Vulcan Burner/Incinerator

Comparison Chart & Specifications


Little Vulcan Vulcan 0.3* Vulcan 0.5* Vulcan 1.0* Vulcan 1.5*
1.0 MMBtu/hr
System Capacity 0.3 MMBtu/hr 0.5 MMBtu/hr 1.5 MMBtu/hr
waste combus-
*Waste streams with and waste combus- waste combustion. waste combustion.
Up to 30 pounds tion. 140-200 lbs/
average gross HHV range tion. 30-50 lbs/hr 55-85 lbs/hr pro- 175-250 lbs/hr
of 5500-8500 Btu/lb. hr processing
processing capacity. cessing capacity. processing capacity.
capacity.
55 Gallon Stain- Dual Chamber Dual Chamber Dual Chamber Dual Chamber
Design
less Steel Drum with Exhaust Stack with Exhaust Stack with Exhaust Stack with Exhaust Stack
Manually
Self Regulated via Self Regulated via Self Regulated via Self Regulated via
Air Supply Regulated via
System Controls System Controls System Controls System Controls
Back Blower
Loading Easy Load Hopper Primary Chamber Primary Chamber Primary Chamber Primary Chamber
Single point - 230V,
Single point - Single point -
Electrical 3 dial, 60 Hz, 50
Standard 110 V 120 VAC, 25AMP 230/460V, 3 dia., 230/460V, 3ø, 60
Requirements amp w/optional
60 Hz/25/15 amp Hz, 25/15 amp
loader
Wood or Diesel or #2 Fuel Diesel or #2 Fuel Diesel or #2 Fuel Diesel or #2 Fuel
Fuel Requirements
Charcoal Oil Oil Oil Oil
Primary Chamber / Fixed Hearth
Chamber Volume 13.5 cubic ft. 25.2 cubic ft. 66.8 cubic ft. 86 cubic ft.
Hearth Area 5 square ft. 8 square ft. 10 square ft. 14 square ft.
0.4 MMBtu/hr. 0.278-0.45 MMB- 0.28-0.45 MMBtu/
0.25 MMBtu/hr
Burner Capacity nom (Hi-Lo-Off tu/hr. (Hi-Lo-Off hr. (Hi-Lo-Off
nom
Control) Control) Control)
Secondary Chamber
Cyclonic Thermal Cyclonic Thermal
Cyclonic Thermal Cyclonic Thermal
Oxidizer with 1+ Oxidizer with 1+
Type Oxidizer with 1+ Oxidizer with 1+
sec. r/t @ 1600oF sec. r/t @ 1600oF
sec. r/t sec. r/t
(850oC) (850oC)
Chamber Volume 13.5 cubic ft. 17.1 cubic ft. 39.15 cubic ft. 51 cubic ft.
1 MMBtu/hr 0.35-1.12 MMBty/
0.25 MMBtu/hr.
Burner Capacity 0.5 MMBtu/hr (modulating, ex- hr. (modulating,
nom
cess air control) excess air control)
Required
Commissioning of No No Yes Yes Yes
Certified Technician

For more complete information on GEI Works products and solutions, visit us on the Web at
www.geiworks.com.

Toll Free: 1-888-703-9889 | Phone: (1+) 772-646-0597 | info@geiworks.com

© 2015 GEI Works


All rights reserved
GEI Works terms and conditions apply.

All photos are representative only. Actual Product may differ than featured.

GEI Works, Mars,Taurus, Triton, Kraken, Orion,Vulcan and geiworks.com, their respective
logos, product identity used herein, are trademarks of GEI Works and may not be used
without permission.

You might also like