HITACHI

Quick Team Call center

ELEVATOR & ESCALATOR

HITACHI ELEVATOR (CAMBODIA)CO.,LTD.


Compositio
n
of Elevator
Machine Room
Control Panel
Machine Room
Magnetic Brake
Machine Room
Machine Room
Safety Catch
Counter Weight
Car Cage
Door
Car Cage
Door Lock Switch
HATCH DOOR

HEADER DOOR CLOSE

LANDING DEVICE

POSITION DETECTOR
SHEILDING PLATE
Hall
Hall Lantern

Hall Indicator

Hall Button
Car Cage

CPI
Car Position Indicator

OPB
Operation Panel Board
OPB & Switch Box

Interphone
Emergency Call Button
Interphone & Emergency Call Button
โทรศัพท์ติดต่อฉุกเฉิน
OPB & Switch Box
แผงปุ่มกด และแผงสวิตช์ควบคุม
Interphone
Emergency Call Button
Door Open/Close Button
Floor Buttons

Extend Open

Switch box
Safety Devices
1 7
1. Safety Drive System
13 9
2. Safety Return System
6 8
12 3. Door Safety Shoe
5 4. Door Inter Lock
2 5. Over Load Alarm
3 6. Interphone and Emergency Call Button
10
7. Electro Magnetic Brake
8. Terminal and Final Landing
4
9-10 Governor and Safety Catch
11. Terminal Buffer
8
6 12. Emergency Lighting
11 13. Electric Control System
Function
7. Fire Emergency Operation (Option)
8. Fire Service Operation (Option)
Function
11. Attendant Operation (Option)
12. Independent Operation (Option)

Independent Operation

Attendant Operation
Regulation
( for Building officials )
Regulation for building officials
1. Evening.....After use elevator

•Park in the designated elevator


Turn off the switch in the OPB switch box
Lock the lid OPB switch Box
Regulation for building officials
2. Morning.....Activate the elevator

•Detect the position of the van parked at the elevator


which floor.
•That the elevator door open landings exist.
•Check the operation of the elevator.
Regulation for building officials
3. Working hours..... As used the elevator.

•Walks to the elevator that


there's anything wrong or not.
•The emergency call. Officers should
be stationed.
Examination
Examination General condition before use.
3. Push button is working correctly.

4. Check the sill


Examination General condition before use.
5. Check the operation of the phone.
INTERPHONE SYSTEM Communication system is the only device that is
used to communicate between the passengers trapped in the cage.
เจ้ าหน้ าที่ของอาคาร

1) EMERGENCY CALL button on the


control panel (OPB), the buzzer will
be on the phone 1 fl. and machine
room simultaneously.
Examination General condition before use.
From the outside to the phone of
elevator. just picking up the phone
to speak with someone in a lift at all.
If the event is more than one
elevator to press the number of the
elevator before you communicate.

Maintenance telephone.
After hanging up the phone, then you need to close all .The BATTERY CHARGE
to use the time to prepare.
BATTERY should change when the set time period.
Examination General condition before use.
6. Try to up - down and
listen to voice disorders.

7. Check out a set of keys


OK

to open elevator doors


or not.
Examination General condition before use.
8. The point where the water comes
into the elevator or not.
Attendance
Cleaning.
Caution
Caution
1. Do not allow children
to play near the
elevator.

2. Do not allow children to use the


elevator alone.
Caution
3. No smoking in the elevator.

4. Do not elevator the damaged intentionally


Caution
5. Beware of the excess weight.
6. Be careful not to have any.
Knocked on the door .

7. Do not use hard materials, press, push


elevator buttons.
8. Do not use elevators. Removal of
heavy too

9. When the elevator door opened for wool


or should use the Attendance or
Independent.
10.Prohibit unauthorized
personnel. The elevator
machine room.

11.Do not let the temperature in


the machine room
overheating.
Escalator
Composition
Top

Middle

Bottom
Composition
Top Landing Control Panel
Operation Board
Comb
Handrail Drive Unit
Traction machine Handrail
Demarcation
Terminal Gear Skirt Guard
Step Chain
Inner Deck
Front Roller
Glass
Frame
Comb
Operation Board
Step
Step cleat riser
Outer Deck Bottom Landing
Machine Room
Traction machine Control Panel
Ste
p
Cleat Step

Cleat riser
Step
Demarcation
Comb
Handrail
Handrail Drive Unit
Operating
Board LIGHT
OFF ON
Auto Start
Protective
Devices
Protective Devices
อุปกรณ์ป้องกัน
Protective Devices
Initials Full name
T.I.S. Handrail Inlet Safety Device สวิตช์ ป้องกันวัสดุเข้ าไปติดทางเข้ าราวมือ
S.G.S. Skirt Guard Safety Device สวิตช์ ป้องกันวัสดุเข้ าไปติดแผ่ นปิ ดด้ านข้ าง
S.T.S. Step Travel Safety Device สวิตช์ ป้องกันล้ อลูกขั้นกระโดด
D.C.S. Drive Chain Safety Device สวิตช์ ป้องกันโซ่ ขบั เคลื่อนขาด
T.C.S. Step Chain Safety Device สวิตช์ ป้องกันโซ่ ลูกขั้นขาด
- Emergency Stop Button สวิตช์ หยุดฉุกเฉิน
- Overload Protective Device ชุ ดป้ องกันกระแสไฟฟ้ าเกิน
- Governor อุปกรณ์ ตรวจจับความเร็ว
Handrail Inlet Safety
Device (TIS)
Handrail Inlet Safety Device (TIS)
Skirt Guard Safety Device
(SGS)
Skirt Guard Safety Device (SGS)
Step Travel Safety
Device (STS)
Step Travel Safety Device (STS)
Step Running Safety Device
(SRS)
Step Running Safety Device (SRS)
Drive Chain Safety
Device (DCS)
Drive Chain Safety Device (DCS)
Step Chain Safety
Device (TCS)
Step Chain Safety Device (TCS)
Emergency Stop
Button (E-stop)
Emergency Stop Button (E-stop)

