You are on page 1of 3

ASCE 7-10

LOAD COMBINATION:

2.3.2 Ultimate Stress

U100 1.4D
U101 1.2D + 1.6L + 0.5Lr
U102 1.2D + 1.6Lr + L
U200 1.2D + 1.6Lr ± 0.5WLx
U201 1.2D + 1.6Lr ± 0.5WLy
U202 1.2D ± 1.0WLx + L + 0.5Lr
U203 1.2D ± 1.0WLy + L + 0.5Lr
U204 0.9D ± 1.0WLx
U205 0.9D ± 1.0WLy
U300 (1.2 + 0.2SDs)D ± ρE + L
U301 (0.9 - 0.2SDs)D ± ρE

E shall be:

E = SRSS or 100%Ex ± 30%Ey and 100%Ey ± 30%Ex

Refer to ASCE 7 for notes

2.4.1 Allowable Stress

A100 D
A101 D + L
A102 D + Lr
A103 D + 0.75L + 0.75Lr
A200 D ± 0.6WLx
A201 D ± 0.6WLy
A202 D + 0.75L ± 0.75(06WLx) + 0.75Lr
A203 D + 0.75L ± 0.75(0.6WLy) + 0.75Lr
A300 D ± 0.7Ex
A301 D ± 0.7Ey
A302 0.6D ± 0.7Ex
A303 0.6D ± 0.7Ey
Load Cases
AS1170
G - Dead Load/SDL
LOAD COMBINATION: Q - Live Load
WLx/y - Wind load on walls
4.2.2 Strength Wu/d - Wind lod on roof (Up/Down)
Eq - Seismic
U100 1.35G
U101 1.2G + 1.5Q
U102 1.2G + 1.5 Q
U200 1.2G + WLx + Wu + Q
U201 1.2G + WLy + Wu + Q
U202 0.9G - WLx - Wd
U203 0.9G - WLy - Wd
U300 1.0G + Eqx + Q
U301 1.0G + Eqy + Q

4.3 Serviceability

Combination of actions for the serviceability limit states shall be


appropriate for the serviceability condition being considered.
Appropriate combinations may include one or a number of the following
using the short-term and long-term values given in Table 4.1:

(a) G
(b)
(c)
(d) Ws
(e) Es
(f) Serviceability values of other actions, as appropriate.