You are on page 1of 10

Simulation Report

Company

Author
PhuongMr

Date
Tuesday, 25 June, 2019

Software Used
Solid Edge (219.00.00.091 x64)
Femap (11.3.1)

Solver Used
NX Nastran (11.0)

Table of Contents
1. Introduction
2. Model Information
3. Study Properties
4. Study Geometry
5. Material Properties
6. Override Properties
7. Loads
8. Constraints
9. Connectors
10. Mesh Information
11. Results
12. Optimizations
13. Conclusion
14. Disclaimer

1. Introduction
2. Model Information
Documen
E:\9. XNCĐ\5. Xưởng SCTB K-KT\1. Skid2A\A. Skid Frame.asm
t

3. Study Properties
Study Property Value
Study name Static Study 1
Study Type Linear Static
Mesh Type Tetrahedral
Iterative Solver On
NX Nastran Geometry Check Warning Only
NX Nastran command line
NX Nastran study options
NX Nastran generated options
NX Nastran default options
Surface results only option On

4. Study Geometry
4.1 Solids
Solid Name Material Mass Volume Weight
Steel, structural 451892.623
V50x50x6 L= 844.par:4 3.540 kg 34688.814 mN
(Occurrence) mm^3
I beam 200x100x6x9 Steel, structural 9920164.279 761505.539
77.705 kg
L=3395.par:1 (Occurrence) mm^3 mN
I beam 200x100x6x9 Steel, structural 4781894.841 367074.506
37.457 kg
L=1694.par:1 (Occurrence) mm^3 mN
I beam 200x100x6x9 Steel, structural 9443970.214 724951.263
73.975 kg
L=3289.par:1 (Occurrence) mm^3 mN
I beam 160x82x5x7 Steel, structural 1547332.459 118778.501
12.120 kg
L=844.par:3 (Occurrence) mm^3 mN
I beam 160x82x5x7 Steel, structural 1547332.459 118778.501
12.120 kg
L=844.par:2 (Occurrence) mm^3 mN
I beam 160x82x5x7 Steel, structural 1547332.459 118778.501
12.120 kg
L=844.par:1 (Occurrence) mm^3 mN
I beam 200x100x6x9 Steel, structural 4781894.841 367074.506
37.457 kg
L=1694.par:2 (Occurrence) mm^3 mN
I beam 200x100x6x9 Steel, structural 9920164.279 761505.539
77.705 kg
L=3395.par:2 (Occurrence) mm^3 mN
Steel, structural 615340.345
Padeye.par:1 4.820 kg 47235.617 mN
(Occurrence) mm^3
I beam 160x82x5x7 Steel, structural 1547332.459 118778.501
12.120 kg
L=844.par:4 (Occurrence) mm^3 mN
I beam 160x82x5x7 Steel, structural 1547332.459 118778.501
12.120 kg
L=844.par:5 (Occurrence) mm^3 mN
I beam 160x82x5x7 Steel, structural 1547332.459 118778.501
12.120 kg
L=844.par:6 (Occurrence) mm^3 mN
Steel, structural 615340.345
Padeye.par:2 4.820 kg 47235.617 mN
(Occurrence) mm^3
Steel, structural 615340.345
Padeye.par:3 4.820 kg 47235.617 mN
(Occurrence) mm^3
Steel, structural 615340.345
Padeye.par:4 4.820 kg 47235.617 mN
(Occurrence) mm^3
Steel, structural 284.768 36354900.000 2790725.731
Plate s=6.par:1
(Occurrence) kg mm^3 mN
Steel, structural 451892.623
V50x50x6 L= 844.par:1 3.540 kg 34688.814 mN
(Occurrence) mm^3
Steel, structural 451892.623
V50x50x6 L= 844.par:2 3.540 kg 34688.814 mN
(Occurrence) mm^3
Steel, structural 451892.623
V50x50x6 L= 844.par:3 3.540 kg 34688.814 mN
(Occurrence) mm^3

5. Material Properties
5.1 Steel, structural
Property Value
Density 7833.000 kg/m^3
Coef. of Thermal
0.0000 /C
Exp.
Thermal Conductivity 0.032 kW/m-C
Specific Heat 481.000 J/kg-C
Modulus of Elasticity 199947.953 MegaPa
Poisson's Ratio 0.290
Yield Stress 262.001 MegaPa
Ultimate Stress 358.527 MegaPa
Elongation % 0.000
6. Override Properties

7. Loads
Load Load Load Load Load Direction
Load Direction
Name Type Value Distribution Option
981 ( 0.00, 0.00,
Gravity 1 Gravity Along a vector
cm/s^2 -1.00 )
( 0.00, 0.00,
Force 1 Force 5e+03 mN Per Entity Along a vector
-1.00 )

