You are on page 1of 2

Architecture, Engineering and Construction

Example markups include Inking,


Length Measure, Area Measure and
12.38sq in
8.71 cm

Project S-302
Drawboard Developments
Precast Stair Lift Core
2 Funge St, Melbourne
0.34in

0.42sq in
2.46in

drawboard.com | Project S-302 | 1


A0

STAIR AND LIFT CORE PANEL


LEGEND
C3.E1 C3.E1 C3.E1 C3.E1 C3.E1 C3.E1 C3.E1 C3.E1
P1 DENOTES PRECAST PANEL TYPE
N.F. DENOTES NEAR FACE

C3.E6

C3.E6

C3.E6

C3.E6

C3.E6

C3.E6

C3.E6

C3.E6
F.F. DENOTES FAR FACE

C3.E4

C3.E4

C3.E4

C3.E4

C3.E4

C3.E4

C3.E4

C3.E4
E.F. DENOTES EACH FACE
C3.E2

C3.E2

C3.E2

C3.E2

C3.E2

C3.E2

C3.E2

C3.E2
DENOTES PRECAST PANEL CONNECTION
TYPE (F.F.)
DENOTES PRECAST PANEL CONNECTION
TYPE (N.F.)
C3.E5 C3.E5 C3.E5 C3.E5 C3.E5 C3.E5 C3.E5 C3.E5
REFER S.306
DENOTES REBATED CONNECTION (N.F.) FOR DETAILS

DENOTES REBATED CONNECTION (F.F.)


C3.E3 C3.E3 C3.E3 C3.E3 C3.E3 C3.E3 C3.E3 C3.E3
DENOTES REBATED CONNECTION (E.F.)

BASEMENT 2 - CORE KEY PLAN BASEMENT 1 - CORE KEY PLAN GROUND FLOOR - CORE KEY PLAN LEVEL 1 - CORE KEY PLAN LEVEL 2 - CORE KEY PLAN LEVEL 3 - CORE KEY PLAN LEVEL 4 - CORE KEY PLAN LEVEL 5 - CORE KEY PLAN NOTES:

PART PLAN - C3.B2 PART PLAN - C3.B1 PART PLAN - C3.G PART PLAN - C3.01 PART PLAN - C3.02 PART PLAN - C3.03 PART PLAN - C3.04 PART PLAN - C3.05 1. REFER TO ARCHITECTS AND SERVICES DRAWINGS FOR
SIZE AND LOCATIONS OF ALL PENETRATIONS.
SCALE: 1 : 100 SCALE: 1 : 100 SCALE: 1 : 100 SCALE: 1 : 100 SCALE: 1 : 100 SCALE: 1 : 100 SCALE: 1 : 100 SCALE: 1 : 100

6 5 E 5 6 E 6 E
250 THICK PRECAST LID.
250 THICK PRECAST LID.
250 THICK PRECAST LID.

4 4 4 4
Level 5 Level 5
4 4 4 4
CP1 CP1 CP1 CP1 CP1
250 THICK PRECAST LID. CP1

Level 4 Level 4

CP1
CP1 CP1 CP1
CP1
CP1

Level 3 Level 3

CP1 CP1 CP1 CP1 CP1


CP1

Level 2 Level 2

CP1 CP1 CP1 CP1


CP1 CP1

Level 1 Level 1

CP1
CP1 CP1 CP1
CP1
CP1

GROUND FLOOR GROUND FLOOR

CP1 CP1
CP1 CP1 CP1
CP1

BASEMENT 1 BASEMENT 1

CP1 CP1 CP1 CP1 CP1


CP1

BASEMENT 2 BASEMENT 2

INSITU OVERRUN.
MIN 230mm THICK. INSITU OVERRUN. INSITU OVERRUN.
REINFORCEMENT
TO MATCH CORE.

ELEVATION C3.E1 ELEVATION C3.E2 ELEVATION C3.E3 ELEVATION C3.E4 ELEVATION C3.E5 ELEVATION C3.E6 STAIR/ LIFT CORE ISOMETRIC
SCALE: 1 : 100 SCALE: 1 : 100 SCALE: 1 : 100 SCALE: 1 : 100 SCALE: 1 : 100 SCALE: 1 : 100 SCALE:

PRECAST COREWALL SCHEDULE


REINFORCEMENT
MARK THICKNESS F'c VERTICAL HORIZONTAL REMARKS
CP1 230 - - -
CP2 280 - - -

WORK IN PROGRESS
REVISION PROJECT NORTH CLIENT ARCHITECT PRECAST STAIR/ LIFT CORE - KEY PLANS AND
ISSUE DATE DRAWBOARD DEVELOPMENTS ELEVATIONS
2 FUNGE ST
DATE: JULY 2016 DESIGNED: BB
MELBOURNE
DRAWN: CC CHECKED: AA
brogue.com.au
(03) 9416 2092

SCALE: 1 : 100 SIZE: A0

PRELIMINARY Job No. Drawing No. Rev.

NOT FOR CONSTRUCTION ----- S.302


© BROGUE

You might also like