Professional Documents
Culture Documents
f = 0.75 9.3.2.3
Vu = qs B ( L/2 - a/2 - d )42.207202133
=
fVn = f 0.17 B d = 257.90038035 > Vu ….. safe Eq. (11-3)
Vu = qs L ( B/2 - b/2 - d )42.207202133
=
fVn = f 0.17 L d = 257.90038035 > Vu ….. safe Eq. (11-3)
Check of two way action
bo = 2 (a + b + 2d)2.516
β=a/b 1
40 interior column
0.17 (1 +2/β) = 0.51 Eq. (11-31)
fVn
bo d 0.33
[
= the minimum of 0.083 (αs d / bo) + 2= 0.43
= 0.33 (governs)
Eq. (11-32)
Eq. (11-33)
Vu = qs (LB - (a + d) (b + d))192.5395
fVn = f * 0.33 bo d =839.72364 > Vu ….. safe
Determination of footing reinforcement
Long direction
Mu = qs B ( L - a )² /8 28.034304
= 15.4.2
Mu
Rn = = 0.19185
f B d²
0.85 f'c Use minimum reinforcement
rreq =
fy
[ ] = 0.00046
As = r B d = 888.3
5 16 (As = 1004.8
Bars spacing = 333.5 < 450 mm…...safe 10.5.4
Short direction
Mu = qs L ( B - b )² /828.034304
= 15.4.2
Mu
Rn = = 0.21197
f L d²
0.85 f'c
rreq =
fy
[ ]
= 0.00051
fy ψt ψe ψs
Ld = [
1.1 λ
*
(Cb + Ktr)/db
] db Eq. (12-1)
= 25 >2 take it = 2
fPnb =1670.76
Bearing strengrh of column
In footing
Ldc = 0.24 fy / λ db = 393.48291 (governs) 12.3.2
Ldc minmum = 0.043 fy db288.96 =
L req = Kr Ldc = 293.70241 12.3.3 ( a )
Lavailable = h - Cc - ØL - ØS - Ødowel = 297 > Ldc……safe
In column
dowels compression splice
0 Ls = 0.071 fy db = 477.12 > 300mm……… safe 12.16.1
1 Ls = (0.13 fy - 24 ) db =
489.6 > 300mm……… safe
0 Ls = 1.33Ls 634.5696 12.16.1
column bars development
Ldc = 0.24 fy / λ db = 393.48291 (governs) 12.3.2
Ldc minmum = 0.043 fy db288.96
=
L req = the larger of dowels splice and column bars development
634.5696
=
FINAL RESULTS
Dimensions Reinforcement
L (m) B (m) h (m) Long steel Short steel
1.5 1.5 0.42 5 16 5 16