observe Hierarchy of Roads
4. MINIMUM LOT
AREAS
Single Detached 100 sq. meter / unit 72 sq. meter / unit 64 sq. meters / unit
Single Attached / 75 sq. meter / unit 54 sq. meters / unit 48 sq. meters / unit
Duplex /
Semi-Detached
Row house 50 sq. meters (House & Lot) 36 sq. meters / unit 28 sq. meters / unit
PARAMETER PD 957 BP 220 BP 220
OPEN MARKET ECONOMIC HOUSING SOCIAL HOUSING
HOUSING
5. MINIMUM LOT
FRONTAGE
7.4 Alley
7.5 Footpath / 4.0m 3.0m 3.0m
Pathwalk 4.0m 3.0m 3.00
7.6 ROW of access to
interior lot 3.0m 3.0m 3.0m
+ Right of way (ROW) of major roads shall be increased as project size increases. ROW shall not be
lower than ROW of public road.
+ Major Roads shall maintain a uniform width of road right of way. Tapering of road width shall not be
allowed
NOTE: 1. Interior subdivision project must secure right of way to the nearest public road
2. Subdivision projects with direct access to a main public road must provide sufficient setback
To accommodate loading and unloading passengers.
3. Subdivision project shall provide provision for future expansion (see text)
8. MAXIMUM SIZES OF
PROJECT PER
HIERARCHY ROADS
Project Size Range major road, minor road, major road, minor road, motor court, alley
2.5 hectares and below motor court, footpath
9.1 Planting Strip (PS) 1.0m 1.0m 1.0m 1.0m 1.0m 1.0m
Sidewalk (SW) 1.0m 1.0m 0.5m 0.5m 0.5m 0.5m
NOTE: refer to supplemental rules and regulations to implement PD 963 (HLURB A.O. no. 2 series of
1994(April)
9.2 Road Pavement Developed Under Developed Under
area Developed area Developed
area area
+ The drainage system must conform with the natural drainage pattern of the
subdivision site, and shall drain into appropriate water bodies, public
drainage system or natural outfalls.
PARAMETER PD 957 BP 220 BP 220
OPEN MARKET ECONOMIC HOUSING SOCIALIZED HOUSING
HOUSING
12. SEWAGE DISPOSAL
SYSTEM
12.1 Septic Tank Individual septic Tank Individual septic Tank Individual / Communal
conforming to standard conforming to standard Septic Tank conforming
design of the Sanitation design of the Sanitation to standard design of
Code. Code. the Sanitation Code.
12.2 Connection to
Community Whenever possible, connections shall be made to an approved public or
Sewer System community sewer system subject to the requirements and provisions of the
Sanitation Code and other applicable rules and regulations with regards to
materials and installation practices.
13. POWER SUPPLY Developed Areas Under Developed Areas
b.1 Single-Detached b.1 Complete House b.1 Complete House b.1 Shell House
b.2 Duplex b.2 Complete House b.2 Complete House b.2 Shell House
b.3 Rowhouse b.3 Complete House b.3 Complete House b.3 Shell House
NOTE: Minimum floor area shall be in one floor
level exclusive of mezzanine floor if any.
16. SETBACKS /
EASEMENTS