You are on page 1of 9

Mid Western Irrigation Development Division No 1

Tulsipur, Dang

Bill of Quantity (Payable)

Name of the project : Kanjawar Lift Irrigation Sub Project


Location : Kanjawar, Duruwa VDC-1

S.N. Description of work Units Quantity Rate (NRs) Amount (NRs) Remarks

1 #REF!
### #REF! #REF! #REF! #REF! #REF!
### #REF! #REF! #REF! #REF! #REF!
### #REF! #REF! #REF! #REF!
### #REF! #REF! #REF! #REF!
### #REF! #REF! #REF! #REF! #REF!
Total #REF!

Signed and Sealed On Behalf of Water User Association Signed and Sealed On Behalf of MWIDD No 1, Dang

Jhuplal Budathoki Shiv Kumar Basnet


Chairman, WUA Division Chief
Chharkata Babai Lift Irrigation System Water Users Association Mid Western Irrigation Development Division No 1, Tulsipur, Dang
Mid Western Irrigation Development Division No 1, Dang

Name of Sub-project: Kanjawar Lift Irrigation System


Job: Design of Pumping system and Selection of Pump

Source Level 631.00 m


Delivery Level (Canal Bed) 641.80 m
Elevation Difference 10.80 m
DeliveryLength Pump to Delivery end) 130.00 m
Add length for Bends etc 5% 8.00 m
Delivery Length 138.00 m

A Frictional Head Loss


Determination of friction factor of pipe using Colebrook Equation

Trial Delivery Pipe Diameter 100 mm


Trial Discharge 12 l/s
for uPVC pipe (delivery pipe) take "k" = 0.05 mm
Discharge Q (m3/s) 0.012 m3/s
Pi 3.14159
Trial "f" 0.02
F='1/f^.5 7.2708360944
Roughness of Pipe "k" m 5E-05 m
Diameter of Pipe "D" (m) 0.1 Colebrook Equation to determine friction factor "f"
f1=k/(3.7*D)= 0.0001351351 1/f^.5=-2*log(k/(3.7*D)+2.51/(Re*f^0.5)
Velocity in Pipe "V" 1.5286624204
D 0.1 Check for LHS=RHS
nue "υ" for water 1.009E-06 LHS='1/f^.5= 7.271
Reynold's No Re=V*D/nue 1.515E+05 RHS=-2*log(f1+f2)= 7.185
f2=2.51/(Re*f^0.5)= 1.205E-04 Difference= 0.086
Adopt OK
-2*log(f1+f2) 7.1849 "f"= 0.018916

Determination of friction factor using Moody Chart


Pi 3.14159
Roughness of Pipe "k" m 5E-05 m
Diameter of Pipe "D" (m) 0.1 m
k/D 0.0005
Discharge Q (m3/s) 0.012 m3/s
A 0.007853975
V 1.5278887442
nue "υ" for water 1.009E-06
Reynold's No Re=V*D/nue 1.514E+05
Finding "f" from Moody curve
k/D 0.0005
Re 1.514E+05
f from Moody curve 0.02

Design of Pump and Pipeline


Head Loss Computation
Input
Discharge "Q" (l/s) = 12 l/s
Diameter of Pipe "D" mm 100 mm
Discharge "Q" (m^3/s) = 0.012 m^3/s
Diameter of Pipe "D" (m) 0.1 m
1 Head loss due to friction of pipe=
Friction Factor "f"= 0.02
Pipe Length "L"= 138.00 m
Pi= 3.14159
Area of Pipe 0.0079 m^2
Velocity "u" = 1.52 m/s
"g"= 9.81
Darcy Weishach Equation
Frictional Head Loss "Hl"= f*L*u^2/(2*g*D)= 3.07 m

2 Bend and Joint Loss


Velocity Head "v^2/(2*g)"= 0.1178
Factor for 1 bend 0.5
No of Bends/Joints 5
Bend and Joint Loss 2.95 m
3 Entry and Exit Loss
factor for Entry and Exit loss 1
No of Entry/Exit 2
Entry and Exit Loss 0.2356 m
Total Frictional Head Loss (1+2+3) 6.2556 m

