You are on page 1of 4

Company's Name:ABC Consultants Job No.

: ABC/1001
101, Known Street, Known Area, Known City, Pin …. Design by: UVW
Client: Very Important Industries Ltd, Well Known City Date: 14-Apr-21
Project: XYZ Building Page No. CF/101
SPREADSHEET OF
R.C. COMBINED FOOTINGS FOR TWO R.C. COLUMNS SUBJECTED TO
VERTICAL LOAD & MOMENTS BY WORKING STRESS METHOD AS PER IS:456-2000

Checks adequacy of the Footings of given size, with Concrete Grade,


type of Steel and SBC of soil, for the applied loads.

Concrete Grade = M 3
Yield Strength of Steel, fy (N/mm2) = 3
Modular Ratio DL+LL case (Wind/Seismic in bracket), m = 10.98 (8.24)
SBC of soil (Gross) at depth H below G.L.under DL + LL = 125 kN/m2
-Do- above under DL + LL + Wind/Seismic = 150 kN/m2
Density of dry soil, γsoil =
3
18 kN/m
Density of wet soil, if any (Approx.=0.6* γsoil + 10) 20.8 kN/m3

Main Inputs:
Footing Footing Size (m) Soil Depth(m) Column Size(m) Column Location (m)
Mk. L B t H H' h1 b1 h2 b2 a b c
CF1 7.00 4.00 0.75 1.00 0.00 0.30 0.30 0.30 0.30 1.50 4.00 1.50
CF2 6.00 3.00 0.75 1.50 1.00 0.30 0.30 0.30 0.30 1.00 4.00 1.00
CF3 8.00 4.50 0.90 1.50 0.00 0.50 0.40 0.40 0.40 2.00 5.00 1.00
RCDesignCD

CF4 9.00 4.00 0.60 1.00 0.00 0.45 0.45 0.45 0.45 1.50 6.00 1.50
CF5 6.00 2.50 0.45 1.00 0.00 0.30 0.30 0.30 0.30 1.00 4.00 1.00
Company's Name:ABC Consultants Job No.: ABC/1001
101, Known Street, Known Area, Known City, Pin …. Design by: UVW
Client: Very Important Industries Ltd, Well Known City Date: 14-Apr-21
Project: XYZ Building Page No. CF/102

Loads: Loads of Columns on top of footing Footing Soil Wt.


Footing P1 M1X M1Y H1X H1Y P2 M2X M2Y H2X H2Y Wt. over ftg. Load Case
Mk. (kN) (kNm) (kNm) (kN) (kN) (kN) (kNm) (kNm) (kN) (kN) (kN) (kN)
CF1 400 10 0 5 0 400 10 0 5 0 525.0 125.2 1
CF2 500 15 10 10 7 500 15 10 10 7 202.5 208.5 2
CF3 550 20 15 15 15 550 20 15 15 15 810.0 384.9 3
CF4 600 25 15 10 7 900 45 30 20 15 540.0 256.3 2
CF5 300 15 12 10 6 500 15 12 10 6 168.8 146.7 2

Bearing Pressures on Soil:


2
Centroid CG of V Total Loads on footing Bearing Pressures on Soil (kN/m ) Bending Moments (kNm) Eff. 'd'
Footing x loads, y P MX MY At At At At M11 Mx M22 Transv reqd.
Mk. (m) (m) (kN) (kNm) (kNm) I J K L (kNm) (kNm) (kNm) (kNm) (mm)
CF1 3.500 3.500 1450.2 27.5 0.0 50.32 53.27 50.32 53.27 123 -100 134 200 227
CF2 3.000 3.000 1411.0 45.0 30.5 75.08 85.08 71.69 81.69 77 -250 90 183 261
CF3 4.000 3.500 2294.9 617.0 57.0 42.08 87.79 39.71 85.41 104 -360 116 302 256
CF4 4.500 3.900 2296.3 988.0 58.2 23.70 106.03 21.54 103.87 23 -563 352 435 340
CF5 3.000 2.500 1115.5 439.0 29.4 6.08 146.56 2.16 142.64 -11 -200 145 150 256
Note: -ve sign of Bending Moment indicates tensile stress at top of footing

Bottom Reinforcement:
Cover to Bar Dia.(mm)Actual Reinforcement along 'L' at btm. Reinforcement along 'B' at btm.

