Professional Documents
Culture Documents
BMS
BMS hs, BMS hp, BMST, BMSX
1. Product introduction 4
Table of contents
2. Performance range 5
BMS hs PM booster system. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
BMS hs AC booster system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
BMS hp MG/MGE booster system. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4. Grundfos BMS hs 9
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Standard pumps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Operating limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Construction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Motor types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Frequency converter for PM motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5. Grundfos BMS hp 13
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Standard pumps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Operating limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Frequency converter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
9. Sizing 20
2
BMS
Table of contents
BMS hs AC, 17-22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
BMS hs AC, 30-14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
BMS hs AC, 30-26 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
BMS hs AC, 46-17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
BMS hs AC, 60-17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
BMS hp, 17-3, 17-5 and 17-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
BMS hp, 30-3, 30-5 and 30-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
BMS hp, 46-2, 46-4 and 46-6A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
BMS hp, 60-2, 60-4 and 60-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
BMS hp, 77-2A and 77-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
BMS hp, 95-2 and 95-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
BMS hp, 125-1 and 125-2AA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
BMS hp, 160-1A, 160-1 and 160-2AA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
BMS hp, 215-1A and 215-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
14. Accessories 59
CUE frequency converter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
BMS hp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Customised BMS pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
3
1 BMS
1. Product introduction
Product introduction
Grundfos BMS hp
BMS hp is especially used when a high inlet pressure
is needed. BMS hp is a range of booster systems for
reverse osmosis and filtration applications offering
higher efficiency than previous ranges. BMS hp is
available with both MG and MGE motor (max. size 30
kW).
TM06 1045 5115
4
BMS
2
2. Performance range
Performance range
BMS hs PM booster system
p H
[psi] [m]
1400 1000 BMShs PM
900
1200
800
1000 700
17-22 30-26
600
800
500
600 46-17
400
300 60-17
400
200
200
100
30-14
0 0
0 50 100 150 200 250 300 350 400 450 500 550
Q [US GPM]
Fig. 3 Performance range, BMS hs, PM
600
800
500
46-17
600
400
400 300
30-14 60-17
200
200
100 7-42
0 0
TM06 5614 4818
0 50 100 150 200 250 300 350 400 450 500 550
Q [US GPM]
Fig. 4 Performance range, BMS hs AC
Note: We offer customised variants of the BMS type for a variety of applications. Contact Grundfos for further
information.
5
2 BMS
S +
>SVL@ >P@
%06KS
%06KS
%06KS
%06KS
%06KS
%06KS
%06KS
%06KS
%06KS
%06KS
BMS hp 6"
BMS hp 8"
4>86*30@
Fig. 5 Performance range, BMS hp MG/MGE, 60 Hz
Note: We offer customised variants of the BMS type for a variety of applications. Contact Grundfos for further
information.
6
BMS
3
P NBR
Parallel operation
V FKM
If a flow rate higher than that of a single module is
Shaft seal required, several modules are connected in parallel.
A Silicon carbide and carbon
Find the resulting flow rate by adding the flow rate of
Note: * Grundfos motors each individual module. The pressure will be the same
Grundfos MG and MMG: as for one pump.
• Requires an external frequency converter.
Grundfos PM (permanent-magnet motor) and AC (asynchronous
motor):
• Requires an external frequency converter. Flushing
Grundfos MGE and MMGE:
• With integrated frequency converter. When the booster system is used in a reverse osmosis
system or similar applications, such as pumping
seawater or aggressive water, install a flush pump to
Pumped liquids avoid corrosion. Flush the system with clean fresh
Thin, non-explosive liquids, not containing solid water until the salinity is lower than 1000 ppm TDS in
particles or fibres. The liquid must not chemically the entire system.
attack the pump materials. In case of doubt, contact
Grundfos.
Filtration
The pumps must never operate with liquid containing
substances that would remove the surface tension, for BMS hs, BMS hp, BMST: Filter the raw water to
example soap. If you use this type of detergent to maximum 30 microns.
clean the system, lead the liquid around the pumps via BMSX (up to PX 180): Filter the raw water to maximum
a bypass. 5 microns.
If the density and/or viscosity of the pumped liquid is BMSX (larger than PX 180): Filter the raw water to
higher than that of water, it may be necessary to use maximum 10 microns.
motors with a higher output than the standard output
Filter
stated. Pump type
[micron absolute]
BMS pumps are designed for different water BMS hs
applications and are specially designed for brackish BMS hp 30
water and seawater. BMST
Pressure exchanger 10
Maximum liquid temperature
40 °C (104 °F)
Contact Grundfos in case of higher temperatures.
7
3 BMS
General description, BMS hs and BMS hp
7
Built-in non-return valve
4
8 9 10 11 27
6
18
3
19
Filter 14 13
Fig. 6 Filtration 4 22
Pos. Description 2
23
Pos. Description
Automatic control devices 1 Raw-water feed pump
To protect the pumps against dry running, fit the 2 Filter
system with flow or pressure control devices. 3 Low-pressure switch
4 Flowmeter
A pressure switch on the inlet side is sized in
5 Pressure gauge (raw water)
accordance with the estimated inlet pressure. At a
6 BMS hs pump with built-in non-return valve
pressure lower than 1 bar (14.5 psi), an alarm is given
7 Non-return valve (built into BMS hs)
and the pump will stop.
8 Pressure gauge (BMS hs outlet pressure)
The control devices ensure correct inlet pressure.
9 Vent
Flow switch cutting-in is adjusted for a minimum time 10 High-pressure switch
delay corresponding to the maximum starting 11 Pressure relief valve
frequency of the system. 12 Pressure gauge (BMS hp inlet pressure)
13 Pressure gauge (BMS hp outlet pressure)
Automatic safety devices 14 BMS hp pump
15 Flowmeter (high-pressure raw water)
The safety devices below must be built into the system 16 Pressure gauge (low-pressure raw water)
to protect the pump. See fig. 7. 17 Flowmeter (low-pressure raw water)
• Flow switch and/or low-pressure switch to ensure a 18 Membrane filter
minimum flow of water and lubricate the thrust 19 Permeate
bearing, shaft seal and pump bearings. 20 Cleaning flush valve
• Low-pressure switch on the booster system inlet 21 Pressure gauge (high-pressure concentrate)
sized in accordance with the estimated inlet 22 Pressure gauge (low-pressure concentrate)
pressure. At a pressure lower than 1 bar (14.5 psi), 23 Pressure exchanger
an alarm is given, and the pump will stop. 24 Concentrate valve
• High-pressure switch on the outlet pipe. The high- 25 Pressure gauge (fresh-water)
pressure switch will stop the pump at a set 26 Fresh-water flush pump
8
BMS
4
4. Grundfos BMS hs
Grundfos BMS hs
Operating limits
We recommend that you always keep the capacity of
Grundfos offers three different systems for reverse Note: If there is a risk of exceeding the maximum inlet
osmosis: or outlet pressure, we recommend that you install a
• Grundfos BMS hs safety valve.
