Professional Documents
Culture Documents
TABLE CONTENT
No/Part Description Page
3 Attachments :
Personil Certificate i
Equipment certificate ii
PT.RIRE SANJAYA SAKTI
Rope Access & NDT Services
MAGNETIC PARTICLE EXAMINATION REPORT
REPORT NUMBER RSS/NDT-MT/PGNSAKASIDAYU/11-20/001 RSS/MT/-ASME/010
Procedure No.
CLIENT PT.VALARBI/ PT.PGN SAKA
PROJECT TITLE PGN SAKA SIDAYU PROJECT ASME VIII DIV.I
Applicable Code
SITE WORK PT. GUNA NUSA UTAMA FABRICATION
DATE OF TEST 6-Nov-20 PRODUCT / ITEM as in Item Description
EQUIPMENT Yoke Prods Coil SERIAL / PART NUMBER N/A
SERIAL NUMBER 18056 MATERIAL Carbon Steel
CURRENT AC DC PERMANENT GRADE N/A
METHOD Continuous Residual HEAT TREATMENT N/A
TYPE Wet Dry Fluoresent Colour Contrast SURFACE CONDITION As Machined As Welded As Ground
STAGE OF TESTING Initial Test After load Test SURFACE TEMPERATURE Ambient Others : ……………………
Part / Qty
Item Description RESULT Observation COMMENTS
/Joint Number
hook Crane WHP "D" 5 Ton ACCEPT REJECT Crack No significant indication/discontinuity
Porrosity
Cavity
Others
No Discontinuity
hook Crane WHP "D" 1 Ton ACCEPT REJECT Crack No significant indication/discontinuity
Porrosity
Cavity
Others
No Discontinuity
Welding Joint (Root Boom area) J.01 ACCEPT REJECT Crack No significant indication/discontinuity
Porrosity
Cavity
Others
No Discontinuity
Welding Joint (Root Boom Area) J.02 ACCEPT REJECT Crack No significant indication/discontinuity
Porrosity
Cavity
Others
No Discontinuity
STAGE OF TESTING Initial Test After load Test SURFACE TEMPERATURE Ambient Others : ……………………
Part / Qty
Item Description RESULT Observation COMMENTS
/Joint Number
hook Crane WHP "C" 5 Ton ACCEPT REJECT Crack No significant indication/discontinuity
Porrosity
Cavity
Others
No Discontinuity
hook Crane WHP "C" 1 Ton ACCEPT REJECT Crack No significant indication/discontinuity
Porrosity
Cavity
Others
No Discontinuity
Welding Joint (Root Boom Area) J.01 ACCEPT REJECT Crack No significant indication/discontinuity
Porrosity
Cavity
Others
No Discontinuity
Welding Joint (Root Boom Area) J.02 ACCEPT REJECT Crack No significant indication/discontinuity
Porrosity
Cavity
Others
No Discontinuity
STAGE OF TESTING Initial Test After load Test SURFACE TEMPERATURE Ambient Others : ……………………
Part / Qty
Item Description RESULT Observation COMMENTS
/Joint Number
hook Crane WHP "C" 5 Ton ACCEPT REJECT Crack No significant indication/discontinuity
Porrosity
Cavity
Others
No Discontinuity
hook Crane WHP "C" 1 Ton ACCEPT REJECT Crack No significant indication/discontinuity
Porrosity
Cavity
Others
No Discontinuity
Welding Joint (Root Boom Area) J.01 ACCEPT REJECT Crack No significant indication/discontinuity
Porrosity
Cavity
Others
No Discontinuity
Welding Joint (Root Boom Area) J.02 ACCEPT REJECT Crack No significant indication/discontinuity
Porrosity
Cavity
Others
No Discontinuity
STAGE OF TESTING Initial Test After load Test SURFACE TEMPERATURE Ambient Others : ……………………
Part / Qty
Item Description RESULT Observation COMMENTS
/Joint Number
hook Crane WHP "D" 5 Ton ACCEPT REJECT Crack No significant indication/discontinuity
Porrosity
Cavity
Others
No Discontinuity
hook Crane WHP "D" 1 Ton ACCEPT REJECT Crack No significant indication/discontinuity
Porrosity
Cavity
Others
No Discontinuity
Welding Joint (Root Boom Area) J.01 ACCEPT REJECT Crack No significant indication/discontinuity
Porrosity
Cavity
Others
No Discontinuity
Welding Joint (Root Boom Area) J.02 ACCEPT REJECT Crack No significant indication/discontinuity
Porrosity
Cavity
Others
No Discontinuity
RAJA ROMANUR
Company : PT. Rire Sanjaya Sakti
has satisfactorily completed the training and qualification in accordance with the specified
statements below :
Training duration March 09 up to 14, 2020 (24 hours)
In accordance with SNT - TC - 1A, 2016 edition
NOT Method Liquid Penetrant Testing
Eligible to be certified Level II (two)
MSS's Written Practice no. WP - 01, revision no. 07
EXAMlNAnON RESULTS
Type of Examinatjon Grade or Score Composite Grade (% ) Passing Grade (% )
A General 82.50 (A+B+C)I3= - Individual ~ 70
B Specific 85.00 8250 - Composite ~ 80
c Practical 80.00
Reference Code I Standards : ASNT CP-105, ASME Sect. V, Sect L Sect. VIII Div.l and ASTM E 165
Note : None
Office : Westem Regency G no. 3, Jl. Raya Sememi Benowo, Surabaya, East Java, Indonesia
Phone : +62 31 5743 1027, Fax : +62 31 5743 1028
e-mail : multispec@gmailcom ; website : www.mspec.org
4AI1rl~
'rmss~'
"-= .. -:.~1
' '·-~~~'I/
MULTI SPEC SINERGINDO (MSS)
( OUTSIDE TRAINING SERVICE )
CERTIFICATE OF QUAUFlCATION
Cert No.: 127 I MT I N I 20
RAJA ROMANUR
Company : PT. Rire Sanjaya Sakti
has satisfactorily completed the training and qualification in accordance with the specified
statements below :
Training duration March 15 up to 22, 2020 (32 hours)
In accordance with SNT - TC - lA, 2016 edition
NDT Method Magnetic Particle Testjng
Eligible to be certified Level II (two)
MSS's Written Practice no. WP - 01, revision no. 07
EXAMINATION RESULTS
Type of Examination Grade or Score Composjte Grade ( % ) Passing Grade ( % )
A General 87.50 (A+B+C)/3= - Individual ~ 70
B Specific 87.50 85.00 - Composite ~ 80
c Practical 80.00
Reference Code I Standards : ASNT CP-105, ASME Sect V, Sect. I, Sect. VIII Div.1 and ASTM E 709
Note : None
Date of Certification Apri I 22, 2020
Date of Expire April 21, 2025
-
(/?-,.:-.- -
Adi Padmrilt-,A;:~:-~
Director ASNT NDT Level ill
ID No. 126596 ( RT, UT, MT, PT)
Office: Western Regency G no. 3, Jl. Raya Sememl Benowo, Surabaya, East Java, Indonesia
Phone : +62 31 5743 1027, Fax : +62 315743 1028
e-mail : multispec@gmail.com ; website : www.mspec.org
PT. RIRE SANJAYA SAKTI