ROOF LEVEL

weight of structure (KN)


columns:
base height unit weight no. length 192
0.4 0.4 24 50 1

beams:
base height unit weight length
2168.64
0.3 0.4 24 753

slab:
thickness area unit weight
5904
0.15 1640 24

ceiling:
design load area
1312
0.8 1640

floor finish:
design load area
1804
1.1 1640

wall:
design load depth length
436.8
2.4 1 182

parapet:
design load depth length
87.36
0.48 1 182

total weight of level = 11904.8


3RD FLOOR LEVEL

weight of structure (KN)


columns:
base height unit weight no. length 1810.38
0.45 0.45 24 90 3.7

beams:
base height unit weight length
3252.96
0.4 0.45 24 753

slab:
thickness area unit weight
5814
0.15 1615 24

ceiling:
design load area
1292
0.8 1615

floor finish:
design load area
1776.5
1.1 1615

wall:
design load depth length
2052.96
2.4 3.7 182

partition:
design load depth length
1332
1 3.7 360

total weight of level = 17330.8


2ND FLOOR LEVEL

weight of structure (KN)


columns:
base height unit weight no. length 3236.76
0.45 0.45 24 90 3.7

beams:
base height unit weight length
3614.4
0.4 0.5 24 753

slab:
thickness area unit weight
5814
0.15 1615 24

ceiling:
design load area
1292
0.8 1615

floor finish:
design load area
1776.5
1.1 1615

wall:
design load depth length
3232.32
2.4 3.7 182

partition:
desig load depth length
1332
1 3.7 360

total weight of level = 20297.98


GROUND FLOOR LEVEL

weight of structure (KN)


columns:
base height unit weight no. length
0.55 0.55 24 90 4.2 2744.28

TOTAL WEIGHT (KN)


52277.86

Table 103-1 Occupancy Category NSCP:2001 category III


Table 208-1 seismic Importance Factor IW = 1
Figure 208-1 Seismic Zone Map of the Philippines z = 0.4
soil Profile Type rock = Sb
ca = 0.4 Na
cv = 0.4 Nv
Assume:
M > or = 7.0 Seismic Source Type : A
Closest distance to known seismic source: < or = 5km
Na = 1.2
Nv = 1.6

Special Moment- Resisting Frame (SMRF) R = 8.5


therefore ct = 0.0731
equation (208-8) NSCP:2001
T=CT (hn)3/4 hn T
2nd level 4.2 0.214464
3rd level 7.9 0.344459
roof level 11.6 0.459474

Ft for all level are less than 0.7 seconds therefore may be considered as zero
(NSCP :2001 section 208.5.5)
Ft = 0
ROOF LEVEL
(kN)
Vmax = 2.5 Ca Iw w/R = 7380.4037647
VALLOWABLE = CVIW/RT = 8566.7872328
vmin = 0.11 CaIW = 2760.271008

in addition for seismic zone 4, the total base shear shall also be less than the following:

V = 0.8ZNvIw/R (equation 208-7) = 3148.9722729

therefore use Vmax 7380.404 kN

3rd LEVEL
(kN)
Vmax = 2.5 Ca Iw w/R = 7380.4037647
VALLOWABLE = CVIW/RT = 11427.234882
vmin = 0.11 CaIW = 2760.271008

in addition for seismic zone 4, the total base shear shall also be less than the following:

V = 0.8ZNvIw/R (equation 208-7) = 3148.9722729

therefore use Vmax 7380.404 kN

2nd LEVEL
(kN)
Vmax = 2.5 Ca Iw w/R = 7380.4037647
VALLOWABLE = CVIW/RT = 18353.73703
vmin = 0.11 CaIW = 2760.271008

in addition for seismic zone 4, the total base shear shall also be less than the following:

V = 0.8ZNvIw/R (equation 208-7) = 3148.9722729

therefore use Vmax 7380.404 kN


equation (208-15) Fx = (V-Ft)WxHx/(summation of WH)

SUMMARY:
Level Hx,in meter Wx in KN wx H x Fx
Ground 0 2744.28 0 0
Second 4.2 20297.98 85251.516 3252.922
Third 3.7 17330.8 64123.96 2446.762
Roof 3.7 11904.8 44047.76 1680.72

sum : 193423.236 kN-m

FORCES @ LONGITUDINAL SECTION: no. of spans = 13

HEIGHT, m FORCES, kN SHEAR ,KN MOMENT KN-m


Ground 0 0 567.72336652 4037.542
Second 4.2 250.22473341 567.72336652 1653.104
Third 3.7 188.21249814 317.4986331 478.3587
Roof 3.7 129.28613496 129.28613496 0