• Grundfos BMST Note: Maximal permissible liquid temperature is 40 °C
• Grundfos BMSX. (104 °F). If you have an application for higher
temperature, contact Grundfos.
Standard pumps
BMS hs booster system
The following standard pumps are used for the BMS hs
booster system:
• SP 7-42
• SP 17-22
• SP 30-14
• SP 30-26
• SP 46-17
• SP 60-17.
Note: The pumps are supplied with non-return valves.
9
4 BMS
Construction
Modified standard submersible pumps are used for the
BMS hs booster systems. The pumps are centred in a
10
BMS
4
Frequency converter for PM motor Factory-set PM motor
Grundfos BMS hs
® The frequency converter is set by Grundfos to match
The Danfoss VLT AQUA Drive FC 202 is a user-
friendly, UL-approved and compact frequency the motor and ensure safe operation of the pump.
converter. The ramp-up and ramp-down times ensure safe
operation during startup, normal operation and
shutdown. See fig. 12.
rpm
3
1700
11
4 BMS
Pos. Description
• PROFIBUS DP V1 MCA 101 18 Main Menu
• DeviceNet MCA 104 19
Alarm Log, displays a list of current warnings, the last 10
alarms and the maintenance log
• PROFINET MCA 120
20 Reference (%)
• EtherNet/IP MCA 121 21 Power (kW)
• Modbus TCP MCA 122
Operating panel
The operating panel is easy to use and provides
instant, intuitive access to parameters and operating
data.
1
Status 1(1) 21
799RPM 7.83A 36.4kW
0.000
2
A 20
53.2%
5
Ca
ck
18
n
Ba
ce
l
6 C 17
Info
On OK
7 Warn. 16
8
TM07 441 1419
Alarm
9 15
D Hand Auto
on on Reset
14
10 11 12 13
Pos. Description
1 Speed (RPM)
2 Motor current
3 Frequency
4 Status
5 Quick Menu
6 Back
7 Indicator light (ON)
8 Indicator light, fault (yellow)
9 Indicator light, fault (red)
10 Hand on, starts the frequency converter in local control
Off, stops the motor but does not remove power from the
11
frequency converter
12 Auto on, sets the system in remote operating mode
Reset, resets the frequency converter after a fault has been
13
cleared
14 OK
15 Right
16 Info
17 Cancel
12
BMS
5
5. Grundfos BMS hp
Grundfos BMS hp
Operating limits
We recommend that you always keep the capacity of
the booster systems within the recommended flow rate
BMS hp
Recommended flow rate at 25 °C (77 °F)
Fig. 14 BMS hp pump Type [m3/h] US [gpm]
BMS hp 17-3, 17-5 and 17-7 10-26 44 - 114.5
Applications BMS hp 30-3, 30-5 and 30-7 19-45 83.7 - 198
BMS hp 46-2, 46-4 and 46-6A 28-72 123-317
The Grundfos BMS hp booster system is suitable for BMS hp 60-2, 60-4 and 60-6 37-90 163 - 396.3
industrial and water supply applications where the inlet BMS hp 77-2 and 77-3 47-120 207-528
pressure is high, up to 82.7 bar (1200 psi). BMS hp BMS hp 95-3 57-143 251-629
booster systems are used to increase the system BMS hp 125-2 75-187 330-823
pressure up to 82.7 bar (1200 psi). BMS hp 160-2 90-215 396-946
BMS hp 215-1 115-310 506-1364
The BMS hp booster system is the optimum solution
for applications requiring the following:
Recommended pressure
• pumps capable of coping with high system
Inlet pressure Outlet pressure
pressures
Type Min. Min. Max. Max. Max. Max.
• a minimum of maintenance. [bar] [psi] [bar] [psi] [bar] [psi]
BMS hp 17-3, 17-5
Typical applications and 17-7
1 14.5 80 1160 82.7 1200
BMS hp booster systems are suitable for the following BMS hp 30-3, 30-5
1 14.5 80 1160 82.7 1200
and 30-7
typical applications:
BMS hp 46-2, 46-4
1 14.5 80 1160 82.7 1200
• Water treatment where energy recovery devices and 46-6A
(ERD), like pressure exchangers are used, such as: BMS hp 60-2, 60-4
1 14.5 80 1160 82.7 1200
and 60-6
– reverse osmosis in domestic water supply BMS hp 77-3 1 14.5 80 1160 82.7 1200
systems BMS hp 95-3 1 14.5 80 1160 82.7 1200
– hospitals, laboratories as well as chemical, BMS hp 125-2 1 14.5 80 1160 82.7 1200
electronics and metal industries BMS hp 160-2AA 1 14.5 80 1160 82.7 1200
BMS hp 215-1 1 14.5 80 1160 82.7 1200
– ultra-filtration in chemical and galvanic industries
– painting workshops, metal and mineral industries. Note: If there is a risk of exceeding the maximum inlet
• Liquid transfer. or outlet pressure, we recommend that you install a
safety valve.
• Pressure boosting.
Note: Maximal permissible liquid temperature is 40 °C
• Closed circulation systems with a high static
(104 °F). If you have an application for higher
pressure.
temperature, contact Grundfos.
13
5 BMS
Asynchronous motor with integrated variable- We recommend Grundfos CUE frequency converters
frequency drive (Grundfos standard MG, MGE and or Danfoss VLT® AQUA Drive FC 202.
Siemens motors). MGE motors are fitted with integrated frequency drive.
Motor type
You can fit BMS hp with a totally enclosed, fan-cooled,
Operating conditions
2-pole Grundfos standard MG or MGE motor. The
motor has principal dimensions according to EN
Sound pressure level
standards and electrical tolerances according to EN The sound pressure level of BMS hp 6" booster
60034. systems is below 72 dB(A) and the sound pressure
3 to 22 kW (4 to 30 hp): E-pumps with three-phase level of BMS hp 8" booster systems is below 80 dB(A).
MGE motors.
Temperature
Grundfos MGE 100, MGE 132, MGE 160 and MGE
180 motors offer these features: Storage and transport temperature: -40 to +104 °C (-
• Three-phase mains connection. 40 to +104 °F)
• Three-phase, asynchronous squirrel-cage induction Operating temperature: -4 to +104 °C , up to 50 °C
motors designed to IEC, DIN and VDE guidelines (122 °F).
and standards. The motors incorporate a frequency Humidity
converter and PI controller. Relative humidity in accordance with IEC 60068-2-56:
• Used for continuously variable-speed control of lower than 90 % non-condensing.
Grundfos E-pumps.
Altitude
Note that motors without an integrated variable-
frequency drive require an external variable-frequency 0 to 4000 m, with derating of operating temperature of
drive to obtain duty points shown on the performance 0.6 °C per 100 m between 1000 and 4000 m.
curves.
Rated speed
Voltages 60 Hz: 3500 min-1.
