You are on page 1of 2

Check for punching shear

Slab data:

fc'= 21 mpa concrete comp. strength


Fy= 420 mpa steel yield strength
c1= 1100 mm column size parallel to bending
c2= 750 mm column size perpendicular to bending
ts= 500 mm slab total thickness
cb= 70 mm clear cover to bottom bar
d= 409 slab effectuve depth
dsb= 14 slab bot. bar diameter
dst= 14 slab top bar diameter
Column: Interior column location
Ø= 0.75 strength reduction factor for shear

Concrete strength in two way shear (vc):

b0= 5336 mm punching premeter


αs= 40
β= 1.466666667 ratio of long side : short side of column

Vc1= 1.51 mpa controls


Vc2= 1.84 mpa
Vc3= 1.93 mpa

Øvc= 1.13 mpa

Required strength in two way shear (vu):

RD= 300 Kn unfactored column dead load axial reaction


RL= 400 Kn unfactored column live load axial reaction
Ru= 1000 Kn factored column axial reaction
MD= 165 kn.m unfactored column dead load moment reaction
ML= 220 kn.m unfactored column live load moment reaction
Mu= 550 kn.m factored column moment reaction
WD= 0 kn/m2 applied unfactored uniform dead load on slab
WL= 0 kn/m2 applied unfactored uniform live load on slab
Wu= 0 kn/m2 factored uniform load on slab

Vu= 998.25 Kn required shear force for direct shear


vug= 0.46 mpa required shear stress for direct shear (without moment transfer)

ᴕf= 0.57 fraction of slab moment transferred by flexure


ᴕv= 0.43 fraction of slab moment transferred by eccentric shear
CAB= 754.50 mm centroid location from critical section

Jc= 791139122342.50 mm4


vu2= 0.23 mpa required shear stress for transfer of moment by eccentric shear
vu,AB= 0.684 mpa combined shear stress at column critical side
vu<Øvc…therefore shear rft not required