You are on page 1of 1

2" X 2" LAUAN CEILING JOIST

SP. @ 0.60 M O.C.B.W.

END GUTTER
END OF CEILING FRAMING

TRUSS 2 TRUSS 2
0.62 0.62

TRUSS 1 TRUSS 1
TRUSS 1
1.5" X 3mm THK. ANGLE BAR CHORD
STRUTT

0.20

STRUTT
STRUTT
END GUTTER

1.5" X 3mm THK. ANGLE BAR WEB

END GUTTER
STRUTT

END OF CEILING FRAMING


TRUSS 3
3 STEEL FACIA BRACKET DETAIL
STRUTT TRUSS 3
S-2 SCALE 1:10M

END OF CEILING FRAMING


1.20
STRUTT

TRUSS 2

STRUTT
2" X 2" LAUAN CEILING HANGERS
SP. @ 1.20 M O.C.

END OF CEILING FRAMING VARIES


END GUTTER

STRUTT

6 mm THK. MARINE PLYWOOD


ARRANGE IN A RUNNING BOND LAYOUT
TRUSS 2 TRUSS 2
2" X 2" LAUAN CEILING JOIST
SP. @ 0.60 M O.C.
END OF CEILING FRAMING
2" X 2" LAUAN CEILING JOIST
END GUTTER SP. @ 0.60 M O.C.B.W.

4 CEILING FRAMING CROSS SECTION


S-2 SCALE 1:10M

2 CEILING FRAMING PLAN


1 ROOF FRAMING PLAN S-2 SCALE 1:75M
S-2 SCALE 1:75M

6.00 3.00

2l - 2" x 4" x 3mm THK,. WEB MEMBERS 0.80


(EPOXY PRIMER FINISH) 2l - 2" x 4" x 3mm THK,. WEB MEMBERS
2l - 2" x 6" x 3mm THK,. CHORD 2l - 2" x 4" x 3mm THK,. WEB MEMBERS
2l - 2" x 6" x 3mm THK,. CHORD (EPOXY PRIMER FINISH)
(EPOXY PRIMER FINISH) (EPOXY PRIMER FINISH)
(EPOXY PRIMER FINISH)
2l - 2" x 6" x 3mm THK,. CHORD
(EPOXY PRIMER FINISH)

1.50
2l - 2" x 6" x 3mm THK,. VERTICAL MEMBER 1.50
(EPOXY PRIMER FINISH)
2l - 2" x 6" x 3mm THK,. VERTICAL MEMBER
6 mm THK. MARINE PLYWOOD (EPOXY PRIMER FINISH)
ARRANGE IN A RUNNING BOND LAYOUT

2l - 2" x 6" x 3mm THK. BOTTOM CHORD 2l - 2" x 6" x 3mm THK. BOTTOM CHORD
(EPOXY PRIMER FINISH) (EPOXY PRIMER FINISH)

6 mm THK. MARINE PLYWOOD


ARRANGE IN A RUNNING BOND LAYOUT
6 mm THK. MARINE PLYWOOD
ARRANGE IN A RUNNING BOND LAYOUT
2l - 2" x 6" x 3mm THK. BOTTOM CHORD 2" X 2" LAUAN CEILING JOIST
(EPOXY PRIMER FINISH) 2" X 2" LAUAN CEILING HANGERS 2" X 2" LAUAN CEILING JOIST
SP. @ 0.60 M O.C. SP. @ 1.20 M O.C.
2" X 2" LAUAN CEILING JOIST SP. @ 0.60 M O.C. 2" X 2" LAUAN CEILING HANGERS
SP. @ 0.60 M O.C. SP. @ 1.20 M O.C.

2" X 2" LAUAN CEILING HANGERS


3 TRUSS 1 DETAILS TRUSS 2 DETAILS
SP. @ 1.20 M O.C.
S-2 SCALE 1:75M 4 5 TRUSS 3 DETAILS
S-2 SCALE 1:75M S-2 SCALE 1:75M

PREPARED BY: APPROVED BY: PROJECT TITLE: SHEET CONTENT: SHEET NO.:
REPUBLIC ACT 9266 ARTICLE IV SECTION 33

ROOF FRAMING PLAN Drawings and specifications and other contract


TRUSS DETAILS 1 documents duly signed, stamped or sealed, as
UNIVERSITY OF THE IMMACULATE CONCEPTION instruments of service, are the intellectual property

S-2
TRUSS DETAILS 2
BONIFACIO STREET, DAVAO CITY, PHILIPPINES
TEL. NO.: 227-1573 LOCAL 222
CONSTRUCTION OF 1-STOREY TRUSS DETAILS 3
and documents of the author, whether the object for
which they are made is executed or not. It shall be
unlawful for any person to duplicate or to make copies
FAX NO.: (63-082) 226-2676 CEILING FRAMING PLAN
http://www.uic.edu.ph RESIDENTIAL BUILDING CEILING FRAMING
of said documents for use in the repetition of and for
other projects or buildings, whether executed partly or
in whole, without the written consent of the author of
CROSS SECTION
CHRISTIAN JOHN A. SALUDAR ENGR. JOSEPH ALLAN A. PANTINOPLE LOCATION
STEEL FACIA BRACKET DETAIL
said documents.All authors shall incorporate this
provision in all contract documents and other
CE-2A CAD INSTRUCTOR instruments of service.