Professional Documents
Culture Documents
RFG 069723
RFG 069723
GENERAL:
The following is important information about on the optional Anti-Condensation Heaters. There are 4 types of
Anti-Condensation Heaters that are available as service parts for the following components:
Mainframe Tray
Optional Tray (PB3150, PB3220/PB3210, PB3230, PB3170)
PCU
Scanner
See the table below for the parts required when installing the Anti-Condensation Heaters.
Scanner Heater
+ PCU Heater
+ PCU Heater
PCU Heater
continued…
PART INFORMATION:
Assembly-1:
Heater PCB is composed of the following parts.
Part Number Description Q’ty
D2025185 PCB: DHB 1
D2025396 Harness: BCU: Dehumidifier: DC 1
D2025397 Harness: Power Supply Unit: Dehumidifier: AC 1
D2025398 Harness: Dehumidifier: Paper Feed: Bank 1
04543006Q Tapping Screw - M3X6 3
11050758 Clamp: LWSM-0306A 7
11050763 Clamp: LWS-1211A 1
Assembly-2:
Scanner Heater is composed of the following parts.
Part number Description Q’ty
D2021836 Cover: Heater: Scanner 1
D1491835 Bracket: Dehumidifier: Heater 1
B2291688 (EU) Heater: Option: 230V: 9W 1
B2291687 (NA) Heater: 120V:9W 1
03530050N Screw: M3X5 1
03530030N Screw: M3X3 2
IMPORTANT:
Make sure to install the tray heater with the rated voltage that matches your country/region.
If you do not, the heater will overheat and damage the tray and/or cause carbonization (Ex., If a
100V heater is installed on a 200V rated machine), or the heater will not be able to reduce enough
moisture (Ex., If a 200V heater is installed on a 100V rated machine).
Page 2 of 2