Pipe Outer Diameter Meters OD 0.073 Service Fluid temperature (Assumed) Deg C < 50 Design Life Years T 2 Coating Break down Failure Area in percentage % CBP 10 Coating Break down Factor Number CBF 0.1 Safety Factor Number SF 2 Surface Area Square Meters SA Pi x OD x L = 3.14 x 0.073 x 1000 SA 229.3362637
Current Density A/m² icm 0.05 Table 5-1 of DNV-RP-F103
Anode Type Al-Zn-In Preferred DNV-RP-F103, para 5.4.2 The anode utilization factor u (dimensionless) shall be selected according to ISO Utilization factor Number UF 0.8 15589-2, Sec. 7.4; anode electrochemical capacity ( Electrochemical Capacity A·h/kg E. Cap 2000 DNV-RP-F103, para 5.4.1) Anode Width cm AW 13.0 (from Anode Data Sheet) Anode Height cm AH 5.0 (from Anode Data Sheet) Anode Length cm AL 100.0 (from Anode Data Sheet) row ohms CM row 20 Required Voltage V RV 0.8 Anode OCP V OCP 1.05 Anode Weight Kg Awt 15 (from Anode Data Sheet)
Require Current amps I SA x CBF x icm x SF
= 229 x 0.1 x 0.050 x 3 I 2.293362637
Required Anode Weight Kg RAW (I x T x 8760 ) / (UF x E. Cap)
= (2.29 x 2 x 8760) / (0.80 x 2000) Required Anode Weight Kg RAW 25.1232088 Lx W x H = 100 mm X 130 Anode Weight Kg AW 15 mm X 50 mm Radius Cm Rad = (130 + 50) / 3.14 = 57.48 mm or 5.75 CM Resistance of anode to remote earth. ohms Rg = (P/ 2 pi L) ((ln 4L/r)-1) = (20 / (2 x 3.14 x 92))/ (ln (4x100)/5.73 -1) 0.031 x 3.25 Ohms 0.100 Signle Anode O/P current Amps = Driving Voltage / Rg = 0.250 / 0.100 = 2.5 Amps
Number of Anodes Required By = Required Weight / Single Anode
Weight Number N Weight = 25.1 / 15 = 1.67 Anodes =2
Number of Anodes Required
based on single Anode O/P Total Current Required / Single Current N Anode O/P current 2.293 / 2.5 Anodes =1 Lx W x H = 100 mm X 130 Number Anodes Required 2 mm X 50 mm