• 3 x 380-480 V.
Enclosure class
• IP55 (IEC 34-5).
1700 3
TM06 1079 1614
1
4
3 seconds t [seconds]
14
BMS
6
Built-in
8 10 5
7 9
4
6 3
5
Pos. Description
Fig. 16 Example of BMS hs booster system 1 Raw-water feed pump
2 Pressure gauge (raw water)
Pos. Description 3 Filter
1 Raw-water feed pump 4 Low-pressure switch
2 Pressure gauge (raw water) 5 Flowmeter
3 Filter 6 BMS hp pump
4 Low-pressure switch 7 High-pressure switch
5 Flowmeter 8 Pressure gauge (BMS hp outlet pressure)
6 BMS hs pump with built-in non-return valve 9 Air vent
7 High-pressure switch 10 Pressure relief valve
8 Pressure gauge (BMS hs outlet pressure) 11 Pressure gauge (fresh-water pump)
9 Vent 12 Fresh-water flush pump*
10 Pressure relief valve * A fresh-water flush pump must be installed in applications for
11 Pressure gauge (fresh-water pump) seawater desalination or similar applications.
12 Fresh-water flush pump*
The function of a BMS hp booster system
* A fresh-water flush pump must be installed in applications for
seawater desalination or similar applications. The BMS hp pump creates the needed flow rate and
pressure in the system. The frequency converter
The function of a BMS hs booster system ensures low operating costs and safe ramp-up and
The BMS hs pump creates the needed flow rate and ramp-down. The factory-set ramp times prevent
pressure in the system. The frequency converter damage from water hammer.
ensures low operating costs and safe ramp-up and
ramp-down. The factory-set ramp times prevent
damage from water hammer.
15
7 BMS
5 10 9 8 5 6.1
4
12
3
3
Pos. Description
Pos. Description
1 Raw-water feed pump
1 Raw-water feed pump
2 Pressure gauge (raw water)
2 Pressure gauge (raw water)
3 Filter
3 Filter
4 Low-pressure switch
4 Low-pressure switch
5 Flowmeter
5 Flowmeter
6 BMT pump
6 BMS hs pump with built-in non-return valve
6.1 BMS hs pump
7 High-pressure switch
7 Pressure gauge (BMST outlet pressure)
8 Pressure gauge (BMS hs outlet pressure)
8 Flowmeter
9 Vent
9 Vent
10 Pressure relief valve
10 High-pressure switch
11 Membrane filter
11 Pressure relief valve
12 Permeate
12 Membrane filter
13 Pressure control valve
13 Permeate
14 Pressure gauge (fresh-water)
14 Pressure gauge (high-pressure concentrate)
15 Fresh-water flush pump
15 Pressure gauge (fresh-water)
16 Fresh-water flush pump
How does it work?
BMST systems enable performance equal to standard
The BMS hs pump creates the needed flow rate and
pressure through the membranes of the system. The centrifugal pumps while saving up to 35 % of the total
frequency converter ensures low operating costs and power consumption.
safe ramp-up and ramp-down. The factory-set ramp
times prevent damage from water hammer.
How does it work?
The BMS hs pump creates the needed flow rate and
pressure through the membranes of the system. 65 %
of the energy needed is generated by the BMS hs
pump, and the remaining 35 % is provided by the
Pelton turbine. The turbine is driven by the high-
pressure concentrate outlet. The BM pump driven by
the Pelton turbine increases the inlet pressure of the
BMS hs pump.
This makes it possible to save up to 35 % of the total
power consumption.
16
BMS
7
BMSX system How does it work?
19
14 13
3 12 15 20
21
5 16 17
4 22
2
23
TM05 9617 4213
24
25
1
26
Pos. Description
1 Raw-water feed pump
2 Filter
3 Low-pressure switch
4 Flowmeter
5 Pressure gauge (raw water)
6 BMS hs pump with built-in non-return valve
7 Non-return valve (built into BMS hs)
8 Pressure gauge (BMS hs outlet pressure)
9 Vent
10 High-pressure switch
11 Pressure relief valve
12 Pressure gauge (BMS hp inlet pressure)
13 Pressure gauge (BMS hp outlet pressure)
14 BMS hp pump
15 Flowmeter (high-pressure raw water)
16 Pressure gauge (low-pressure raw water)
17 Flowmeter (low-pressure raw water)
18 Membrane filter
19 Permeate
20 Cleaning flush valve
21 Pressure gauge (high-pressure concentrate)
22 Pressure gauge (low-pressure concentrate)
23 Pressure exchanger
24 Concentrate valve
25 Pressure gauge (fresh-water)
26 Fresh-water flush pump
27 Flowmeter
17
8 BMS
18
BMS
8
BMS hp booster system
BMS hp MG
Features
• Motor controlled by variable-frequency drive
• speed range of 1700-3500 rpm
• reduced system wear
• high inlet-pressure up to 82.7 bar (1200 psi).
Benefits
• Perfect process control
• easy-to-use selection tool
• small footprint
• low weight
• extreme durability and reliability
• easy integration in any water treatment system
• designed for high flow rate and pressure
• built-in check valve as option
• inlet and outlet pipes connected using Victaulic
couplings, style 77DX
• LSR/NSR pump bearings and seal rings
• Silicon carbide/carbon shaft seal.
BMS hp MGE
Features
• Motor controlled by variable-frequency drive
• speed range of 1700-3500 rpm
• factory-set ramp times
• extra functions I/O functionality
• data collection
• reduced system wear
• high inlet-pressure up to 82.7 bar (1200 psi).
Benefits
• Perfect process control
• remote control, monitoring and data collection of the
application and pump performance
• reduced installation and wiring costs
• easy-to-use selection tool
• small footprint
• low weight
• extreme durability and reliability
• easy integration in any water treatment system
• designed for high flow rate and pressure
• built-in check valve as option
• inlet and outlet pipes connected using Victaulic
couplings, style 77DX
• NBR/LSR pump bearings and seal rings
• Silicon carbide/carbon shaft seal.
19
9 BMS
9. Sizing
Sizing
Pos. Description
"Advanced Sizing" allows you to size pumps with a full range
1
of pump sizing parameters and options.
"Reverse Osmosis" is a new type of installation applicable to
2 commercial buildings, municipal water supply and industrial
plant service systems.
"Evaluation Criterion" allows you to sort and prioritise results
3
based on price, energy consumption or price + energy costs.
4 Default values and units of measurement.
20
BMS
9
Configure unit system settings
Sizing
You can choose between four types of unit systems
depending on your requirements:
SI units:
• Pressure: kpa
• Flow: m3/h
• Density: kg3/m3
US units:
• Pressure: psi
• Flow: US GPM
• Density: lb/ft3
Default units:
• Pressure: bar
• Flow: m3/h
• Density: kg3/m3
User defined units:
Use "User defined units" for customised and
personalised unit settings.
Select [Change settings].
