You are on page 1of 32

NODE NO:33

Design:
Pu= 689.5 kN
b= 230 mm 0.23 m
D= 450 mm 0.45 m
d= 400 mm 0.4 m
SBC of soil= 180 kN/m2
fck = 25 N/m2
fy = 415 N/m2
Mu = 4.1 kNm

1 Size of footing
Working load of column= 459.6667 kN
Self weight of footing(10%)= 45.96667 kN
The factored load=Wu= 505.6333 kN

Footing area= 2.6 m2

Short side of footing= 1.6 m


Long side of footing= 1.6 m

Adopt a square footing size as 1.6m by 1.6m

Factored soil pressure= 180 kN/m2 <(1.5*180)= 270 kN/m2

Hence the footing area is adequate since the soil pressure developed at the
base is less the factored bearing capacity of soil.

2 cantilever projects

cantilever projection from the short side face of the column= 0.57
cantilever projection from the Long side face of the column= 0.68

3 Depth of footing
a. From moment consideration we have
Mu=0.138 fck b d²
d= 34.5 mm

b. From shear stress consideration we have the critical section


for one way shear is located at a distance d from the face of the column
Vul=180(1510-d)-----------------------eq1
assuming τc = .36N/mm² for M20 grade concrete
Pt=.25
Vul=τc b d------------------------------eq2
comparing 1 & 2
d= 191.34 mm 200 mm
hence adopt effective depth = d= 200mm and overall depth = 250mm
D= 250 mm
4 Reinforcement in footing
a. Longer direction
Ast = [(0.5*fck*b*d)/(fy)*(1-√(1-(4.6*Mu/fck*b*d^2)))]
= 57.07763 mm²
198.1337 c/c
Provide 12 mm dia bars @175 mm c/c
b. Shorter direction
Ast = 0.12% of Cross section area
= 300 mm²
261.7667 c/c
Provide 10mm dia bars @ 250mm c/c
NODE NO:34
Design:
Pu= 1128.99 kN
b= 230 mm 0.23 m
D= 450 mm 0.45 m
d= 400 mm 0.4 m
SBC of soil= 180 kN/m2
fck = 25 N/m2
fy = 415 N/m2
Mu = 4.57 kNm

1 Size of footing
Working load of column= 752.66 kN
Self weight of footing(10%)= 75.266 kN
The factored load=Wu= 827.926 kN

Footing area= 4.2 m2

Short side of footing= 2.0 m


Long side of footing= 2.0 m

Adopt a square footing size as 2m by 2m

Factored soil pressure= 180 kN/m2 <(1.5*180)= 270 kN/m2

Hence the footing area is adequate since the soil pressure developed at the
base is less the factored bearing capacity of soil.

2 cantilever projects

cantilever projection from the short side face of the column= 0.80
cantilever projection from the Long side face of the column= 0.91

3 Depth of footing
a. From moment consideration we have
Mu=0.138 fck b d²
d= 36.4 mm

b. From shear stress consideration we have the critical section


for one way shear is located at a distance d from the face of the column
Vul=180(1510-d)-----------------------eq1
assuming τc = .36N/mm² for M20 grade concrete
Pt=.25
Vul=τc b d------------------------------eq2

comparing 1 & 2
d= 265.81 mm 300 mm
hence adopt effective depth = d= 300mm and overall depth = 350mm
D= 350 mm
4 Reinforcement in footing
a. Longer direction
Ast = [(0.5*fck*b*d)/(fy)*(1-√(1-(4.6*Mu/fck*b*d^2)))]
= 42.31191 mm²
267.277 c/c
Provide 12 mm dia bars @200 mm c/c
b. Shorter direction
Ast = 0.12% of Cross section area
= 420 mm²
186.9762 c/c
Provide 10mm dia bars @ 150mm c/c
NODE NO:35
Design:
Pu= 1009.5 kN
b= 230 mm 0.23 m
D= 450 mm 0.45 m
d= 400 mm 0.4 m
SBC of soil= 180 kN/m2
fck = 25 N/m2
fy = 415 N/m2
Mu = 4.65 kNm

1 Size of footing
Working load of column= 673 kN
Self weight of footing(10%)= 67.3 kN
The factored load=Wu= 740.3 kN

Footing area= 3.7 m2

Short side of footing= 1.9 m


Long side of footing= 1.9 m

Adopt a square footing size as 1.9m by 1.9m

Factored soil pressure= 180 kN/m2 <(1.5*180)= 270 kN/m2

Hence the footing area is adequate since the soil pressure developed at the
base is less the factored bearing capacity of soil.

