Technical data sheet

Steel fibers with hooked ends

Steel fibers with hooked ends are filaments of steel wire for reinforcement of concrete and mortar.
For manufacturing wire fibers are using wires of different diameters deformed and cut to lengths.

Steel fibers reinforcement is widely used as the main and unique reinforcing for industrial concrete
floor slabs, shotcrete, prefabricated concrete products, slabs on piles, tunnel segments, concrete
cellars, foundation slabs, and shear reinforcement in prestressed elements.

Steel fibers improve the mechanical properties concrete and materials such as ductility, durability,
energy absorption, fatigue, and toughness. This fiber helps to controls plastic shrinkage cracking in
concrete; helps reduce or eliminate need for conventional reinforcement.

Length Diameter Aspect ratio Cross Tensile strength of drawn


Designation
(mm) (mm) L/d section wire
ZS/N 1.05 x 50 50 ± 10% 1.05 ± 10% 48 round 1100 - 1400 N/mm2

PERFORMANCE

Class C20/25 C25/30 C30/37 C32/40 C35/45 C40/50 C45/55


ZS/N 1.05 x 50
Fctm,fi 3.5 4.1 4.6 4.8 5.1 5.6 6.1
Dosage Re,3 R10,30 fe,3 f10,30 fe,3 f10,30 fe,3 f10,30 fe,3 f10,30 fe,3 f10,30 fe,3 f10,30 fe,3 f10,30
[kg/m3] % % [Mpa] [Mpa] [Mpa] [Mpa] [Mpa] [Mpa] [Mpa] [Mpa] [Mpa] [Mpa] [Mpa] [Mpa] [Mpa] [Mpa]
15 32 32 1.1 1.1 1.3 1.3 1.5 1.5 1.6 1.5 1.6 1.6 1.8 1.8 2.0 1.9
20 40 40 1.4 1.4 1.7 1.6 1.9 1.9 2.0 1.9 2.1 2.1 2.3 2.2 2.5 2.4
25 48 47 1.7 1.7 2.0 1.9 2.2 2.2 2.3 2.3 2.5 2.4 2.7 2.7 2.9 2.9
30 56 55 2.0 1.9 2.3 2.3 2.6 2.6 2.7 2.7 2.9 2.8 3.1 3.1 3.4 3.3
35 62 61 2.2 2.2 2.5 2.5 2.9 2.8 3.0 3.0 3.2 3.1 3.5 3.4 3.7 3.7
40 67 67 2.4 2.4 2.8 2.7 3.1 3.1 3.2 3.2 3.4 3.4 3.8 3.7 4.1 4.0
45 73 73 2.6 2.6 3.0 3.0 3.4 3.4 3.6 3.5 3.8 3.7 4.1 4.1 4.5 4.4
50 78 77 2.8 2.7 3.2 3.2 3.6 3.6 3.8 3.7 4.0 4.0 4.4 4.4 4.7 4.7

For concrete compressive strengths not exceeding fc’=45MPa (concrete class C45/55)

fctm,fl - mean flexural tensile strength of plain concrete to EN 1992-1-1


Re,3 - equivalent flexural ratio at total deflection of 3mm to JSCE
fe,3 - equivalent flexural strength to JSCE, [fe,3= fctm,fl ·Re,3/100]
R10,30 - toughness ratio of toughness indices I10 and I30 to ASTM C1018,[R10,30=100·(I30-I10)SFRC/( I30-I10)EP]
f10,30 - mean flexural stress between 5.5δ and 15.5δ deflections to ASTM C1018, [f10,30= fctm,fl ·R10,30/100]
DOSAGE

Recommended dosage of steel fiber is 25 kg per 1m³ of concrete for 0,5 CMOD.

PACKING

Steel fibers with hooked ends are available in paper sacks of 20 kg. Pallet weight 1000 kg. Palettes
are wrapped in PVC foil.

COMPLIANCE

Steel fibers conform to EN 14889-1:2006.


Product certificated by Tsus, certificate No. 1301 – CPR- 0662

Spajic d.o.o. * Milosevski put bb Negotin * Republic of Serbia


Phone: +381 19 542 630 Fax: +381 19 549 774
www.spajic.com info@spajic.com