WIND LOAD – LONGITUDINAL SECTION

(FACTOR METHOD)

COMPUTATION OF STIFFNESS
I
K=
L

Where:

b h3
I=
12

L=length of beams∧columns

SIZES OF COLUMNS AND HEIGHT           HEIGHT,in meters


BEAMS, in
        COLUMNS, in mm   mm        
FIRST FLOOR     500 500   450 500     4  
                         
SECOND
FLOOR     450 450   400 450     3.8  

STIFFNESS COMPUTATIONS, in mm^3  

           
FOR COLUMNS, x10^4
      mm^3

           

   

GROUND TO SECOND FLOOR 130

           

           

SECOND TO THIRD FLOOR 90

           

           
FOR BEAMS
  WIDTH 2ND FLOOR, x10^4 ROOF LEVEL,x10^4
B1 5.00 94 37
             
B2 5.00 94 37
             
B3 5.00 94 37
             
B4 4.00 117 47
             
B5 5.50 85 34
             
B6 5.50 85 34
             
B7 5.50 85 34
             
B8 5.50 85 34
             
B9 4.00 117 47
             
B10 5.00 94 37
             
B11 5.00 94 37
             
B12 5.00 94 37
COMPUTATION OF GIRDER FACTOR, G FOR EACH JOINT

     
ΞK COLUMN
G= ΞK @ JOINT
     

SECOND FLOOR
ROOF LEVEL

A-B 0.622 A-B 0.701


B-A 0.452 B-A 0.539
B-C 0.452 B-C 0.539
C-B 0.452 C-B 0.539
C-D 0.452 C-D 0.539
D-C 0.421 D-C 0.510
D-E 0.421 D-E 0.510
E-D 0.430 E-D 0.521
E-F 0.430 E-F 0.521
F-E 0.473 F-E 0.564
F-G 0.473 F-G 0.564
G-F 0.473 G-F 0.564
G-H 0.473 G-H 0.564
H-G 0.473 H-G 0.564
H-I 0.473 H-I 0.564
I-H 0.430 I-H 0.521
I-J 0.430 I-J 0.521
J-I 0.421 J-I 0.510
J-K 0.421 J-K 0.510
K-J 0.452 K-J 0.539
K-L 0.452 K-L 0.539
L-K 0.452 L-K 0.539
L-M 0.622 L-M 0.539
M-L 0.622 M-L 0.701
COMPUTATION OF COLUMN FACTOR, C

FORMULA: C= 1-GIRDER FACTOR

SECOND
ROOF TOP FLOOR

A   0.378   0.299   0.299  


B   0.548   0.461   0.461  
C   0.548   0.461   0.461  
D   0.579   0.490   0.490  
E   0.570   0.479   0.479  
F   0.527   0.436   0.436  
G   0.527   0.436   0.436  
H   0.527   0.436   0.436  
I   0.570   0.479   0.479  
J   0.579   0.490   0.490  
K   0.548   0.461   0.461  
L   0.548   0.461   0.461  
M   0.378   0.299   0.299  
130 90

