You are on page 1of 1

PRODUCTION AND TEST PACKER RETRIEVABLE

Operation: The Model ―BFH‖ Hydrostatic Packer is MODEL “BFHL” HYDROSTATIC SINGLE STRING
actuated by pressuring the Tubing, and this is generally PACKER
done in one of three ways: Product No.: BI 781-20

1. Dropping a ball to seat in a Hydro-Trip Pressure The Model ―BFHL‖ Hydrostatic Packer is a large bore
Sub or shear out Ball Seat Sub (Prod. No. BI version of the ―BFH‖ Packer. Features, advantages, and
799-27 or BI 469-21) located below the Packer. operational procedures are basically the same as those
2. Use of a Differential Displacing Valve provided described for the ―BFH‖.
operations will not require pressuring the tubing
before the displacing valve is to be opened. The Body Lock Ring mechanically locks in the set so
3. Landing a BFC Blanking Plug in a BFC Seating that a drop in hydrostatic pressure can have no effect
Nipple or Sliding Sleeve below the Packer. In on the Packer. After the Packer is set, the tubing is
most cases, the Plug can be run, the Packer opened by pressuring to force the tripping ball through
set, and the Plug retrieved all in one trip. the Pressure Sub or Displacing Valve or by retrieving
Where more than one Model ―BFH‖ Packer is to the BFC Plug.
be run, only one of these plugging devices
needs to be used below the lower most Packer. To Set Packer Where Hydrostatic Pressure is Less
This arrangement will result in simultaneous Than 1,500 PSI
setting of all the ―BFH‖ Packers when the tubing
is pressured. If simultaneous setting is not The Packer is dressed with additional shear screws to
desirable, shear values can be altered so the increase the actuating pressure to 2,000 psi; and the
Packers will set in sequence, the bottom first Hydro-Trip Pressure Sub or Shear-out Ball Seat Sub is
and the top last. dressed to require 3,500 psi differential to blow the ball
through after the packer is set.
To Set Packer Where Hydrostatic Pressure Is
Greater Than 1,500 PSI Using a Differential Displacing Valve

Run the Packer to setting depth, flange up the well and This valve offers distinct advantages where it is
displace the tubing. Using one of the methods desirable to displace the tubing after the well is flanged
mentioned above, Plug the Tubing and increase Tubing up and the tubing sealed off in a Packer below the
pressure to approximately 1,000 psi over annulus ―BFH‖. The valve is opened and the tubing displaced,
pressure at the Packer. The shear screws will shear, then one ball is dropped to set the Packer and close the
exposing the setting mechanism to the hydrostatic valve.
pressure in the well. This pressure completely sets and
packs-off the Packer. To Release the Packer

The standard Model ―BFH‖ Packer is equipped with a


SHEAR RING AVAILABILITY GUIDE
30,000 lbs. Shear Ring for a straight up-strain release.
Other values of Shear Rings available are shown
Shear Rating
Lbs. x1,000
in the table below.
Packer
Size 20 30 40 50
An alternate rotational-release is available on special
43 x x x x order, which permits the Packer to be released by
45 x x x x taking an up-strain and rotating to the right. The
47 x x x x rotational release has 50,000 lbs. 40,000 lbs. on Size 43
49 x x x x straight up-strain shear-out safety release.
51 x x x x
As an option, to make provision for adjustment of the
shear value, Shear Screws can be provided instead of
shear ring.