21
9 BMS
Sizing
22
BMS
9
Filtering options
Sizing
Booster pump and pressure exchange safety margins The best solutions are automatically found using
can be set to over size the products. parallel operation for large capacities.
• Minimum input is 0 % which is also the default For example:
value. • permeate flow = 150 m3/h.
• Maximum value for the safety margin is 30 %. • Default value is set to 1.6.
23
9 BMS
Sizing results
Sizing
24
BMS
9
Product detail page
Sizing
This page consists of detailed technical information for
a system or product.
Pos. Description
1 The "View" panel
2 Technical information, related videos and documents tabs
3 Summary of the calculation for the chosen product
25
9 BMS
Print / PDF
Sizing
Pos. Description
26
BMS
10
Product range
BMS hs PM booster system factory supplied with frequency converter
Power P2 Max. speed
BMS hs booster Frequency converter Product number
[kW] [hp] [rpm]
BMS 17-22 HS-E-C-P-A 70 94 5500 FC-202P75K IP55 380-480V 99470789
BMS 17-22 HS-E-C-P-A 85 114 5500 FC-202P90K IP55 380-480V 99470792
BMS 17-22 HS-E-C-P-A 70 94 5000 FC-202P75K IP55 380-480V 99471122
BMS 17-22 HS-E-C-P-A 44 59 4500 FC-202P45K IP55 380-480V 99471131
BMS 17-22 HS-E-C-P-A 52 70 4500 FC-202P55K IP55 380-480V 99471148
BMS 30-14 HS-E-C-P-A 85 114 5500 FC-202P90K IP55 380-480V 99539742
BMS 30-26 HS-E-C-P-A 140 188 5500 FC202P160K IP54 380-480V 99471199
BMS 30-26 HS-E-C-P-A 160 215 5500 FC202P160K IP54 380-480V 99471213
BMS 30-26 HS-E-C-P-A 140 188 5000 FC202P160K IP54 380-480V 99471220
BMS 30-26 HS-E-C-P-A 100 134 4500 FC202P110K IP54 380-480V 99471222
BMS 46-17 HS-E-C-P-A 180 241 5500 FC202P200K IP54 380-480V 99471243
BMS 46-17 HS-E-C-P-A 140 188 5000 FC202P160K IP54 380-480V 99471246
BMS 46-17 HS-E-C-P-A 160 215 5000 FC202P160K IP54 380-480V 99471248
BMS 60-17 HS-E-C-P-A 180 241 5000 FC202P200K IP54 380-480V 99471276
27
10 BMS
[kW] [hp] IN [A] η [%] [mm] [in] Net Gross [m3] R-version
BMS 17-3 HP 3 4.0 6.8 - 5.4 64 1281.0 50.4 96.1 186.1 0.962 98872087
BMS 17-5 HP 5.5 7.5 10.6 - 9.3 66 1458.0 57.4 96.1 186.1 0.155 98872088
BMS 17-7 HP 7.5 10.0 14.2 - 12.0 67 1567.0 61.7 135.2 225.2 0.155 98872090
BMS 30-3 HP 5.5 7.5 10.6 - 9.3 66 1432.0 56.4 119.9 209.9 0.152 98872101
BMS 30-5 HP 7.5 10.0 14.2 - 12.0 68 1624.0 63.9 136.1 226.1 0.160 98872102
BMS 30-7 HP 11 15.0 20.8 - 17.2 68 2018.0 79.4 189.3 279.3 0.270 98872103
BMS 46-2 HP 5.5 7.5 10.6 - 9.3 63 1382.0 54.4 118.5 208.5 0.148 98872104
BMS 46-4 HP 11 15.0 20.8 - 17.2 66 1798.0 70.8 183.4 273.4 0.243 98872105
BMS 46-6A HP 15 20.0 28.0 - 22.4 67 2024.0 79.7 202.7 292.7 0.271 98872106
BMS 60-2 HP 7.5 10.0 14.2 - 12.0 60 1370.0 53.9 128.7 218.7 0.137 98872107
BMS 60-4 HP 11 15.0 20.8 - 17.2 66 1798.0 70.8 183.3 273.3 0.243 98872109
BMS 60-6 HP 18.5 25.0 34.5 - 28.0 69 2068.0 81.4 215.9 305.9 0.277 98872110
[kW] [hp] IN [A] η [%] [mm] [in] Net Gross [m3] R-version
BMS 77-2A HP 11.0 15.0 20.8 - 17.2 64 1857.0 73.1 225.0 325.0 0.250 98872111
BMS 77-3 HP 18.5 25.0 34.5 - 28.0 70 2029.0 79.9 256.0 356.0 0.272 98872112
BMS 95-2 HP 15.0 20.0 28.0 - 22.4 69 1857.0 73.1 234.0 334.0 0.250 98872113
BMS 95-3 HP 22.0 30.0 40.0 - 32.5 71 2055.0 80.9 270.0 370.0 0.311 98872116
BMS 125-1 HP 18.5 25.0 34.5 - 28.0 68 1807.0 71.1 255.0 355.0 0.244 98872117
BMS 125-2AA HP 22.0 30.0 40.0 - 32.5 69 1988.0 78.3 281.0 381.0 0.302 98872119
BMS 160-1A HP 15.0 20.0 28.0 - 22.4 62 1763.0 69.4 208.0 308.0 0.239 98872120
BMS 160-1 HP 22.0 30.0 40.0 - 32.5 68 1833.0 72.2 271.0 371.0 0.280 98872121
BMS 160-2AA HP 30.0 41.0 56.0 - 50.0 76 2022.0 79.6 300.0 390.0 0.514 98494526
BMS 215-1A HP 30.0 41.0 56.0 - 50.0 78 2005.0 78.9 300.0 390.0 0.510 98494527
BMS 215-1 HP 37.0 50.0 68.0 - 61.0 79 2030.0 79.9 346.0 436.0 0.516 98494528
28
BMS
10
BMS hp MGE booster system 6"
Product range
Motor output Rated Efficiency Length Weight Product
Ship. vol.
