You are on page 1of 19

02/04/2020 Stripping with Volumetric Control Steps and Example Calculations - Drilling Formulas and Drilling Calculations

About This Blog Contact Us Privacy Policy

 MENU

SPONSORED SEARCHES
drilling rig volume calculator casing cementing

drilling well control drill pipe annular pressure

Stripping with Volumetric Control Steps and Example Calculations


By DrillingFormulas.Com | May 1, 2015 - 9:01 am |Well Control

 Post Views:947

Lame forged ttings


lame ttings.it

Forged ttings asme B16.11 Carbon


alloy and stainless steel

OPEN

This example demonstrates the calculations and the steps of the stripping with volumetric control so it will help you understand about what calculations
required are and how to perform the stripping with volumetric control.

Gas kick at the bottom but the drillstring is out of bottom. The kick is introduced while pulling out of hole and the following information below is the well
information.

Pit gain = 30 bbl


Shut in Drill Pipe Pressure = 400 psi
Shut in Casing Pressure = 400 psi
Current mud weight = 11.0 ppg
Casing shoe depth = 6,000’MD/6,000’TVD
Hole TD = 9,000’MD/9,000’TVD
Hole size = 12.25”
Casing ID = 12.5”
Drill pipe size = 5”, 19 ppf
BHA consists of 6.5” drill collar

Length of BHA = 800 ft
Average pipe per stand = 94 ft

www.drillingformulas.com/stripping-with-volumetric-control-steps-and-example-calculations/#more-5636 1/19
02/04/2020 Stripping with Volumetric Control Steps and Example Calculations - Drilling Formulas and Drilling Calculations

Rate of increase in casing pressure = 150 psi in 1 hour


Assume gas density = 2 ppg ( 0.104 psi/ft)

Figure 1 – Well Diagram

The decision is made to strip to the bottom. Safety Factor and Pressure Increment are 100 psi.

Assumption: Gas kick at the bottom

Kick Height

Kick height = kick volume ÷ hole capacity

Hole capacity = 12.252 ÷ 1029.4 = 0.1458 bbl/ft

Kick height = 30 ÷ 0.1458 = 206 ft

The top of gas kick is at 8,974 ft (9,000 – 206) before it migrates.

www.drillingformulas.com/stripping-with-volumetric-control-steps-and-example-calculations/#more-5636 2/19
02/04/2020 Stripping with Volumetric Control Steps and Example Calculations - Drilling Formulas and Drilling Calculations

Figure 2 – Top of Kick

Gas Migration Rate

Gas migration rate, fph = (Rate of increase in casing pressure, psi/hr) ÷ (0.052 x MW)

Gas migration rate, fph= 150 ÷ (0.052 x 11.0)

Gas migration rate = 262 fph

www.drillingformulas.com/stripping-with-volumetric-control-steps-and-example-calculations/#more-5636 3/19
02/04/2020 Stripping with Volumetric Control Steps and Example Calculations - Drilling Formulas and Drilling Calculations

Figure 3 – Gas Migration

Mud Increment

Mud Increment (MI) is calculated by the following equation

Where;

MI = Mud Increment (MI), bbl

PI = Pressure Increment (PI), psi

ACF = annular capacity factor between casing and drillstring, bbl/ft

MW = mud weight, ppg

ACF = (12.52 – 52) ÷ 1029.4 = 0.1275 bbl/ft

Mud Increment (MI) = 22.3 bbl 

www.drillingformulas.com/stripping-with-volumetric-control-steps-and-example-calculations/#more-5636 4/19
02/04/2020 Stripping with Volumetric Control Steps and Example Calculations - Drilling Formulas and Drilling Calculations

Metal Displacement per Stand

Metal Displacement (bbl) = (OD2 x Average Length) ÷ 1029.4

Metal Displacement (bbl) = (52 x 94) ÷ 1029.4

Metal Displacement (bbl) = 2.3 bbl

Stripping with Volumetric Control Procedures

1. We determine the Safety Factor (SF), Pressure Increment (PI) and Mud Increment (MI) as per the calculated shown in the above section
2. Strip into the well until the casing pressure increase is equal to Safety Factor (SF) + Pressure Increment (PI) which is 200 psi. At this stage, the
overbalance is 200 psi (100 + 100) and there is no bleeding back volume. From this example, we strip 2 stands to reach this point.

Drillstar Z-Reamer
Advanced Compact Underreamer
Innovative underreamer for lower hole
opening and reaming while drilling costs
drillstar-industries.com

OPEN

Figure 4 – Strip to get SF + MI

www.drillingformulas.com/stripping-with-volumetric-control-steps-and-example-calculations/#more-5636 5/19
02/04/2020 Stripping with Volumetric Control Steps and Example Calculations - Drilling Formulas and Drilling Calculations

Figure 5 – Strip to get SF + MI Diagram

3. Hold casing pressure constant and bleed off fluid volume while stripping in hole. For this step, we need track the actual volume bled back which is
equal to volume bled off minus pipe displacement.

Figure 6 – Bleed off volume while stripping

Let’s take a look at Figure 6, the stand#3 bleeds 2 bbl and the metal displacement is 2.3 bbl. Therefore, you will have only 1.7 bbl of mud bled off. The
overbalance reduces to 192 psi because 1.7 bbl of mud is out of the wellbore. You need to strip in until the total bled minus total stripped is equal to 22 a
target mud increment which is 22.3 bbl.

www.drillingformulas.com/stripping-with-volumetric-control-steps-and-example-calculations/#more-5636 6/19
02/04/2020 Stripping with Volumetric Control Steps and Example Calculations - Drilling Formulas and Drilling Calculations

Figure 7 – Bleed off while stripping until the mud increment is reached.

