Título de documento: Grupo funcional: Tipo de información: Fecha:
Fault code list Información de servicio 01/17/2021 Perfil: PF6110 Volvo
Fault code list
Mostrando el perfil seleccionado
Válido para números de serie
Modelo: Lugar de producción Inicio de número de fabricación Parada de número de fabricación PF6110 Volvo
Fault code list, propulsion controller
Fault code Description Recoverable Associated FM and remarks
1–1–1 System voltage — low Yes None stored, just displayed 1–1–2 System voltage — high Yes 1–1–3 Sensor voltage 1 — low No Set all FMs except FM-G1 1–1–4 Sensor voltage 1 — high No Set all FMs except FM-G1 1–1–5 Sensor voltage 2 — low No Information only 1–2–1 Sensor voltage 2 — high No Information only 1–2–2 Machine type input — out of No Set all FMs except FM-G1 range 1–2–3 Machine model input — out No Default to machine model 2, of range sets FMs for FWA 1–2–4 System status lamp failure — Yes FM-G1 short to power 1–2–5 System status lamp failure — No FM-G1 short to ground 1–3–1 CAN Bus failure Yes FM-T1, FM-T2, Assume engine running at low idle 2–1–1 Park brake release failure — No FM-M1 short to power 2–1–2 Park brake release failure — No FM-M1 short to ground or open 2–1–3 Park brake set lamp failure — Yes FM-M2 short to power 2–1–4 Park brake set lamp failure — No FM-M2 short to ground 2–1–5 Motor shift output failure — No FM-M3 short to power 2–2–1 Motor shift output failure — No FM-M3 short to ground 2–2–2 Planetary shift high output No FM-M4 failure — short to power 2–2–3 Planetary shift high output No FM-M4 failure — short to ground 2–2–4 Planetary shift low output No FM-M5 failure — short to power 2–2–5 Planetary shift low output No FM-M5 failure — short to ground 3–1–1 LH Lever stop switch failed or No FM-P1, FM-P2, FM-P3, FM-P4 shorted to power 3–1–2 LH Lever stop switch open or No FM-P1, FM-P2, FM-P3, FM-P4 shorted to ground 3–1–3 LH Lever position voltage too No FM-P1, FM-P2, FM-P3, FM-P4 high 3–1–4 LH Lever position voltage too No FM-P1, FM-P2, FM-P3, FM-P4 low 3–1–5 RH Lever stop switch failed No FM-P1, FM-P2, FM-P3, FM-P4 closed or shorted to power 3–2–1 RH Lever stop switch failed No FM-P1, FM-P2, FM-P3, FM-P4 open or shorted to ground 3–2–2 RH Lever position voltage too high 3–2–3 RH FSR Position voltage too No FM-P1, FM-P2, FM-P3, FM-P4 low 3–2–4 LH Ground speed present with No FM-M1 no propulsion command 3–2–5 LH Propulsion command with Yes FM-P5 no LH speed detected 3–3–1 RH Ground speed present No FM-M1 with no propulsion command 3–3–2 RH Propulsion command with Yes FM-P6 no RH speed detected 3–3–3 Marker code 3–3–4 Machine movement detected No Information only during park brake test 3–3–5 LH Propel forward failure — No FM-P1, FM-P3 short to power 3–4–1 LH Propel forward failure — No FM-P1, FM-P3 short to ground or open 3–4–2 LH Propel reverse failure — No FM-P2, FM-P4 short to power 3–4–3 LH Propel reverse failure — No FM-P2, FM-P$ short to ground or open 3–4–4 RH Propel forward failure — No FM-P1, FM-P3 short to power 3–4–5 RH Propel forward failure — No FM-P1, FM-P3 short to ground or open 3–5–1 RH Propel reverse failure — No FM-P2, FM-P4 short to power 3–5–2 RH propel reverse failure — No FM-P2, FM-P4 short to ground or open 3–5–3 LH Propulsion calibration No Default calibration values used. failed Information only 3–5–4 RH Propulsion calibration No Default calibration values used. failed Information only 4–1–1 Machine in motion output No FM-P7 failure — short to power 4–1–2 Machine in motion output No FM-P7 failure — short to ground 4–1–3 Backup alarm output failure — No FM-P8 short to power 4–1–4 Backup alarm output failure — No FM-P8 short to ground 5–1–1 Hopper weight voltage too No FM-F3 high 5–1–2 Hopper weight voltage too No FM-F3 low 5–1–3 FWA Command failure — No FM-F1 (FWA tractor only) short to power 5–1–4 FWA Command failure — No FM-F1 (FWA tractor only) short to ground or open 5–1–5 FWA On output failure — No FM-F2 (FWA tractor only) short to power 5–2–1 FWA On output failure — No FM-F2 (FWA tractor only) short to ground 5–2–2 FWA Armed lamp output No FM-F4 (FWA tractor only) failure — short to power 5–2–3 FWA Armed lamp output No FM-F4 (FWA tractor only) failure — short to ground 6–1–1 Positrac front wheel output No FM-D1 (FWA tractor only) failure — short to power 6–1–2 Positrac front wheels output No FM-D1 (FWA tractor only) failure — short to ground 6–1–3 Positrac rear forward output No FM-D2, FM-D3 (Wheel tractor failure — short to power only) 6–1–4 Positrac rear forward output No FM-D2, FM-D3 (Wheel tractor failure — short to ground only) 6–1–5 Positrac rear reverse output No FM-D2, FM-D3 (Wheel tractor failure — short to power only) 6–2–1 Positrac rear reverse output No FM-D2, FM-D3 (Wheel tractor failure — short to ground only) 7–1–1 Tamper speed single output No FM-T1 failure — short to power 7–1–2 Tamper speed single output No FM-T1 failure — short to ground or open 7–1–3 Tamper speed dual output No FM-T2 failure — short to power 7–1–4 Tamper speed dual output No FM-T2 failure — short to ground or open
