Professional Documents
Culture Documents
Gas Lift
Equipment Catalog
© Schlumberger 2003
Schlumberger
225 Schlumberger Drive
Sugar Land, Texas 77478
All rights reserved. No part of this book may be reproduced,
stored in a retrieval system, or transcribed in any form or
by any means, electronic or mechanical, including photo-
copying and recording, without prior written permission
of the publisher.
AL_03_056_0
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Conventional Injection-Pressure-Operated Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Conventional Production-Pressure-Operated Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Conventional Pilot-Operated Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Conventional Waterflood Flow Regulator Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
B-Series Conventional Mandrels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
C-Series Conventional Mandrels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Conventional Reverse-Flow Check Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Guide to Compatibility for Camco Conventional Gas Lift Valves, Subsurface Control Accessories and Mandrels
Valve Tubing Flow Annular Flow
Injection-Pressure-Operated Production-Pressure-Operated Injection-Pressure-Operated Production-Pressure-Operated
Mandrel Reverse- Mandrel Reverse- Mandrel Reverse- Mandrel Reverse-
Flow Flow Flow Flow
Check Check Check Check
Valve Valve Valve Valve
J-50 na Integral na na na na na na
J-40 B, B deflector lug B-1 BR deflector lug B-1 BR deflector lug B-1 BR deflector lug B-1
J-20 C, C deflector lug J-20 CR deflector lug J-20 CR deflector lug CF CR deflector lug CF
JR-50 na na na Integral na na na na
JR-40 BR deflector lug B-1 B, B deflector lug BF B, B deflector lug BF BR deflector lug B-1
JR-20 CR deflector lug J-20 C, C deflector lug CF C, C deflector lug CF CR deflector lug J-20
BP-2 B, B deflector lug B-1 na na na na na na
CP-2 C, C deflector lug J-20 na na na na na na
JW-40
B, B deflector lug Integral na na na na na na
FM-14
JW-20
C, C deflector lug Integral na na na na na na
FM-12
vi
Valve Specifications PPEF ‡
Type† Ab – Effective Port Ap – Area Ap /Ab 1 – (Ap /Ab) PPEF = (Ap /Ab)/[1 – (Ap /Ab)]
Bellows Area Size of Port with (in.2 [mm2]) (in.2 [mm2]) (in.2 [mm2])
(in.2 [mm2]) (in. [mm]) Bevel (in.2 [mm2])
0.188 [4.8] 0.029 [18.7] 0.038 [24.5] 0.962 [620.7] 0.040 [25.8]
0.250 [6.4] 0.051 [32.9] 0.066 [42.6] 0.934 [602.6] 0.071 [45.8]
0.313 [7.9] 0.079 [51.0] 0.103 [66.5] 0.897 [578.7] 0.115 [74.2]
J-20 0.770 [496.8]
0.375 [9.5] 0.113 [72.9] 0.147 [94.8] 0.853 [550.4] 0.172 [111.0]
0.438 [11.1] 0.154 [99.4] 0.200 [129.0] 0.800 [516.2] 0.250 [161.3]
0.500 [12.7] 0.200 [129.0] 0.260 [167.8] 0.740 [477.4] 0.351 [226.5]
0.125 [3.2] 0.013 [8.4] 0.017 [11.0] 0.983 [634.2] 0.017 [11.0]
JR-20 0.770 [496.8] 0.188 [4.8] 0.029 [18.7] 0.038 [24.5] 0.962 [620.7] 0.040 [25.8]
0.250 [6.4] 0.051 [32.9] 0.066 [42.6] 0.934 [602.6] 0.071 [45.8]
0.250 [6.4] 0.051 [32.9] 0.066 [42.6] 0.934 [602.6] 0.071 [45.8]
0.313 [7.9] 0.079 [51.0] 0.103 [66.5] 0.897 [578.7] 0.115 [74.2]
CP-2§ 0.770 [496.8] 0.375 [9.5] 0.113 [72.9] 0.147 [94.8] 0.853 [550.4] 0.172 [111.0]
0.438 [11.1] 0.154 [99.4] 0.200 [129.0] 0.800 [516.2] 0.250 [161.3]
0.500 [12.7] 0.200 [129.0] 0.260 [167.8] 0.740 [477.4] 0.351 [226.5]
0.125 [3.2] 0.013 [8.4] 0.042 [27.1] 0.958 [618.1] 0.044 [28.4]
0.188 [4.8] 0.029 [18.7] 0.094 [60.6] 0.906 [584.6] 0.104 [67.1]
J-40 0.770 [496.8] 0.250 [6.4] 0.051 [32.9] 0.165 [106.5] 0.835 [538.7] 0.198 [127.7]
0.313 [7.9] 0.079 [51.0] 0.255 [164.5] 0.745 [480.7] 0.342 [220.7]
