Monobloc
Y ASSURED
LIT F
A
IRM
QU
ISO Specifications
Nominal Voltage 12 Volts
9001 UKAS
Design Life 12 Years
QUALITY
Operating Temperature -20 °C to 50 °C
SGS MANAGEMENT
005
Grid alloy
Plates
Calcium / Tin lead alloy
Flat Pasted
Separator AGM - Absorbant Glass Mat
Y ASSURED
LIT F Active material Very high purity lead
A
IRM
QU
SGS MANAGEMENT
005
Electrolyte Sulphuric acid Analytical grade
purity
Venting Valve EPDM Rubber 1.5 to 2 psi
(10.5 - 14 KPa) release
pressure. Resealing at 1 psi (7
KPa)
Terminal Epoxy sealed by extended
mechanical paths
Torque setting The recommended torque
value is 5-7 Nm
Connectors Supplied as standard (4 hr
Innovative Features rate)
Designed to meet the needs of UPS and many other diverse
applications where DC power is required on demand.
Multi-position usage.
The most suitable charging method for battery life and performance is the
constant voltage method with a limited initial current, usually limited to a
maximum of C20/4.
1 Hour to 100 Hours 28% 41% 58% 73% 79% 86% 94% 100% 104% 106% 107% 108%
W (B) W (D)
W (A)1
L
L L
W (C)
W (A)2 W (E)
19
29.5
HZ12V33EV connector
HZY12-33EV 3
63
195 130 R7.5
A A
To Terminal 150.5
15
Battery 159.5
12 A-A 6
A A
To Terminal 213
20
A tailor made solution to meet the customers
Battery 210
3
requirements. 16 A-A
HZ12V90/100 connector B
10
1390
225
30
212
Racking is available to suit
available space and
212
required configuration.
Product Range
Website: www.hazebattery.com
E mail sales@hazebattery.com
Note: The discharge data contained within is obtained
by laboratory testing of production batteries, results
may vary after a period of shipping and/or storage.