1 2 3 4 5 6

CIRCUIT DIAGRAM SHOWS OPERATING MECHANISM WHEN CIRCUIT BREAKER IS OPEN, WITHOUT PRESSURE, CLOSING SPRING NOT CHARGED AND HANDCRANK ADAPTED.
SCHEMAT VISAR MANÖVERDONET DÅ HÖGSPÄNNINGSBRYTAREN ÄR I FRÅNSLAGET LÄGE, EJ TRYCKSATT SAMT MED MANÖVERDONETS TILLSLAGSFJÄDER OSPÄND OCH HANDVEVEN APTERAD.
CIRCUIT BREAKER
BRYTARE
A A

CLOSE CIRCUIT
TILLKRETS
+S1 +S4
I REMOTE FJÄRR
- LOCAL LOKAL
O DISCONN. AVST.

+BW1 +BG1 +XC3 +Y3


+K3 1
CLOSE 1 +, REMOTE 14 11 23 24 21 22 1 2
+X1 +K9
TILL 1 +, FJÄRR 610 1 14 11 12
2 12 +BN
CLOSE 1 +, LOCAL
B TILL1 +, LOKAL 611 3 4 1 2 B

+
602 1 2

34 31
We reserve all rights in this document and in the in-

disclosure to third parties without express authority


formation contained therein. Reproduction, use or

32
+K3 +XC4
1
24 21 A1 A2
is strictly forbidden. c ABB

22
23 24
(-)
607
626 5 6

C C

CLOSE 1 -
TILL 1 - 625

CLOSING SPRING CHARGED


TILLSLAGSFJÄDER SPÄND

BRYTARE TILL
BREAKER ON
D D

Based on 1HSB543260-AAC Prepared 2015-01-14 Gutman Anton Circuit Diagram KRETSSCHEMA CD


Approved 2015-01-14 Hellsten Sara OPERATING MECHANISM MSD +MSD.1
MANÖVERDON MSD Resp dept PPHB/BOD Rev ind B Lang sv
Sheet 1/10
1HSB543260-AAD
Cont 2
1 2 3 4 5 6
1 2 3 4 5 6

TRIP CIRCUIT 1
+S1 +S4 +K9 +BW1 +BG1
FRÅNKRETS 1

TRIP CIRCUIT SUPERVISION +X1


FRÅNKRETSÖVERVAKNING 688 01 02
A A

TRIP 1 +, REMOTE +Y1


FRÅN 1 +, FJÄRR 630 7 24 21 03 04 1 2
TRIP 1 +, LOCAL 8 22
FRÅN 1 +, LOKAL 631 5 6
+
600 3 4 17 18
601
+X2
61 +Y7 +BW1 +Q1
62 13 14 1 2 11 12 A1 A2

21[3]
B B
+BD1
23 22[4]

66 A1 A2
We reserve all rights in this document and in the in-

disclosure to third parties without express authority


formation contained therein. Reproduction, use or

+X1
CLOSE & TRIP CIRCUIT 1 BLOCKED 872
is strictly forbidden. c ABB

TILL & FRÅNKRETS 1 BLOCKERADE 873 34 31


32

- +X0
605 5
606
C (TRIP 1 -) C
(FRÅN 1 -) 645 6

652 7 8
653

I
-
O

CLOSING SPRING CHARGED


TILLSLAGSFJÄDER SPÄND

BRYTARE TILL
BREAKER ON
Q1
B

Y7
A
4

7
D D

Based on 1HSB543260-AAC Prepared 2015-01-14 Gutman Anton Circuit Diagram KRETSSCHEMA CD


Approved 2015-01-14 Hellsten Sara OPERATING MECHANISM MSD +MSD.1
MANÖVERDON MSD Resp dept PPHB/BOD Rev ind B Lang sv
Sheet 2/
1HSB543260-AAD
Cont 3
1 2 3 4 5 6
1 2 3 4 5 6

TRIP CIRCUIT 2
FRÅNKRETS 2 +S4 +BW1 +BG1

TRIP CIRCUIT SUPERVISION +X1


FRÅNKRETSÖVERVAKNING 788 11 12
A A

TRIP 2 +, REMOTE +K10 +Y2


FRÅN 2 +, FJÄRR 730 9 14 11 13 14 1 2

TRIP 2 +, LOCAL 10 12
FRÅN 2 +, LOKAL 731 11 12

34 31
+ 700
32
701

+X2
71
B B

31[5]