8. Constraints
Constraint
Constraint Type Degrees of Freedom
Name
Fixed 1 Fixed FREE DOF: None

9. Connectors
9.1 Other Connectors
Connector Connector Search Minimum Coefficient Of Penalty
Name Type Distance Search Distance Static Friction Value
Connector 1 Glue 0.50 mm 100.00
Connector 2 Glue 0.50 mm 100.00
Connector 3 Glue 0.50 mm 100.00
Connector 4 Glue 0.50 mm 100.00
Connector 5 Glue 0.50 mm 100.00
Connector 6 Glue 0.50 mm 100.00
Connector 7 Glue 0.50 mm 100.00
Connector 8 Glue 0.50 mm 100.00
Connector 9 Glue 0.50 mm 100.00
Connector 10 Glue 0.50 mm 100.00
Connector 11 Glue 0.50 mm 100.00
Connector 12 Glue 0.50 mm 100.00
Connector 13 Glue 0.50 mm 100.00
Connector 14 Glue 0.50 mm 100.00
Connector 15 Glue 0.50 mm 100.00
Connector 16 Glue 0.50 mm 100.00
Connector 17 Glue 0.50 mm 100.00
Connector 18 Glue 0.50 mm 100.00
Connector 19 Glue 0.50 mm 100.00
Connector 20 Glue 0.50 mm 100.00
Connector 21 Glue 0.50 mm 100.00
Connector 22 Glue 0.50 mm 100.00
Connector 23 Glue 0.50 mm 100.00
Connector 24 Glue 0.50 mm 100.00
Connector 25 Glue 0.50 mm 100.00
Connector 26 Glue 0.50 mm 100.00
Connector 27 Glue 0.50 mm 100.00
Connector 28 Glue 0.50 mm 100.00
Connector 29 Glue 0.50 mm 100.00
Connector 30 Glue 0.50 mm 100.00
Connector 31 Glue 0.50 mm 100.00
Connector 32 Glue 0.50 mm 100.00
Connector 33 Glue 0.50 mm 100.00
Connector 34 Glue 0.50 mm 100.00
Connector 35 Glue 0.50 mm 100.00
Connector 36 Glue 0.50 mm 100.00
Connector 37 Glue 0.50 mm 100.00
Connector 38 Glue 0.50 mm 100.00
Connector 39 Glue 0.50 mm 100.00
Connector 40 Glue 0.50 mm 100.00
Connector 41 Glue 0.50 mm 100.00
Connector 42 Glue 0.50 mm 100.00
Connector 43 Glue 0.50 mm 100.00
Connector 44 Glue 0.50 mm 100.00
Connector 45 Glue 0.50 mm 100.00

9.2 Bolted Connectors


Connector Threading Bolt Shaft Nut Pre-Stress
Name Type Diameter Diameter Diameter Value

10. Mesh Information


Mesh type Tetrahedral
Total number of bodies
20
meshed
Total number of elements 61,424
Total number of nodes 107,872
Subjective mesh size (1-10) 3

11.Results
11.1 Displacement Results
Result component: Total Translation
Extent Value X Y Z
133.783
Minimum 0 mm 1802.810 mm 513.999 mm
mm
Maximu 188.000
0.0457 mm 853.804 mm 1698.999 mm
m mm
Total Translation

11.2 Stress Results


Result component: Von Mises
Extent Value X Y Z
Minimum 0.0268 MegaPa 1744.142 mm 3389.142 mm 191.000 mm
Maximu
9.58 MegaPa 1777.451 mm 2883.999 mm 145.995 mm
m
Von Mises

11.3 Factor of Safety Results


Result Component: Factor of Safety
Extent Value X Y Z
Minimum 27.4 1777.451 mm 2883.999 mm 145.995 mm
Maximu
9.76e+03 1744.142 mm 3389.142 mm 191.000 mm
m
Factor of Safety

11.4 Bolt Connector Force Results


PL1 PL2
Connector Materia Axial Plane 1 Plane 2
Shear Shear Torque
Name l force Moment Moment
Force Force

12. Optimizations
13. Conclusion

14. Disclaimer
Important Information
This report should not be used to solely judge a design idea's suitability to a given set of environmental
conditions. Siemens makes every effort to ensure that its products provide as much guidance and help
as possible. However this does not replace good engineering judgment, which is always the
responsibility of our users. A qualitative approach to engineering should ensure that the results of this
evaluation are evaluated in conjunction with the practical experience of design engineers and analysts,
and ultimately experimental test data. The results contained within this report are believed to be
reliable but should not be construed as providing any sort of warranty for fitness of purpose.