Type [P2] current total [L] [kg] number
[kW] [hp] IN [A] η [%] [mm] [in] Net Gross [m3] R-version
BMS 17-3 HP 3 4 6.2 - 5.00 64 1281 50.4 101.4 191.4 0.399 98494496
BMS 17-5 HP 5.5 7.5 11.0 - 8.80 66 1458 57.4 103.0 192.8 0.399 98494497
BMS 17-7 HP 7.5 10 14.8 - 11.6 67 1567 61.7 145.6 235.6 0.234 98494498
BMS 30-3 HP 5.5 7.5 11.0 - 8.80 68 1432 56.4 126.6 216.6 0.399 98494499
BMS 30-5 HP 7.5 10.0 14.8 - 11.6 68 1624 63.9 146.5 236.6 0.399 98494500
BMS 30-7 HP 11.0 15 22.5 - 18.8 69 2018 79.4 219.9 309.8 0.441 98494511
BMS 46-2 HP 5.5 7.5 11.0 - 8.80 69 1382 54.4 125.0 215.0 0.399 98494512
BMS 46-4 HP 11.0 15 22.5 - 18.8 70 1798 70.8 213.8 303.8 0.399 98494513
BMS 46-6A HP 15 20 30.0 - 26.0 71 2024 79.7 235 325 0.442 98494514
BMS 60-2 HP 7.5 10 14.8 - 11.6 70 1370 53.9 139.0 229.1 0.399 98494515
BMS 60-4 HP 11.0 15.0 22.5 - 18.8 71 1798 70.8 213.7 303.7 0.399 98494516
BMS 60-6 HP 18.5 25.0 29.9 - 35.7 72 2068 81.4 248.3 338.3 0.500 98494517
[kW] [hp] IN [A] η [%] [mm] [in] Net Gross [m3] R-version
BMS 77-2A HP 11 15 22.5 - 18.8 70 1.822 71.7 153 243 0.388 98494518
BMS 77-3 HP 18.5 25 37-31 71 1.994 78.5 180 270 0.425 98494519
BMS 95-2 HP 15 20 30-26 72 1.822 71.7 167 257 0.388 98494520
BMS 95-3 HP 22 30 44-35 72 2.020 79.5 197 287 0.435 98494521
BMS 125-1 HP 18.5 25 37-31 74 1.771 69.7 180 270 0.378 98494522
BMS 125-2AA HP 22 30 44-35 74 1.952 76.9 197 287 0.42 98494523
BMS 160-1A HP 15 20 30-26 74 1.727 67.9 167 257 0.368 98494524
BMS 160-1 HP 22 30 44-35 75 1.797 70.7 197 287 0.387 98494525
29
11
Performance curves
1000 700
650
900
600
800 70 kW 85 kW
550
44 kW
700 500
500 350
300
400
52 kW 5000 rpm
250
300 200
200 150
0 0
0 4 8 12 16 20 24 28 32 36 Q [m³/h]
P2 Eta
[kW] [%]
140 70
120 60
5500 rpm
5000 rpm
60 30
4500 rpm
40 20
20 10
0 0
TM05 8114 5115
0 4 8 12 16 20 24 28 32 36 Q [m³/h]
30
11
Performance curves
BMS hs PM, 30-14
p H
[psi] [m]
600
BMShs PM 30-14
ISO 9906:2012 Grade 3B
800
550
700 500
450
600
400
500 350
300
400
250
300
200
150
200
100
5500 rpm
100
50 5000 rpm
0 0
0 10 20 30 40 50 60 70 80 90Q [m³/h]
P2 Eta
[kW] [%]
160 80
140 70
120 60
100 50
80 5500 rpm 40
60 30
5500 rpm
40 20
20 10
0 0
TM07 4352 1319
0 10 20 30 40 50 60 70 80 90Q [m³/h]
31
11
Performance curves
200 150
4000 rpm
100
100
50
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 Q [m³/h]
P2 Eta
[kW] [%]
280 70
240 60
5500 rpm
200 50
5000 rpm
4500 rpm
160 5500 rpm 40
80 4500 rpm 20
40 10
0 0
TM05 8237 5115
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 Q [m³/h]
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320Q [US GPM]
32
11
Performance curves
BMS hs PM, 46-17
p H
[psi] [m]
800 BMShs PM 46-17
1100 ISO 9906:2012 3B
750
1000 700
650
900
600
180 kW
800
550
140 kW
700 500
450
600
400
160 kW
500 350
5500 rpm
300
400
250
140 kW
300
200
5000 rpm
200 150 4500 rpm
100
100
50
0 10 20 30 40 50 60 70 80 90 100 Q [m³/h]
P2 Eta
[kW] [%]
280 70
5500 rpm
240 60
5000 rpm
200 50
5500 rpm
160 40
5000 rpm
120 30
80 20
40 10
0 0
TM05 8238 5115
0 10 20 30 40 50 60 70 80 90 100 Q [m³/h]
0 50 100 150 200 250 300 350 400 450Q [US GPM]
33
11
Performance curves
650
900
600
800
550
180 kW
700 500
450
600
400
500 350
150
200
100
100
50
0 10 20 30 40 50 60 70 80 90 100 110 Q [m³/h]
P2 Eta
[kW] [%]
320 80
5000 rpm
280 70
240 60
200 50
120 30
80 20
40 10
0 0
TM05 8239 5115
0 50 100 150 200 250 300 350 400 450 Q [US GPM]
34
11
Performance curves
BMS hs AC, 7-42
p H
[psi] [m]
750 BMShs AC 7-42
ISO 9906:2012 Grade 3B
1000 700
650
900
600
800
550
30 kW
700 500
450
600
400
500 350
300
400
250
300
200
5000 rpm
150
200
35 70
30 60
5000 rpm
25 50
20 40
15 30
5000 rpm
10 20
5 10
0 0
TM07 4351 1319
0 2 4 6 8 10 12 14 16 18Q [m³/h]
0 10 20 30 40 50 60 70 Q [US GPM]
35
11
Performance curves
N:
N:
N:
N: USP
N:
USP
USP
4>PñK@
3 (WD
>N:@ >@
USP
USP
USP
USP
USP
USP
TM06 5600 5115
4>PñK@
36
11
Performance curves
BMS hs AC, 30-14
S +
>SVL@ >P@
%06KV$&
,62%
N:
USP
4>PñK@
3 (WD
>N:@ >@
USP
USP
TM06 5601 5115
4>PñK@
37
11
Performance curves
N:
N:
N:
N:
N:
USP
USP
USP
USP
4>PñK@
3 (WD
>N:@ >@
USP
USP
USP USP
USP
USP
USP
USP
TM06 5602 5115
4>PñK@
38
11
Performance curves
BMS hs AC, 46-17
S +
>SVL@ >P@
%06KV$&
,62%
N:
N:
N
:
USP
USP
USP
4>PñK@
3 (WD
>N:@ >@
USP
USP
USP
USP
USP
USP
TM06 5603 5115
39
11
Performance curves
N:
USP
USP
4>PñK@
3 (WD
>N:@ >@
USP
USP
TM06 5604 5115
4>86*30@
40
11
Performance curves
BMS hp, 17-3, 17-5 and 17-7
S +
>SVL@ >P@
%06KS
,62%
4>PñK@
4>86*30@
3 3 (WD
>KS@ >N:@ >@
(WD
3
TM06 0725 0814