Fault code list, feeder controller
Fault code Description Recoverable Associated FM and remarks 1–1–1 System voltage — low Yes None stored, just displayed 1–1–2 System voltage — high Yes 1–1–3 Sensor voltage 1 — low No Set all FMs except FM-G1 1–1–4 Sensor voltage 1 — high No Set all FMs except FM-G1 1–1–5 Sensor voltage 2 — low No Information only 1–2–1 Sensor voltage 2 — high No Information only 1–2–2 Machine type input — out of No Set all FMs except FM-G1 range 1–2–4 System status output failure Yes FM-G1 — short to power 1–2–5 System status output failure No FM-G1 — short to ground 3–1–2 LH Conveyor HoM sensor — No FM-AC9 signal missing 3–1–4 RH Conveyor HoM sensor — No FM-AC10 signal missing 3–2–1 LH Auger HoM sensor — No FM-AC9 signal missing 3–2–3 RH Auger HoM sensor — No FM-AC10 signal missing 3–2–4 LH Conveyor speed output — No FM-AC1 short to power 3–2–5 LH Conveyor speed output — No FM-AC1 short to ground or open 3–3–1 LH Conveyor reverse output Yes FM-AC2 failure — short to power 3–3–2 LH Conveyor reverse output No FM-AC2 failure — short to ground 3–3–3 Marker code 3–3–4 RH Conveyor speed output — No FM-AC3 short to ground or open 3–3–5 RH Conveyor reverse output Yes FM-AC4 failure — short to power 3–4–1 RH Conveyor reverse output No FM-AC4 failure — short to ground 3–4–2 LH Auger speed output — No FM-AC5 short to power 3–4–3 LH Auger speed output — No FM-AC5 short to ground or open 3–4–4 LH Auger reverse output Yes FM-AC6 failure — short to power 3–4–5 LH Auger reverse output No FM-AC6 failure — short to ground 3–5–1 RH Auger speed output — Yes FM-AC7 short to power 3–5–2 RH Auger speed output — No FM-AC7 short to ground or open 3–5–3 RH Auger reverse output Yes FM-AC8 failure — short to power 3–5–4 RH Auger reverse output No FM-AC8 failure — short to ground 3–5–5 Auger/conveyor auto lamp Yes FM-AC11 failure — short to power 4–1–1 Auger/Conveyor auto lamp No FM-AC11 failure — short to ground 4–1–2 LH Auger override speed Yes LH Manual auger speed input voltage — too low command 100% 4–1–3 RH Auger override speed Yes RH Manual auger speed input voltage — too low command 100% 4–1–4 RH Conveyor speed output — No FM-AC3 short to power 5–1–1 Mixer auto lamp failure — No FM-M1 short to power 5–1–2 Mixer auto lamp failure — No FM-M1 short to ground 5–1–3 Mixer speed output failure — No FM-M2 short to power 5–1–4 Mixer speed output failure — No FM-M2 short to ground or open
Fault codes, general purpose systems controller
Fault code Description Recoverable Associated FM and remarks
1–1–1 System voltage — low Yes None stored, just displayed 1–1–2 System voltage — high Yes 1–1–3 Sensor voltage 1 — low No Set all FMs except FM-G1 1–1–4 Sensor voltage 1 — high No Set all FMs except FM-G1 1–1–5 Sensor voltage 2 — low No Information only 1–2–1 Sensor voltage 2 — high No Information only 1–2–2 Machine type input — out of No Set all FMs except FM-G1 range 1–2–3 Machine model input — out No Default to machine model 2, of range sets FMs for FWA 1–2–4 System status lamp failure — Yes FM-G1 short to power 1–2–5 System status lamp failure — No FM-G1 short to ground 1–3–1 CAN Bus failure No FM-C1, Default to engine running state for alarm system 2–1–1 Engine coolant temp sensor No FM-C1 failure 2–1–2 Intake manifold temp sensor No FM-C1 failure 2–1–3 Hydraulic oil temp sensor No FM-C1, FM-A2, Error condition failure (0xFE) transmitted on CAN bus 2–1–4 Cooling fan output failure — No FM-C1 short to power 2–1–5 Cooling fan output — short to No FM-C1 ground or open 2–2–1 High throttle short high Yes 2–2–2 High throttle short low Yes 3–1–1 Fuel level sensor out of range Yes Error condition (0xFE) transmitted on CAN bus 3–1–2 General purpose unload short high 3–1–3 General purpose unload short low 3–1–4 Washdown motor short high 3–1–5 Washdown motor short low 3–2–1 Washdown track short high 3–2–2 Washdown track short low 3–3–3 Marker code 4–1–1 Alarm output failure — short No FM-A1 to power 4–1–2 Alarm output failure — short No FM-A1 to ground 4–1–3 High hydraulic oil temp No FM-A2 output failure — short to power 4–1–4 High hydraulic oil temp No FM-A1 output failure — short to ground 5–1–1 Material alarm short high 5–1–2 Material alarm short high 6–1–1 Generator command without speed 6–1–2 Generator speed without command 6–1–3 Generator EDC short high 6–1–4 Generator EDC short low 6–1–5 Generator lamp short high 6–2–1 Generator lamp short low