10-41 A steam power plant that operates on a reheat Rankine cycle is considered. The condenser pressure, the net power
output, and the thermal efficiency are to be determined.
Assumptions 1 Steady operating conditions exist. 2 Kinetic and potential energy changes are negligible.
Analysis (a) From the steam tables (Tables A-4, A-5, and A-6),
P3 12.5 MPa h3 3476.5 kJ/kg 3
T3 550C s 3 6.6317 kJ/kg K Boiler
Turbine
4
P4 2 MPa
h4 s 2948.1 kJ/kg 6
s 4 s s3
5
h3 h 4 Condenser
T
h3 h4 s 2 Pump
1
h4 h3 T h3 h4 s
3476.5 0.853476.5 2948.1
T
3027.3 kJ/kg
3 5
P5 2 MPa h5 3358.2 kJ/kg
T5 450C s5 7.2815 kJ/kg K 12.5 MPa
4s 4
P6 ?
h6 (Eq. 1) 2
x 6 0.95 2s
P6 ? P=?
h6 s (Eq. 2)
s 6 s5 1 6s 6
s
h h
T 5 6 h6 h5 T h5 h6 s 3358.2 0.853358.2 h6 s (Eq. 3)
h5 h6 s
The pressure at state 6 may be determined by a trial-error approach from the steam tables or by using EES from the above
three equations:
P6 = 9.73 kPa, h6 = 2463.3 kJ/kg,
(b) Then,
h1 h f @ 9.73 kPa 189.57 kJ/kg
v1 v f @ 10 kPa 0.001010 m 3/kg
w p ,in v1 P2 P1 / p
1 kJ
0.00101 m 3/kg 12,500 9.73 kPa
/ 0.90
3
1 kPa m
14.02 kJ/kg
Cycle analysis:
qin h3 h2 h5 h4 3476.5 203.59 3358.2 2463.3 3603.8 kJ/kg
PROPRIETARY MATERIAL. © 2011 The McGraw-Hill Companies, Inc. Limited distribution permitted only to teachers and educators for course
preparation. If you are a student using this Manual, you are using it without permission.