According to Figure 7, you need to strip a total of 12 stands in order to reach the target MI at 22.3 bbl and this point will have only 100 pis over balance.

Figure 8 – Stripping until the MI is reached.

4. Strip in a shut in well until the safety factor is reach. At this example, we strip in to get additional 100 psi so the casing pressure will be 700 psi and
the overbalance is 200 psi.

www.drillingformulas.com/stripping-with-volumetric-control-steps-and-example-calculations/#more-5636 7/19
02/04/2020 Stripping with Volumetric Control Steps and Example Calculations - Drilling Formulas and Drilling Calculations

Figure 9 – Stand#13 stripped in a shut in well

Figure 10 – Strip in a shut in well until 100 psi is reached (700 psi surface pressure)

5. We will continue step#3 and step#4 until the drillstring reaches the bottom or the desired depth. Then you can carry on the conventional well control
methods as driller’s method, wait and weight etc.

www.drillingformulas.com/stripping-with-volumetric-control-steps-and-example-calculations/#more-5636 8/19
02/04/2020 Stripping with Volumetric Control Steps and Example Calculations - Drilling Formulas and Drilling Calculations

Figure 11 – Continue Stripping by repeating step#3 and step#4

Figure 12 – Strip to desired depth

Reference books: Well Control Books

www.drillingformulas.com/stripping-with-volumetric-control-steps-and-example-calculations/#more-5636 9/19
02/04/2020 Stripping with Volumetric Control Steps and Example Calculations - Drilling Formulas and Drilling Calculations

Share the joy


213

0
Shares

Tagged Stripping, stripping operation, Well Control. Bookmark the permalink.

About DrillingFormulas.Com
Working in the oil field and loving to share knowledge.
View all posts by DrillingFormulas.Com →

« Down Hole Video Camera – Amazing To See How Actual Oil & Gas Wells Directional Drilling Disaster ? »
Look Like

Leave a reply

Default Comments (0) Facebook Comments


Your email address will not be published. Required fields are marked *

Comment

Name *

Email *

Website

Post Comment

This site uses Akismet to reduce spam. Learn how your comment data is processed.


Categories

www.drillingformulas.com/stripping-with-volumetric-control-steps-and-example-calculations/#more-5636 10/19
02/04/2020 Stripping with Volumetric Control Steps and Example Calculations - Drilling Formulas and Drilling Calculations

Select Category

Get Drilling Formulas Sheet For Free

Subscribe to Get Free Calculation Sheet

email address

Click Here

Search on Drillingformulas.com

Search

Custom Search

Well Control One Page

Drillingformulas.com on Facebook

Drillingformulas.…
344 K mentions J’aime

J’aime cette Page

2 amis aiment ça

OilfieldPix.com

www.drillingformulas.com/stripping-with-volumetric-control-steps-and-example-calculations/#more-5636 11/19
02/04/2020 Stripping with Volumetric Control Steps and Example Calculations - Drilling Formulas and Drilling Calculations

Oilfield Acronyms

Recent Comments

Ahmad Alshammari on Possible Wellbore Problems during Well Kill Operation

Ahmad Alshammari on Possible Wellbore Problems during Well Kill Operation

DrillingFormulas.Com on Kill Weight Mud

DrillingFormulas.Com on Kill Weight Mud

Dellabani Mouloud on Driller’s Method Quiz No. 1

www.drillingformulas.com/stripping-with-volumetric-control-steps-and-example-calculations/#more-5636 12/19
02/04/2020 Stripping with Volumetric Control Steps and Example Calculations - Drilling Formulas and Drilling Calculations

www.drillingformulas.com/stripping-with-volumetric-control-steps-and-example-calculations/#more-5636 13/19
02/04/2020 Stripping with Volumetric Control Steps and Example Calculations - Drilling Formulas and Drilling Calculations

www.drillingformulas.com/stripping-with-volumetric-control-steps-and-example-calculations/#more-5636 14/19
02/04/2020 Stripping with Volumetric Control Steps and Example Calculations - Drilling Formulas and Drilling Calculations

www.drillingformulas.com/stripping-with-volumetric-control-steps-and-example-calculations/#more-5636 15/19
02/04/2020 Stripping with Volumetric Control Steps and Example Calculations - Drilling Formulas and Drilling Calculations

www.drillingformulas.com/stripping-with-volumetric-control-steps-and-example-calculations/#more-5636 16/19
02/04/2020 Stripping with Volumetric Control Steps and Example Calculations - Drilling Formulas and Drilling Calculations

www.drillingformulas.com/stripping-with-volumetric-control-steps-and-example-calculations/#more-5636 17/19
02/04/2020 Stripping with Volumetric Control Steps and Example Calculations - Drilling Formulas and Drilling Calculations

www.drillingformulas.com/stripping-with-volumetric-control-steps-and-example-calculations/#more-5636 18/19
02/04/2020 Stripping with Volumetric Control Steps and Example Calculations - Drilling Formulas and Drilling Calculations

Drilling Formulas and Drilling Calculations | Powered by Mantra & WordPress.

www.drillingformulas.com/stripping-with-volumetric-control-steps-and-example-calculations/#more-5636 19/19

You might also like