1.150 0.799 0.443 0.438


0.150 0.500 0.144 0.150
A   1.000 0.299 0.299 0.288
       
1.231 0.961 0.685 0.678
0.231 0.500 0.224 0.231
B   1.000 0.461 0.461 0.447
       
1.231 0.961 0.685 0.678
0.231 0.500 0.224 0.231
C   1.000 0.461 0.461 0.447
       
1.245 0.990 0.728 0.721
0.245 0.500 0.238 0.245
D   1.000 0.490 0.490 0.476
       
1.240 0.979 0.712 0.705
0.240 0.500 0.233 0.240
E   1.000 0.479 0.479 0.465
       
1.218 0.936 0.647 0.639
0.218 0.500 0.211 0.218
F   1.000 0.436 0.436 0.421
       
1.218 0.936 0.647 0.639
0.218 0.500 0.211 0.218
G   1.000 0.436 0.436 0.421
       
1.218 0.936 0.647 0.639
0.218 0.500 0.211 0.218
H   1.000 0.436 0.436 0.421
       
1.240 0.979 0.712 0.705
0.240 0.500 0.233 0.240
I   1.000 0.479 0.479 0.465
       
1.245 0.990 0.728 0.721
0.245 0.500 0.238 0.245
J   1.000 0.490 0.490 0.476
       
1.231 0.961 0.685 0.678
0.231 0.500 0.224 0.231
K   1.000 0.461 0.461 0.447
       
1.231 0.961 0.685 0.678
0.231 0.500 0.224 0.231
L   1.000 0.461 0.461 0.447
       
1.150 0.799 0.443 0.438
0.150 0.500 0.144 0.150
M   1.000 0.299 0.299 0.288
       

LONGITUDINAL SECTION

COMPUTATION OF GIRDER MOMENT FACTOR, Q

COMPUTATION OF COLUMN MOMENT FACTOR

  2ND TO ROOF LEVEL   1ST TO 2ND FLOOR


             
A   39.870 39.375   149.435 103.870

B   61.605 60.975   159.965 124.930

C   61.605 60.975   159.965 124.930

D   65.520 64.890   161.850 128.700

E   64.035 63.405   161.135 127.270

F   58.185 57.510   158.340 121.680

G   58.185 57.510   158.340 121.680

H   58.185 57.510   158.340 121.680

I   64.035 63.405   161.135 127.270

J   65.520 64.890   161.850 128.700

K   61.605 60.975   159.965 124.930

L   61.605 60.975   159.965 124.930

M   39.870 39.375   149.435 103.870


ΞQ= 1511.595 3644.160
COMPUTATION OF GIRDER MOMENT FACTOR

ROOF LEVEL SECOND LEVEL


     
A-B   31.376   91.274
B-A   28.231   83.660
B-C   25.086   76.046
C-B   25.086   76.046
C-D   24.513   74.636
D-C   23.939   73.320
D-E   29.892   90.207
E-D   30.104   90.792
E-F   22.661   68.255
F-E   23.392   70.125
F-G   24.123   71.910
G-F   24.123   71.910
G-H   24.123   71.910
H-G   24.123   71.910
H-I   23.392   70.125
I-H   22.661   68.255
I-J   30.104   90.792
J-I   29.892   90.207
J-K   23.939   73.320
K-J   24.513   74.636
K-L   25.086   49.319
L-K   25.086   49.319
L-M   28.231   83.613
M-L   31.376   91.227
COMPUTATION OF CONSTANT, Nx
FORMULA WHERE
: :
ΞH (h) Nx-moment constant @ x-storey
Nx
= ΞQ COLUMN EH-sum of lateral forces for x-storey
EQ-sum of column moment factor for the
storey
h-height of every storey

3RD FLOOR
EQ= 1129
EH= 9.2
h= 3.5
9.2 X 3.5
N=   1128.751  

N= 0.028527
2ND FLOOR
EQ= 1512
EH= 20.5
h= 3.8
20.5 X 3.8
N=   1512  

N= 0.051535
1ST FLOOR
EQ= 3644.16
EH= 31.3
h= 4
31.3 X 4
N=   3644  

N= 0.034356
COMPUTATION OF COLUMN MOMENTS

FORMULA: M=Nx (Column Moment Factor)

2ND FLOOR 1ST FLOOR


LOWER UPPER LOWER UPPER
2.055 2.029 5.134 3.569

3.175 3.142 5.496 4.292

3.175 3.142 5.496 4.292

3.377 3.344 5.561 4.422

3.300 3.268 5.536 4.373

2.999 2.964 5.440 4.180

2.999 2.964 5.440 4.180

2.999 2.964 5.440 4.180

3.300 3.268 5.536 4.373

3.377 3.344 5.561 4.422

3.175 3.142 5.496 4.292

3.175 3.142 5.496 4.292

2.055 2.029 5.134 3.569


COMPUTATION OF JOINT FACTOR FOR GIRDER

FORMULA:
ΞM Column Moment @ joint
J= ξQ Girder @ Joint

ROOF LEVEL 2ND LEVEL


     
J1 0.029 0.062
J2 0.025 0.047
J3 0.027 0.05
J4 0.026 0.048
J5 0.026 0.048
J6 0.027 0.051
J7 0.027 0.05
J8 0.027 0.051
J9 0.026 0.048
J10 0.026 0.048
J11 0.027 0.06
J12 0.025 0.056
J13 0.029 0.062

COMPUTATION OF GIRDER MOMENTS

FORMULA: M=J (GIRDER MOMENT FACTOR)

ROOF LEVEL 2ND LEVEL


31.37 0.91 0.06 91.27 5.65
A-B 0.029 6 0 2 4 9
28.23 0.70 0.04 83.66 3.93
B-A 0.025 1 6 7 0 2
25.08 0.62 0.04 76.04 3.57
B-C 0.025 6 7 7 6 4
25.08 0.67 0.05 76.04 3.80
C-B 0.027 6 7 0 6 2
24.51 0.66 0.05 74.63 3.73
C-D 0.027 3 2 0 6 2
23.93 0.62 0.04 73.32 3.51
D-C 0.026 9 2 8 0 9
29.89 0.77 0.04 90.20 4.33
D-E 0.026 2 7 8 7 0
30.10 0.78 0.04 90.79 4.35
E-D 0.026 4 3 8 2 8
22.66 0.58 0.04 68.25 3.27
E-F 0.026 1 9 8 5 6
23.39 0.63 0.05 70.12 3.57
F-E 0.027 2 2 1 5 6
24.12 0.65 0.05 71.91 3.66
F-G 0.027 3 1 1 0 7
24.12 0.65 0.05 71.91 3.59
G-F 0.027 3 1 0 0 6
24.12 0.65 0.05 71.91 3.59
G-H 0.027 3 1 0 0 6
24.12 0.65 0.05 71.91 3.66
H-G 0.027 3 1 1 0 7
23.39 0.63 0.05 70.12 3.57
H-I 0.027 2 2 1 5 6
22.66 0.58 0.04 68.25 3.27
I-H 0.026 1 9 8 5 6
I-J 0.026 30.10 0.78 0.04 90.79 4.35
4 8 2
3 8
29.89 0.77 0.04 90.20 4.33
J-I 0.026 2 7 8 7 0
23.93 0.62 0.04 73.32 3.51
J-K 0.026 9 2 8 0 9
24.51 0.66 0.06 74.63 4.47
K-J 0.027 3 2 0 6 8
25.08 0.67 0.06 49.31 2.95
K-L 0.027 6 7 0 9 9
25.08 0.62 0.05 49.31 2.76
L-K 0.025 6 7 6 9 2
28.23 0.70 0.05 83.61 4.68
L-M 0.025 1 6 6 3 2
31.37 0.91 0.06 91.22 5.65
M-L 0.029 6 0 2 7 6

