Data: Status of designe:
Exterior column load [KN].unfactored = 127 TRUE
Interior column load [KN].unfactored = 198 .
Load factor = 1.5
Distance between column center lines[m] = 3.1
Depth of foundation Df [m] = 0.4
Allowable bearing capacity of soil [KN/sq.m] = 150
Width of ext. col. In strap beam direction [m] = 0.5
Width of ext. col. In direct perpendicular strap beam [m] = 0.2
Width of int. col. In strap beam direction [m] = 0.5
Width of int. col. In direct perpendicular strap beam [m] = 0.2
Breadth of strap beam [m] = 0.3
Eccentricity of exterior load from footing [m] = 0.35
R.C designation : Fcu [N/sq.mm] = 40
reinf. Strength : Fy [N/sq.mm] = 460
density of soil [KN/cu.m] 18
Calculation:
reaction of ext.footing R1 143.16 [KN]
geo. reaction of ext.footing R1T 150.38 [KN]
Req. ext. footing 1.00 [sq.m] Dim. sq 1.00127
Use dimensions for ext.footing L= 1.2 [m] Area prov.d 1.44 144%
B= 1.2 [m] in strap direction
Use dimensions for int.footing L= 1.6 [m] Area prov.d 2.56 201%
B= 1.6 [m] in strap direction
check dim TRUE
Page 1 of 3
Designe of strap beam:
Breadth of strap beam [m] 0.3
depth of strap beam from shear d 155.49 [mm]
Use depth d 400 [mm] TRUE
total depth H 450 [mm]
fcu = 40 N/smm fy = 460 N/smm
Ult. column load 214.75 [KN] Safe bearing capacity 150 [KN/sq.m]
Self weight 20.16 [KN] Overburden height 0.00 m A prvd.
2
Overburden 0.00 [KN] Area of footing reqd. 1.08 m TRUE
2
Total load 234.91 [KN] Area of footing provided 1.44 m L reqd.
Net upward pressure ult. 163.13 [KN/sq.m] Footing thickness 400 [mm] 0.90
Short span Long span B/W
Width B= 1.20 m Length L= 1.20 m 1.00
Column width 500.00 mm Column breadth 200 mm
Max. cantilever proj. 0.70 m Max. cantilever proj. 0.50 m As min
Max. B.M. /m width 39.97 kNm Max. B.M. /m width 20 kNm 447
2 2 2 2
K = M/bd fcu 0.009 N/mm K = M/bd fcu 0.004 N/mmNo. of bars
Z 315.40 mm Z 327 mm 6
As required /m width 316.63 [mm] As required /m width 156 [sq.mm] 6
Diameter of bars 12 [mm] Diameter of bars 12 [mm]
Spacing of bars 200 [mm] Number of bars/side 200 [mm] As prvd. TRUE
As provided/m width 565 [sq.mm] As provided/m width 565 [sq.mm] 179%
363%
Punch shear 0.00 [KN] Dist. to critical section 350 [mm]
Punch shear stress 0.00 [N/sq.mm] Shear force 57 [KN]
Allow.shear stress 0.36 [N/sq.mm] Shear stress 0.17 [N/sq.mm] TRUE
Page 2 of 3
Designe of interior footing:
Net presure under int. footing 80.36 [KN/sq.m] TRUE
Ult. column load 272.754545 [KN] Safe bearing capacity 150 [KN/sq.m]
Self weight 54 [KN] Overburden height -0.20 m A prvd.
2
Overburden -18 [KN] Area of footing reqd. 1.42 m TRUE
2
Total load 309 [KN] Area of footing provided 2.56 m L reqd.
Net upward pressure ult. 121 [KN/sq.m] Footing thickness 600 [mm] 0.89
Short span Long span B/W
Width B= 1.60 m Length L= 1.60 m 1.00
Column width 500 mm Column breadth 200 mm
Max. cantilever proj. 0.55 m Max. cantilever proj. 0.70 m As min
Max. B.M. /m width 18 kNm Max. B.M. /m width 30 kNm 707
2 2 2 2
K = M/bd fcu 0.002 N/mm K = M/bd fcu 0.002 N/mmNo. of bars
Z 505 mm Z 517 mm 10
As required /m width 90 [mm] As required /m width 143 [sq.mm] 10
Diameter of bars 12 [mm] Diameter of bars 12 [mm]
Spacing of bars 150 [mm] Number of bars/side 150 [mm] As prvd. TRUE
As provided/m width 754 [sq.mm] As provided/m width 754 [sq.mm] 836%
528%
Punch shear 0 [KN] Dist. to critical section 350 [mm]
Punch shear stress 0.000 [N/sq.mm] Shear force 42 [KN]
Allow.shear stress 0.33 [N/sq.mm] Shear stress 0.08 [N/sq.mm] TRUE
Page 3 of 3