B Geopraphical Head Difference


Source Level 631.00 m
Delivery Level 641.80 m
Geographical Elevatin Difference 10.80 m

Total Working Head for Pump


Total Frictional Head Loss= 6.26 m
Geographical Elevatin Difference= 10.80 m
Total Working Head for Pump= 17.06 m
Say 18 m

Selection of Pump

Using performance chart provided by Kirloskar company

Select Pump KDS 822+


Monobloc Pump at 415 Volts, 50 Cycles/s, Head (m) Q (l/s)
Three Phase AC Power Supply
12 27.3
14 25.6
Suction=100mm 16 24.0
Delivery=100 mm 18 22.2
20 20.1
22 17.6
24 14.5

Pump Characterstic
(Kirloskar Pump-KDS 822+ 7.5 HP/5.5 KW)
28.0
26.0
24.0
22.0
20.0
Head (m)

18.0
16.0
14.0
12.0
11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Discharge (l/s)
Design of Pumping system and Selection of Pump
From Sumpwell to Tank1
Source Level 607.80 m
Delivery Level 819.80 m
Elevation Difference (H) 212.00 m
Required design Discharge (Q) 7.08 lps
0.007 m3/sec
Unit weight of water( ρ) 1,000 kg/m3
Gravitational Constsnt (g) 9.810 m/sec2
Pump efficiency (η) 0.470
Assume Velocity in pipe (v) 3.5 m/sec

Delivery Length ( Pump to Delivery end) 461.00 m

The Theoritical Capacity of the pump = (ρ*Q *H*g)/η 31,328.5 watt


watt 31.33 KW
42.1 HP

Diameter of Discharge Pipe (D) = (4*Q/V * π)^0.5


0.0507630582 m
51 mm
Trial for Pump LSF-100; 12.5 Hp
Total output 7.08 lps
Working head 250.00 m
Suction 80 mm
Delivery 80 mm

a) Determination of friction factor of pipe using Colebrook Equation

Trial Delivery Pipe Diameter 80 mm


Trial Discharge 7.08 l/s
For pipe (delivery pipe) take "k" = 0.003 mm
Discharge Q (m3/s) 0.00708 m³/s
Pi 3.14159
Trial "f" 0.02100
F='1/f^.5 6.901
Roughness of Pipe "k" m 3E-06 m
Diameter of Pipe "D" (m) 0.08 Colebrook Equation
f1=k/(3.7*D)= 1.013514E-05 1/f^.5=-2*log(k/(3.7*D)+2.51/(Re*f^0.5)
Velocity in Pipe "V" 1.4092356688
D 0.08 Check for LHS=RHS
nue "υ" for water 1.009E-06 LHS='1/f^.5= 6.901
Reynold's No Re=V*D/nue 1.117E+05 RHS=-2*log(f1+f2)= 7.564
f2=2.51/(Re*f^0.5)= 1.550E-04 Difference= -0.663

-2*log(f1+f2) 7.5642 "f"= 0.021000

b) Emperical Formula
i) Velocity in Pipe "V" 1.4092 m/sec
nue "υ" for water 1.009E-06
Diameter of Pipe "D" (m) 0.08 m
Reynold's No Re=V*D/nue 1.1173E+05
"f" = 0.0032+0.221/(Re^0.237) 0.0173

Page 3
Head Loss Calculation

Discharge "Q" (l/s) 7.08 l/s


Diameter of Pipe "D" mm 80 mm
Discharge "Q" (m^3/s) 0.00708 m^3/s
Diameter of Pipe "D" (m) 0.08 m

1 Head loss due to friction of pipe

Friction Factor "f" 0.02100


Pipe Length "L" 461.00 m
Pi 3.14159
Area of Pipe 0.005026544 m²
Velocity "v" 1.41 m/s
"g" 9.81
Darcy Weishach Equation
Frictional Head Loss 12.26 m

