Professional Documents
Culture Documents
DESIGN OF TWO-WAY SLAB Page19
DESIGN OF TWO-WAY SLAB Page19
JOB INFORMATION
PROJECT ENGR K.L.L.A JOB NO 3
SUBJECT Design of Slab, S17 DATE 10/10/2020 SHT NO 17
MOMENT COEFFICIENTS
-CaDL = 0.060 Negative moment coefficient along the shorter dimension due to dead load
-CaLL = 0.060 Negative moment coefficient along the shorter dimension due to live load
-CbDL = 0.040 Negative moment coefficient along the longer dimension due to dead load
-CbLL = 0.040 Negative moment coefficient along the longer dimension due to live load
+CaDL = 0.033 Positive moment coefficient along the shorter dimension due to dead load
+CaLL = 0.039 Positive moment coefficient along the shorter dimension due to live load
+CbDL = 0.022 Positive moment coefficient along the longer dimension due to dead load
+CbLL = 0.026 Positive moment coefficient along the longer dimension due to live load
LOCATION EQUATIONS MOMENT MTOTAL rreqd Ductility rused Spacing suse Rebar spacing, mm
-CaDLWuDLLa2 9.34
Negative Moment, Ma 15.34 0.0081 ok 0.0081 189 189 12 mm diameter @ 150 mm
-CaLLWuLLLa2 5.99
-C W L 2 7.71
Negative Moment, Mb bDL uDL b2 12.66 0.0066 ok 0.0066 232 232 12 mm diameter @ 200 mm
-CbLLWuLLLb 4.95
+CaDLWuDLLa2 5.14
Positive Moment, Ma 9.03 0.0046 ok 0.0046 331 300 12 mm diameter @ 300 mm
+CaLLWuLLLa2 3.90
+CbDLWuDLLb2 4.24
Positive Moment, Mb 7.46 0.0038 ok 0.0038 404 300 12 mm diameter @ 300 mm
+CbLLWuLLLb2 3.22
SLAB DIMENSIONS
L SLAB REACTIONS
300 mm - 12 mm diameter WaDL = 0.5CaDLWDLLa
= 7.635 kN/m
200 mm - 12 mm diameter WaLL = 0.5CaLLWLLLa
= 3.672 kN/m