2 cantilever projects

cantilever projection from the short side face of the column= 0.74
cantilever projection from the Long side face of the column= 0.85

3 Depth of footing
a. From moment consideration we have
Mu=0.138 fck b d²
d= 36.7 mm

b. From shear stress consideration we have the critical section


for one way shear is located at a distance d from the face of the column
Vul=180(1510-d)-----------------------eq1
assuming τc = .36N/mm² for M20 grade concrete
Pt=.25
Vul=τc b d------------------------------eq2
comparing 1 & 2
d= 247.27 mm 300 mm
hence adopt effective depth = d= 300mm and overall depth = 350mm
D= 350 mm
4 Reinforcement in footing
a. Longer direction
Ast = [(0.5*fck*b*d)/(fy)*(1-√(1-(4.6*Mu/fck*b*d^2)))]
= 43.05438 mm²
262.6678 c/c
Provide 12 mm dia bars @200 mm c/c
b. Shorter direction
Ast = 0.12% of Cross section area
= 420 mm²
186.9762 c/c
Provide 10mm dia bars @ 150mm c/c
NODE NO:36
Design:
Pu= 584.7 kN
b= 230 mm 0.23 m
D= 450 mm 0.45 m
d= 400 mm 0.4 m
SBC of soil= 180 kN/m2
fck = 25 N/m2
fy = 415 N/m2
Mu = 4.23 kNm

1 Size of footing
Working load of column= 389.8 kN
Self weight of footing(10%)= 38.98 kN
The factored load=Wu= 428.78 kN

Footing area= 2.2 m2

Short side of footing= 1.5 m


Long side of footing= 1.5 m

Adopt a square footing size as 1.5m by 1.5m

Factored soil pressure= 180 kN/m2 <(1.5*180)= 270 kN/m2

Hence the footing area is adequate since the soil pressure developed at the
base is less the factored bearing capacity of soil.

2 cantilever projects

cantilever projection from the short side face of the column= 0.51
cantilever projection from the Long side face of the column= 0.62

3 Depth of footing
a. From moment consideration we have
Mu=0.138 fck b d²
d= 35.0 mm

b. From shear stress consideration we have the critical section


for one way shear is located at a distance d from the face of the column
Vul=180(1510-d)-----------------------eq1
assuming τc = .36N/mm² for M20 grade concrete
Pt=.25
Vul=τc b d------------------------------eq2
comparing 1 & 2
d= 170.26 mm 200 mm
hence adopt effective depth = d= 200mm and overall depth = 250mm
D= 250 mm
4 Reinforcement in footing
a. Longer direction
Ast = [(0.5*fck*b*d)/(fy)*(1-√(1-(4.6*Mu/fck*b*d^2)))]
= 58.89634 mm²
192.0153 c/c
Provide 12 mm dia bars @175 mm c/c
b. Shorter direction
Ast = 0.12% of Cross section area
= 300 mm²
261.7667 c/c
Provide 10mm dia bars @ 250mm c/c
NODE NO:37
Design:
Pu= 1060.6 kN
b= 230 mm 0.23 m
D= 450 mm 0.45 m
d= 400 mm 0.4 m
SBC of soil= 180 kN/m2
fck = 25 N/m2
fy = 415 N/m2
Mu = 3.87 kNm

1 Size of footing
Working load of column= 707.0667 kN
Self weight of footing(10%)= 70.70667 kN
The factored load=Wu= 777.7733 kN

Footing area= 3.9 m2

Short side of footing= 2.0 m


Long side of footing= 2.0 m

Adopt a square footing size as 2m by 2m

Factored soil pressure= 180 kN/m2 <(1.5*180)= 270 kN/m2

Hence the footing area is adequate since the soil pressure developed at the
base is less the factored bearing capacity of soil.