4>PñK@
41
11
Performance curves
4>PñK@
TM06 0726 0814
4>PñK@
42
11
Performance curves
BMS hp, 46-2, 46-4 and 46-6A
S +
>SVL@ >P@
%06KS
,62%
4>PñK@
4>PñK@
43
11
Performance curves
4>PñK@
4>PñK@
44
11
Performance curves
BMS hp, 77-2A and 77-3
S +
>SVL@ >P@
%06KS
,62%
$
4>PñK@
(WD
3
TM06 2412 4314
4>PñK@
45
11
Performance curves
4>PñK@
4>86*30@
3 3 (WD
>KS@ >N:@ >@
3
(WD
TM06 2412 4314
4>PñK@
46
11
Performance curves
BMS hp, 125-1 and 125-2AA
S +
>SVL@ >P@
%06KS
,62%
$$
4>PñK@
TM06 2414 4314
4>PñK@
47
11
Performance curves
$
4>PñK@
4>86*30@
3 3 (WD
>KS@ >N:@ >@
3
(WD
TM06 2415 4314
4>PñK@
48
11
Performance curves
BMS hp, 215-1A and 215-1
S +
>SVL@ >P@
%06KS
,62%
$
4>PñK@
4>86*30@
3 3 (WD
>KS@ >N:@ >@
(WD
3
TM06 2416 4314
4>PñK@
49
12 BMS
Motor Motor
Dimension Dimension Dimension Dimension Dimension Width
Power P2 dimension dimension Weight*
BMS hs Product [H] [I] [J] [K] [L] [W]
[G] [HD]
booster type number
[kW] [hp] [mm] [inch] [mm] [inch] [mm] [inch] [mm] [inch] [mm] [inch] [mm] [inch] [mm] [inch] [mm] [inch] [kg]
99470789 70 94 318 12.5 540 21.3 308.5 12.1 1779 70 140 5.5 13 0.5 400 15.7 378 14.9 262
99470792 85 114 318 12.5 540 21.3 308.5 12.1 1779 70 140 5.5 13 0.5 400 15.7 378 14.9 262
BMS 17-22,
99471122 70 94 318 12.5 540 21.3 308.5 12.1 1779 70 140 5.5 13 0.5 400 15.7 378 14.9 262
HS-E-C-P-A
99471131 44 59 318 12.5 540 21.3 308.5 12.1 1779 70 140 5.5 13 0.5 400 15.7 378 14.9 247
99471148 52 70 318 12.5 540 21.3 308.5 12.1 1779 70 140 5.5 13 0.5 400 15.7 378 14.9 262
BMS 30-14,
99539742 85 114 318 12.5 540 21.3 308.5 12.1 1792 70.5 140 5.5 13 0.5 400 15.7 378 14.9 348
HS-E-C-P-A
99471199 140 188 356 14 769 30.3 308.5 12.1 2966 116.8 140 5.5 13 0.5 400 15.7 420 16.5 494
BMS 30-26, 99471213 160 215 356 14 769 30.3 308.5 12.1 2966 116.8 140 5.5 13 0.5 400 15.7 420 16.5 494
HS-E-C-P-A 99471220 140 188 356 14 769 30.3 308.5 12.1 2966 116.8 140 5.5 13 0.5 400 15.7 420 16.5 494
99471222 100 134 356 14 769 30.3 308.5 12.1 2966 116.8 140 5.5 13 0.5 400 15.7 420 16.5 494
99471243 180 241 356 14 769 30.3 308.5 12.1 2391 94.1 140 5.5 13 0.5 400 15.7 420 16.5 486
BMS 46-17,
99471246 140 188 356 14 769 30.3 308.5 12.1 2391 94.1 140 5.5 13 0.5 400 15.7 420 16.5 486
HS-E-C-P-A
99471248 160 215 356 14 769 30.3 308.5 12.1 2391 94.1 140 5.5 13 0.5 400 15.7 420 16.5 486
BMS 60-17,
99471276 180 241 356 14 769 30.3 308.5 12.1 2391 94.1 140 5.5 13 0.5 400 15.7 420 16.5 486
HS-E-C-P-A
Dimensional sketch
*
TM05 9244 3613
50
BMS
12
Frequency converter for PM motor
Service connector
Use the service connector to ensure easy access for
maintenance. The length of the service connector is
312 mm.
TM05 9766 4413
51
12 BMS
Motor
Dimension Dimension Dimension Dimension Dimension Width
Power P2 dimension Weight*
BMS hs Product [H] [I] [J] [K] [L] [W]
[HD]
booster type number
[kW] [hp] [mm] [inch] [mm] [inch] [mm] [inch] [mm] [inch] [mm] [inch] [mm] [inch] [mm] [inch] [kg]
BMS 7-42
99277174 30 40.2 565 22.2 308.5 12.1 2424 95.4 140 5.5 13 0.5 400 15.7 396 15.6 313
HS-B-C-P-A
99022832 52 69.7 565 22.2 308.5 12.1 1779 69.7 140 5.5 13 0.5 400 15.7 396 15.6 389
BMS 17-22
99022843 70 93.9 683 26.9 308.5 12.1 1801 70.9 140 5.5 13 0.5 400 15.7 431 17.7 437
HS-B-C-P-A
99022844 85 114 683 26.9 308.5 12.1 1801 70.9 140 5.5 13 0.5 400 15.7 449 17.7 442
BMS 30-14
99022845 85 114 683 26.9 308.5 12.1 1814 71.4 140 5.5 13 0.5 400 15.7 449 17.7 440
HS-B-C-P-A
99022846 120 160.9 683 26.9 308.5 12.1 2966 116.8 140 5.5 13 0.5 400 15.7 449 17.7 511
BMS 30-26
99022847 140 187.7 683 26.9 308.5 12.1 2966 116.8 140 5.5 13 0.5 400 15.7 449 17.7 606
HS-B-C-P-A
99022848 160 214.6 802 31.6 308.5 12.1 3016 118.7 140 5.5 13 0.5 400 15.7 497 19.6 643
BMS 46-17 99022849 160 214.6 802 31.6 308.5 12.1 2441 96.1 140 5.5 13 0.5 400 15.7 497 19.6 636
HS-B-C-P-A 99059893 180 241.4 802 31.6 308.5 12.1 2441 96.1 140 5.5 13 0.5 400 15.7 497 19.6 646
BMS 60-17
99022850 180 241.4 802 31.6 308.5 12.1 2441 96.1 140 5.5 13 0.5 400 15.7 497 19.6 646
HS-B-C-P-A
Dimensional sketch
52
BMS
12
BMS hp MG booster system 6"
[mm] [inch] [mm] [inch] [mm] [inch] [mm] [inch] [mm] [inch] [mm] [inch]
BMS 17-3 HP-A-C-P-A 98872087 170 6.7 139.0 5.5 100 3.9 168.3 6.6 1281 50.4 140 5.5
BMS 17-5 HP-A-C-P-A 98872088 170 6.7 139.0 5.5 132 5.2 168.3 6.6 1458 57.4 140 5.5
BMS 17-7 HP-A-C-P-A 98872090 170 6.7 139.0 5.5 132 5.2 168.3 6.6 1567 61.7 140 5.5
BMS 30-3 HP-A-C-P-A 98872101 170 6.7 139.0 5.5 132 5.2 168.3 6.6 1444 56.4 140 5.5
