Your Inlet Line Outlet Manhole

500
Ventilator
300
Ø2500
500 Ø200

Tank Inlet Pipe

Dividing Wall

2900
2900
4200

200 200

4600 2900
Install your tank according to instructions.
Tank Dimensions Alternative Tank Dimensions
Product is produced as fiberglass in specified dimensions like above. Width 2500 mm Width 2300 mm
There will be a divindg wall inside of tank that will support tank against to pressure. Height 2900 mm Height 2700 mm
There will be 2 pcs. lifters on tank , with that you can easily placed tank to underground. Thin Sand Lifters Length 4200 mm Length 5000 mm
There will be an inlet PVC pipe and an outlet mainhole (FRP) on tank. Concrete Ground
Rise Level 300 mm Rise Level 300 mm
There will be an airing pipe on tank, it will be support tank to don't poop inside of tank. EQUIPMENT LIST
You should placed tank to concrete ground that we draw on above. Diameter Height
The ground dimensions should be same that we clarified above. Excavation Dimensions Excavation Dimensions
Outlet Manhole Ø500 300 mm
If you need any changing on tank please contact with us. Width 2900 mm Width 2700 mm
Inlet Pipe Ø200 150 mm
Depth 3100 mm Depth 2900 mm
If rising level is more than 300mm, please contact us for new product! Strength of standart Ventilator Ø100 320 mm Length 4600 mm Length 5500 mm
tanks is designe according to 300mm.
Inlet pipe dimension and location can be changed Concrete Height 200 mm Concrete Height 200 mm
depending on your demand.