TT412 & TT12A-TT12C

selec Operating Instructions


TERMINAL CONNECTIONS MECHANICAL INSTALLATION L
N MACHINE
Panel cutout
OP186-V04

STRT/ Outline Dimensions (in mm) (in mm)


+12V HLD +12V RST COM CONFIG N L

TT412
L 1/6/1
1 2 3 4 5 6 7 8 9 10 11 12 TT412/TT12/TT12C
2/8/4
N
+ A D F
RANGE SELECTION PROGRAMMING :
B G
TERMINALS DESCRIPTION E
C 1) Short terminal no 5 & 6 (For TT412),
1 +12V Short terminal no 3 & 4 (For TT12A),
2 STRT/ HLD MODELS DIM A B C D E F G Short terminal no 6 & 7 (For TT12C)
48 X 96
+12V supply
2) Turn power on
36 X 72 3 TT412 33 75 74.5 28 3.5 29 71
Reset input
3) Program range setting as per instructions below:
3-4
TT12A 48 96 123 45 10 46 92
5 COM (GND) KEY PRESS DISPLAY DESCRIPTION
SPECIFICATIONS 5-6 Short to enter Configuration TT12C 50 97.5 88 45 10 46 92
DISPLAY
10 N-Neutral (-)
OPERATION Range
Blinking
* Least count = 0.1 sec.
12 L-Live (+) Range = 99999.9 sec.
0.3’’, 7 segment LED ( 6 digits ) For TT412
0.5’’, 7 segment LED ( 6 digits ) For TT12 STRT/ The TT412 / TT12A / TT12C totalises time Press Least count = 1 sec.
RST HLD +12V COM
RANGE when STRT/HLD terminals are shorted (TT412:1-2, Range = 999999 sec.
a) 99999.9 sec b) 999999 sec c) 99999.9 min 1 2 3 4 5 6 7 8 9 TT12A: 8-6, TT12C: 1-4). When operated, the display Press Least count = 0.1 min.
TT12A
d) 999999 min e) 99999.9 hrs f) 999999 hrs LOCK/CONFIG advances by 1 count at every interval of selected Range = 99999.9 min.
ACCURACY least count. The display indicates the cumulative
Better than 0.05 % Press Least count = 1 min.
total of the time for which the instrument is operated.
SETTING Range = 999999 min.
10 11 12 13 14 15 16 N L The time totaliser is used primarily for measuring
Via key on front panel Press Least count = 0.1 hrs.
INPUT - + running/operating time of continuously operating
machines. The connections for such an application Range = 99999.9 hrs.
Potential free contact TERMINALS DESCRIPTION
RESET is given below : Press Least count = 1 hrs.
Via rear terminals 3
LOCK/CONFIG
TYPICAL APPLICATION Range = 999999 hrs.
RESET TIME 4
20 ms. 5 Reset input CASE1 : TT412 / TT12A / TT12C operated by After selecting appropriate code:
MEMORY RETENTION 6 STRT/ HLD 1) Turn power off
external contact
10 years 8 +12V supply 2) Remove link between terminal no 5 & 6
1) The display will be continuously ON. (For TT412),
CONFIGURATION LOCK COM (GND)
9 2) The time displayed on TT412 / TT12A / TT12C
Via rear terminals to avoid inadvertent Remove link between terminal no 3 & 4
change in configured parameters N N-Neutral (-) will be indicative of the time for which the (For TT12A)
POWER SUPPLY L L-Live (+) machine is ON. Remove link between terminal no 6 & 7
90 to 270V AC/ DC, 3) A PNP proximity sensor can be used instead of (For TT12C)
@50/60 Hz, 1.0VA 24V AC/DC STRT/ +12V RST COM CONFIG (Short 6 & 7) a switch. 3) Turn power on. Display resets to 0 & start
MOUNTING HLD 4) Connect proximity switch between terminals functioning as per selection.
Panel mounting 1-2 ( for TT412 ), 8-6 (for TT12A) and terminals
OPERATING TEMP. 1 2 3 4 5 6 7 8 9 10 TO READ RANGE ( for 3 sec )
1-4 ( for TT12C).
0 - 50oC
TT12C

22 COM
24 KEY PRESS
R DISPLAY DESCRIPTION
HUMIDITY (MOMENTARY)
Y
95% RH 21 23 MACHINE Range code is
B
HOUSING displayed for
ABS Plastic 11 12 13 14 15 16 17 18 N L EXTERNAL CONTACT L N RNG selected range
WEIGHT
TT412 - 95 gms - + 2/6/1
TT412/TT12A/TT12C
N
1/8/4
TT12A/TT12C - 225 gms ( Specifications are subject to change, since development is a
PRODUCT CODE: TERMINALS DESCRIPTION continuous process )
CASE2 : TT412/TT12A/TT12C operated only by
4-1 +12V - Start / Hold
MODELS BEZEL SIZE(mm) mains connection Selec Controls Pvt. Ltd.
5-6 Reset input
1) Short T1 & T2 terminals (For TT412), T6 & T8
TT12C 48 X 96 6-7 Short to enter Configuration
(For TT12A), T1 & T4 (For TT12C) Tel. No. : +91-22-40394200 / 40394202
3&6 COM (GND) Fax No. : +91-22-28471733 I Toll free : 1800 227 353
TT12A 48 X 96 2) Display will be on when power is applied to the
N N-Neutral (-) Website: www.selec.com I Email: sales@selec.com
machine in this case & will display the time for
TT412 36 X 72 L L-Live (+) which the machine is ON. Doc. Name: Operating/1105/TT412 & TT12A-TT12C OP186-V04
(Page 1 of 1)