40D
A-B
Pile Cap
X
Lean Concrete 0.075m
0.3m
> For the top of the steel bar's length, the formula will be 40D. The D is instant of diameter
of the Steel bar.
> The bended's bar must be 300mm in standard
For Example :
A=9m Steel bar = T32
B=8.5m
X=1.5m
C) 40D
40(32) = 1.28m
Length of Links
> 2[(A-0.5)+(B-0.5)] *0.5m is Concrete Cover
If the they write R200 with mean every 200mm have 1 link
Therefore
B) 1.425m / 200 = 7nos
7nos + 1 = 8nos
* add 1 link from the top of the ground