2 cantilever projects

cantilever projection from the short side face of the column= 0.77
cantilever projection from the Long side face of the column= 0.88

3 Depth of footing
a. From moment consideration we have
Mu=0.138 fck b d²
d= 33.5 mm

b. From shear stress consideration we have the critical section


for one way shear is located at a distance d from the face of the column
Vul=180(1510-d)-----------------------eq1
assuming τc = .36N/mm² for M20 grade concrete
Pt=.25
Vul=τc b d------------------------------eq2
comparing 1 & 2
d= 255.33 mm 300 mm
hence adopt effective depth = d= 300mm and overall depth = 350mm
D= 350 mm
4 Reinforcement in footing
a. Longer direction
Ast = [(0.5*fck*b*d)/(fy)*(1-√(1-(4.6*Mu/fck*b*d^2)))]
= 35.81798 mm²
315.7353 c/c
Provide 12 mm dia bars @300 mm c/c
b. Shorter direction
Ast = 0.12% of Cross section area
= 420 mm²
186.9762 c/c
Provide 10mm dia bars @ 150mm c/c
NODE NO:38
Design:
Pu= 1691.46 kN
b= 230 mm 0.23 m
D= 450 mm 0.45 m
d= 400 mm 0.4 m
SBC of soil= 180 kN/m2
fck = 25 N/m2
fy = 415 N/m2
Mu = 1.866 kNm

1 Size of footing
Working load of column= 1127.64 kN
Self weight of footing(10%)= 112.764 kN
The factored load=Wu= 1240.404 kN

Footing area= 6.3 m2

Short side of footing= 2.5 m


Long side of footing= 2.5 m

Adopt a square footing size as 2.5m by 2.5m

Factored soil pressure= 180 kN/m2 <(1.5*180)= 270 kN/m2

Hence the footing area is adequate since the soil pressure developed at the
base is less the factored bearing capacity of soil.

2 cantilever projects

cantilever projection from the short side face of the column= 1.03
cantilever projection from the Long side face of the column= 1.14

3 Depth of footing
a. From moment consideration we have
Mu=0.138 fck b d²
d= 23.3 mm

b. From shear stress consideration we have the critical section


for one way shear is located at a distance d from the face of the column
Vul=180(1510-d)-----------------------eq1
assuming τc = .36N/mm² for M20 grade concrete
Pt=.25
Vul=τc b d------------------------------eq2
comparing 1 & 2
d= 342.16 mm 350 mm
hence adopt effective depth = d= 350mm and overall depth = 400mm
D= 400 mm
4 Reinforcement in footing
a. Longer direction
Ast = [(0.5*fck*b*d)/(fy)*(1-√(1-(4.6*Mu/fck*b*d^2)))]
= 14.7842 mm²
764.938 c/c
Provide 12 mm dia bars @300 mm c/c
b. Shorter direction
Ast = 0.12% of Cross section area
= 480 mm²
163.6042 c/c
Provide 10mm dia bars @ 150mm c/c
NODE NO:39
Design:
Pu= 1506.69 kN
b= 230 mm 0.23 m
D= 450 mm 0.45 m
d= 400 mm 0.4 m
SBC of soil= 180 kN/m2
fck = 25 N/m2
fy = 415 N/m2
Mu = 1.962 kNm

1 Size of footing
Working load of column= 1004.46 kN
Self weight of footing(10%)= 100.446 kN
The factored load=Wu= 1104.906 kN

Footing area= 5.6 m2

Short side of footing= 2.4 m


Long side of footing= 2.4 m

Adopt a square footing size as 2.4m by 2.4m


.
Factored soil pressure= 180 kN/m2 <(1.5*180)= 270 kN/m2

Hence the footing area is adequate since the soil pressure developed at the
base is less the factored bearing capacity of soil.

2 cantilever projects

cantilever projection from the short side face of the column= 0.96
cantilever projection from the Long side face of the column= 1.07

3 Depth of footing
a. From moment consideration we have
Mu=0.138 fck b d²
d= 23.8 mm

b. From shear stress consideration we have the critical section


for one way shear is located at a distance d from the face of the column
Vul=180(1510-d)-----------------------eq1
assuming τc = .36N/mm² for M20 grade concrete
Pt=.25
Vul=τc b d------------------------------eq2
comparing 1 & 2
d= 318.71 mm 350 mm
hence adopt effective depth = d= 350mm and overall depth = 400mm
D= 400 mm
4 Reinforcement in footing
a. Longer direction
Ast = [(0.5*fck*b*d)/(fy)*(1-√(1-(4.6*Mu/fck*b*d^2)))]
= 15.54537 mm²
727.4836 c/c
Provide 12 mm dia bars @300 mm c/c
b. Shorter direction
Ast = 0.12% of Cross section area
= 480 mm²
163.6042 c/c
Provide 10mm dia bars @ 150mm c/c
NODE NO:40
Design:
Pu= 933.9213 kN
b= 230 mm 0.23 m
D= 450 mm 0.45 m
d= 400 mm 0.4 m
SBC of soil= 180 kN/m2
fck = 25 N/m2
fy = 415 N/m2
Mu = 1.07 kNm