Footing btm bars along along Eff.'d' Ast reqd. Provide Ast Ast reqd. Provide Ast
2 2 2
Mk. (mm) L' B' (mm) (mm ) Nos. Dia.(mm) Spacing (mm ) (mm ) Nos. Dia.(mm) Spacing (mm2)
CF1 75 20 16 665 3600 12 20 355 3770 6300 32 16 225 6434
CF2 75 20 16 665 2700 9 20 365 2827 5400 27 16 230 5429
CF3 50 20 20 840 4860 16 20 295 5027 8640 28 20 295 8796
CF4 75 20 16 515 2880 23 20 180 7226 6480 33 16 280 6635
CF5 75 20 12 365 1402 22 20 115 6912 3240 29 12 215 3280

RCDesignCD
Company's Name:ABC Consultants Job No.: ABC/1001
101, Known Street, Known Area, Known City, Pin …. Design by: UVW
Client: Very Important Industries Ltd, Well Known City Date: 14-Apr-21
Project: XYZ Building Page No. CF/103

Top Reinforcement:
Cover to Bar Dia.(mm)Actual Reinforcement along 'L' at top Reinforcement along 'B' at top
Footing top bars along along Eff.'d' Ast reqd. Ast Ast reqd. Ast
2 Provide 2 2 Provide 2
Mk. (mm) L' B' (mm) (mm ) (mm ) (mm ) (mm )
CF1 75 16 16 667 3600 18- 16dia.@230crs 3619 6300 32- 16dia.@225crs 6434
CF2 50 16 16 692 2700 14- 16dia.@225crs 2815 5400 27- 16dia.@230crs 5429
CF3 50 16 16 842 4860 25- 16dia.@185crs 5027 8640 43- 16dia.@190crs 8646
CF4 75 20 12 515 3863 13- 20dia.@325crs 4084 6480 58- 12dia.@160crs 6560
CF5 75 16 12 367 1927 10- 16dia.@270crs 2011 3240 29- 12dia.@215crs 3280

Shears X-X
100Ast/bd At d' from col. outer face At d' from col. inner face At '0.5d' from col. face

Footing Reinforcement V τv τc V τv τc V τv τc
2 2 2 2
Mk. along 'L' at Btm. (kN) (N/mm ) (N/mm ) (kN) (N/mm ) (N/mm ) (kN) (N/mm ) (N/mm2)
2

CF1 0.142 81.74 0.031 0.190 140.4 0.053 0.190 400 0.156 0.800
CF2 0.142 33.37 0.017 0.253 210.1 0.101 0.253 500 0.195 0.800
CF3 0.133 47.1 0.012 0.253 330.5 0.087 0.253 550 0.132 0.800
CF4 0.351 237.7 0.115 0.352 723.7 0.351 0.352 900 0.453 0.800
CF5 0.757 140.4 0.154 0.481 439.3 0.479 0.481 500 0.515 0.800

Shears Y-Y
At 'd' from col. face
Footing 100Ast/bd V τv τc
Mk. Reinf't along 'B' (kN) (N/mm2) (N/mm2)

CF1 0.142 207 0.046 0.190


CF2 0.140 182.8 0.047 0.253
CF3 0.134 254.3 0.039 0.253
CF4 0.148 395.6 0.088 0.253
CF5 0.157 192.5 0.092 0.247

RCDesignCD
Company's Name:ABC Consultants Job No.: ABC/1001
101, Known Street, Known Area, Known City, Pin …. Design by: UVW
Client: Very Important Industries Ltd, Well Known City Date: 14-Apr-21
Project: XYZ Building Page No. CF/104

Factor of Safety against Over-turning & Status of Design

Factor of Safety
Footing against Over-turning Overall Status of
Mk about X-X about Y-Y Design
CF1 176.294 N/A Section O.K.
CF2 91.326 67.372 Section O.K.
CF3 13.212 85.872 Section O.K.
CF4 9.185 76.174 Section O.K.
CF5 6.496 46.085 Section O.K.