You are on page 1of 4

22 Oct 2020 17:45:10 - Deflection Short term and Long term.

sm
Calculation of Deflection for B16 of transfer floor.

Ref : Reinforced concrete design by Pillai Menon


Span of beam
L 23150 mm
Dimensions of Beam b 750 mm Properties of Material fy 500 MPa fck 35 MPa
d 2000 mm 5
Es 2 10 MPa
Maximum 1.5(dl+LL)=7556kNm as Mudl_ll 7556 kN m
per ETAB analysis
Mudl_ll Mdl Msls 881 kN m 4156.3333 kN m
Msls 5037.3333 kN m
1.5
Mll Msls Mdl 881 kN m
cov 50 mm
0.5
fck
Ec 5000 MPa 29580.3989 MPa
MPa

Reinforcement Data 2 d_bar 32 mm


Ast 27336 mm fck
Ast
pt 100 1.8224 fcr 0.7 MPa 4.1413 MPa
b d MPa
2
Asc 7000 mm
d_bar
d1 cov
2
creep coefficient θ 1.6 for age at loading =28 days

ultimate shrinkage strain εcs 0.0003


clause 6.2.4.1 of IS 456
3
b d 4
Gross moment of Area Ig Igr 0.5 m
12
Ec
Effective modulus of elasticity Eceff 11377.0765 MPa
1 θ
Es
Short term modular ratio ms 6.7612
Ec
Es
Long term modular ratio ml 17.5792
Eceff

For Short term deflection

deff d cov d_bar 1.918 m


effective depth of beam
b
a1
2
b1 ms 1 Asc ms Ast

c1 ms 1 Asc cov ms Ast d

2
b1 b1 4 a1 c1
xu 0.73961905 m
2 a1

1/4
22 Oct 2020 17:45:10 - Deflection Short term and Long term.sm
second moment of area of the cracked - transformed section -Icr for Short term deflection
3
b xu 2 2 4
Icr ms 1 Asc xu d1 ms Ast deff xu 0.3761 m
3
ms Msls deff xu
taking moment about the NA fst 106.7127 MPa
Icr

Permissible compressive force = 0.33 fck 11.55 MPa


2
compressive force due to concrete Cc1 0.5 b xu 0.2774 m

1.5 ms 1 Asc xu d1
2
compressive force due to Reinforcement Cs1 0.0583 m
xu
Ast fst
compressive stress in concrete fc1 8.6912 MPa
Cc1 Cs1

fcr Igr
Cracking Moment clause as per Annexure C of IS 456 Mcr 2070.6279 kN m
d 0.5
xu
Neutral Axis Depth factor = k 0.3698
d
k
bw b j 1
3
bw
η j 1 k 0.5525
b
Icr 4
Ieff 0.3866 m
Mcr
1.2 η
Msls
4
Igr 0.5 m
Ifinal Min Ieff , Igr

2
Maximum Short term deflection (Cracked Section) 5 Msls L
Δdl_ll 14.0526 mm
84 Ec Ifinal
2
5 Mll L
Δll 2.4577 mm
84 Ec Ifinal
2
5 Mdl L
Δdl 11.5949 mm
84 Ec Ifinal
Properties for long term deflection.
b
a1lg
2
b1lg ml 1 Asc ml Ast

c1lg ml 1 Asc cov ml Ast d

2
b1lg b1lg 4 a1lg c1lg
xul 0.9965015 m
2 a1lg

second moment of area of the cracked - transformed section -Icr for Long term deflection

3
b xul 2 2 4
Icr.l ml 1 Asc xul d1 ml Ast deff xul 0.7559 m
3
Icr.l 4
Ieff.l 0.777 m 4
Mcr Ilg Min Ieff.l , Igr 0.5 m
1.2 η
Msls

2/4
22 Oct 2020 17:45:10 - Deflection Short term and Long term.sm

Long Term deflection due to shrinkage

Ast
pt 100 1.9003 k3 0.125
b deff

Asc pt pc 1.4137
pc 100 0.4866
b deff

2 Value of k4 as per Annexture C of IS456:2000


L
Δsh k3 k4
D if pt pc 0.25 pt pc 1 0.6666
pt pc
k4 Min 0.72 ,1
pt

k4 else
0.6666
if pt pc 1
2
L
Δsh k3 k4 εcs 6.6982 mm pt pc
d
k4 Min 0.65 ,1
pt
Long Term deflection due to creep
2 else
5 L
Δicr Mdl 40.7888 mm if pt pc 0
48 Eceff Ilg
k4 0
Δcr Δicr Δdl 29.1939 mm else
k4 1

Δlong Δsh Δcr 35.8921 mm

Δtot Δdl_ll Δsh Δcr 49.9447 mm

Δll_cp_sh Δll Δsh Δcr 38.3498 mm

3/4
22 Oct 2020 17:45:10 - Deflection Short term and Long term.sm
L
Δs_allow 92.6 mm
250

check for total deflection

if Δs_allow Δtot "ok in deflection"


"ok in deflection"
else
"not ok in deflection"

check for long term deflection


if 20 mm Δlong "not ok in long term deflection"
"ok in long term deflection"
else
"not ok in long term deflection"

4/4

You might also like