1 Size of footing
Working load of column= 622.6142 kN
Self weight of footing(10%)= 62.26142 kN
The factored load=Wu= 684.8756 kN

Footing area= 3.5 m2

Short side of footing= 1.9 m


Long side of footing= 1.9 m

Adopt a square footing size as 1.9m by 1.9m

Factored soil pressure= 180 kN/m2 <(1.5*180)= 270 kN/m2

Hence the footing area is adequate since the soil pressure developed at the
base is less the factored bearing capacity of soil.

2 cantilever projects

cantilever projection from the short side face of the column= 0.70
cantilever projection from the Long side face of the column= 0.81

3 Depth of footing
a. From moment consideration we have
Mu=0.138 fck b d²
d= 17.6 mm

b. From shear stress consideration we have the critical section


for one way shear is located at a distance d from the face of the column
Vul=180(1510-d)-----------------------eq1
assuming τc = .36N/mm² for M20 grade concrete
Pt=.25
Vul=τc b d------------------------------eq2
comparing 1 & 2
d= 234.97 mm 300 mm
hence adopt effective depth = d= 300mm and overall depth = 350mm
D= 350 mm
4 Reinforcement in footing
a. Longer direction
Ast = [(0.5*fck*b*d)/(fy)*(1-√(1-(4.6*Mu/fck*b*d^2)))]
= 9.888945 mm²
1143.6 c/c
Provide 12 mm dia bars @300 mm c/c
b. Shorter direction
Ast = 0.12% of Cross section area
= 420 mm²
186.9762 c/c
Provide 10mm dia bars @ 150mm c/c
NODE NO:41
Design:
Pu= 1087.4 kN
b= 230 mm 0.23 m
D= 450 mm 0.45 m
d= 400 mm 0.4 m
SBC of soil= 180 kN/m2
fck = 25 N/m2
fy = 415 N/m2
Mu = 3.75 kNm

1 Size of footing
Working load of column= 724.9333 kN
Self weight of footing(10%)= 72.49333 kN
The factored load=Wu= 797.4267 kN

Footing area= 4.0 m2

Short side of footing= 2.0 m


Long side of footing= 2.0 m

Adopt a square footing size as 2m by 2m

Factored soil pressure= 180 kN/m2 <(1.5*180)= 270 kN/m2

Hence the footing area is adequate since the soil pressure developed at the
base is less the factored bearing capacity of soil.

2 cantilever projects

cantilever projection from the short side face of the column= 0.78
cantilever projection from the Long side face of the column= 0.89

3 Depth of footing
a. From moment consideration we have
Mu=0.138 fck b d²
d= 33.0 mm

b. From shear stress consideration we have the critical section


for one way shear is located at a distance d from the face of the column
Vul=180(1510-d)-----------------------eq1
assuming τc = .36N/mm² for M20 grade concrete
Pt=.25
Vul=τc b d------------------------------eq2
comparing 1 & 2
d= 259.47 mm 300 mm
hence adopt effective depth = d= 300mm and overall depth = 350mm
D= 350 mm
4 Reinforcement in footing
a. Longer direction
Ast = [(0.5*fck*b*d)/(fy)*(1-√(1-(4.6*Mu/fck*b*d^2)))]
= 34.7052 mm²
325.8589 c/c
Provide 12 mm dia bars @300 mm c/c
b. Shorter direction
Ast = 0.12% of Cross section area
= 420 mm²
186.9762 c/c
Provide 10mm dia bars @ 150mm c/c
NODE NO:42
Design:
Pu= 1709 kN
b= 230 mm 0.23 m
D= 450 mm 0.45 m
d= 400 mm 0.4 m
SBC of soil= 180 kN/m2
fck = 25 N/m2
fy = 415 N/m2
Mu = 1.75 kNm

1 Size of footing
Working load of column= 1139.333 kN
Self weight of footing(10%)= 113.9333 kN
The factored load=Wu= 1253.267 kN

Footing area= 6.3 m2

Short side of footing= 2.5 m


Long side of footing= 2.5 m

Adopt a square footing size as 2.5m by 2.5m

Factored soil pressure= 180 kN/m2 <(1.5*180)= 270 kN/m2

Hence the footing area is adequate since the soil pressure developed at the
base is less the factored bearing capacity of soil.

