You are on page 1of 2

Date Sheet

RONNIE & KOH CONSULTANTS PTE LTD 12/11/2020 1


Project : MCE C483 Designed by Checked by

Description : Tunnel box roof slab LEFT END 1 @ CH 0 + 150 ~ CH 0 + 190

CIRCULAR SECTION CRACK WIDTH CALCULATION TO CP73

Design Info:

Service Tension Force: Ns = 3096.0 kN (+ve for tension)


Service Moment: Ms= 18.0 kNm

Section Diameter Dia= 1400.0 mm

Reinforcement : 27 T40
Bar Spacing S : 146 mm

Concrete Steel
fcu = 40 N/mm2 fy = 460 N/mm2
Ec_s = 28000 N/mm2 Es = 200000 N/mm2
Ec_L = 14000 N/mm2 n=Es/Ec_l= 14.29
Cmin = 53 mm

acr: Distance from point considered to the nearest longitudinal bar

Crack Width Control Value: 0.3 mm

Computation of Moment Inertia of reinf.

Center of equivalent reinf. Ring, Rr= 1327 mm


Width of reinf.Ring, t= 4.07 mm
Ir= 2.9874.E+10 mm4
Zr= 2.2178E+07 mm3

Computation of Crack Width

Section Area A= 1539380 mm2


Area of reinf. As= 33929 mm2

Steel Stress fs= Ns/As+M/Zr = 92.06 N/mm2 <0.8fy, OK


Steel Strain εs = fs/Es = 0.000460
dist. from nearest rebar, acr = {(s/2)2+(Cmin+dia/2)2}0.5-dia/2 = 83.21 mm

Estimated Crack Width, W= 3acrεs = 0.115 mm OK


Date Sheet
RONNIE & KOH CONSULTANTS PTE LTD 12/11/2020 1
Project : MCE C483 Designed by Checked by

Description : Tunnel box roof slab LEFT END 1 @ CH 0 + 150 ~ CH 0 + 190

CIRCULAR SECTION CRACK WIDTH CALCULATION TO CP73

Design Info:

Service Tension Force: Ns = 3894.0 kN (+ve for tension)


Service Moment: Ms= 648.0 kNm

Section Diameter Dia= 1600.0 mm

Reinforcement : 31 T28
Bar Spacing S : 149 mm

Concrete Steel
fcu = 40 N/mm2 fy = 460 N/mm2
Ec_s = 28000 N/mm2 Es = 200000 N/mm2
Ec_L = 14000 N/mm2 n=Es/Ec_l= 14.29
fct= 0 N/mm2 Cmin = 53 mm

acr: Distance from point considered to the nearest longitudinal bar

Crack Width Control Value: 0.3 mm

Computation of Moment Inertia of reinf.

Center of equivalent reinf. Ring, Rr= 1533 mm


Width of reinf.Ring, t= 1.98 mm
Ir= 2.2430.E+10 mm4
Zr= 1.4499E+07 mm3

Computation of Crack Width

Section Area A= 2010619 mm2


Area of reinf. As= 19088 mm2

Steel Stress fs= (Ns-fct*(A-As))/As-M/Zr= 159.31 N/mm2 <0.8fy, OK


Steel Strain εs = fs/Es = 0.000797
dist. from nearest rebar, acr = {(s/2)2+(Cmin+dia/2)2}0.5-dia/2 = 86.04 mm

Estimated Crack Width, W= 3acrεs = 0.206 mm OK