+BD1
33 32[6]
We reserve all rights in this document and in the in-

disclosure to third parties without express authority


formation contained therein. Reproduction, use or

is strictly forbidden. c ABB

76 A1 A2

+X1
TRIP CIRCUIT 2 BLOCKED 960
FRÅNKRETS 2 BLOCKERAD 961 24 21
C 22 C

+X0
- 705 15
706

(TRIP 2 -)
(FRÅN 2 -) 745 16

CLOSING SPRING CHARGED


TILLSLAGSFJÄDER SPÄND

BRYTARE TILL
BREAKER ON
D D

Based on 1HSB543260-AAC Prepared 2015-01-14 Gutman Anton Circuit Diagram KRETSSCHEMA CD


Approved 2015-01-14 Hellsten Sara OPERATING MECHANISM MSD +MSD.1
MANÖVERDON MSD Resp dept PPHB/BOD Rev ind B Lang sv
Sheet 3/
1HSB543260-AAD
Cont 4
1 2 3 4 5 6
1 2 3 4 5 6

2
SIGNAL CONTACTS
+S4 +BW1 +BG1
SIGNALKONTAKTER

B
+X1
902
903 13

CLOSING SPRING CHARGED


14

TILLSLAGSFJÄDER SPÄND
A 904 15 16 A

BRYTARE TILL
905 19 20

BREAKER ON
+X2
51 REMOTE FJÄRR
LOCAL LOKAL
DISCONN. AVST.

11[1]

+BD1
13 12[2]

+K25

56 A1 A2

B B
+X1
870
871 14 11
12

3 4
We reserve all rights in this document and in the in-

disclosure to third parties without express authority


formation contained therein. Reproduction, use or

886 13 14
887
888 21 22
is strictly forbidden. c ABB

889
890 33 34
891
892 31 32
893
C C

D D

Based on 1HSB543260-AAC Prepared 2015-01-14 Gutman Anton Circuit Diagram KRETSSCHEMA CD


Approved 2015-01-14 Hellsten Sara OPERATING MECHANISM MSD +MSD.1
MANÖVERDON MSD Resp dept PPHB/BOD Rev ind B Lang sv
Sheet 4/
1HSB543260-AAD
Cont 5
1 2 3 4 5 6
1 2 3 4 5 6

AUXILIARY CONTACTS
HJÄLPKONTAKTER +BG1

+X1
201 31 32
A A
202
203 33 34
204
211 41 42
212
213 43 44
214
221 51 52
222
223 53 54
224
231 61 62
232
233 63 64
B B
234
241 71 72
242
243 73 74
244
251 81 82
We reserve all rights in this document and in the in-

disclosure to third parties without express authority


formation contained therein. Reproduction, use or

252
253 83 84
254
is strictly forbidden. c ABB

261 91 92
262
263 93 94
264
271 101 102
C 272 C
273 103 104
274
281 111 112
282
283 113 114
284

BRYTARE TILL
BREAKER ON
D D

Based on 1HSB543260-AAC Prepared 2015-01-14 Gutman Anton Circuit Diagram KRETSSCHEMA CD


Approved 2015-01-14 Hellsten Sara OPERATING MECHANISM MSD +MSD.1
MANÖVERDON MSD Resp dept PPHB/BOD Rev ind B Lang sv
Sheet 5/
1HSB543260-AAD
Cont 6
1 2 3 4 5 6
1 2 3 4 5 6

AUXILIARY CONTACTS
HJÄLPKONTAKTER +BG2

+X1
291 201 202
A A
292
293 203 204
294
301 211 212
302
303 213 214
304
311 221 222
312
313 223 224
314
321 231 232
322
323 233 234
B B
324
331 241 242
332
333 243 244
334
341 251 252
We reserve all rights in this document and in the in-

disclosure to third parties without express authority


formation contained therein. Reproduction, use or

342
343 253 254
344 18-POLE
is strictly forbidden. c ABB

18-POLIG

BRYTARE TILL
BREAKER ON
C C

D D

Based on 1HSB543260-AAC Prepared 2015-01-14 Gutman Anton Circuit Diagram KRETSSCHEMA CD