2 cantilever projects

cantilever projection from the short side face of the column= 1.03
cantilever projection from the Long side face of the column= 1.14

3 Depth of footing
a. From moment consideration we have
Mu=0.138 fck b d²
d= 22.5 mm

b. From shear stress consideration we have the critical section


for one way shear is located at a distance d from the face of the column
Vul=180(1510-d)-----------------------eq1
assuming τc = .36N/mm² for M20 grade concrete
Pt=.25
Vul=τc b d------------------------------eq2
comparing 1 & 2
d= 344.31 mm 350 mm
hence adopt effective depth = d= 350mm and overall depth = 400mm
D= 400 mm
4 Reinforcement in footing
a. Longer direction
Ast = [(0.5*fck*b*d)/(fy)*(1-√(1-(4.6*Mu/fck*b*d^2)))]
= 13.86454 mm²
815.6781 c/c
Provide 12 mm dia bars @300 mm c/c
b. Shorter direction
Ast = 0.12% of Cross section area
= 480 mm²
163.6042 c/c
Provide 10mm dia bars @ 150mm c/c
NODE NO:43
Design:
Pu= 1523.6 kN
b= 230 mm 0.23 m
D= 450 mm 0.45 m
d= 400 mm 0.4 m
SBC of soil= 180 kN/m2
fck = 25 N/m2
fy = 415 N/m2
Mu = 2.08 kNm

1 Size of footing
Working load of column= 1015.733 kN
Self weight of footing(10%)= 101.5733 kN
The factored load=Wu= 1117.307 kN

Footing area= 5.6 m2

Short side of footing= 2.4 m


Long side of footing= 2.4 m

Adopt a square footing size as 2.4m by 2.4m

Factored soil pressure= 180 kN/m2 <(1.5*180)= 270 kN/m2

Hence the footing area is adequate since the soil pressure developed at the
base is less the factored bearing capacity of soil.

2 cantilever projects

cantilever projection from the short side face of the column= 0.96
cantilever projection from the Long side face of the column= 1.07

3 Depth of footing
a. From moment consideration we have
Mu=0.138 fck b d²
d= 24.6 mm

b. From shear stress consideration we have the critical section


for one way shear is located at a distance d from the face of the column
Vul=180(1510-d)-----------------------eq1
assuming τc = .36N/mm² for M20 grade concrete
Pt=.25
Vul=τc b d------------------------------eq2
comparing 1 & 2
d= 320.92 mm 350 mm
hence adopt effective depth = d= 350mm and overall depth = 400mm
D= 400 mm
4 Reinforcement in footing
a. Longer direction
Ast = [(0.5*fck*b*d)/(fy)*(1-√(1-(4.6*Mu/fck*b*d^2)))]
= 16.48104 mm²
686.1824 c/c
Provide 12 mm dia bars @300 mm c/c
b. Shorter direction
Ast = 0.12% of Cross section area
= 480 mm²
163.6042 c/c
Provide 10mm dia bars @ 150mm c/c
NODE NO:44
Design:
Pu= 959.27 kN
b= 230 mm 0.23 m
D= 450 mm 0.45 m
d= 400 mm 0.4 m
SBC of soil= 180 kN/m2
fck = 25 N/m2
fy = 415 N/m2
Mu = 1.48 kNm

1 Size of footing
Working load of column= 639.5133 kN
Self weight of footing(10%)= 63.95133 kN
The factored load=Wu= 703.4647 kN

Footing area= 3.6 m2

Short side of footing= 1.9 m


Long side of footing= 1.9 m

Adopt a square footing size as 1.9m by 1.9m

Factored soil pressure= 180 kN/m2 <(1.5*180)= 270 kN/m2

Hence the footing area is adequate since the soil pressure developed at the
base is less the factored bearing capacity of soil.