2 Bend and Joint Loss


Velocity Head "v^2/(2*g)" 0.1013
Factor for 1 bend 0.5
No of Bends/Joints 12
Bend and Joint Loss 0.61 m

3 Entry and Exit Loss


factor for Entry and Exit loss 1
No of Entry/Exit 2
Entry and Exit Loss 0.2026 m
Total Frictional Head Loss (1+2+3) 13.0726 m

Geopraphical Head Difference


Source Level 607.80 m
Delivery Level 819.80 m
Elevation Difference 212.00 m
Total Frictional Head Loss 13.07 m
Actual Working Head for Pump 225.07 m
Say 225.07 m < 250 m OK
Select Pump UPHA-293; 41 Hp

Page 4
Design of Pumping system and Selection of Pump
Tank1 to Tank2
Source Level 819.80 m
Delivery Level 1,004.80 m
Elevation Difference (H) 185.00 m
Required design Discharge (Q) 7.08 lps
0.007 m3/sec
Unit weight of water( ρ) 1,000 kg/m3
Gravitational Constsnt (g) 9.810 m/sec2
Pump efficiency (η) 0.470
Assume Velocity in pipe (v) 3.5 m/sec

Delivery Length ( Pump to Delivery end) 651.00 m

The Theoritical Capacity of the pump = (ρ*Q *H*g)/η 27,338.6 watt


watt 27.34 KW
36.7 HP

Diameter of Discharge Pipe (D) = (4*Q/V * π)^0.5


0.0507630582 m
51 mm
Trial for Pump LSF-100; 12.5 Hp
Total output 7.08 lps
Working head 250.00 m
Suction 80 mm
Delivery 80 mm

a) Determination of friction factor of pipe using Colebrook Equation

Trial Delivery Pipe Diameter 80 mm


Trial Discharge 7.08 l/s
For pipe (delivery pipe) take "k" = 0.003 mm
Discharge Q (m3/s) 0.00708 m³/s
Pi 3.14159
Trial "f" 0.02100
F='1/f^.5 6.901
Roughness of Pipe "k" m 3E-06 m
Diameter of Pipe "D" (m) 0.08 Colebrook Equation
f1=k/(3.7*D)= 1.013514E-05 1/f^.5=-2*log(k/(3.7*D)+2.51/(Re*f^0.5)
Velocity in Pipe "V" 1.4092356688
D 0.08 Check for LHS=RHS
nue "υ" for water 1.009E-06 LHS='1/f^.5= 6.901
Reynold's No Re=V*D/nue 1.117E+05 RHS=-2*log(f1+f2)= 7.564
f2=2.51/(Re*f^0.5)= 1.550E-04 Difference= -0.663

-2*log(f1+f2) 7.5642 "f"= 0.021000

b) Emperical Formula
i) Velocity in Pipe "V" 1.4092 m/sec
nue "υ" for water 1.009E-06
Diameter of Pipe "D" (m) 0.08 m
Reynold's No Re=V*D/nue 1.1173E+05
"f" = 0.0032+0.221/(Re^0.237) 0.0173

Head Loss Calculation

Discharge "Q" (l/s) 7.08 l/s


Diameter of Pipe "D" mm 80 mm
Discharge "Q" (m^3/s) 0.00708 m^3/s
Diameter of Pipe "D" (m) 0.08 m

1 Head loss due to friction of pipe

Friction Factor "f" 0.02100


Pipe Length "L" 651.00 m
Pi 3.14159
Area of Pipe 0.005026544 m²
Velocity "v" 1.41 m/s
"g" 9.81
Darcy Weishach Equation
Frictional Head Loss 17.32 m

2 Bend and Joint Loss


Velocity Head "v^2/(2*g)" 0.1013
Factor for 1 bend 0.5
No of Bends/Joints 12
Bend and Joint Loss 0.61 m

3 Entry and Exit Loss


factor for Entry and Exit loss 1
No of Entry/Exit 2
Entry and Exit Loss 0.2026 m
Total Frictional Head Loss (1+2+3) 18.1326 m

