Volume of water consumed = 100 x 100 = 10000 litres / day or 10cum/ day
Hence average volume of wastewater generated = 10000 x 0.8 = 8000 litres / day or approx 8 cum/ day.
For Settler
Daily WasteWater flow = 8 m3/day
Peak Hours = 8 hrs.
BODin = 250 mg/L
CODin = 450 mg/L
SS/COD Ratio = 0.42
HRT = 1.5 hrs.
Surface load = 0.6
SRT = 12 months
Sludge Volume = 0.005 m3
Water depth at outlet = 2.00 m
Height of Scum layer = 0.20 m
Proposed inner width = 1.00 m
1)Design of Settler
Removal of Organic Pollutants (BOD & COD removal)
For HPGF
Expected BODout = 10 mg/L
Depth = 0.60 m
Roundup width from calculated one = 2.60 m
Roundup length from calculated one = 4.50 m
4)Design of Horizontal Planted Gravel Filter (HPGF)
Removal of Organic Pollutants (BOD & COD removal)
BODin = 9 mg/L
CODin = 31 mg/L
Expected BODout = 10 mg/L
COD/BOD ratio = 3.44
BOD removal rate = -0.11
Factor efficiency ratio of BOD removal to COD
removal = 1.06
COD removal rate = -0.1
CODout = 34 mg/L
Hydraulic design requirements
Hydraulic conductivity = 372 m/day
Factor HRT to BOD removal = -0.06
Factor HRT to temperature = 9.4
HRT = -0.56
HRT in 35% pore space = -0.2
Determination of Chamber size
Cross section area = 2.15
Required width of filter basin = 3.58 m
Chosen width of filter basin = 2.6
Required surface area = -8 m2
Required length of filter basin = -3.08 m
Chosen length of filter basin = 4.5 m
Actual Surface Area = 11.7
Hydraulic Load on chosen surface = 0.68
Design
Organic load on chosen surface (BODout) = 6.12 mg/l Remark OK!!!
5)Polishing Ponds
8 cum of wastewater is generated per day then the size of the planted filter will be about 9.6 sq m