You are on page 1of 9

AC

C
ES
Network Access Control

S
AC-ASP-8000 Access Control System

SE
Real-time monitoring and remote control functions: Can real-time monitor all doors status,

C
alarm status and access situation, real-time display personnel information and photographs; online
remote door open, forcethe door to be normal open or normal close status; allow user to adjustthe

U
delay time and can match with the TCP / IP communication module to achieve remote control
within the LAN and the Internet

R
Powerful personalized accesscontrol privilege management: 255 personalized time profile

IT
control, you can define an individual who can enter someof doors within specified months, days,
weeks or hours etc. You can quickly and easily report the loss to enable or disable a certain

Y
number of cards or card. you can set the scheduled opening hours from time to time

PR
Mass storage and anti-power-down protection structures for data: You can store 20,000
offline registration card managementprivilege, 100,000 records, using non-volatile flash memory
chip set, the data is not lost after the power failure

O
Anti-static anti-lightning surge and anti-wrong Circuit connection Design: pass the

D
international standards, 4000V 50 consecutive times imitation lightning discharge tests and pass
the EMI (electromagnetic interference) and the electrical performanceof quality inspection

U
C
TS
LT
D
AC
C
ES
Network Access Control

S
Basic Function

SE
• 20,000 cards Permissions
• 100,000 offline records AC-ASP8000
• Flexible privilege management Networked Access Control

C
• Time privilege management

U
• Offline operation Combination of advance and compatibility (can be used on Windows XP, Vista and
• Real time monitor, photo display, door W indows 7 and 8

R
status display
• Real time extraction Multi commonstable communicationway (RS232, RS485 or TCP/IP)

IT
• Force to close and open door
• Remote open Safe “Easy-style" upgrademode

Y
• Interface locking
• Time span linkage

PR
Volume Settings allows customers to use the system more efficiently
• Small amount privilege individual
revision and uploading
• Quick search of people inside doors Customizable report query, export to Excel, and print mode

O
• Quick location of people
Interactive user-friendly software interface

D
Detailed operation log

U
"Multi-User Manager" feature Real-

C
time prompts by color and sound

TS
Specified card reader to privileged card

LT
Long holiday

D
Shield for no use functionand interface
AC
C
ES
Network Access Control

S
SE
Cable:
Cabling The cable from card reader to controller:5/6 core shielded multi-strand twisted-pair cable

C
with at least 0.3mm diameter. Maximum distance can not be more than 100mtrs

U
Installation The cable from exit button to controller: 2 core with at least 0.3mm diameter

R
The cable from lock deviceto controller: 2 core for power of at least 1.0mm diameter

IT
Suggestedwithin 50mtrs,the longest distance must not be more than 100mtrs

Y
Installation:

PR
Installation and commissioning should be undertakenby either of the following:
1. A proven and experiencedaccess control engineer
2. A proven and experiencedIT engineer

O
All cables should be installed within PVC or Galvanized conduits or PVC trunkingand certainly not

D
installed near 220v mains cables

U
Although the controller has a good leak-proof anti-static electricity lightning design, the power

C
supply cabinet must be connectedto ground earth

TS
Do not attempt removal or replacement of the controller chips, non-professional operation will lead
to control damageand invalidate warranty

Do not connectthe controllers and other high current devices to the same power outlet

LT
D
AC
C
ES
Network Access Control

S
SE
System

C
schematic

U
R
IT
Y
PR
O
D
U
C
TS
LT
D
AC
C
ES
Network Access Control

S
SE
Parameter index:

PCB board size: 160mm x 106mm


AC-ASP8001

C
Power Supply Size: To Be Taylored to your requirments.
Power supply: 12V DC 1-5amp

U
Circuit board power consumption: less than 100mA
Reader Input Format: Wiegand26 (compatible with all readers under the agreement,such as

R
Single Door Controller Motorola, HID, EM, Mifare one, etc.).

IT
Communication: TCP/IP 10M/100M self adaptive
Function Description: can control one door, enter via card swiping and exit via card swiping or
exit button

Y
Quantity of reader: 2 (1 in, 1 out)
Output relay: 1 (N/O, C, NC contacts) Open

PR
delay time: 1-600seconds adjustable
Maximum number of controllers: Unlimited
Operating temperature: -40 to 70 degrees Celsius

O
Run Humidity: 10-90% RH, non-condensing
Signal output communication format and baud rate: Support LAN, Intranet, fixed Internet

D
WAN IP address.
Maximum number of users: 20,000 cards permissions

U
Offlinestorage: 100,000 records
Power failure protection measures: high-speed flash memorydesign, and never lose data

C
Maximum distance between card reader and the controller: 100mtr,typical operation within

TS
80mtr
Maximum distance for the bus line: Depends on the network cover area
Maximum distance between controller to the PC: No limit

LT
D
AC
AC-ASP8001

C
One Door Controller

ES
Wiring Guide

S
SE
C
U
R
IT
Y
PR
O
D
U
C
TS
LT
D
AC
C
ES
Network Access Control

S
SE
Parameter index:

AC-ASP8002

C
PCB board size: 160mm x 106mm
Case Size: To be taylored to your requirments

U
Power supply: 12V DC 1-5amp
Circuit board power consumption: less than 100mA

R
Two Door Controller Reader Input Format: Wiegand26 (compatible with all readers under the agreement,such as

IT
Motorola, HID, EM, Mifare one, etc.).
Communication: TCP/IP 10M/100M self adaptive

Y
Function Description: can control two doors, enter via card swiping and exit via card swiping or
exit button
Quantity of readers: 4 (2 in, 2 out)

PR
Output relay: 2 (N/O, C, NC contacts) Open
delay time: 1-600seconds adjustable
Maximum number of controllers: Unlimited

O
Operating temperature: -40 to 70 degrees Celsius
Run Humidity: 10-90% RH, non-condensing

D
Signal output communication format and baud rate: Support LAN, Intranet, fixed Internet
WAN IP address.

U
Maximum number of users: 20,000 cards permissions

C
Offlinestorage: 100,000 records
Power failure protection measures: high-speed flash memorydesign, and never lose data

TS
Maximum distance between card reader and the controller: 100mtr,typical operation within
80mtr
Maximum distance for the bus line: Depends on the network cover area
Maximum distance between controller to the PC: No limit

LT
D
AC-ASP8002

AC
Two Door Controller

C
ES
Wiring Guide

S
SE
C
U
R
IT
Y
PR
O
D
U
C
TS
LT
D
AC
C
ES
Network Access Control

S
SE
AC-ASP8000
PC BASED ACCESS CONTROL SYSTEM
PC Access Control for single,

C
double or Multi door
installations Via LAN or WAN

U
connection providing Access
Control and time and

R
attendance monitoring.

IT
Key features:
20,000 users
Up to 100,000 offline events

Y
Expandable to unlimited doors
Windows 8 Compatible

PR
Reader in and/or Out
Simple Configuration with user
friendly step by step set up
Controllers can be mounted in

O
supplied boxed Power Supplies.

D
AC-ASP Part Numbers:
AC-ASP8001 - 1 Door Controller

U
AC-ASP8002 - 2 Door Controller
AC-ASP-SW8 - Software

C
AC-ASP-SR2 - Prox Reader
AC-ASP-KR3W - Pin/Prox Pad

TS
AC-ASP-R3 - Prox reader
AC-ASP-RLF - Alarm Relay

LT
D

You might also like