Emergency
Stop
Regulatio
n ( for
Building officials )
Regulation for building officials
1. Morning.....Activate the escalator
•Check the general condition of the
escalator.
Regulation for building officials
1. Morning.....Activate the escalator
•Cleaning escalators.
Regulation for building officials
1. Morning.....Activate the escalator
•Activate the correct instructions.
Regulation for building officials
1. Morning.....Activate the escalator
•ตรวจเช็คการทางานของบันไดเลื่อน
Regulation for building officials
2. At work ..... while using escalators.
•Inspected the escalator that there's anything
wrong or not.

?
Examination
1. Safety equipment. Labels
and instructions must be in
normal condition.

2. Do not place any obstacle


with the escalator.
3. Beware of the material to the
tooth.

4. Beware of water to clean.


การตรวจสอบและการดูแลรักษาบันไดเลื่อน
5. Beware of water from
outside.

6. Oversee the use of


the escalator.
Caution
Caution
1. Children and the
elderly should be care.

2. Beware head out of the


escalator.
Caution
3. Do not use a cart on the
escalator.

4. Do not run on the escalator.


Caution
5. Do not use sharp jabs at the
step escalators.

6. No smoking
Caution
7. Do not stand on the step
more than 2 person.

8. Beware any impact glass.


Caution

9. Beware of the burden too.

10.Do not place objects on the


hand rail.
Caution

11.Do not lean against the


side.

12.Step on to the
pavement.
Caution
13. Do not stand on the side
cover. Or climb the
handrail.

14.Do not play around the pond


escalator.
Caution

15.Beware of falling objects


on the escalator.

16.Do not sit on the


step escalators.
How to use the escalator.
Emergency
Emergency
I. Event of a power outage.
- The building has a power
reserve. (Generator)
Emergency
I. Event of a power outage.
- No electricity building
back up (Generator),
but with rescue
equipment automation.
(ALP)
Emergency
I. Event of a power outage.

-Building No Generator & ALP


Emergency
II. Fire building.

* Do not use elevators, fire escapes, is strictly prohibited.*


Emergency
III.Case of flooding.

- Moving the elevator up to the water


park. And it off.
Emergency
IV.An earthquake.

* Do not use the elevator and quickly evacuate the building *.


Rescue
passengers.
Causes the elevator down.
To be reasonably confident about Hitachi elevators controlled by micro
R computer Opportunity to lift the freeze as a passenger in the elevator is still there.
However, the backlog of elevator can be obtained from the following cases.
e
s 1. In the event of a power failure or power outage.

c 2. When the device security functionality.


u 3. To interfere with the switch in the panel by OPB users
without their knowledge.
e
Process of assisting the passengers.
1. Hold that position. Confirm the elevator down to
R confirm the position and cover OPB Position Switch power supply
that is unusual or off.
e
2. Arrangements for rescue . Let passengers know where to
s start to help to prevent the elevator suddenly moves to the floor to help the
passengers out.
c
u
e
Equipment should be provided
for all buildings.
1. Key of machine room
2. Hatch door
3. Flashlight
4. Chair or ladder
5. Administered first aid.
6. Warning open circuit.
Elements for all passengers.
1. Quickness
2. Accuracy
3. Safety
Process of rescue the passengers.
R 1. Hold that position. Confirm the elevator down to confirm the
position and cover OPB Position Switch power supply that is unusual or off.

e
2. Arrangements for rescue. passengers know where to start to help to
s prevent the elevator suddenly moves to the floor to help the passengers out.

c 3. Rescue
u 1.Rescue elevator where the elevator is stuck without a move.
2.Removed by mechanical brakes.

e Only person who has been tasked with building


maintenance only. And reviewed constantly.
Rescue passengers.
When the elevator outages. Passengers then
press emergency Call To get help.
1. Trying to contact passengers stuck in
the elevator. Using the emergency
phone. For further information.

2. Arrangements for rescue.


3. Cut the electricity supply to the lift
system. Whether any case. Before
the rescue.
Rescue passengers.
4. The key to unlock the door landings. Check that the
parking elevator to hold or not.
Rescue passengers.
5. When the elevator doors open and then find
parking pending. Are found parked pending 3
elevators look like. Outstanding Elevator parking above or below the
Outstanding Elevator parking above average.
or below the class average.
Always hold the elevator landing.
Rescue passengers.
Always hold the elevator landing.
Rescue passengers.
Outstanding Elevator parking above or below the class
average.
Rescue passengers.
Outstanding Elevator parking above or below the average.
Rescue passengers.
If you can’t help with that. Or not sure.
The wait staff. Savvy than a help.
Thank you