SCHEDULE OF BEAMS

C13 C14 C15 BOTTOM REINFORCEMENT TOP REINFORCEMENT


BEAM SIZE IN MM STIRRUPS REMARKS
LEFT MID RIGHT LEFT MID RIGHT

B1 230 550 2-T20 2-T20 2-T20 2-T16 2-T16 2-T16 T8@200,200,200C\C


+ 2-T16 + 2-T16 + 2-T16 + 2-T12

B2 230 450 2-T16 2-T16 2-T16 2-T12 2-T12 2-T12 T8@200,200,200C\C


S5
ST B3 230 450 3-T12 3-T12 3-T12 2-T10 2-T10 2-T10 T8@200,200,200C\C
B6 C11 B7 B8
C10
B10

C12 S5 B4 230 450 2-T16


+ 2-T16
2-T16
+ 2-T16
2-T16
+ 2-T16
2-T10 2-T10 2-T10 T8@200,200,200C\C

B13
S5
B5 230 450 2-T16 2-T16 2-T16 2-T10 2-T10 2-T10 T8@200,200,200C\C
+ 2-T12 + 2-T12 + 2-T12
C7 C8 C9
B5 B6 230 450 2-T12 2-T12 2-T12 2-T16 2-T16 2-T16 T8@125,125,125C\C CANTILEVER
+ 2-T12 + 2-T12 + 2-T12
S5 S4

B16
S1 B7 230 450 3-T12 3-T12 3-T12 2-T16 2-T16 2-T16 T8@150,200,150C\C
+ 2-T12 + 2-T12

B12
B9

S5 B8 230 450 2-T12 2-T12 2-T12 2-T16 2-T16 2-T16 T8@125,125,125C\C CANTILEVER
+ 2-T12 + 2-T12 + 2-T12
B4
B9 230 450 2-T16 2-T16 2-T16 2-T12 2-T12 2-T12 T8@200,200,200C\C CRANK BEAM
+ 2-T16
C6
B10 230 450 2-T12 2-T12 2-T12 2-T16 2-T16 2-T16 T8@125,125,125C\C CANTILEVER

S0
C5 + 2-T12 + 2-T12 + 2-T12
S2
C4 B1 B3 B11 230 450 3-T12 3-T12 3-T12 2-T10 2-T10 2-T10 T8@200,200,200C\C

B14

B15
S5
B11

B12 230 450 2-T16 2-T16 2-T16 2-T12 2-T12 2-T12 T8@200,200,200C\C CRANK BEAM
+ + 2-T16
2-T12
S3 S5 B13 230 450 2-T12 2-T12 2-T12 2-T16 2-T16 2-T16 T8@125,125,125C\C CANTILEVER
+ 2-T12 + 2-T12 + 2-T12

C1 C2 B2 C3 B14 230 450 3-T12 3-T12 3-T12 2-T10 2-T10 2-T10 T8@200,200,200C\C

S5 B15 230 450 3-T12 3-T12 3-T12 2-T10 2-T10 2-T10 T8@200,200,200C\C

B16 230 450 3-T12 3-T12 3-T12 2-T10 2-T10 2-T10 T8@200,200,200C\C CRANK BEAM

SCHEDULE OF SLABS
INDEX PLAN FOR RCC TERRACE FLOOR
SLAB THK. REINFORCEMENT REMARKS
IN MM SHORT SPAN LONG SPAN
S1 115 T8 @ 150 C/C ALT BENT UP T8 @ 250 C/C DIST. CRANK SLAB
S2 125 T8 @ 150 C/C ALT BENT UP T8 @150 C/C ALT BENT UP

S3 115 T8 @ 200 C/C ALT BENT UP T8 @ 250 C/C DIST.

S4 150 T8 @ 150 C/C ALT BENT UP T8 @150 C/C ALT BENT UP CRANK SLAB
S5 150 T12 @ 150 C/C ALT BAR T8 @ 200 C/C DIST.
CANTILEVER
BENT BACK ALONG BOTTOM TOP & BOTTOM
S0 125 T10 @ 150 C/C ALT BAR T8 @ 200 C/C DIST.
CANTILEVER
BENT BACK ALONG BOTTOM TOP & BOTTOM

NOTES :
1. ALL DIMENSIONS ARE IN MM EXCEPT OTHERWISE SPECIFIED,
2. BUILDING DESIGNED FOR (GROUND + 1) STORIES WITH L.L. 2KN/m2,
3. USE M:20 GRADE CONCRETE & Fe 500 STEEL,
4. S.B.C. OF FOUNDATION IS ASSUMED 300 kN / m^2,
5. PROVIDE CLEAR COVER OF 50 MM TO FOOTINGS , TITLE:
40 MM TO COLUMNS,25 MM TO BEAMS & 20 MM TO SLABS,
6. PROVIDE LAP / DEV. LENGTH 'Ld' AS FOLLOWS , R.C.C. DETAILS OF TERRACE FLOOR
BAR DIA. IN MM. Ø6 # 8 # 10 # 12 # 16
FOR TENSION STEEL 350 450 575 675 900 SCALE : N.T.S. DATE - 26.08.2020
FOR COMPRESSION STEEL 300 375 450 575 750 JOB NO. :200006