2 cantilever projects

cantilever projection from the short side face of the column= 0.72
cantilever projection from the Long side face of the column= 0.83

3 Depth of footing
a. From moment consideration we have
Mu=0.138 fck b d²
d= 20.7 mm

b. From shear stress consideration we have the critical section


for one way shear is located at a distance d from the face of the column
Vul=180(1510-d)-----------------------eq1
assuming τc = .36N/mm² for M20 grade concrete
Pt=.25
Vul=τc b d------------------------------eq2
comparing 1 & 2
d= 239.15 mm 300 mm
hence adopt effective depth = d= 300mm and overall depth = 350mm
D= 350 mm
4 Reinforcement in footing
a. Longer direction
Ast = [(0.5*fck*b*d)/(fy)*(1-√(1-(4.6*Mu/fck*b*d^2)))]
= 13.68104 mm²
826.6185 c/c
Provide 12 mm dia bars @300 mm c/c
b. Shorter direction
Ast = 0.12% of Cross section area
= 420 mm²
186.9762 c/c
Provide 10mm dia bars @ 150mm c/c
NODE NO:45
Design:
Pu= 703.8 kN
b= 230 mm 0.23 m
D= 450 mm 0.45 m
d= 400 mm 0.4 m
SBC of soil= 180 kN/m2
fck = 25 N/m2
fy = 415 N/m2
Mu = 5.6 kNm

1 Size of footing
Working load of column= 469.2 kN
Self weight of footing(10%)= 46.92 kN
The factored load=Wu= 516.12 kN

Footing area= 2.6 m2

Short side of footing= 1.6 m


Long side of footing= 1.6 m

Adopt a square footing size as 1.6m by 1.6m

Factored soil pressure= 180 kN/m2 <(1.5*180)= 270 kN/m2

Hence the footing area is adequate since the soil pressure developed at the
base is less the factored bearing capacity of soil.

2 cantilever projects

cantilever projection from the short side face of the column= 0.58
cantilever projection from the Long side face of the column= 0.69

3 Depth of footing
a. From moment consideration we have
Mu=0.138 fck b d²
d= 40.3 mm

b. From shear stress consideration we have the critical section


for one way shear is located at a distance d from the face of the column
Vul=180(1510-d)-----------------------eq1
assuming τc = .36N/mm² for M20 grade concrete
Pt=.25
Vul=τc b d------------------------------eq2
comparing 1 & 2
d= 194.09 mm 200 mm
hence adopt effective depth = d= 200mm and overall depth = 350mm
D= 250 mm
4 Reinforcement in footing
a. Longer direction
Ast = [(0.5*fck*b*d)/(fy)*(1-√(1-(4.6*Mu/fck*b*d^2)))]
= 78.09658 mm²
144.8079 c/c
Provide 12 mm dia bars @125 mm c/c
b. Shorter direction
Ast = 0.12% of Cross section area
= 300 mm²
261.7667 c/c
Provide 10mm dia bars @ 250mm c/c
NODE NO:46
Design:
Pu= 1131.31 kN
b= 230 mm 0.23 m
D= 450 mm 0.45 m
d= 400 mm 0.4 m
SBC of soil= 180 kN/m2
fck = 25 N/m2
fy = 415 N/m2
Mu = 5.475 kNm

1 Size of footing
Working load of column= 754.2067 kN
Self weight of footing(10%)= 75.42067 kN
The factored load=Wu= 829.6273 kN

Footing area= 4.2 m2

Short side of footing= 2.0 m


Long side of footing= 2.0 m

Adopt a square footing size as 2m by 2m

Factored soil pressure= 180 kN/m2 <(1.5*180)= 270 kN/m2

Hence the footing area is adequate since the soil pressure developed at the
base is less the factored bearing capacity of soil.

