ASSUMPTION AND DESIGN CONCEPT

A. ANALYSIS

THE ANALYSIS WAS CARRIED OUT IN ACCORDANCE WITH NATIONAL STRUCTURAL CODE OF THE
PHILIPPINES (NSCP 2015). A THREE DIMENSIONAL MODEL WAS USED IN
STRUCTURAL ANALYSIS AND DESIGN OF THE STRUCTURE USING MIDAS GEN.

B. STRUCTURAL FRAMING SYSTEM

THE STRUCTURAL FRAMING SYSTEM SHALL BEHAVE AS A CONCRETE FRAME WITH


BEARING WALL SYSTEM. THE FRAMING SYSTEM IS COMPOSED OF BEARING WALL AND CONCRETE FRAMES
DETAILED TO TRANSMIT BOTH GRAVITY AND LATERAL LOADS TO FOUNDATION.

C. FOUNDATION

THE BASEMENT SLAB IS USTILIZED AS THE MAT FOUNDATION OF THE STRUCTURE WHICH IS 3m FROM
THE NATURAL GRADE LINE. BASED ON THE ACTUAL SOIL INVESTIGATION REPORT, EXISITNG SOIL
BEARING CAPACITY IS 65 Kpa. BASED ON THE SUBSURFACE CONDITION AND THE MATERIAL FOUND IN
THE AREA, THE 500mm THICK SOIL LAYER UNDER THE MAT FOUNDATION SHALL BE COMPACTED TO
REACH A BEARING
CAPACITY OF 100KPa

DESIGN LOADS

A. DEAD LOAD

1) SELFWEIGHT: SUMMATION OF ANY MEMBERS' SELF WEIGHT PRESENT IN THE STRUCTURE.


2) GROUN FLOOR LOADS: SHALL BE DIRECTLY APPLIED TO THE SOIL.
3) 2ND AND 3RD FLOOR: SHALL BE DISTRIBUTED IN TWO-WAY DIRECTION.

FLOOR FINISH = 1.00 Kpa MEPS = 0.10 Kpa


CEILING = 1.00 Kpa 200mm THK CHB = 4.40 Kpa

B. LIVE LOAD (NSCP2015)

RESIDENTIAL = 1.9 Kpa COMMERCIAL = 4.8 Kpa

C. WIND LOAD

1) AS PER NSCP WIND LOAD SECTION 3) MAXIMUM WIND SPEED OF 250 KPH
2) EXPOSURE B, ZONE II

D. SEISMIC LOAD

1) AS PER NSCP SEISMIC LOAD SECTION


PROJECT TITLE AND LOCATION: CERTIFIED: PRC REG NO.: 0132697
PTR NO.: 6705631
DATE ISSUED: 01/18/2019
PROPOSED FIVE STOREY WITH PLACED ANTIPOLO CITY
ISSUED:
MAVERIC M. ENRIQUEZ
BRGY. TEJEROS, MAKATI, MANILA CIVIL ENGINEER TIN NO.: 452-844-113-000