You are on page 1of 1

RATINGS & STANDARDS

ENGINE RATINGS AND FUEL CONSUMPTION


2
ISO STANDARD (CONTINUOUS) POWER RATINGS FOR MODEL 16V-AT27GL
GAS COMPRESSION (GC)
130° F (54° C) AUXILIARY WATER TEMPERATURE
180° F (82° C) JACKET WATER TEMPERATURE

P a rt L o a d F u e l C o n s u m p tio n
W a s te g a te s S e t F o r C o n tin u o u s P o w e r R a tin g

8000

7800 11000

7600 1000 RPM


950 RPM
7400 900 RPM 10500
850 RPM
7200 800 RPM
750 RPM
10000
7000

6800
9500
6600

6400
9000

6200

6000 8500
1200 1600 2000 2400 2800 3200 3600 4000 4400 4800

BHP

RPM 750 800 850 900 950 1000


CONTINUOUS BHP 3375 3605 3830 4055 4280 4500
OVERLOAD BHP 3445 3675 3900 4130 4360 4590

OVERLOAD Allowed 2 Hours Per 24 Hours


Barometer Ambient Temperature
STANDARD CONDITIONS
29.54 in. Hg. (100 kPa) 77° F (25° C)
Altitude: For Elevations Up To 6000 Ft. Refer To S-9063-1
DEDUCTIONS
Ambient Temperature: 2 Percent per 10° F (5.5° C) above 100° F (38° C)
3 3
Dry Natural Gas – 900 Btu/ft (35.38 MJ/m ) SLHV; 91 WKI™
FUEL
Refer to S-7884-7 for Full Fuel Specification
EQUIPMENT Engine Equipped with Lube Oil and Cooling Water Pumps but without Radiator Fan
Turbocharged & Intercooled with 130° F (54.5° C) Auxiliary Water
ENGINE DATA
9.0:1 Compression Ratio

NOTES:
1. Engine set to an exhaust oxygen concentration of 11.2% at rated speed and load at standard 22° BTDC timing.
Reference S-9052-6.
2. ISO Standard (continuous) power ratings conform to ISO 3046/1, latest version, with a mechanical efficiency of 90%
and Tcra of 130° F (54.5° C) limited to ± 10° F (± 5.5° C).

Page 1 of 1

ENGINE RATINGS AND FUEL CONSUMPTION Ref.


MODEL 16V-AT27GL — GC EN: 126150
130° F (54° C) AUX. WATER TEMPERATURE C
DATE: 1/02
180° F (82° C) JACKET WATER TEMPERATURE 1016-9