BMS 30-5 HP-A-C-P-A 98872102 170 6.7 139.0 5.5 132 5.2 168.3 6.6 1624 63.9 140 5.5
BMS 30-7 HP-A-C-P-A 98872103 170 6.7 139.0 5.5 160 6.3 168.3 6.6 2018 79.4 210 8.3
BMS 46-2 HP-A-C-P-A 98872104 170 6.7 139.0 5.5 132 5.2 168.3 6.6 1382 54.4 140 5.5
BMS 46-4 HP-A-C-P-A 98872105 170 6.7 139.0 5.5 160 6.3 168.3 6.6 1798 70.8 210 8.3
BMS 46-6A HP-A-C-P-A 98872106 170 6.7 139.0 5.5 160 6.3 168.3 6.6 2024 79.7 210 8.3
BMS 60 -2 HP-A-C-P-A 98872107 170 6.7 139.0 5.5 132 5.2 168.3 6.6 1370 53.9 140 5.5
BMS 60 -4 HP-A-C-P-A 98872109 170 6.7 139.0 5.5 160 6.3 168.3 6.6 1798 70.8 210 8.3
BMS 60 -6 HP-A-C-P-A 98872110 170 6.7 139.0 5.5 160 6.3 168.3 6.6 2068 81.4 254 10.0
Dimensional sketch
*
53
12 BMS
[mm] [inch] [mm] [inch] [mm] [inch] [mm] [inch] [mm] [inch] [mm] [inch]
BMS 77 -2A HP-A-C-P-A 98872111 275 10.8 206.5 8.1 160 6.3 273.0 10.7 1857 73.1 210 8.3
BMS 77 -3 HP-A-C-P-A 98872112 275 10.8 206.5 8.1 160 6.3 273.0 10.7 2029 79.9 254 10.0
BMS 95 -2 HP-A-C-P-A 98872113 275 10.8 206.5 8.1 160 6.3 273.0 10.7 1857 73.1 210 8.3
BMS 95 -3 HP-A-C-P-A 98872116 275 10.8 206.5 8.1 180 7.1 273.0 10.7 2055 80.9 241 9.5
BMS 125 -1 HP-A-C-P-A 98872117 275 10.8 206.5 8.1 160 6.3 273.0 10.7 1807 71.1 254 10.0
BMS 125 -2AA HP-A-C-P-A 98872119 275 10.8 206.5 8.1 180 7.1 273.0 10.7 1988 78.3 241 9.5
BMS 160 -1A HP-A-C-P-A 98872120 275 10.8 206.5 8.1 160 6.3 273.0 10.7 1763 69.4 210 8.3
BMS 160 -1 HP-A-C-P-A 98872121 275 10.8 206.5 8.1 180 7.1 273.0 10.7 1833 72.2 241 9.5
BMS 160 -2AA HP-A-C-P-A 98494526 275 10.8 206.5 8.1 200 7.9 273.0 10.7 2058 81.0 305 12.0
BMS 215 -1A HP-A-C-P-A 98494527 275 10.8 206.5 8.1 200 7.9 273.0 10.7 2041 80.4 305 12.0
BMS 215 -1 HP-A-C-P-A 98494528 275 10.8 206.5 8.1 200 7.9 273.0 10.7 2066 81.3 305 12.0
Dimensional sketch
54
BMS
12
BMS hp MGE booster system 6"
Dimensional sketch
*
55
12 BMS
[mm] [inch] [mm] [inch] [mm] [inch] [mm] [inch] [mm] [inch] [mm] [inch]
BMS 77 -2A HP-C-C-P-A 98494518 275 10.8 206.5 8.1 160 6.3 273 10.7 1792 72.9 210 8.3
BMS 77 -3 HP-C-C-P-A 98494519 275 10.8 206.5 8.1 160 6.3 273 10.7 2029 79.7 254 9.9
BMS 95 -2 HP-C-C-P-A 98494520 275 10.8 206.5 8.1 160 6.3 273 10.7 1857 72.9 210 8.3
BMS 95 -3 HP-C-C-P-A 98494521 275 10.8 206.5 8.1 180 7.1 273 10.7 2055 80.7 241 9.5
BMS 125 -1 HP-C-C-P-A 98494522 275 10.8 206.5 8.1 160 6.3 273 10.7 1807 70.9 254 9.9
BMS 125 -2AA HP-C-C-P-A 98494523 275 10.8 206.5 8.1 180 7.1 273 10.7 1988 78.1 241 9.5
BMS 160 -1A HP-C-C-P-A 98494524 275 10.8 206.5 8.1 160 6.3 273 10.7 1763 69.2 210 8.3
BMS 160 -1 HP-C-C-P-A 98494525 275 10.8 206.5 8.1 180 7.1 273 10.7 1833 72.0 241 9.5
Dimensional sketch
56
BMS
13
Technical data
Material specification for BMS hs and BMS hp pump
R-version
Pos. Component Materials 24
DIN AISI PREN
1 Top chamber Stainless steel 1.4539 904L 34
2 Top bearing
Stainless steel/NBR 1.4539 904L 34
3 Bearing
23
4 Neck ring NBR/PPS - - -
5 Intermediate bearing NBR/LSR - - - 21
6 Spacing washer for stop ring Carbon/graphite, PTFE - 904L 34 1
2
4 13
8 Chamber Stainless steel 1.4539 904L 34 20
5
10 8
10 Nut for split cone Stainless steel 1.4539 904L 34 12 3
16
57
13 BMS
R-version
Pos. Component Materials*
DIN AISI PREN
1 Shaft with thrust bearing for BMS Stainless steel/ceramic 1.4462/1.4539 SAF 2205/904L 34
2 Bearing NBR - - -
3 Housing for thrust bearing Super duplex stainless steel* 1.4410 SAF 2507 43
4 Thrust bearing CPL Stainless steel/carbon 1.4547/1.4462/1.4539 254SMO/SAF 2205/904L 43/34/34
5 Pin Super duplex stainless steel* 1.4410 SAF 2507 43
6 Housing for shaft seal Super duplex stainless steel* 1.4410 SAF 2507 43
7 Housing for bell, GG-RV Cast iron GG25 0.6025 - -
8 Coupling spline for BMS 1.4462 - -
9 Shaft bushing D55 CK45 CK45 1045 -
10 Axial bearing Acoflon 214G - - -
11 Shaft seal Roten SGR5 Ceramic/silicon carbide - - -
* The super duplex material is used in areas with stagnant water to reduce the risk of crevice corrosion.
58
BMS
14
14. Accessories
Accessories
CUE frequency converter
Grundfos CUE is a series of external frequency
converters designed for speed control of a wide range
of Grundfos pumps.
When CUE is installed, the motor requires no further
motor protection.
CUE offers quick and easy setup and commissioning
compared to a standard frequency converter because
of the startup guide. Simply key in application-specific
variables such as motor data, pump family, control
function (e.g. constant pressure), sensor type, and
setpoint, and CUE will automatically set all necessary
parameters.