Geopraphical Head Difference


Source Level 819.80 m
Delivery Level 1,004.80 m
Elevation Difference 185.00 m
Total Frictional Head Loss 18.13 m
Actual Working Head for Pump 203.13 m
Say 203.13 m < 250 m OK
Select Pump UPHA-293; 41 Hp
Design of Pumping system and Selection of Pump
Tank2 to Tank3
Source Level 1,004.80 m
Delivery Level 1,194.80 m
Elevation Difference (H) 190.00 m
Required design Discharge (Q) 4.78 lps
0.005 m3/sec
Unit weight of water( ρ) 1,000 kg/m3
Gravitational Constsnt (g) 9.810 m/sec2
Pump efficiency (η) 0.470
Assume Velocity in pipe (v) 3.5 m/sec

Delivery Length ( Pump to Delivery end) 695.00 m

The Theoritical Capacity of the pump = (ρ*Q *H*g)/η 18,956.3 watt


watt 18.96 KW
25.5 HP

Diameter of Discharge Pipe (D) = (4*Q/V * π)^0.5


0.0417104714 m
42 mm
Trial for Pump LSF-100; 12.5 Hp
Total output 4.78 lps
Working head 250.00 m
Suction 80 mm
Delivery 80 mm

a) Determination of friction factor of pipe using Colebrook Equation

Trial Delivery Pipe Diameter 80 mm


Trial Discharge 4.78 l/s
For pipe (delivery pipe) take "k" = 0.003 mm
Discharge Q (m3/s) 0.00478 m³/s
Pi 3.14159
Trial "f" 0.02100
F='1/f^.5 6.901
Roughness of Pipe "k" m 3E-06 m
Diameter of Pipe "D" (m) 0.08 Colebrook Equation
f1=k/(3.7*D)= 1.013514E-05 1/f^.5=-2*log(k/(3.7*D)+2.51/(Re*f^0.5)
Velocity in Pipe "V" 0.951433121
D 0.08 Check for LHS=RHS
nue "υ" for water 1.009E-06 LHS='1/f^.5= 6.901
Reynold's No Re=V*D/nue 7.544E+04 RHS=-2*log(f1+f2)= 7.241
f2=2.51/(Re*f^0.5)= 2.296E-04 Difference= -0.340

-2*log(f1+f2) 7.2405 "f"= 0.021000

b) Emperical Formula
i) Velocity in Pipe "V" 0.9514 m/sec
nue "υ" for water 1.009E-06
Diameter of Pipe "D" (m) 0.08 m
Reynold's No Re=V*D/nue 7.5436E+04
"f" = 0.0032+0.221/(Re^0.237) 0.0186

Head Loss Calculation

Discharge "Q" (l/s) 4.78 l/s


Diameter of Pipe "D" mm 80 mm
Discharge "Q" (m^3/s) 0.00478 m^3/s
Diameter of Pipe "D" (m) 0.08 m

1 Head loss due to friction of pipe

Friction Factor "f" 0.02100


Pipe Length "L" 695.00 m
Pi 3.14159
Area of Pipe 0.005026544 m²
Velocity "v" 0.95 m/s
"g" 9.81
Darcy Weishach Equation
Frictional Head Loss 8.39 m

2 Bend and Joint Loss


Velocity Head "v^2/(2*g)" 0.046
Factor for 1 bend 0.5
No of Bends/Joints 12
Bend and Joint Loss 0.28 m

3 Entry and Exit Loss


factor for Entry and Exit loss 1
No of Entry/Exit 2
Entry and Exit Loss 0.092 m
Total Frictional Head Loss (1+2+3) 8.762 m

Geopraphical Head Difference


Source Level 1,004.80 m
Delivery Level 1,194.80 m
Elevation Difference 190.00 m
Total Frictional Head Loss 8.76 m
Actual Working Head for Pump 198.76 m
Say 198.76 m < 250 m OK
Select Pump UPF-200; 25 Hp