0.375 [9.5] 0.113 [72.9] 0.365 [235.5] 0.635 [409.7] 0.575 [371.0]
0.125 [3.2] 0.013 [8.4] 0.042 [27.1] 0.958 [618.1] 0.044 [28.4]
JR-40 0.310 [200.0]
0.188 [4.8] 0.029 [18.7] 0.094 [60.6] 0.906 [584.6] 0.104 [67.1]
0.188 [4.8] 0.029 [18.7] 0.094 [60.6] 0.906 [584.6] 0.104 [67.1]
BP-2§ 0.310 [200.0] 0.250 [6.4] 0.051 [32.9] 0.165 [106.5] 0.835 [538.7] 0.198 [127.7]
0.313 [7.9] 0.079 [51.0] 0.255 [164.5] 0.745 [480.7] 0.342 [220.7]
0.375 [9.5] 0.113 [72.9] 0.365 [235.5] 0.635 [409.7] 0.575 [371.0]
0.125 [3.2] 0.013 [8.4] 0.108 [69.7] 0.892 [575.5] 0.121 [78.1]
J-50 0.120 [77.4] 0.156 [3.9] 0.020 [12.9] 0.167 [107.7] 0.833 [537.5] 0.200 [129.0]
0.203 [5.1] 0.037 [23.9] 0.308 [198.7] 0.692 [446.5] 0.445 [287.1]
0.250 [6.4] 0.051 [32.9] 0.425 [274.2] 0.575 [371.0] 0.739 [476.8]
JR-50 0.120 [77.4] 0.094 [2.3] 0.008 [5.2] 0.067 [43.2] 0.933 [602.0] 0.072 [46.5]
† Monel seats are standard in these valves.
‡ PPEF (production pressure effect factor) was formerly referred to as TEF (tubing effect factor).
§ These specifications apply to the pilot section only.
normally used for injection-pressure- 1⁄8, 5⁄32, 13⁄64, and 1⁄4 in. [3.2, 3.9, 5.1, and
[25.4-mm] OD J-40 valves, and 11⁄2-in. 3⁄16 to 1⁄2 in. [4.8 to 12.7 mm].
Flow areas
The flow area for the 1-in. [25.4-mm]
OD JW-40 valves ranges from an equiv-
alent 1⁄8-in. [3.2-mm] minimum port
to an equivalent 7⁄32-in. [5.5-mm] maxi-
mum port. For the 1-in. [25.4-mm] OD
FM-14 valves, the flow area ranges from
a 0.090-in. [2.3-mm] minimum port to
a 0.185-in. [4.5-mm] maximum port.
The flow area for the 11⁄2-in.
[38.1-mm] OD JW-20 valves ranges
from an equivalent 1⁄8-in. [3.2-mm]
minimum port to an equivalent 3⁄8-in.
[9.5-mm] maximum port. For the
11⁄2-in. [38.1-mm] OD F-12 valves,
the flow area ranges from a 5⁄64-in.
[1.9-mm] minimum port to an 11⁄32-in.
[8.7-mm] maximum port.
Introduction
Conventional reverse-flow check
valves are velocity check valves used
with conventional Camco gas lift
valves that do not have integral
reverse-flow check valves. These
check valves protect the casing from
backflow through valves that are
below the working valve and allow the
application of pressure to the tubing
for circulation or acidizing. Reverse-
flow check valves also prevent the
commingling of production fluids in
dual gas lift installations.
This line of valves includes the 1-in.
[25.4-mm] OD BF and B-1 valves and
the 11⁄2-in. [38.1-mm] OD CF and J-20
valves. These valves each have an elas-
BF B-1 CF J-20 tomeric soft seat and a stainless steel
hard seat. The initial seal is between
the stainless steel check dart and the
soft seat. These check valves can with-
stand 10,000-psi [68,950-kPa] differ-
ential pressure and can be converted
from velocity check valves to positive
check valves by adding a spring.
Flow area
The flow area for the 1-in. [25.4-mm]
OD BF and B-1 valves is equivalent to
a 5⁄16-in. [7.9-mm] port.
The flow area for the 11⁄2-in.
[38.1-mm] OD valves is equivalent to
a 1⁄2-in. [12.7-mm] port for CF valves
and a 9⁄16-in. [14.3-mm] port for
J-20 valves.
Operation
Reverse-flow check valves require
Engineering Data for Conventional Reverse-Flow Check Valves flow to close. As the differential pres-
Type† OD Equivalent Port Size Connecting Thread sure across the check dart of the valve
(in. [mm]) (in. [mm]) (in. - TPI) increases, the dart contacts the soft
BF 1.000 [25.4] 0.313 [7.9] 0.500 - 14 NPT seat and then the hard seat to form a
BP-1 1.000 [25.4] 0.313 [7.9] 0.500 - 14 NPT seal and close the check valve.
CF 1.500 [38.1] 0.500 [12.7] 0.500 - 14 NPT
J-20 1.500 [38.1] 0.563 [14.3] 0.500 - 14 NPT
†Optional spring is available.