CUE enables gentle pumping and thereby protects the
water reservoir and the rest of the distribution system,
as water hammer can be avoided by adjusting ramp
times up and down.
Overview of the CUE range
Power range
Supply voltage [kW]
[V]
0.55 0.75 1.1 7.5 11 45 250
GrA4404
3 x 525-690
3 x 525-600
3 x 380-500 Fig. 38 The CUE range
3 x 200-240
1 x 200-240 Functions
CUE is available in two enclosure classes: CUE has a wide range of pump-specific functions,
• IP20/21 such as
• IP54/55. • constant pressure
Note: The maximum CUE frequency is 120 Hz. • constant level
• constant flow rate
RFI filters
• constant temperature
To meet the EMC requirements, CUE comes with the
following types of built-in radio frequency interference • constant curve.
filter (RFI). CUE features
Typical shaft • Startup guide
Voltage RFI filter
[V]
power, P2
type
Application CUE incorporates an innovative startup guide for
[kW] the general setting of CUE including the setting of
1 x 200-240 1.1 - 7.5 C1 the correct direction of rotation. The startup guide is
3 x 200-240 0.75 - 45 C1 Domestic started the first time when CUE is connected to the
0.55 - 90 C1
3 x 380-500 power supply.
110-250 C2 Domestic/industry
3 x 525-600 0.75 - 7.5 C3 • Check of direction of rotation.
Industry
3 x 525-690 11-25 C3 • Duty/standby operation.
• Dry-running protection.
• Low-flow stop function.
59
14 BMS
CUE incorporates various inputs and outputs: You can use the following sensors in connection with
• one RS-485 GENIbus connection CUE. All sensors are with 4-20 mA output signal:
• one analog input, 0-10 V, 0/4-20 mA • pressure sensors, up to 25 bar
– external setpoint • temperature sensors
• one analog input, 0/4-20 mA • differential-pressure sensors
– sensor input, feedback sensor • differential-temperature sensors
• one analog output, 0-20 mA • flowmeters
• four digital inputs • potentiometer box for external setpoint setting.
– start/stop and three programmable inputs Gateways
• two signal relays (C/NO/NC) CUE has a standard RS-485 GENIbus interface.
– programmable. Gateways to convert to other bus standards are
available as accessories.
Accessories for CUE
The CIU family (CIU = Communication Interface Units)
Grundfos offers various accessories for CUE.
can convert from GENIbus to the most common
MCB 114 sensor input module fieldbuses in the world:
MCB 114 offers additional analog inputs for CUE: • CIU 100 converts from GENIbus to LonWorks.
• one analog input, 0/4-20 mA • CIU 150 converts from GENIbus to Profibus DP.
• two inputs for Pt100 and Pt1000 temperature • CIU 200 converts from GENIbus to Modbus RTU.
sensors. • CIU 250 is a GSM modem which can send SMS
Output filters messages in case of alarms, etc.
Output filters are used primarily to protect the motor Control MPC
against overvoltage and increased operating Control MPC, a multipump control system for the
temperature. However, you can also use output filters control of parallel-connected CUE pump solutions.
to reduce acoustic noise from the motor.
Use of output filters
Grundfos offers two types of output filter as
accessories for CUE: The table below shows in which cases an output filter
is required. From the table, you can see if a filter is
• dU/dt filters
required, and which type to use.
• sine-wave filters.
The selection depends on these factors:
Floor-mounting option • pump type
CUE is as standard installed on the wall. You can also • motor cable length
install the enclosures D1 and D2 on the floor on a • the required reduction of acoustic noise from the
pedestal designed for that purpose. motor.
For information about enclosures, see the product-
specific documentation for CUE. Typical shaft Sine-wave
Pump type dU/dt filter
power P2 filter
IP21/NEMA1 option SP with 380 V motor Up to 7.5 kW - 0-300 m
and up 11 kW and up 0-150 m 150-300 m
You can upgrade an IP20 enclosure to IP21/NEMA1 by
using the IP21/NEMA1 option. The power terminals The lengths stated apply to the motor cable.
(mains and motor) will be covered.
60
BMS
14
Cables used in CUE installations CUE is the right choice of frequency converter in SP
Accessories
Note: When CUE is installed in connection with SP installations as it meets all basic issues. CUE has a
pumps, we distinguish between two types of pre-installed startup guide that takes the installer
installation: through all the necessary settings.
• installation in EMC-insensitive sites. See fig. 39. The table below shows the different issues to be
considered when using frequency converters in SP
• installation in EMC-sensitive sites. See fig. 40.
installations.
The two types of installation are different when it
comes to the use of screened cable. Issues to be considered Explanation
Note: Drop cables are always unscreened.
Lubricate the journal bearings in
Ramp (up and down):
order to limit wear and
Maximum 3 seconds.
CUE Filter overheating of windings.
Overheating of the motor => low
Use temperature monitoring by Pt
insulation resistance => sensitive
sensor.
to voltage peaks.
Reduce peak voltages (maximum Never exceed peak voltages of
Mains cable, Screened Drop cable, 800 V peaks). 850 V at motor leads.
unscreened cable
cable unscreened
For MS and MMS, we recommend
that you use motors with 10 %
CUE with output filter is a safe
extra in given duty point.
solution.
For MMS, always use motors
TM04 4296 1109 (PE2-PA-wound).
Cables act as an amplifier =>
Remember output filter.
measure peaks at the motor.
Time between switches is an
expression of losses, so in the
Limit the rise time (dU/dt) to a
future, we might have to exceed
Fig. 39 Example of installation in EMC-insensitive sites maximum of 1000 V/μs.
the limit of 1000 V/μs.
Determined by the equipment in
The solution is not higher
CUE.
insulation of the motor, but filter in
the output from CUE.
CUE Filter
Minimum 30 Hz.
Too low speed => no lubrication
Use a 60 Hz motor for larger
of journal bearings.
range.
Size the CUE in respect of the
Mains cable, Screened Screened Can end up with a too small CUE.
current, not the power output.
unscreened cable
cable cable Size cooling provision for stator
Consider a flow minimum along
tube at duty point with lowest flow
the stator housing.
rate.
Connection box Ensure that the pump is used Focus on the outlet pressure and
TM04 4295 1109
61
14 BMS
BMS hp
Accessories
62
BMS
15
http://product-selection.grundfos.com
This drop-down menu enables you to set the "REPLACEMENT" enables you to find a
search function to "Products" or "Literature". replacement product. Search results will
include information on the following:
63
ECM: 1258822
98567333 0419
GRUNDFOS A/S
www.grundfos.com
Telephone: +45 87 50 14 00
DK-8850 Bjerringbro . Denmark
Trademarks displayed in this material, including but not limited to Grundfos, the Grundfos logo and “be think innovate” are registered trademarks owned by The Grundfos Group. All rights reserved. © 2019 Grundfos Holding A/S, all rights reserved.