2 cantilever projects

cantilever projection from the short side face of the column= 0.80
cantilever projection from the Long side face of the column= 0.91

3 Depth of footing
a. From moment consideration we have
Mu=0.138 fck b d²
d= 39.8 mm

b. From shear stress consideration we have the critical section


for one way shear is located at a distance d from the face of the column
Vul=180(1510-d)-----------------------eq1
assuming τc = .36N/mm² for M20 grade concrete
Pt=.25
Vul=τc b d------------------------------eq2
comparing 1 & 2
d= 266.16 mm 300 mm
hence adopt effective depth = d= 300mm and overall depth = 350mm
D= 350 mm
4 Reinforcement in footing
a. Longer direction
Ast = [(0.5*fck*b*d)/(fy)*(1-√(1-(4.6*Mu/fck*b*d^2)))]
= 50.7146 mm²
222.993 c/c
Provide 12 mm dia bars @200 mm c/c
b. Shorter direction
Ast = 0.12% of Cross section area
= 420 mm²
186.9762 c/c
Provide 10mm dia bars @ 150mm c/c
NODE NO:47
Design:
Pu= 1011.25 kN
b= 230 mm 0.23 m
D= 450 mm 0.45 m
d= 400 mm 0.4 m
SBC of soil= 180 kN/m2
fck = 25 N/m2
fy = 415 N/m2
Mu = 5.45 kNm

1 Size of footing
Working load of column= 674.1667 kN
Self weight of footing(10%)= 67.41667 kN
The factored load=Wu= 741.5833 kN

Footing area= 3.7 m2

Short side of footing= 1.9 m


Long side of footing= 1.9 m

Adopt a square footing size as 1.9m by 1.9m

Factored soil pressure= 180.00 kN/m2 <(1.5*180)= 270 kN/m2

Hence the footing area is adequate since the soil pressure developed at the
base is less the factored bearing capacity of soil.

2 cantilever projects

cantilever projection from the short side face of the column= 0.74
cantilever projection from the Long side face of the column= 0.85

3 Depth of footing
a. From moment consideration we have
Mu=0.138 fck b d²
d= 39.7 mm

b. From shear stress consideration we have the critical section


for one way shear is located at a distance d from the face of the column
Vul=180(1510-d)-----------------------eq1
assuming τc = .36N/mm² for M20 grade concrete
Pt=.25
Vul=τc b d------------------------------eq2
comparing 1 & 2
d= 247.55 mm 300 mm
hence adopt effective depth = d= 300mm and overall depth = 350mm
D= 350 mm
4 Reinforcement in footing
a. Longer direction
Ast = [(0.5*fck*b*d)/(fy)*(1-√(1-(4.6*Mu/fck*b*d^2)))]
= 50.48238 mm²
224.0188 c/c
Provide 12 mm dia bars @200 mm c/c
b. Shorter direction
Ast = 0.12% of Cross section area
= 420 mm²
186.9762 c/c
Provide 10mm dia bars @ 150mm c/c
NODE NO:48
Design:
Pu= 598.7 kN
b= 230 mm 0.23 m
D= 450 mm 0.45 m
d= 400 mm 0.4 m
SBC of soil= 180 kN/m2
fck = 25 N/m2
fy = 415 N/m2
Mu = 5.572 kNm

1 Size of footing
Working load of column= 399.1333 kN
Self weight of footing(10%)= 39.91333 kN
The factored load=Wu= 439.0467 kN

Footing area= 2.2 m2

Short side of footing= 1.5 m


Long side of footing= 1.5 m

Adopt a square footing size as 1.5m by 1.5m

Factored soil pressure= 180 kN/m2 <(1.5*180)= 270 kN/m2

Hence the footing area is adequate since the soil pressure developed at the
base is less the factored bearing capacity of soil.

2 cantilever projects

cantilever projection from the short side face of the column= 0.52
cantilever projection from the Long side face of the column= 0.63
3 Depth of footing
a. From moment consideration we have
Mu=0.138 fck b d²
d= 40.2 mm

b. From shear stress consideration we have the critical section


for one way shear is located at a distance d from the face of the column
Vul=180(1510-d)-----------------------eq1
assuming τc = .36N/mm² for M20 grade concrete
Pt=.25
Vul=τc b d------------------------------eq2

comparing 1 & 2
d= 173.18 mm 200 mm
hence adopt effective depth = d= 200mm and overall depth = 250mm
D= 250 mm
4 Reinforcement in footing
a. Longer direction
Ast = [(0.5*fck*b*d)/(fy)*(1-√(1-(4.6*Mu/fck*b*d^2)))]
= 77.70355 mm²
145.5403 c/c
Provide 12 mm dia bars @125 mm c/c
b. Shorter direction
Ast = 0.12% of Cross section area
= 300 mm²
261.7667 c/c
Provide 10mm dia bars @ 250mm c/c

You might also like