FORCES @ TRANSVERSAL SECTION: no. of spans = 6

HEIGHT, m FORCES, kN SHEAR ,KN MOMENT KN-m


Ground 0 0 1230.0672941 8748.007
Second 4.2 542.15358906 1230.0672941 3581.725
Third 3.7 407.79374597 687.91370505 1036.444
Roof 3.7 280.11995909 280.11995909 0
ROOF LEVEL

weight of structure (KN)


columns:
base height unit weight no. length 322.56
0.4 0.4 24 84 1

beams:
base height unit weight length
2280.96
0.3 0.4 24 792

slab:
thickness area unit weight
6544.8
0.15 1818 24

ceiling:
design load area
1454.4
0.8 1818

floor finish:
design load area
1999.8
1.1 1818

wall:
design load depth length
856.8
2.4 1.5 238

parapet:
design load depth length
114.24
0.48 1 238

total weight of level = 13573.56


3RD FLOOR LEVEL

weight of structure (KN)


columns:
base height unit weight no. length 821.196
0.45 0.45 24 54 1.9

beams:
base height unit weight length
1706.4
0.4 0.45 24 395

slab:
thickness area unit weight
2352.6
0.15 653.5 24

ceiling:
design load area
522.8
0.8 653.5

floor finish:
design load area
1061.5
1.1 965

wall:
design load depth length
1440
2.4 1.8 135

partition:
desig load depth length
633.6
1 3.6 176

total weight of level = 8538.096


2ND FLOOR LEVEL

weight of structure (KN)


columns:
base height unit weight no. length 1271.376
0.45 0.45 24 53 3

beams:
base height unit weight length
1828.8
0.4 0.5 24 381

slab:
thickness area unit weight
1512
0.1 630 24

ceiling:
design load area
504
0.8 630

floor finish:
design load area
693
1.1 630

wall:
design load depth length
1725.6
2.4 2 238

partition:
desig load depth length
714
1 3 238

total weight of level = 8248.776


GROUND FLOOR LEVEL

weight of structure (KN)


columns:
base height unit weight no. length
0.5 0.5 24 53 4.5 1431

TOTAL WEIGHT (KN)


31791.432

Table 103-1 Occupancy Category NSCP:2001 category III


Table 208-1 seismic Importance Factor IW = 1
Figure 208-1 Seismic Zone Map of the Philippines z = 0.4
soil Profile Type rock = Sb
ca = 0.4 Na
cv = 0.4 Nv
Assume:
M > or = 7.0 Seismic Source Type : A
Closest distance to known seismic source: < or = 5km
Na = 1.2
Nv = 1.6

Special Moment- Resisting Frame (SMRF) R = 8.5


therefore ct = 0.0731
equation (208-8) NSCP:2001
T=CT (hn)3/4 hn T
2nd level 4.5 0.225853
3rd level 7.5 0.331294
roof level 10.5 0.426392

Ft for all level are less than 0.7 seconds therefore may be considered as zero
(NSCP :2001 section 208.5.5)
Ft = 0
ROOF LEVEL
(kN)
Vmax = 2.5 Ca Iw w/R = 4488.2021647
VALLOWABLE = CVIW/RT = 5613.8627102
vmin = 0.11 CaIW = 1678.5876096

in addition for seismic zone 4, the total base shear shall also be less than the following:

V = 0.8ZNvIw/R (equation 208-7) = 1914.9662569

therefore use Vmax 4488.202 kN

3rd LEVEL
(kN)
Vmax = 2.5 Ca Iw w/R = 4488.2021647
VALLOWABLE = CVIW/RT = 7225.3321135
vmin = 0.11 CaIW = 1678.5876096

in addition for seismic zone 4, the total base shear shall also be less than the following:

V = 0.8ZNvIw/R (equation 208-7) = 1914.9662569

therefore use Vmax 4488.202 kN

2nd LEVEL
(kN)
Vmax = 2.5 Ca Iw w/R = 4488.2021647
VALLOWABLE = CVIW/RT = 10598.499326
vmin = 0.11 CaIW = 1678.5876096

in addition for seismic zone 4, the total base shear shall also be less than the following:

V = 0.8ZNvIw/R (equation 208-7) = 1914.9662569


therefore use Vmax 4488.202 kN
equation (208-15) Fx = (V-Ft)WxHx/(summation of WH)

SUMMARY:
Level Hx,in meter Wx in KN wx H x Fx
Ground 0 1431 0 0
Second 4 8248.776 32995.104 1295.561
Third 3.8 8538.096 32444.7648 1273.952
Roof 3.6 13573.56 48864.816 1918.689

sum : 114304.6848 kN-m

FORCES @ LONGITUDINAL SECTION: no. of spans = 11

HEIGHT, m FORCES, kN SHEAR ,KN MOMENT KN-m


Ground 0 0 408.01837861 3230.082
Second 4.5 117.77827706 408.01837861 1393.999
Third 3 115.81380371 290.24010155 523.2789
Roof 3 174.42629784 174.42629784 0

FORCES @ TRANSVERSAL SECTION: no. of spans = 7

HEIGHT, m FORCES, kN SHEAR ,KN MOMENT KN-m


Ground 0 0 641.17173782 5075.843
Second 4.5 185.08014967 641.17173782 2190.57
Third 3 181.99312011 456.09158814 822.2954
Roof 3 274.09846803 274.09846803 0
455