WIND LOAD – LONGITUDINAL SECTION

(FACTOR METHOD)

SUMMARY TABLE

MEMBER    
JOINT MOMENT - (Kn-m)
S    
            COLUMN GIRDER
1     1-15     5.134          
2     2-16     5.496          
3     3-17     5.496          
4     4-18     5.561          
5     5-19     5.536          
6     6-20     5.440          
7     7-21     5.440          
8     8-22     5.440          
9     9-23     5.536          
10     10-24     5.561          
11     11-25     5.496          
12     12-26     5.496          
13     13-27     5.134          
15     15-1     3.569          
      15-16             5.659  
      15-29     2.055          
16     16-2     4.292          
      16-15             3.932  
      16-17             3.574  
      16-30     3.175          
17     17-3     4.292          
      17-16             3.802  
      17-18             3.732  
      17-31     3.175          
18     18-4     4.422          
      18-17             3.519  
      18-19             4.330  
      18-32     3.377          
19     19-5     4.373          
      19-18             4.358  
      19-20             3.276  
      19-33     3.300          
20     20-6     4.180          
      20-19             3.576  
      20-21             3.667  
      20-34     2.999          
21     21-7     4.180          
      21-20             3.596  
      21-22             3.596  
      21-35     2.999          
22     22-8     4.180          
      22-21             3.667  
      22-23             3.576  
      22-36     2.999          
23     23-9     4.373          
      23-22             3.276  
      23-24             4.358  
      23-37     3.300          
24     24-10     4.422          
      24-23             4.330  
      24-25             3.519  
      24-38     3.377          
25     25-11     4.292          
      25-24             4.478  
      25-26             2.959  
      25-39     3.175          
26     26-12     4.292          
      26-25             2.762  
      26-27             4.682  
      26-40     3.175          
27     27-13     3.569          
      27-26             5.656  
      27-41     2.055          
29     29-15     2.029          
      29-30             2.835  
      29-43     0.830          
30     30-16     3.142          
      30-29             2.273  
      30-31             2.075  
      30-44     1.255          
31     31-17     3.142          
      31-30             2.226  
      31-32             2.187  
      31-45     1.255          
32     32-18     3.344          
      32-31             2.100  
      32-33             2.587  
      32-46     1.332          
33     33-19     3.268          
      33-32             2.605  
      33-34             1.950  
      33-47     1.305          
34     34-20     2.964          
      34-33             2.049  
      34-35             2.102  
      34-48     1.191          
35     35-21     2.964          
      35-34             2.054  
      35-36             2.054  
      35-49     1.191          
36     36-22     2.964          
      36-35             2.102  
      36-37             2.049  
      36-50     1.191          
37     37-23     3.268          
      37-36             1.950  
      37-38             2.605  
      37-51     1.305          
38     38-24     3.344          
      38-37             2.587  
      38-39             2.100  
      38-52     1.332          
39     39-25     3.142          
      39-38             2.187  
      39-40             2.226  
      39-53     1.255          
40     40-26     3.142          
      40-39             2.075  
      40-41             2.273  
      40-54     1.255          
41     41-27     2.029          
      41-40             2.834  
      41-55     0.830          
43     43-29     0.908          
      43-44             0.910  
44     44-30     1.343          
      44-43             0.706  
      44-45             0.627  
45     45-31     1.343          
      45-44             0.677  
      45-46             0.662  
46     46-32     1.422          
      46-45             0.622  
      46-47             0.777  
47     47-33     1.396          
      47-46             0.783  
      47-48             0.589  
48     48-34     1.283          
      48-47             0.632  
      48-49             0.651  
49     49-35     1.283          
      49-48             0.651  
      49-50             0.651  
50     50-36     1.283          
      50-49             0.651  
      50-51             0.632  
51     51-37     1.396          
      51-50             0.589  
      51-52             0.783  
52     52-38     1.422          
      52-51             0.777  
      52-53             0.622  
53     53-39     1.343          
      53-52             0.662  
      53-54             0.677  
54     54-40     1.343          
      54-53             0.627  
      54-55             0.706  
55     55-41     0.908          
      55-54             0.910  