Approved 2015-01-14 Hellsten Sara OPERATING MECHANISM MSD +MSD.1
MANÖVERDON MSD Resp dept PPHB/BOD Rev ind B Lang sv
Sheet 6 /10
1HSB543260-AAD
Cont 7
1 2 3 4 5 6
1 2 3 4 5 6

2
MOTOR CIRCUIT

Q1
Y7
MOTORKRETS

A A

+X1 +F1
878 21 22 +Q1
879
21 22
+Y7
13 14 1 2 21 22
+M1
+X0
3 4 45 1 M 2
L/+ 450 1 2 ~
451 3 4

I>
N/- 465 5 6 5 6 46
466
B B

1
0
+BT1

+F2
We reserve all rights in this document and in the in-

disclosure to third parties without express authority


formation contained therein. Reproduction, use or

AC AUX. CIRCUIT 884 21 22


+E2
VÄXELSTRÖMSKRETS 885 1 2 1 2
13 14
is strictly forbidden. c ABB

+XC1
1 +E1
L 500 1 2 1 2
I>

501

C C
1
0

+XC2
1
N 515
516
+X4 +XC1 +E3
2 +BX
1 21 22 X1 X2
13 14
2
+XC2
PE 2
PE

D D

Based on 1HSB543260-AAC Prepared 2015-01-14 Gutman Anton Circuit Diagram KRETSSCHEMA CD


Approved 2015-01-14 Hellsten Sara OPERATING MECHANISM MSD +MSD.1
MANÖVERDON MSD Resp dept PPHB/BOD Rev ind B Lang sv
Sheet 7/
1HSB543260-AAD
Cont 8
1 2 3 4 5 6
1 2 3 4 5 6

CIRCUIT DIAGRAM SHOWS OPERATING MECHANISM WHEN CIRCUIT BREAKER IS OPEN, WITHOUT PRESSURE, CLOSING SPRING NOT CHARGED AND HANDCRANK ADAPTED.
SCHEMAT VISAR MANÖVERDONET DÅ HÖGSPÄNNINGSBRYTAREN ÄR I FRÅNSLAGET LÄGE, EJ TRYCKSATT SAMT MED MANÖVERDONETS TILLSLAGSFJÄDER OSPÄND OCH HANDVEVEN APTERAD.

ITEM DESIGNATION ITEM DESIGNATION


POS. BENÄMNING POS. BENÄMNING
A A
BD1 DENSITY SWITCH 2) S1 CONTROL SWITCH (TRIP/CLOSE)
DENSITETSVAKT 2) MANÖVERSTÄLLARE (FRÅN/TILL)

BG1-2 AUXILIARY CONTACT


HJÄLPKONTAKT

BN COUNTER S4 SELECTOR SWITCH (OPERATION)


RÄKNEVERK OMKOPPLARE (MANÖVER)
X0 TERMINAL BLOCK (INTERNAL)
BT1 THERMOSTAT
KOPPLINGSPLINT (INTERN)
TERMOSTAT
X1 TERMINAL BLOCK (EXTERNAL)
BW1 LIMIT SWITCH KOPPLINGSPLINT (EXTERN)
GRÄNSSTÄLLARE
X2 TERMINAL BLOCK (INTERNAL) (GAS SUPERVISION) 2)
BX DOOR SWITCH (ILLUMINATION) KOPPLINGSPLINT (INTERN) (GASÖVERVAKNING) 2)
DÖRRKONTAKT (BELYSNING)
X4 SOCKET OUTLET (SCHUKO)
E1 HEATER (CONTINUOUS CONNECTED) STICKPROPPSUTTAG (SCHUKO)
VÄRMEELEMENT (KONTINUERLIGT INKOPPLAD) XC1-4 TERMINAL BLOCK (INTERNAL)
B KOPPLINGSPLINT (INTERN) B
E2 HEATER (THERMOSTAT CONTROLLED)
VÄRMEELEMENT (TERMOSTATSTYRD)
E3 LAMP (ILLUMINATION)
LAMPA (BELYSNING)

F1 DIRECT-ON-LINE MOTORSTARTER
MOTORSKYDDSBRYTARE
Y1 SHUNT TRIP COIL 1
We reserve all rights in this document and in the in-

disclosure to third parties without express authority


formation contained therein. Reproduction, use or

F2 MINIATURE CIRCUIT BREAKER (AC-CIRCUIT)


DVÄRGBRYTARE (VÄXELSTRÖMSKRETS) FRÅNSLAGSMAGNET 1

K3 ANTIPUMPING RELAY Y2 SHUNT TRIP COIL 2


FRÅNSLAGSMAGNET 2
is strictly forbidden. c ABB

ANTIPUMPRELÄ
Y3 CLOSING COIL 1
TILLSLAGSMAGNET 1
K9 INTERLOCKING RELAY (GAS SUPERVISION) (CLOSE / TRIP 1) Y7 BLOCKING CONTACT (HANDCRANK ADAPTED)
FÖRREGLINGSRELÄ (GASÖVERVAKNING) (TILL/FRÅN 1) BLOCKERINGSKONTAKT (VEV APTERAD)
K10 INTERLOCKING RELAY (GAS SUPERVISION) (TRIP 2)
FÖRREGLINGSRELÄ (GASÖVERVAKNING) (FRÅN 2)
C C

K25 AUXILIARY RELAY (GAS SUPERVISION) (ALARM)


HJÄLPRELÄ (GASÖVERVAKNING) (LARM)

M1 MOTOR
MOTOR

Q1 CONTACTOR
KONTAKTOR
D D
2) TO BE CONNECTED ON SITE WHEN INSTALLING.
2) ANSLUTES PÅ MONTAGEPLATSEN I SAMBAND MED INSTALLERING.
Based on 1HSB543260-AAC Prepared 2015-01-14 Gutman Anton Circuit Diagram KRETSSCHEMA CD
Approved 2015-01-14 Hellsten Sara OPERATING MECHANISM MSD +MSD.1
MANÖVERDON MSD Resp dept PPHB/BOD Rev ind B Lang sv
Sheet 8/
1HSB543260-AAD
Cont 9
1 2 3 4 5 6
We reserve all rights in this document and in the in-
formation contained therein. Reproduction, use or
disclosure to third parties without express authority

B
D

A
is strictly forbidden. c ABB

Based on
1HSB543260-AAC
INT.1 +X0 +X0 INT.2 INT. +X1 +X1 EXT.
5
6 450
15 451
1

1
16

PLINTARRANGEMANG (LODRÄT MONT.)


TERMINAL ARRANGEMENT (VERTICAL MOUNT.)
465
45
46 466
SPARE 500
SPARE
501
EXT. +X1 +X1 INT. 515
201 516
202
203 600
204 601
211 602
212
213 605
214 606
221 607
222
223 610
224 611
231 625
232
233 626
234 SPARE
241 630
242
243 631
244 SPARE
2

2
251 SPARE
252
645
253
254 652
261 653
262
688
263
264 SPARE
271 700
272
273 701
Prepared
Approved

274 705
281 706
282
283 SPARE
284 SPARE
2015-01-14
2015-01-14

291 SPARE
292
293 SPARE
294 730
301 731
302
303 SPARE
304 745
311 788
Hellsten Sara
Gutman Anton

312
313 SPARE
3

3
314 SPARE
321 870
322 871
323 872
324 873
331 SPARE
332 SPARE
333 SPARE
334 SPARE
341 878
342 879
343 884
344 885
886
887
888
889
890
891
892
893
902
903
MANÖVERDON MSD
OPERATING MECHANISM MSD
Circuit Diagram

904
905
960
961
SPARE
4

4
SPARE
SPARE
SPARE
INT. +X2 +X2 EXT.
51
56
61
62
KRETSSCHEMA

66
71
76
Resp dept

CD
5

5
1HSB543260-AAD

PPHB/BOD
Rev ind

+MSD.1
B
6

6
Cont

Lang
Sheet

sv
R1
9/

B
D

A
1 2 3 4 5 6

List of Revisions

Rev Index Revision text Date Prepared Approved

A A First edition. 2014-08-26 Gutman Anton Hellsten Sara A

B PE changed. 2015-01-14 Gutman Anton Hellsten Sara

B B
We reserve all rights in this document and in the in-

disclosure to third parties without express authority


formation contained therein. Reproduction, use or

is strictly forbidden. c ABB

C C

D D

Based on 1HSB543260-AAC Prepared 2015-01-14 Gutman Anton Circuit Diagram KRETSSCHEMA CD


Approved 2015-01-14 Hellsten Sara OPERATING MECHANISM MSD
MANÖVERDON MSD Resp dept PPHB/BOD Rev ind B Lang sv
Sheet R1/
1HSB543260-AAD
Cont

1 2 3 4 5 6